Plan Review Details - Permit 15110722
Plan Review Stops For Permit 15110722
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2016-01-25 Cont ID  
Sent By jwitmer Date 2016-01-25 Time 07:59 Rev Time 0.00
Received By jwitmer Date 2016-01-25 Time 07:29 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2015-12-07 Cont ID  
Sent By jwitmer Date 2015-12-07 Time 11:40 Rev Time 0.00
Received By jwitmer Date 2015-12-07 Time 11:40 Sent To  
Notes
2015-12-07 11:44:28BUILDING PLAN REVIEW
 W. P. B. REVISION: 15110722
 W. P. B. PERMIT: 15040016
 ADD: 701 N. ROSEMARY AVE.
 CONT: ADVANCED CONSTRUCTION
 TEL: (561)262-6037
 E-MAIL:
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: MON. DEC. 07/2015
 ACTION: DENIED
  
 NOTICE!!!!!!!!!!!!! CHAPTER 553.80(2)(B) FLORIDA
 STATUTES STATES THAT A LOCAL GOVERNMENT SHALL IMPOSE A
 FEE OF FOUR TIMES THE FEE FOR PLAN REVIEW, IF PLANS ARE
 REJECTED (3) OR MORE TIMES FOR REPEATED FAILURE TO
 CORRECT A CODE VIOLATION.
  
 1) SHEET AD 201 SHOWS THE ACCESSIBLE RESTROOM BEING
 RELOCATED AND A REDUCTION IN LENGTH OF THE RESTROOM
 FROM 7'-9 3/4 " TO JUST 7'-0" CLEAR INSIDE DIMENSIONS.
 FAILURE TO COMPLY WITH 2010 FBC-ACCESSIBLITY CODE
 604.3.1 SIZE. CLEARANCE AROUND A WATER CLOSET SHALL BE
 60 INCHES (1525 MM) MINIMUM MEASURED PERPENDICULAR FROM
 THE SIDE WALL AND 56 INCHES (1420 MM) MINIMUM MEASURED
 PERPENDICULAR FROM THE REAR WALL. ALSO SEE 604.2 FIGURE
 (A).
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-11-20 Cont ID  
Sent By tklarge Date 2015-11-20 Time 12:13 Rev Time 0.00
Received By jwitmer Date 2015-11-20 Time 07:19 Sent To P
Notes
2015-11-20 07:33:14BUILDING PLAN REVIEW
 W. P. B. REVISION: 15110722
 W. P. B. PERMIT: 15040016
 ADD: 701 N. ROSEMARY AVE.
 CONT: ADVANCED CONSTRUCTION
 TEL: (561)262-6037
 E-MAIL:
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: FRI. NOV. 20/2015
 ACTION: DENIED
  
 1) SHEET AD 201 SHOWS THE ACCESSIBLE RESTROOM BEING
 RELOCATED AND A REDUCTION IN LENGTH OF THE RESTROOM
 FROM 7'-9 3/4 " TO JUST 7'-0" CLEAR INSIDE DIMENSIONS.
 FAILURE TO COMPLY WITH 2010 FBC-ACCESSIBLITY CODE
 604.3.1 SIZE. CLEARANCE AROUND A WATER CLOSET SHALL BE
 60 INCHES (1525 MM) MINIMUM MEASURED PERPENDICULAR FROM
 THE SIDE WALL AND 56 INCHES (1420 MM) MINIMUM MEASURED
 PERPENDICULAR FROM THE REAR WALL. ALSO SEE 604.2 FIGURE
 (A).
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2016-01-26 Cont ID  
Sent By tklarge Date 2016-01-26 Time 14:46 Rev Time 0.00
Received By tklarge Date 2016-01-25 Time 11:38 Sent To  
Notes
2016-01-26 11:38:45RESUB ROUTED TO TKLARGE

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2016-01-25 Cont ID  
Sent By   Date 2016-01-25 Time 07:59 Rev Time 0.00
Received By lmarchan Date 2016-01-20 Time 14:37 Sent To  
Notes
2016-01-21 14:37:32RESUB ROUTED TO TKLARGE

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-12-07 Cont ID  
Sent By   Date 2015-12-07 Time   Rev Time 0.00
Received By lmarchan Date 2015-11-30 Time 16:44 Sent To  
Notes
2015-11-30 16:44:39RESUB ROUTED TO TKLARGE

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-11-20 Cont ID  
Sent By tklarge Date 2015-11-20 Time 12:13 Rev Time 0.00
Received By tklarge Date 2015-11-17 Time 16:35 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status P Date 2016-01-26 Cont ID  
Sent By tklarge Date 2016-01-26 Time 14:46 Rev Time 0.00
Received By tklarge Date 2016-01-26 Time 14:41 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2016-01-22 Cont ID  
Sent By tklarge Date 2016-01-22 Time 06:39 Rev Time 0.00
Received By tklarge Date 2016-01-22 Time 06:34 Sent To  
Notes
2016-01-22 06:39:091) SUBMIT A REVISED WATER RISER FOR REVIEW. WPB AMEND.
 TO FBC SEC. 107.3.5.1.3. 2ND REQUEST.
 2) SIZE ALL SECTIONS OF THE SANITARY SYTEM BELOW THE
 SLAB. WPB AMEND. TO FBC SEC. 107.3.5.1.3.
 3) IDENTIFY ALL PLUMBING FIXTURES ON THE RISER. WATER
 CLOSETS HAVE INTEGRAL TRAPS.
 4) FLAT, DRY VENTS ARE NOT PERMITTED PER 2014
 FBC-PLUMBING SEC.905.3.
 5) THE SANITARY RISER SHOWS A DRAIN LINE THAT CONNECTS
 TO NOTHING. CLARIFY.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2015-12-01 Cont ID  
Sent By tklarge Date 2015-12-01 Time 07:33 Rev Time 0.00
Received By tklarge Date 2015-12-01 Time 06:26 Sent To  
Notes
2015-12-01 06:47:15COMMENTS FROM THE PREVIOUS PLUMBING REVIEW HAVE NOT
 BEEN ADDRESSED.
 1) SUBMIT A SANITARY AND WATER RISER DIAGRAM FOR THE
 RE-LOCATION OF THE RESTROOMS. WPB AMEND. TO FBC SEC.
 107.3.5.1.3. 2ND REQUEST.
 2) THE MINIMUM INSIDE CLEAR WIDTH OF THE ACCESSIBLE
 TOILET ROOM SHALL BE 85 INCHES IF BUILT PERFECT. 86
 INCHES ALLOWS FOR TOLERANCE. THE PLAN SHOWS A MINIMUM
 INSIDE CLEAR WIDTH OF 84 INCHES WHICH IS NON-COMPLIANT.
 2ND REQUEST.
 3) THE WATER CLOSET SHALL BE LOCATED 16"-18" FROM AN
 ADJACENT WALL, NOT 18" MINIMUM AS IS SHOWN ON THE PLAN
 VIEW DETAIL IN THE ADA REQS.ON THE PLAN. 2010
 FBC-ACCESS. SEC.604.2.
 4) THE PLANS NEED TO BE CORRECTED.
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2015-11-20 Cont ID  
Sent By tklarge Date 2015-11-20 Time 12:13 Rev Time 0.00
Received By tklarge Date 2015-11-20 Time 12:05 Sent To  
Notes
2015-11-20 12:12:481) SUBMIT A SANITARY AND WATER RISER DIAGRAM FOR THE
 RE-LOCATION OF THE RESTROOMS. WPB AMEND. TO FBC SEC.
 107.3.5.1.3.
 2) THE MINIMUM INSIDE CLEAR WIDTH OF THE ACCESSIBLE
 TOILET ROOM SHALL BE 85 INCHES IF BUILT PERFECT. 86
 INCHES ALLOWS FOR TOLERANCE.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  