Plan Review Details - Permit 15110978
Plan Review Stops For Permit 15110978
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2015-12-16 Cont ID  
Sent By jwitmer Date 2015-12-16 Time 07:00 Rev Time 0.00
Received By jwitmer Date 2015-12-16 Time 06:27 Sent To E
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-01-11 Cont ID  
Sent By mvaldes Date 2016-01-11 Time 10:10 Rev Time 0.00
Received By mvaldes Date 2016-01-11 Time 10:10 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-01-04 Cont ID  
Sent By mvaldes Date 2016-01-04 Time 13:43 Rev Time 0.00
Received By mvaldes Date 2016-01-04 Time 13:43 Sent To  
Notes
2016-01-04 14:07:231ST REVIEW: FBC 2014 5TH ED. NEC 2011
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 516-805-6700
 [email protected]
 ALTERNATE CONTACT
 MIKE ALBARRAN
 561-805-6746
 [email protected]
  
 PLEASE SHOW MANUFACTURE SPECS ON UNDERGROUND SERVICE
 MODULES ?
 PROVIDE NOTES TO COMPLY WITH FBC E SECTION C405
 ELECTRICAL POWER AND LIGHTING SYSTEMS (MANDATORY)
 IN INDOOR LOCATIONS OTHER THAN DWELLINGS AND
 ASSOCIATED ACCESSORY STRUCTURES, FLUORESCENT LUMINAIRES
 THAT UTILIZE
 DOUBLE-ENDED LAMPS AND CONTAIN BALLAST(S) THAT CAN BE
 SERVICED IN PLACE SHALL HAVE A DISCONNECTING MEANS
 EITHER INTERNAL
 OR EXTERNAL TO EACH LUMINAIRE. FOR EXISTING INSTALLED
 LUMINAIRES
 WITHOUT DISCONNECTING MEANS, AT THE TIME A BALLAST IS
 REPLACED, A DISCONNECTING MEANS SHALL BE INSTALLED. THE
 LINE
 SIDE TERMINALS OF THE DISCONNECTING MEANS SHALL BE
 GUARDED. NEC 410.130 G
 FBC 1006.1 MEANS OF EGRESS ILLUMINATION.
 NEC 700.12 (F) (4)- EMERGENCY LIGHTING SHALL BE FED BY
 LIGHTING CIRCUIT OF SAME LOCAL AREA. *IF 3 OR MORE
 LIGHTING CIRCUITS SUPPLY THE AREA, EM LIGHTS MAY BE ON
 OWN CIRCUIT.
 FBC- 107.3.5.3 ? ELECTRIC SERVICE RISER WITH WIRE
 SIZES, CONDUIT DETAIL AND GROUNDING DETAIL. COMPLETE
 LOAD CALCULATIONS, PANEL SCHEDULES AND SHOW CIRCUITS ON
 FLOOR PLAN.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2015-12-09 Cont ID  
Sent By pleduc Date 2015-12-09 Time   Rev Time 0.00
Received By pleduc Date 2015-12-09 Time 12:27 Sent To  
Notes
2015-12-09 12:40:51THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
 1. SHEET E 2.1 - TWO ADDITIONAL EXIT SIGNS ARE REQUIRED
 TO IDENTIFY THE REQUIRED PATH OF TRAVEL FOR EACH SIDE
 OF THE OFFICE SPACE.
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2015-11-30 Cont ID  
Sent By pleduc Date 2015-11-30 Time   Rev Time 0.00
Received By pleduc Date 2015-11-30 Time 11:10 Sent To  
Notes
2015-11-30 11:12:54THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 1. THE SUBMITTED PLANS ARE TOO SMALL AND UNREADABLE.
 PLEASE ENLARGE AND RE-SUBMIT.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2016-01-11 Cont ID  
Sent By lmarchan Date 2016-01-11 Time 10:21 Rev Time 0.00
Received By lmarchan Date 2016-01-08 Time 12:44 Sent To  
Notes
2016-01-08 12:44:38RESUB ROUTED TO MVALDES

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-01-04 Cont ID  
Sent By cpuell Date 2016-01-04 Time 14:24 Rev Time 0.00
Received By cpuell Date 2015-12-04 Time 09:33 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-12-03 Cont ID  
Sent By skennedy Date 2015-12-03 Time 10:31 Rev Time 0.00
Received By skennedy Date 2015-11-24 Time 15:48 Sent To  
Notes
2015-12-03 10:34:39APPLICANT HAS SUBMITTED PHOTO COPIES OF THE DESIGN
 DOCUMENTS THAT DO NOT MEET THE REQUIREMENTS FOR DESIGN
 PROFESSIONAL SIGNATURE. SPOKE TO JOE GOMES OF GLIDDEN
 SPINA. HE WILL PROVIDE INFORMATION TO THE CONTRACTOR
 APPLICANT AS TO RE-SUBMITTING DIGITALLY, OR POSSIBLY
 PROVIDE RAISED SEALED PLANS.
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 (561) 805-6710
 [email protected]
  
2015-11-24 15:49:06B04

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2015-12-15 Cont ID  
Sent By ccole Date 2015-12-15 Time 08:23 Rev Time 0.00
Received By ccole Date 2015-12-15 Time 08:23 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2015-12-01 Cont ID  
Sent By ccole Date 2015-12-01 Time 09:36 Rev Time 0.00
Received By ccole Date 2015-12-01 Time 09:36 Sent To  
Notes
2015-12-01 09:50:331ST REVIEW 2014 MECHANICAL
 PERMIT #15110978
 12/1/15
  
 1) PROVIDE BUILDING PLANS THAT ARE LARGE ENOUGH TO READ
 AND REVIEW- THE PLAN SHEET SIZE MOST COMMONLY USED FOR
 THIS TYPE OF PROJECT IS TYPICALLY 24" X 36". BECAUSE OF
 THE REDUCED SIZE OF THESE PLANS THE PRINT AND DETAILS
 ON THEM ARE TO SMALL TO READ OR SCAN FOR PUBLIC RECORD
 RETENTION- SEE SECTION 107.2.1.4 WPB AMENDMENTS TO THE
 FBC-14 BUILDING CODE.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  
  

Review Stop Z ZONING
Rev No 1 Status P Date 2015-12-08 Cont ID  
Sent By sgraham Date 2015-12-08 Time 10:51 Rev Time 0.00
Received By sgraham Date 2015-12-08 Time 10:51 Sent To  
Notes
***NONE***