Plan Review Details - Permit 15110949
| Plan Review Stops For Permit 15110949 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2015-12-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-12-05 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-12-05 |
Time |
13:30 |
Sent To |
|
|
| Notes |
| 2015-12-05 13:31:42 | FBC 5TH EDITION ACCESSIBILITY 604.4, SEAT HEIGHT OF A | | | WATER CLOSET ABOVE THE FINISHED FLOOR SHALL BE 17" | | | MINIMUM AND 19" MAXIMUM MEASURED TO THE TOP OF THE | | | SEAT. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2015-12-17 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2015-12-17 |
Time |
17:53 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2015-12-17 |
Time |
17:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2015-11-30 |
|
|
Cont ID |
|
| Sent By |
J.Walker |
Date |
2015-11-30 |
Time |
|
Rev Time |
0.35 |
| Received By |
|
Date |
2015-11-25 |
Time |
|
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-12-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-12-28 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-12-23 |
Time |
08:38 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-12-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-12-18 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-11-23 |
Time |
09:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2015-12-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-12-28 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-12-28 |
Time |
11:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2015-12-07 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-12-07 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-12-07 |
Time |
10:43 |
Sent To |
|
|
| Notes |
| 2015-12-07 11:10:04 | 1ST REVIEW 2014 MECHANICAL | | | PERMIT #15110949 | | | 12/7/15 | | | | | | 1) EXHAUST HAS BEEN PROVIDED FOR THE ENCLOSED TOILET | | | ROOM, HOWEVER NO EXHAUST IS SHOWN FOR THE REMAINDER OF | | | THE MEN'S ROOM CONTAINING THE URINALS- REFER TO TABLE | | | 403.3 AND PROVIDE A MINIMUM 50 CFM FAN. | | | 2) A DUCT SMOKE DETECTOR IS REQUIRED TO BE INSTALLED IN | | | THE RETURN AIR SYSTEM OF THE RTU- SEE SECTION 606.2.1.= | | | 3) PROVIDE A MEANS OF RETUN AIR FROM THE HALLWAY BACK | | | TO THE RTU- SEE SECTION 601.5. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2015-12-06 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-12-06 |
Time |
06:42 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-12-06 |
Time |
06:03 |
Sent To |
|
|
| Notes |
|
|
|