Plan Review Details - Permit 15110938
Plan Review Stops For Permit 15110938
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-03-17 Cont ID  
Sent By jwitmer Date 2016-03-17 Time 07:00 Rev Time 0.00
Received By jwitmer Date 2016-03-17 Time 06:41 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-12-08 Cont ID  
Sent By jwitmer Date 2015-12-08 Time 17:59 Rev Time  
Received By jwitmer Date 2015-12-08 Time 17:20 Sent To E
Notes
2015-12-08 17:37:29BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15110938
 ADD: 101 N. CLEMATIS ST. SUITE # 410
 CONT: LANDMAR DEVELOPMENT
 TEL: 561-685-1459
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
  
 1ST REVIEW
 DATE: TUESDAY DEC. 08/2015
 ACTION: DENIED
  
 1) THE PLANS INDICATE TO REMOVE TILE FLOORS IN BATHROOM
 AND INSTALL NEW TILE FLOORING. PLEASE SHOW COMPLIANCE
 WITH THE CODE SECTIONS BELOW. WE WILL NEED THE ACTUAL
 TEST, NOT A SALES BROCHURE.
  
 BLDG TYPE: TYPE I/ TYPE II FLOOR INSULATION (FBC-B
 2014)
  
 1A) FBC-B 2014 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
 1B) FBC-B 2014 1207.2 AIR-BORNE SOUND.
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
  
 1C) FLAME SPREAD- FBC-B 2014 603.1. EXCEPTION 2.
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200.
  
 FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS
 A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL
 MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A
 MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2015-12-29 Cont ID  
Sent By skennedy Date 2015-12-29 Time 13:20 Rev Time 0.00
Received By skennedy Date 2015-12-29 Time 13:20 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-03-17 Cont ID  
Sent By   Date 2016-03-17 Time 07:00 Rev Time 0.00
Received By lmarchan Date 2016-03-16 Time 14:43 Sent To  
Notes
2016-03-16 14:43:43RESUB ROUTED TO JWITMER

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-12-29 Cont ID  
Sent By skennedy Date 2015-12-29 Time 13:20 Rev Time 0.00
Received By skennedy Date 2015-11-23 Time 10:23 Sent To  
Notes
2015-11-24 10:25:04B02

Review Stop P PLUMBING
Rev No 1 Status P Date 2015-11-30 Cont ID  
Sent By gjohnson Date 2015-11-30 Time 16:07 Rev Time 0.00
Received By gjohnson Date 2015-11-30 Time 16:07 Sent To  
Notes
***NONE***