| Plan Review Stops For Permit 15110375 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2016-03-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-03-08 |
Time |
08:31 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-03-08 |
Time |
08:31 |
Sent To |
|
|
| Notes |
| 2016-03-08 08:32:49 | REVIEWED HAZARDOUS CHEMICAL INVENTORY/USE LETTER | | | PROVIDED BY ARCHITECT, STEVEN E. MYOTT | | | FORWARDED LETTER TO FIRE (PER PETER LEDUC, A REVIEW OF | | | HAZARDOUS CHEMICAL REQUIREMENTS WILL BE PERFORMED AT | | | INSPECTION) | | | PROVISO; ORIGINAL SIGNED, SEALED LETTER TO BE SENT VIA | | | MAIL FOR OUR RECORDS | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2016-02-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-02-03 |
Time |
12:55 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-02-02 |
Time |
18:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-11-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-11-21 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-11-21 |
Time |
15:01 |
Sent To |
|
|
| Notes |
| 2015-11-21 15:24:58 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. REVISE PLAN TO INCLUDE THE CHANGE OF OCCUPANCY FROM | | | S2 (PERMIT 05020247) TO BUSINESS OCCUPANCY, FBC 107. | | | | | | 2. FBC 2014 ACCESSIBILITY TABLE 404.2.4.1, 18IN | | | MANEUVERING CLEARANCE REQUIRED FOR DOORS 01 AND 02, | | | PULL SIDE. | | | | | | 3. SEE PAGE A0.01 OF PERMIT #05020247. SHEET CVR | | | SUBMITTED DECLARES A IIIB BUILDING TYPE, BUT THE | | | BUILDING WAS CONSTRUCTED AS TYPE V. A TYPE IIIB | | | REQUIRES 2 HOUR EXTERIOR WALLS. | | | | | | THE WEST WALL IS A 1 HOUR RATED WALL BASED ON DISTANCE | | | TO ASSUMED PROPERTY LINE. PLEASE REVISE BUILDING TYPE | | | TO TYPE V OR SHOW COMPLIANCE WITH TYPE IIIB BUILDING | | | TYPE (TABLE 601, 602, 705.8). | | | | | | 4. USE OF MEZZANINE IS NOT CLEAR. SEE FBC 2014 | | | ACCESSIBILITY 201.1.1 AND REVISE PLAN TO INCLUDE | | | EXCEPTION TO VERTICAL ACCESSIBILITY (OR PROVIDE | | | VERTICAL ACCESSIBILITY). | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2016-02-22 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-02-22 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-02-22 |
Time |
13:38 |
Sent To |
|
|
| Notes |
| 2016-02-22 13:42:14 | REVIEW 2014 5TH FBC ED. NEC 2011 | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 516-805-6713 | | | [email protected] | | | | | | | | | - MISSING SUM ELECTRICAL SHEETS PLS CLARIFY. | | | - EXIT & EMERGENCY LIGHTING LOCATIONS TO BE VERIFIED AT | | | THE TIME OF INSPECTIONS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2015-12-07 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2015-12-07 |
Time |
11:18 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2015-12-07 |
Time |
11:18 |
Sent To |
|
|
| Notes |
| 2015-12-07 13:19:28 | 1ST REVIEW: FBC 2014 5TH ED. NEC 2011 | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 516-805-6700 | | | [email protected] | | | ALTERNATE CONTACT | | | PHIL PETTY | | | 561-805-6742 | | | [email protected] | | | | | | | | | THE ELECTRICAL REVIEW IN ENTIRETY IS RESERVED PENDING | | | RESPONSES TO FIRE , BUILDING , AND MECHANICAL REVIEW | | | COMMENTS REGARDING FIRE PENETRATIONS ON WALLS AND | | | PARTITION. | | | PLAN E 1 SHOWS 400 AMP PANEL AS EXISTING AND I BELIEVE | | | ITS NEW ACCORDING TO THE SCOPE OF WORK. | | | PLAN E 3 PLEASE SHOW EMERGENCY LIGHTING IN STAIRS FBC | | | 1006 NEC 700.16 | | | FBC 1006.1 MEANS OF EGRESS ILLUMINATION. | | | FBC 1006.1.1 PER FBC-R, T-E3403 | | | ILLUMINATION OF MEANS OF EGRESS SHALL BE PROVIDED IN | | | ACCORDANCE WITH THIS SECTION FOR EVERY BUILDING AND | | | STRUCTURE. | | | 700.16 EMERGENCY ILLUMINATION. EMERGENCY ILLUMINATION | | | SHALL INCLUDE ALL REQUIRED MEANS OF EGRESS LIGHTING, | | | ILLUMINATED | | | EXIT SIGNS, AND ALL OTHER LIGHTS SPECIFIED AS NECESSARY | | | TO PROVIDE REQUIRED ILLUMINATION. | | | PROVIDE MANUFACTURE SPECS ON AC EQUIPMENT. | | | | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2016-01-27 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2016-01-27 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2016-01-26 |
Time |
14:45 |
Sent To |
|
|
| Notes |
| 2016-01-27 09:44:30 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | 1. SHEET E 4 - EXIT AND EMERGECNY LIGHTS ARE NOT | | | INDICATED ON THE SHEET. THEY ARE SHOWN AS EXISTING ON M | | | 1-1, 1-2. EXISTING EXIT AND EMERGENCY LIGHTS WILL BE | | | VERIFIED AND CONFIRMED ON FINAL INSPECTION. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2015-11-20 |
|
|
Cont ID |
|
| Sent By |
GJT |
Date |
2015-11-20 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
2015-11-20 |
Time |
|
Sent To |
|
|
| Notes |
| 2015-11-20 11:50:09 | 1. PROVIDE RAILING DETAIL FOR MEZZANINE | | | 2. PROVIDE DOOR RATINGS FOR DOORS 04, 05, 06 | | | 3. PROVIDE STAIR DETAIL | | | 4. PROVIDE RATING OF WAREHOUSE WALL THAT PROVIDES | | | SEPARATION TO THE OFFICE SPACE | | | 5. PROVIDE RATING OF STORAGE ROOM WALL THAT PROVIDES | | | SEPERATION FROM THE OFFICE SPACE | | | 6. REVIEW / REVISE FIRST FLOOR EGRESS PLAN (CAN NOT | | | EGRESS FROM LOWER HAZARD THROUGH HIGHER HAZARD | | | 7. STORAGE SHOW UNDER STAIR. PROVIDE DETAIL OF | | | PROTECTION (SPRINKLER, ETC..) | | | 8. SPRINKLER MODIFICATIONS MAY BE NEEDED. HAVE | | | EVALUATED. IF NEEDED SUBMIT UNDER SEPERATE PERMIT. | | | 9. FIRE ALARM MODIFICATIONS MAY BE NEEDED TO MEET | | | NOTIFICATION REQUIREMENTS, HAVE EVALUATED. IF NEEDED | | | SUBMIT UNDER SEPERATE PERMIT. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-03-08 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-03-08 |
Time |
09:47 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-01-19 |
Time |
13:48 |
Sent To |
|
|
| Notes |
| 2016-03-08 08:33:13 | 3/8/16 ROUTED PLAN TO CCOLE DESK | | | | | 2016-02-29 07:40:09 | 2/29 ON SH DESK PENDING RECEIPT OF EMAIL FROM ARCHITECT | | | | | | | | 2016-01-20 13:48:13 | B26 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-12-07 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2015-12-07 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2015-11-09 |
Time |
09:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2016-03-08 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-03-08 |
Time |
09:47 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-03-08 |
Time |
09:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2015-11-20 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-11-20 |
Time |
14:51 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-11-20 |
Time |
14:51 |
Sent To |
|
|
| Notes |
| 2015-12-07 12:06:54 | C | | 2015-11-20 15:36:36 | 1ST REVIEW 2014 MECHANICAL | | | PERMIT #15110375 | | | 11/20/15 | | | | | | 1) THE MECHANICAL REVIEW IN ENTIRETY IS RESERVED | | | PENDING RESPONSES TO FIRE AND BUILDING PLAN REVIEWS | | | COMMENTS REGARDING FIRE-RATED WALLS AND PARTITIONS. | | | PLEASE NOTE THAT FIRE DAMPERS MAY BE REQUIRED FOR AC | | | DUCTS PENETRATING THESE WALLS AND PARTITIONS, ALONG | | | WITH OTHER CODE COMPLIANCES. | | | 2) SUBMIT AC COOLING AND HEATING CALCULATIONS FOR THE | | | NEW AC-2 MINI-SPLIT SYSTEM IN THE STORAGE ROOM- SEE | | | SECTION C403.2.1 FBC-14 ENERGY CONSERVATION. | | | 3) PROVIDE ENERGY CALCULATIONS- REFER TO SECTION C101.2 | | | FBC-14 ENERGY CONSERVATION | | | 4) M1-1: PROVIDE WIND LOAD ENGINEERING AND DESIGN | | | CRITERIA FOR INSTALLATION OF THE NEW CONDENSER AND | | | EXHAUST FAN ON THE ROOF- SECTION 301.15 FBC-14 | | | MECHANICAL | | | 5) M1-1 & M1-3: EF-2 IS INDICATED AS SERVICING THE | | | WAREHOUSE IN THE EQUIPMENT SCHEDULE BUT APPEARS TO BE | | | OVER THE LAB IN THE ROOF DRAWING: PLEASE CLARIFY OR | | | CORRECT. | | | 6) M1-1 & M1-2: SHOW THE LOCATIONS OF KEY NOTES 6, 8, & | | | 16. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2016-01-24 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-01-24 |
Time |
03:49 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-01-24 |
Time |
03:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2015-11-21 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-11-21 |
Time |
05:04 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-11-21 |
Time |
04:28 |
Sent To |
|
|
| Notes |
| 2015-11-21 04:59:36 | 1) SHT. P-1 SHOWS THE SANITARY TO THE SINKS AS 4 INCH | | | AND SHT. P-2 SHOW 3 INCH. CLARIFY. | | | 2) SHT. P-1 SHOWS THE SANITARY TO THE EDF AS 3 INCH AND | | | SHT. P-2 SHOWS 2 INCH. CLARIFY. | | | 3) SHT. P-2 - PART OF THE WATER RISER IS CUT OFF. | | | SUBMIT A COMPLETE WATER RISER DIAGRAM FOR REVIEW THAT | | | SHOWS ALL THE PLUMBING FIXTURES. WPB AMEND. TO FBC SEC. | | | 107.3.5.1.3. | | | 4) A MINIMUM OF 2 DRINKING FOUNTAINS ARE REQD.ON AN | | | ACCESSIBLE LEVEL PER THE 2014 FBC-ACCESSIBILITY SEC. | | | 211.2. | | | 5) HOT WATER SHALL BE SUPPLIED TO THE HAND SINK, BREAK | | | ROOM SINK AND THE JANITOR SINK PERR THE 2014 | | | FBC-PLUMBING SEC.607.1. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | | | | | | | | | | | | | |
|
|