| Plan Review Stops For Permit 15110978 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2015-12-16 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-12-16 |
Time |
07:00 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-12-16 |
Time |
06:27 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2016-01-11 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-01-11 |
Time |
10:10 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-01-11 |
Time |
10:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2016-01-04 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-01-04 |
Time |
13:43 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-01-04 |
Time |
13:43 |
Sent To |
|
|
| Notes |
| 2016-01-04 14:07:23 | 1ST REVIEW: FBC 2014 5TH ED. NEC 2011 | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 516-805-6700 | | | [email protected] | | | ALTERNATE CONTACT | | | MIKE ALBARRAN | | | 561-805-6746 | | | [email protected] | | | | | | PLEASE SHOW MANUFACTURE SPECS ON UNDERGROUND SERVICE | | | MODULES ? | | | PROVIDE NOTES TO COMPLY WITH FBC E SECTION C405 | | | ELECTRICAL POWER AND LIGHTING SYSTEMS (MANDATORY) | | | IN INDOOR LOCATIONS OTHER THAN DWELLINGS AND | | | ASSOCIATED ACCESSORY STRUCTURES, FLUORESCENT LUMINAIRES | | | THAT UTILIZE | | | DOUBLE-ENDED LAMPS AND CONTAIN BALLAST(S) THAT CAN BE | | | SERVICED IN PLACE SHALL HAVE A DISCONNECTING MEANS | | | EITHER INTERNAL | | | OR EXTERNAL TO EACH LUMINAIRE. FOR EXISTING INSTALLED | | | LUMINAIRES | | | WITHOUT DISCONNECTING MEANS, AT THE TIME A BALLAST IS | | | REPLACED, A DISCONNECTING MEANS SHALL BE INSTALLED. THE | | | LINE | | | SIDE TERMINALS OF THE DISCONNECTING MEANS SHALL BE | | | GUARDED. NEC 410.130 G | | | FBC 1006.1 MEANS OF EGRESS ILLUMINATION. | | | NEC 700.12 (F) (4)- EMERGENCY LIGHTING SHALL BE FED BY | | | LIGHTING CIRCUIT OF SAME LOCAL AREA. *IF 3 OR MORE | | | LIGHTING CIRCUITS SUPPLY THE AREA, EM LIGHTS MAY BE ON | | | OWN CIRCUIT. | | | FBC- 107.3.5.3 ? ELECTRIC SERVICE RISER WITH WIRE | | | SIZES, CONDUIT DETAIL AND GROUNDING DETAIL. COMPLETE | | | LOAD CALCULATIONS, PANEL SCHEDULES AND SHOW CIRCUITS ON | | | FLOOR PLAN. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2015-12-09 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2015-12-09 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2015-12-09 |
Time |
12:27 |
Sent To |
|
|
| Notes |
| 2015-12-09 12:40:51 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | 1. SHEET E 2.1 - TWO ADDITIONAL EXIT SIGNS ARE REQUIRED | | | TO IDENTIFY THE REQUIRED PATH OF TRAVEL FOR EACH SIDE | | | OF THE OFFICE SPACE. | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2015-11-30 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2015-11-30 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2015-11-30 |
Time |
11:10 |
Sent To |
|
|
| Notes |
| 2015-11-30 11:12:54 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1. THE SUBMITTED PLANS ARE TOO SMALL AND UNREADABLE. | | | PLEASE ENLARGE AND RE-SUBMIT. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2016-01-11 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2016-01-11 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2016-01-08 |
Time |
12:44 |
Sent To |
|
|
| Notes |
| 2016-01-08 12:44:38 | RESUB ROUTED TO MVALDES |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-01-04 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2016-01-04 |
Time |
14:24 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2015-12-04 |
Time |
09:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-12-03 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-12-03 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-11-24 |
Time |
15:48 |
Sent To |
|
|
| Notes |
| 2015-12-03 10:34:39 | APPLICANT HAS SUBMITTED PHOTO COPIES OF THE DESIGN | | | DOCUMENTS THAT DO NOT MEET THE REQUIREMENTS FOR DESIGN | | | PROFESSIONAL SIGNATURE. SPOKE TO JOE GOMES OF GLIDDEN | | | SPINA. HE WILL PROVIDE INFORMATION TO THE CONTRACTOR | | | APPLICANT AS TO RE-SUBMITTING DIGITALLY, OR POSSIBLY | | | PROVIDE RAISED SEALED PLANS. | | | | | | STEVEN KENNEDY, CBO | | | CHIEF PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | (561) 805-6710 | | | [email protected] | | | | | 2015-11-24 15:49:06 | B04 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2015-12-15 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-12-15 |
Time |
08:23 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-12-15 |
Time |
08:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2015-12-01 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-12-01 |
Time |
09:36 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-12-01 |
Time |
09:36 |
Sent To |
|
|
| Notes |
| 2015-12-01 09:50:33 | 1ST REVIEW 2014 MECHANICAL | | | PERMIT #15110978 | | | 12/1/15 | | | | | | 1) PROVIDE BUILDING PLANS THAT ARE LARGE ENOUGH TO READ | | | AND REVIEW- THE PLAN SHEET SIZE MOST COMMONLY USED FOR | | | THIS TYPE OF PROJECT IS TYPICALLY 24" X 36". BECAUSE OF | | | THE REDUCED SIZE OF THESE PLANS THE PRINT AND DETAILS | | | ON THEM ARE TO SMALL TO READ OR SCAN FOR PUBLIC RECORD | | | RETENTION- SEE SECTION 107.2.1.4 WPB AMENDMENTS TO THE | | | FBC-14 BUILDING CODE. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2015-12-08 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2015-12-08 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
2015-12-08 |
Time |
10:51 |
Sent To |
|
|
| Notes |
|
|