Plan Review Details - Permit 15110038
Plan Review Stops For Permit 15110038
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-11-03 Cont ID  
Sent By jwitmer Date 2015-11-03 Time 07:00 Rev Time 0.00
Received By jwitmer Date 2015-11-03 Time 06:42 Sent To  
Notes
2015-11-03 06:44:38 
 BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15110038
 ADD: 1801 S. FLAGLER DR/ SUITE # 1807
 CONT: ADLER ASSOCIATES
 TEL: (561)586-1129
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. NOV. 03/2015
 ACTION: DENIED
  
 1) THE CONTRACTOR OF RECORD WHO DREW THE PLANS, WILL
 NEED TO TAKE OWNERSHIP OF THE PLANS. PRINT HIS NAME,
 SIGN HIS NAME AND PRINT HIS LICENSE NUMBER ON THE PLANS
 HE DREW.
 107.2.1. CONSTRUCTION DOCUMENTS. ALL INFORMATION,
 DRAWINGS, SPECIFICATIONS AND ACCOMPANYING DATA SHALL
 BEAR THE NAME AND SIGNATURE OF THE PERSON RESPONSIBLE
 FOR THE DESIGN.
  
 2) 107.2.1.4 QUALITY OF BUILDING PLANS. BUILDING PLANS
 SHALL BE DRAWN TO A MINIMUM 1/8 INCH SCALE UPON
 SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE MEDIUM.
 THE BUILDING OFFICIAL MAY ESTABLISH THROUGH
 DEPARTMENTAL POLICY, OTHER STANDARDS FOR PLANS AND
 SPECIFICATIONS, IN ORDER TO PROVIDE CONFORMITY TO ITS
 RECORD RETENTION PROGRAM. THIS POLICY MAY INCLUDE SUCH
 THINGS AS MINIMUM SIZE, SHAPE, CONTRAST, CLARITY, OR
 OTHER ITEMS RELATED TO RECORDS MANAGEMENT. ELECTRONIC
 MEDIA MUST BE COMPATIBLE WITH THE ARCHIVE REQUIREMENTS
 OF FLORIDA STATUTES.
  
 3) THE PLANS INDICATE THE INSTALATION OF TILE FLOORS
 PLEASE PROVIDE COMPLIANCE WITH:
 BLDG TYPE: TYPE I/ TYPE II FLOOR INSULATION (FBC-B
 2014)
  
 3A) FBC-B 2014 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
 3B) FBC-B 2014 1207.2 AIR-BORNE SOUND.
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
  
 3C) FLAME SPREAD- FBC-B 2014 603.1. EXCEPTION 2.
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200.
  
 FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS
 A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL
 MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A
 MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
  
 4) THE PERMIT APPLICATION ALSO INDICATES THE REFRAMEING
 OF A DROPPED CEILLING. NO DETAILS PLEASE PROVIDE A
 DRAWING WITH: TYPE OF FRAMING MATERIAL, GAUGE OF METAL,
 SIZE OF STUD, SPAN OF DROP, CENTER TO CENNTER SPACING
 OF FRAMING MEMBERS, IF STIFF BACK IS REQUIRED OR MID
 SPAN DROPS, TYPE OF FASTENERS, TYPE OF FINISH ON DROP
 CEILING. 2014 FBC-B 2508.1 STEEL FRAMING FOR GYPSUM
 BOARD. ASTM C 754.
  
 5) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2015-11-03 Cont ID  
Sent By skennedy Date 2015-11-03 Time 17:56 Rev Time 0.00
Received By skennedy Date 2015-11-03 Time 17:56 Sent To  
Notes
2015-11-03 17:56:35SEE 15101013

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2015-11-05 Cont ID  
Sent By fstal Date 2015-11-05 Time   Rev Time 0.00
Received By fstal Date 2015-11-05 Time 14:29 Sent To PC
Notes
2015-11-05 14:16:01PROVIDE DRAWINGS THAT INDICATE CORRECT DIMENSIONS AND
 SECTION VIEWS OF WORK. FIRE PROTECTION CONTRACTOR SHALL
 SUBMIT SHOP DRAWINGS FOR REVIEW. ALSO SEE COMMENTS FROM
 BUILDING DEPARTMENT.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-11-05 Cont ID  
Sent By fstal Date 2015-11-05 Time   Rev Time 0.00
Received By fstal Date 2015-11-02 Time 15:08 Sent To  
Notes
2015-11-02 15:57:45NEW LOCATION - B21
2015-11-02 15:09:02B14

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2015-11-03 Cont ID  
Sent By skennedy Date 2015-11-03 Time 17:50 Rev Time 0.00
Received By skennedy Date 2015-11-03 Time 17:50 Sent To  
Notes
2015-11-03 17:51:12THERE IS NO MECHANICAL IN THIS SCOPE OF WORK.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2015-11-03 Cont ID  
Sent By ccole Date 2015-11-03 Time 16:15 Rev Time 0.00
Received By ccole Date 2015-11-03 Time 16:15 Sent To  
Notes
2015-11-03 16:18:511ST REVIEW: FBC 2014 MECHANICAL
 PERMIT #15110038
 11/3/15
  
 1) PROVIDE A SCOPE OF WORK FOR MECHANICAL ON THE PLANS
 WITH CORRELATING DRAWINGS AND DETAILS. CLARIFY IF ANY
 ALTERATIONS ARE PROPOSED FOR THE EXISTING AC SYSTEM OR
 THE EXISTING BATH AND LAUNDRY EXHAUST SYSTEMS.
 2) REFER TO BUILDING REVIEW COMMENTS FOR PLAN SUBMITTAL
 COMPLIANCES.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 1 Status N Date 2015-11-03 Cont ID  
Sent By skennedy Date 2015-11-03 Time 17:56 Rev Time 0.00
Received By skennedy Date 2015-11-03 Time 17:56 Sent To  
Notes
2015-11-03 17:57:45SEE 15091137


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved