| Plan Review Stops For Permit 15101064 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2016-08-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-08-20 |
Time |
09:10 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-08-17 |
Time |
16:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2016-03-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-03-24 |
Time |
12:15 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-03-24 |
Time |
11:54 |
Sent To |
|
|
| Notes |
| 2016-03-24 11:59:53 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 15101064 | | | ADD: 112 N. DIXIE HWY. | | | CONT: THE PROTINUS CORP | | | TEL: (561)214-0123 | | | E-MAIL: THE [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 3RD REVIEW | | | DATE: THURS. MARCH 24/2016 | | | ACTION: DENIED | | | | | | NOTICE, ONLY ONE SET OF ARCHITECTURAL PLANS IN PACKAGE | | | DATED 10/22/15. NO NARRATIVE OF CORRECTIONS!!! | | | | | | NOTICE!!!!!!!!!!!!! CHAPTER 553.80(2)(B) FLORIDA | | | STATUTES STATES THAT A LOCAL GOVERNMENT SHALL IMPOSE A | | | FEE OF FOUR TIMES THE FEE FOR PLAN REVIEW, IF PLANS ARE | | | REJECTED (3) OR MORE TIMES FOR REPEATED FAILURE TO | | | CORRECT A CODE VIOLATION. | | | | | | | | | 1) COMPLIED. INCREASED OCCUPANT LOAD. | | | | | | 2) COMPLIED. WORK AREA METHOD LEVEL II. | | | | | | 3) 3RD REQUEST. SHEET A-2 SHOWS THE BACK DOORS SWINGING | | | OUT. PLEASE PROVIDE A SURVEY THAT SHOWS THE PROPERTY | | | LINE. | | | DOORS CANNOT SWING OUT OVER THE PROPERTY LINE. 2014 | | | FBC-B 3202.2. | | | | | | 4) 3RD REQUEST. NEW COVERSHEET AND A1-A4 DRAWINGS. THE | | | CONTRACTOR FAILED TO COLATE THE OLD PLANS WITH THE NEW | | | PLANS SHEET A5-A8. SHEET A5 DOES SHOW A RECEPTION DESK, | | | NO HEIGHT HAS BEEN ASSIGNED TO THE DIAGRAM, PLEASE | | | PROVIDE COMPLIANCE WITH 2014 FBC-ACCESSIBILITY CODE | | | 904.4, 904.4.1 OR 904.4.2. | | | | | | 5) 3RD REQUEST. SHEET A5 NO ELEVATIONS HAVE BEEN | | | PROVIDED FOR THE BREAK ROOM SINK, PLEASE PROVIDE | | | COMPLIANCE WITH 2014 FBC-ACCESSIBILITY CODE 606.2 | | | THROUGH 606.5. | | | | | | 6) 3RD REQUEST, SHEET A5 NO ELEVATIONS HAVE BEEN | | | PROVIDED FOR THE JUICE BAR. SHEET A2 SHOWS DETAILS ON | | | A5 DETAILS K-M. PLEASE PROVIDE COMPLIANCE WITH THE 2014 | | | FBC-ACCESSIBILITY CODE 904.4, 904.4.1 OR 904.4.2. NOTE | | | IF THERE WILL BE TABLES THEN COMPLIANCE WITH 902.3 WILL | | | ALSO NEED TO COMPLIED WITH. | | | | | | 7) 3RD REQUEST. SHEET A-7 THE FINISH SCHEDULE THE | | | RESTROOMS WILL NEED TO SHOW COMPLIANCE WITH THE 2014 | | | FBC-B 1210.2.2. | | | | | | 8) PROVISO: TO BE REVIEWED UNDER A SEPARATE PERMIT. | | | PLEASE NOTE THERE WERE MECHANICAL PLANS PROVIDE, UNDER | | | THE MECHANICAL REVIEW EXHAUST AIR AND MAKE UP AIR WILL | | | NEED TO BE SUPPLIED TO THE MANICURE & PEDICURE | | | STATIONS. NORMALLY THESE FANS ARE MOUNTED ON THE ROOF | | | AND WILL NEED TO COMPLY WITH; | | | 8A) PROVISO: M- 301.15 WIND RESISTANCE. MECHANICAL | | | EQUIPMENT, APPLIANCES AND SUPPORTS THAT ARE EXPOSED TO | | | WIND SHALL BE DESIGNED AND INSTALLED TO RESIST THE WIND | | | PRESSURES DETERMINED IN ACCORDANCE WITH THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 8B) PROVISO:B-1609.6.4.4.1 COMPONENTS AND CLADDING. | | | WIND PRESSURE FOR EACH COMPONENT OR CLADDING ELEMENT | | | ARE TO BE DESIGNED FOR WIND PRESSURES COMPONENTS AND | | | ATTACHMENTS. | | | | | | 8C) PROVISO: 2010 FBC-B 1609.1.2 PROTECTION OF | | | OPENINGS, 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA | | | DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 | | | (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS | | | THAT WILL REQUIRE PRODUCT APPROVALS: | | | (31 ( C ) WALL LOUVERS | | | (D) ROOFING PRODUCTS AND ASSEMBLIES, ROOF TOP CURBS, | | | EXHAUST & INTAKE FANS | | | | | | 8D) PROVISO: 107.3.4.1 THOSE PRODUCTS WHICH ARE | | | REGULATED BY DCA RULE 9N-3SHALL BE REVIEWED AND | | | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO | | | SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | | | 9) 3RD REQUEST. WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2016-02-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-02-24 |
Time |
15:24 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-02-24 |
Time |
07:30 |
Sent To |
|
|
| Notes |
| 2016-02-24 15:24:38 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 15101064 | | | ADD: 112 N. DIXIE HWY. | | | CONT: THE PROTINUS CORP | | | TEL: (561)214-0123 | | | E-MAIL: THE [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: WED. FEB. 24/2016 | | | ACTION: DENIED | | | | | | 1) COMPLIED. INCREASED OCCUPANT LOAD. | | | | | | 2) COMPLIED. WORK AREA METHOD LEVEL II. | | | | | | 3) 2ND REQUEST. SHEET A-2 SHOWS THE BACK DOORS SWINGING | | | OUT. PLEASE PROVIDE A SURVEY THAT SHOWS THE PROPERTY | | | LINE. | | | DOORS CANNOT SWING OUT OVER THE PROPERTY LINE. 2014 | | | FBC-B 3202.2. | | | | | | 4) 2ND REQUEST. NEW COVERSHEET AND A1-A4 DRAWINGS. THE | | | CONTRACTOR FAILED TO COLATE THE OLD PLANS WITH THE NEW | | | PLANS SHEET A5-A8. SHEET A5 DOES SHOW A RECEPTION DESK, | | | NO HEIGHT HAS BEEN ASSIGNED TO THE DIAGRAM, PLEASE | | | PROVIDE COMPLIANCE WITH 2014 FBC-ACCESSIBILITY CODE | | | 904.4, 904.4.1 OR 904.4.2. | | | | | | 5) 2ND REQUEST. SHEET A5 NO ELEVATIONS HAVE BEEN | | | PROVIDED FOR THE BREAK ROOM SINK, PLEASE PROVIDE | | | COMPLIANCE WITH 2014 FBC-ACCESSIBILITY CODE 606.2 | | | THROUGH 606.5. | | | | | | 6) 2ND REQUEST, SHEET A5 NO ELEVATIONS HAVE BEEN | | | PROVIDED FOR THE JUICE BAR. SHEET A2 SHOWS DETAILS ON | | | A5 DETAILS K-M. PLEASE PROVIDE COMPLIANCE WITH THE 2014 | | | FBC-ACCESSIBILITY CODE 904.4, 904.4.1 OR 904.4.2. NOTE | | | IF THERE WILL BE TABLES THEN COMPLIANCE WITH 902.3 WILL | | | ALSO NEED TO COMPLIED WITH. | | | | | | 7) 2ND REQUEST. SHEET A-7 THE FINISH SCHEDULE THE | | | RESTROOMS WILL NEED TO SHOW COMPLIANCE WITH THE 2014 | | | FBC-B 1210.2.2. | | | | | | 8) PROVISO: TO BE REVIEWED UNDER A SEPARATE PERMIT. | | | PLEASE NOTE THERE WERE MECHANICAL PLANS PROVIDE, UNDER | | | THE MECHANICAL REVIEW EXHAUST AIR AND MAKE UP AIR WILL | | | NEED TO BE SUPPLIED TO THE MANICURE & PEDICURE | | | STATIONS. NORMALLY THESE FANS ARE MOUNTED ON THE ROOF | | | AND WILL NEED TO COMPLY WITH; | | | 8A) PROVISO: M- 301.15 WIND RESISTANCE. MECHANICAL | | | EQUIPMENT, APPLIANCES AND SUPPORTS THAT ARE EXPOSED TO | | | WIND SHALL BE DESIGNED AND INSTALLED TO RESIST THE WIND | | | PRESSURES DETERMINED IN ACCORDANCE WITH THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 8B) PROVISO:B-1609.6.4.4.1 COMPONENTS AND CLADDING. | | | WIND PRESSURE FOR EACH COMPONENT OR CLADDING ELEMENT | | | ARE TO BE DESIGNED FOR WIND PRESSURES COMPONENTS AND | | | ATTACHMENTS. | | | | | | 8C) PROVISO: 2010 FBC-B 1609.1.2 PROTECTION OF | | | OPENINGS, 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA | | | DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 | | | (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS | | | THAT WILL REQUIRE PRODUCT APPROVALS: | | | (31 ( C ) WALL LOUVERS | | | (D) ROOFING PRODUCTS AND ASSEMBLIES, ROOF TOP CURBS, | | | EXHAUST & INTAKE FANS | | | | | | 8D) PROVISO: 107.3.4.1 THOSE PRODUCTS WHICH ARE | | | REGULATED BY DCA RULE 9N-3SHALL BE REVIEWED AND | | | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO | | | SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | | | 9) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-11-09 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-11-09 |
Time |
15:22 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-11-09 |
Time |
14:20 |
Sent To |
|
|
| Notes |
| 2015-11-09 15:22:41 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 15101064 | | | ADD: 112 N. DIXIE HWY. | | | CONT: THE PROTINUS CORP | | | TEL: (561)214-0123 | | | E-MAIL: THE [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: MON. NOV. 09/2015 | | | ACTION: DENIED | | | | | | 1) THE COVERSHEET INDICATES THIS TENANT SPACE IS TO BE | | | A BUSINESS OCCUPANCY. THE LEASABLE SQ. FOOTAGE IS 2685 | | | S. F. THE OCCUPANT LOAD IS NOT GIVEN AND APPEARS THAT | | | IT WILL BE GREATER THAN 27 OCCUPANTS. THE DESIGNER OF | | | RECORD CAN PROVIDE AN INCREASED OCCUPANT LOAD SEE 2014 | | | FBC-B 1004.2. | | | | | | 2) THE COVERSHEET UNDER THE HEADING OF CODE COMPLIANCE | | | THE DESIGNER OF RECORD HAS NOT PROVIDED TO WHICH METHOD | | | OF DESIGN THE PLANS WERE DESIGN TO UNDER THE 2014 | | | EXISTING BUILDING CODE 301.1. APPLICATION OF A METHOD | | | SHALL BE THE SOLE BASIS FOR ASSESSING THE COMPLIANCE OF | | | WORK , SEE 301.1 THROUGH 301.1.3. THE DESIGNER IS TO | | | PICK A COMPLIANCE METHOD OF HOW THE PLANS WERE DERIVED. | | | | | | 3) SHEET A-2 SHOWS THE BACK DOORS SWINGING OUT. PLEASE | | | PROVIDE A SURVEY THAT SHOWS THE PROPERTY LINE. | | | DOORS CANNOT SWING OUT OVER THE PROPERTY LINE. 2014 | | | FBC-B 3202.2. | | | | | | 4) SHEET A5 DOES SHOW A RECEPTION DESK, NO HEIGHT HAS | | | BEEN ASSIGNED TO THE DIAGRAM, PLEASE PROVIDE COMPLIANCE | | | WITH 2014 FBC-ACCESSIBILITY CODE 904.4, 904.4.1 OR | | | 904.4.2. | | | | | | 5) SHEET A5 NO ELEVATIONS HAVE BEEN PROVIDED FOR THE | | | BREAK ROOM SINK, PLEASE PROVIDE COMPLIANCE WITH 2014 | | | FBC-ACCESSIBILITY CODE 606.2 THROUGH 606.5. | | | | | | 6)) SHEET A5 NO ELEVATIONS HAVE BEEN PROVIDED FOR THE | | | JUICE BAR. SHEET A2 SHOWS DETAILS ON A5 DETAILS K-M. | | | PLEASE PROVIDE COMPLIANCE WITH THE 2014 | | | FBC-ACCESSIBILITY CODE 904.4, 904.4.1 OR 904.4.2. NOTE | | | IF THERE WILL BE TABLES THEN COMPLIANCE WITH 902.3 WILL | | | ALSO NEED TO COMPLIED WITH. | | | | | | 7) SHEET A-7 THE FINISH SCHEDULE THE RESTROOMS WILL | | | NEED TO SHOW COMPLIANCE WITH THE 2014 FBC-B 1210.2.2. | | | | | | 8) PLEASE NOTE THERE WERE MECHANICAL PLANS PROVIDE, | | | UNDER THE MECHANICAL REVIEW EXHAUST AIR AND MAKE UP AIR | | | WILL NEED TO BE SUPPLIED TO THE MANICURE & PEDICURE | | | STATIONS. NORMALLY THESE FANS ARE MOUNTED ON THE ROOF | | | AND WILL NEED TO COMPLY WITH; | | | 8A) M- 301.15 WIND RESISTANCE. MECHANICAL EQUIPMENT, | | | APPLIANCES AND SUPPORTS THAT ARE EXPOSED TO WIND SHALL | | | BE DESIGNED AND INSTALLED TO RESIST THE WIND PRESSURES | | | DETERMINED IN ACCORDANCE WITH THE FLORIDA BUILDING | | | CODE, BUILDING. | | | 8B) B-1609.6.4.4.1 COMPONENTS AND CLADDING. WIND | | | PRESSURE FOR EACH COMPONENT OR CLADDING ELEMENT ARE TO | | | BE DESIGNED FOR WIND PRESSURES COMPONENTS AND | | | ATTACHMENTS. | | | | | | 8C) 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT | | | OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) | | | SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT | | | WILL REQUIRE PRODUCT APPROVALS: | | | (31 ( C ) WALL LOUVERS | | | (D) ROOFING PRODUCTS AND ASSEMBLIES, ROOF TOP CURBS, | | | EXHAUST & INTAKE FANS | | | | | | 8D) 107.3.4.1 THOSE PRODUCTS WHICH ARE REGULATED BY DCA | | | RULE 9N-3SHALL BE REVIEWED AND APPROVED IN WRITING BY | | | THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. | | | | | | 9) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2016-08-17 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-08-17 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-08-17 |
Time |
10:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2016-03-23 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-03-23 |
Time |
18:50 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-03-23 |
Time |
18:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2016-03-02 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-03-02 |
Time |
19:11 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-03-02 |
Time |
19:11 |
Sent To |
|
|
| Notes |
| 2016-03-02 19:15:17 | JOB PERMIT NUMBER: 15101064 | | | JOB ADDRESS: 112 N DIXIE HIGHWAY | | | WEST PALM BEACH | | | DATE: MARCH 2 2016 | | | ELECTRICAL PLAN REVIEW COMMENTS | | | | | | THE PLANS FOR THE ABOVE MENTIONED PERMIT APPLICATION | | | HAVE BEEN REVIEWED FOR COMPLIANCE WITH THE EDITION OF | | | THE NEC, (NATIONAL ELECTRICAL CODE) AND THE FBC, | | | (FLORIDA BUILDING CODE) AS WELL AS THE CITY OF WEST | | | PALM BEACH AMENDMENTS IN EFFECT AT THE TIME OF | | | SUBMITTAL. BELOW IS A LIST OF THE DEFICIENCIES NOTED. | | | - RISER DIAGRAM TO INCLUDE MAIN DISCONNECTING OF | | | SERVICE & FEEDER CONDUCTORS, AIC RATING OF ELECTRICAL | | | EQUIPMENT AND OCPD, GROUNDING DETAIL TO INCLUDE | | | GROUNDING ELECTRODE CONDUCTOR SIZE , FURTHER MORE | | | INTERSYSTEM BONDING REQUIRED. NEC 230.70 , 250.66 & 94 | | | , 215.5 , 110.9 & 10 | | | - ARC FLASH HAZARD WARNING LABEL REQUIRED AS WELL AS | | | AVAILABLE FAULT CURRENT MARKING. NEC 110.16, 110.24 | | | - PROVIDE DISCONNECTS ON FLOOR PLAN FOR W/H & A/C | | | EQUIPMENT WITHIN SIGHT. WBA 107. A SERVICE RECEPTACLE | | | IS REQUIRED BY MECHANICAL UNIT FOR MAINTENANCE PURPOSES | | | NEC 210.63 | | | - GFCI PROTECTION WITHIN 6 FT OF SINKS AND ALL KITCHEN | | | COUNTERTOPS IN OTHER THAN DWELLING UNITS NEC 210.8 B. | | | IN ADDITION MAKE SURE DRINKING FOUNTAIN IS ALSO GFCI | | | PROTECTED NEC 422.52 | | | - PROVIDE SHOW WINDOW OUTLETS PER NEC 210.62 AS WELL | | | AS DEDICATED SIGN CIRCUIT PER NEC 600.5 | | | - ALL ELECTRICAL APPARATUS SHALL BE PROPERLY MARKED AS | | | TO INDICATE WERE IN THE BUILDING IS THE SOURCE OF | | | SUPPLY AT ALL LOCATIONS IN THE SYSTEM. NEC 408.4 B | | | - NEC 700.12 (F) (4) - EMERGENCY LIGHTING SHALL BE FED | | | BY LIGHTING CIRCUIT OF SAME LOCAL AREA. *IF 3 OR MORE | | | LIGHTING CIRCUITS SUPPLY THE AREA, EM LIGHTS MAY BE ON | | | OWN CIRCUIT. | | | - FBC-E C405.5. INTERIOR LIGHTING POWER REQUIREMENTS. A | | | BUILDING COMPLIES WITH THIS SECTION IF ITS TOTAL | | | CONNECTED LIGHTING POWER CALCULATED UNDER SECTION | | | C405.5.1 IS NO GREATER THAN THE INTERIOR LIGHTING POWER | | | CALCULATED UNDER SECTION C405.5.2. PROVIDE A LIGHTING | | | POWER DENSITY CHART TO SHOW COMPLIANCE. | | | - COMPLY WITH FBC ? E C 405 FOR OCCUPANCY SENSORS IN | | | BATHROOMS, DAYLIGHT ZONE CONTROLS BY FRONT WINDOWS , | | | DIMMER CONTROLS OR TANDEM WIRING LIGHTING REDUCTION TO | | | 50 %, TO ADD A FIXTURE SCHEDULE WITH MOUNTING DETAIL | | | SHALL BE PROVIDED. | | | | | | | | | | | | | | | PLEASE REVISE YOUR DRAWINGS TO REFLECT THE ABOVE | | | MENTIONED DEFICIENCIES. | | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | | RE-SUBMITTAL, YOU ARE REQUIRED TO PROVIDE A RESPONSE | | | LETTER (NARRATIVE) ADDRESSING EACH ITEM ALONG WITH THE | | | STANDARD CITY RE-SUBMITTAL FORM. THE NARRATIVE SHOULD | | | INCLUDE THE PLAN REVIEWER?S COMMENTS AND YOUR RESPONSE | | | OR ACTION TO SAME. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PAGES INTO THE SUBMITTAL AND LEAVE THE | | | PREVIOUSLY REVIEWED SHEETS FOR COMPARISON. | | | CLOUDING THE CHANGES WILL BE GREATLY APPRECIATED. | | | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | | CONTACT ME DIRECTLY. | | | | | | FBC 2014 5TH ED. NEC 2011 | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 516-805-6713 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2015-11-25 |
Time |
|
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2015-11-25 |
Time |
10:14 |
Sent To |
Z |
|
| Notes |
| 2015-11-25 10:53:36 | 1ST REVIEW: FBC 2014 5TH ED. NEC 2011/RESIDENTIAL | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 516-805-6700 | | | [email protected] | | | ALTERNATE CONTACT | | | PHIL PETTY | | | 561-805-6742 | | | [email protected] | | | | | | | | | | | | FBC- 107.3.5.3 ? ELECTRIC SERVICE RISER WITH WIRE | | | SIZES, CONDUIT DETAIL AND GROUNDING DETAIL. COMPLETE | | | LOAD CALCULATIONS, PANEL SCHEDULES AND SHOW CIRCUITS ON | | | FLOOR PLAN. | | | PLEASE PROVIDE ON PANEL SCHEDULE AND FLOOR PLAN | | | EXIT/EMERGENCY LIGHTS AHEAD OF LIGHTING CIRCUITS PER | | | ARTICLE 700 NEC 2011 | | | PLEASE PROVIDE AUTOMATIC LIGHTING SHUTOFF PER FBC | | | ENERGY CODE SECTION C405. | | | (B) OTHER THAN DWELLING UNITS. ALL 125-VOLT, | | | SINGLEPHASE, | | | 15- AND 20-AMPERE RECEPTACLES INSTALLED IN THE | | | LOCATIONS | | | SPECIFIED IN 210.8(B)(1) THROUGH (8) SHALL HAVE | | | GROUND-FAULT CIRCUIT-INTERRUPTER PROTECTION FOR | | | PERSONNEL. | | | (1) BATHROOMS | | | (2) KITCHENS | | | (3) ROOFTOPS | | | (4) OUTDOORS | | | (B) LOAD EVENLY PROPORTIONED AMONG BRANCH CIRCUITS. | | | WHERE THE LOAD IS CALCULATED ON THE BASIS OF | | | VOLT-AMPERES | | | PER SQUARE METER OR PER SQUARE FOOT, THE WIRING SYSTEM | | | UP TO | | | AND INCLUDING THE BRANCH-CIRCUIT PANELBOARD(S) SHALL BE | | | PROVIDED | | | TO SERVE NOT LESS THAN THE CALCULATED LOAD. THIS LOAD | | | SHALL BE EVENLY PROPORTIONED AMONG MULTIOUTLET BRANCH | | | CIRCUITS | | | WITHIN THE PANELBOARD(S). BRANCH-CIRCUIT OVERCURRENT | | | DEVICES AND CIRCUITS SHALL BE REQUIRED TO BE INSTALLED | | | ONLY TO | | | SERVE THE CONNECTED LOAD. | | | ARTICLE 210?BRANCH CIRCUITS 210.11 | | | 2011 | | | 210.62 SHOW WINDOWS. AT LEAST ONE RECEPTACLE OUTLET | | | SHALL BE INSTALLED WITHIN 450 MM (18 IN.) OF THE TOP OF | | | A | | | SHOW WINDOW FOR EACH 3.7 LINEAR M (12 LINEAR FT) OR | | | MAJOR | | | FRACTION THEREOF OF SHOW WINDOW AREA MEASURED | | | HORIZONTALLY | | | AT ITS MAXIMUM WIDTH. | | | . | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2016-08-23 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2016-08-23 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2016-08-22 |
Time |
14:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2016-02-18 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2016-02-18 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2016-02-18 |
Time |
10:09 |
Sent To |
|
|
| Notes |
| 2016-02-18 10:22:13 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | 1. MOVE REAR EXIT SIGN INTO THE HALLWAY SO IT CAN BE | | | SEEN FROM WITHIN THE SALON. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2015-11-04 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2015-11-04 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2015-11-04 |
Time |
10:15 |
Sent To |
|
|
| Notes |
| 2015-11-04 11:20:21 | 112 NORTH DIXIE HIGHWAY | | | PERMIT #15101064 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | UPDATE THE CODE LIST TO REFERENCE THE 5TH EDITION OF | | | THE FLORIDA FIRE PREVENTION CODE WHICH CONTAINS THE | | | 2012 EDITION OF BOTH NFPA 1 AND NFPA 101 WITH FLORIDA | | | AMENDMENTS. | | | | | | WHERE ARE ALL THE BUSINESS SUPPLIES TO BE LOCATED? PER | | | SECTION 8.7, ANY AREA (STORAGE) HAVING A DEGREE OF | | | HAZARD GREATER THAN NORMAL TO THE GENERAL OCCUPANCY | | | (BUSINESS) OF THE BUILDING, SHALL BE SEPARATED FROM | | | NON-STORAGE AREAS WITH A 1-HOUR FIRE-RATED BARRIER OR | | | BE PROTECTED WITH AN AUTOMATIC SPRINKLER SYSTEM. DOORS | | | SHALL BE SELF CLOSING, POSITIVE LATCHING, AND | | | FIRE-RATED FOR AT LEAST 45-MINUTES. | | | | | | PROVIDE AN OCCUPANT LOAD BREAKDOWN FOR EACH ROOM. | | | | | | FOR OCCUPANT LOADS OF 50 OR MORE PERSONS, DOORS SHALL | | | SWING IN THE DIRECTION OF EGRESS. | | | | | | PROVIDE TACTILE SIGNAGE AT ALL REQUIRED EXIT DOORS WITH | | | EXIT SIGNS. | | | | | | THE ELECTRICAL PLAN DOES NOT INCLUDE THE EMERGENCY | | | LIGHTING SHOWN ON THE LIFE SAFETY PLAN. | | | | | | NO MECHANICAL VENTILATION PLAN PROVIDED. | | | | | | WESLEY JOLIN | | | ASSISTANT FIRE MARSHAL | | | FIRE INVESTIGATOR & INSPECTOR | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 805-6730 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2016-11-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-11-28 |
Time |
09:40 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-11-22 |
Time |
08:17 |
Sent To |
|
|
| Notes |
| 2016-11-23 08:17:17 | RESUB ROUTED TO CCOLE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2016-11-18 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-11-18 |
Time |
12:18 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-11-14 |
Time |
11:43 |
Sent To |
|
|
| Notes |
| 2016-11-16 11:44:11 | RESUB ROUTED TO CCOLE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2016-09-16 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2016-09-16 |
Time |
15:04 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2016-08-16 |
Time |
16:18 |
Sent To |
|
|
| Notes |
| 2016-09-16 14:56:19 | TO LAURA MERCHANT | | 2016-08-16 16:19:02 | B34 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2016-04-11 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-04-11 |
Time |
12:49 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-03-22 |
Time |
13:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-03-17 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2016-03-17 |
Time |
09:26 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2016-02-12 |
Time |
09:11 |
Sent To |
|
|
| Notes |
| 2016-03-16 16:28:58 | TO CAROLINE FOR PROCESSING | | 2016-02-16 09:12:10 | B22 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-12-04 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2015-12-04 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2015-10-29 |
Time |
15:33 |
Sent To |
|
|
| Notes |
| 2015-12-04 14:03:22 | PERMIT FAILED- JOHN GAFFNEY CONTACTED BY PHONE ON | | | 12-4-15. | | 2015-10-30 15:35:02 | B13 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2016-11-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-11-28 |
Time |
09:39 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-11-28 |
Time |
09:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
F |
Date |
2016-11-18 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-11-18 |
Time |
12:19 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-11-18 |
Time |
12:19 |
Sent To |
|
|
| Notes |
| 2016-11-18 12:26:17 | 4TH REVIEW FBC-2014 MECHANICAL | | | PERMIT #15101064 | | | 11/18/16 | | | | | | 1) THE NEW 5-TON RTU REQUIRES INSTALLATION OF A DUCT | | | SMOKE DETECTOR IN THE RETURN AIR SYSTEM IN COMPLIANCE | | | WITH SECTION 606.2.1. PLEASE REVISE THE PLAN TO SHOW | | | THE LOCATION OF THE DEVICE AND TEST STATION, AND | | | PROVIDE NOTES TO INDICATE THE SEQUENCE OF OPERATION. | | | | | | 2) ALL REVISED PLAN SHEETS MUST BE PERMANENTLY ATTACHED | | | INTO THE PLAN SETS AND ALL SHEETS BEING REPLACED MUST | | | BE REMOVED FROM THE SETS, VOIDED, AND RETAINED IN THE | | | PERMIT PACKAGE FOR REFERENCE ONLY. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2016-08-24 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-08-24 |
Time |
08:50 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-08-24 |
Time |
08:50 |
Sent To |
|
|
| Notes |
| 2016-08-24 09:02:59 | 4TH REVIEW FBC-2014 MECHANICAL | | | PERMIT #15101064 | | | 8/24/16 | | | | | | 1) AS PREVIOUSLY REQUESTED, PROVIDE A SEQUENCE OF | | | OPERATION FOR THE SALON EXHAUST FANS. CLARIFY IF THE | | | FANS WILL BE ON SWITCHES, OR LINKED TO THE LIGHTS OR AC | | | SYSTEMS. | | | | | | 2) PROVIDE MAKE UP AIR AND A SEQUENCE OF OPERATION FOR | | | EF-1 IN THE STORAGE ROOM. CLARIFY THE PURPOSE OF THE | | | FAN AND PROVIDE A LIST OF MATERIALS AND QUANTITIES OF | | | MATERIALS TO BE STORED IN THE ROOM. PROVIDE MSDS SHEETS | | | FOR ANY HAZARDOUS TYPE MATERIALS, AND PROVIDE AN | | | EXHAUST VENTILATION CALCULATION- REFER TO SECTION 414 | | | FBC-14 BUILDING FOR APPLICABLE REQUIREMENTS. | | | | | | 3) PROVIDE WIND LOAD ENGINEERING FOR ANCHORAGE OF THE | | | EXHAUST FANS AND CURBS TO THE ROOF STRUCTURE- SECTION | | | 301.15. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2016-03-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-03-28 |
Time |
08:33 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-03-28 |
Time |
08:33 |
Sent To |
|
|
| Notes |
| 2016-03-28 08:49:28 | 3RD REVIEW: FBC 2014 MECHANICAL | | | PERMIT #151201064 | | | 3/28/16 | | | | | | 1) PROVIDE DRAWINGS AND DETAILS FOR THE NEW EXHAUST | | | SYSTEMS INDICATING THE LOCATIONS OF THE EXHAUST INLETS, | | | GRILL SIZES, GAGE OF METAL EXHAUST DUCT, AND FAN | | | SCHEDULES. PLEASE NOTE THAT THE ARCHITECTURAL PLANS | | | NEED TO BE REVISDED TO SHOW THE LOCATIONS OF, AND | | | CONSTRUCTION DETAILS FOR THE NEW KNEE WALLS AT THE NAIL | | | STATIONS. | | | 2) PROVIDE AN AIR BALANCE CALCULATION, AND A SEQUENCE | | | OF OPERATION FOR THE EXHAUST SYSTEM. | | | 3) PROVIDE A MECHANIOCAL ROOF PLAN INDICATING THE | | | LOCATIONS OF ALL ROOF TOP EQUIPMENT: SHOW CLEARANCE | | | DISTANCE MEASUREMENTS FOR AIR INTAKES TO EXHAUST AND | | | VENT OUTLETS, EQUIPMENT CLEARANC DISTANCES TO RROF | | | EDGES, AND THE NEW RTU CONDENSATE PIPING RUN. | | | 4) M-2: PROVIDE THE WIND LOAD DESIGN CRITERIA FOR | | | INSTALLATION OF THE RTU, AND PROVIDE DETAILS FOR | | | INSTALLATION OF THE NEW EXHAUST FANS. PLEASE SUBMIT | | | MIAMI-DADE NOA'S AND/OR FL. PRODUCT APPROVALS FOR THE | | | FANS AND CURBS WITH APPROVAL SIGNATURES BY THE ENGINEER | | | OF RECORD. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2016-02-24 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-02-24 |
Time |
18:00 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-02-24 |
Time |
18:00 |
Sent To |
|
|
| Notes |
| 2016-02-24 18:03:33 | MECHANICAL NOTE | | | PERMIT #15101064 | | | 2/24/15 | | | | | | 1) THE PLANS WERE RE-SUBMITTED A SECOND TIME WITHOUT | | | MECHANICAL PLANS. PER HAROLD MOSER THE PLANS WILL BE | | | SUBMITTED UNDER A SEPARATE PERMIT. I AM PLACING A HOLD | | | ON HE CO FOR THIS OCCUPANCY PENDING APPROVAL OF | | | MECHANICAL PLANS, AND COMPLETE INSPECTIONS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2015-11-06 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-11-06 |
Time |
12:55 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-11-06 |
Time |
12:55 |
Sent To |
|
|
| Notes |
| 2015-11-06 13:05:40 | 1ST REVIEW: FBC 2014 MECHANICAL | | | PERMIT #15101064 | | | 11/6/15 | | | | | | 1) NO MECHANICAL PLANS WERE INCLUDED WITH THE SUBMITTED | | | PLAN SETS FOR THE PROJECT. IN AN EFFORT TO EXPEDITE THE | | | PERMITTING PROCESS, I CALLED THE ENGINEER OF RECORD- | | | MR. KARL LEDERER WHO ACKNOWLEDGED THAT THERE WERE NO | | | PLANS AT THE PRESENT TIME TO BE SUBMITTED. I ADVISED | | | HIM TO REVIEW THE APPLICABLE CODE SECTIONS FOR NAIL | | | SALONS IN THE FBC-2014 MECHANICAL CODE AND SUBMIT PLANS | | | ACCORDINGLY. PLEASE REFER TO TABLE 403.3 | | | FBC-MECHANICAL- FOR THE MINIMUM VENTILATION RATES | | | INCLUDING FOOTNOTES B & H AND SECTION 403.2.1 ITEM #3- | | | ALL OF WHICH ARE APPLICABLE TO NAIL SALONS. PLEASE | | | PROVIDE COMPLETE HVAC PLANS, EQUIPMENT SCHEDULES, | | | INSTALLATION DETAILS, AND CALCULATIONS FOR REVIEW. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2016-09-10 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-09-10 |
Time |
08:20 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-09-10 |
Time |
07:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2016-04-11 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-04-11 |
Time |
12:48 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-04-11 |
Time |
12:48 |
Sent To |
|
|
| Notes |
| 2016-04-11 12:48:25 | PLUMBING COMMENTS; | | | | | | 1) SUBMIT TWO COPIES OF THE MANUF. SPECIFICATIONS & | | | INSTALLATION MANUAL FOR THE PEDICURE CHAIRS. WPB AMEND. | | | TO FBC SEC. 107.2.1. 2ND REQUEST | | | 2) THE BREAK ROOM SINK SHALL COMPLY WITH THE 2014 | | | FBC-ACCESSIBILITY SEC. 212, 212.3. 2ND REQUEST | | | 3) SHT. A-2 INDICATES ELEVATION 11 K11 ON SHT. A-5 FOR | | | THE BREAKROOM ELEVATIONS. THERE IS NO ELEVATION 11 K11 | | | ON SHT. A-5. CLARIFY. 2ND REQUEST | | | 4) SHT. A-7 - FINISH SCHEDULE - THE WALLS IN THE MEN?S | | | & WOMEN?S TOILET ROOMS SHALL COMPLY WITH 2014 FBC | | | SEC.1210.2.2. 2ND REQUEST | | | 5) WATER FOUNTAIN IS REQUIRED PER FBC PL SEC. 403.1 | | | TABLE 403.1 WATER FOUNTAINS SHALL COMPLY WITH FBC ACC. | | | SEC. 307 AND 602. | | | 6) SUBMIT AN OCCUPANT LOAD FOR THIS SPACE IN ACCORDANCE | | | WITH 2014 FBC TABLE 1004.1.2. 2ND REQUEST | | | 7) INDICATE ON THE PLAN WHAT TYPE OF | | | PRODUCTS/PREPARATION WILL BE DONE AT THE JUICE BAR .WPB | | | AMEND . TO FBC SEC. 107 .2.1. 2ND REQUEST | | | 8) A SERVICE SINK IS REQUIRED PER FBC PL SEC. 403.1 | | | TABLE 403.1 | | | 9) THE VENTING FOR PEDICURE CHAIRS SHALL COMPLY WITH | | | FBC PL SEC. 914.2 VENT CONNECTION. | | | THE CIRCUIT VENT CONNECTION SHALL BE LOCATED BETWEEN | | | THE TWO MOST UPSTREAM FIXTURE DRAINS. THE VENT SHALL | | | CONNECT TO THE HORIZONTAL BRANCH AND SHALL BE INSTALLED | | | IN ACCORDANCE WITH SECTION 905. THE CIRCUIT VENT PIPE | | | SHALL NOT RECEIVE THE DISCHARGE OF ANY SOIL OR WASTE. | | | | | | IT APPEARS THAT ONLY THE NEW MEP PAGES WERE RESUBMITED | | | PLEASE CLARIFY | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2016-02-20 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-02-20 |
Time |
08:26 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-02-20 |
Time |
07:50 |
Sent To |
|
|
| Notes |
| 2016-02-20 08:08:38 | 1) SUBMIT TWO COPIES OF THE MANUF. SPECIFICATIONS & | | | INSTALLATION MANUAL FOR THE PEDICURE CHAIRS. WPB AMEND. | | | TO FBC SEC. 107.2.1.2ND REQUEST. | | | 2) SUBMIT A WATER RISER DIAGRAM FOR REVIEW.SHOW ALL | | | PIPE SIZES ON THE SANITARY AND WATER RISER DIAGRAMS.WPB | | | AMEND. TO FBC SEC. 107.3.5.1.3. | | | 3) NOW THAT AN OCCUPANT LOAD HAS BEEN GIVEN, THE | | | FOLLOWING PLUMBING FIXTURES ARE REQUIRED PER 2014 FPC | | | TABLE 403.1: | | | A) A DRINKING FOUNTAIN IS REQUIRED. 2014 FPC TABLE | | | 403.1. A MINIMUM OF 2 DRINKING FOUNTAINS ARE REQUIRED | | | PER 2014 FAC SEC.211.2 & FPC TABLE 403.1 FOOTNOTE (E). | | | B) A SERVICE SINK IS REQUIRED PER 2014 FPC TABLE 403.1. | | | 4) PROVIDE A COST BREAKDOWN SHOWING THE PROPORTION OF | | | EXPENDITURES USED TO COMPLY WITH THE FBC-ACCESSIBILITY | | | FOR THE AMOUNT DEDICATED TO PROVIDING HANDICAP | | | ACCESSIBILITY. SEE FAC SECS.202.4.1 & 202.4.2. | | | | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2015-11-05 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-11-05 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-11-05 |
Time |
05:27 |
Sent To |
|
|
| Notes |
| 2015-11-05 10:44:44 | 1) SUBMIT TWO COPIES OF THE MANUF. SPECIFICATIONS & | | | INSTALLATION MANUAL FOR THE PEDICURE CHAIRS. WPB AMEND. | | | TO FBC SEC. 107.2.1. | | | 2) THE BREAK ROOM SINK SHALL CCOMPLY WITH THE 2014 | | | FBC-ACCESSIBILITY SEC. 212, 212.3. | | | 3) SHT. A-2 INDICATES ELEVATION "K" ON SHT. A-5 FOR THE | | | BREAKROOM ELEVATIONS. THERE IS NO ELEVATION "K" ON SHT. | | | A-5. CLARIFY. | | | 4) SHT. A-7 - FINISH SCHEDULE - THE WALLS IN THE MEN'S | | | & WOMEN'S TOILET ROOMS SHALL COMPLY WITH 2014 FBC | | | SEC.1210.2.2. | | | 5) SUBMIT A SANITARY AND WATER RISER DIAGRAM FOR | | | REVIEW.SHOW ALL PIPE SIZES ON THE RISER DIAGRAMS.WPB | | | AMEND. TO FBC SEC. 107.3.5.1.3. | | | 6) SUBMIT AN OCCUPANT LOAD FOR THIS SPACE IN ACCORDANCE | | | WITH 2014 FBC TABLE 1004.1.2. | | | 7) INDICATE ON THE PLAN WHAT TYPE OF | | | PRODUCTS/PREPARATION WILL BE DONE AT THE JUICE BAR.WPB | | | AMEND. TO FBC SEC. 107.2.1. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2016-09-16 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2016-09-16 |
Time |
14:51 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2016-09-16 |
Time |
14:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2016-03-16 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2016-03-16 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2016-03-16 |
Time |
16:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2015-12-04 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2015-12-04 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2015-12-04 |
Time |
13:59 |
Sent To |
|
|
| Notes |
|
|