| Plan Review Stops For Permit 15101055 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
N |
Date |
2016-01-05 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2016-01-05 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2016-01-05 |
Time |
15:51 |
Sent To |
I |
|
| Notes |
| 2016-01-05 16:27:57 | ELECTRICAL STOPS WERE INADVERTENTLY ADDED TO THIS | | | PERMIT. SHOULD THERE BE A CONNECTION OF THIS SYSTEM TO | | | AN EXISTING FIRE ALARM SYSTEM, A SEPARATE PERMIT FOR | | | THAT CONNECTION WILL BE REQUIRED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2015-12-30 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2015-12-31 |
Time |
11:25 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-12-30 |
Time |
18:07 |
Sent To |
I |
|
| Notes |
| 2015-12-30 19:22:49 | THE PLANS FOR THE ABOVE MENTIONED REVISION HAS BEEN | | | REVIEWED FOR COMPLIANCE WITH THE EDITION OF THE NEC, | | | (NATIONAL ELECTRICAL CODE), FIRE CODES AND THE FBC, | | | (FLORIDA BUILDING CODE) AS WELL AS THE CITY OF WEST | | | PALM BEACH AMENDMENTS IN EFFECT AT THE TIME OF | | | SUBMITTAL. BELOW IS A LIST OF THE DEFICIENCIES NOTED. | | | 1. YOU SHALL DEFINE YOUR SCOPE OF WORK AND INCLUDE IT | | | ON THE PLANS. I CAN?T DETERMINE IF THIS IS PREFAB UNIT | | | WITH A SINGLE POINT OF CONNECTION TO A FIELD PROVIDED | | | DISCONNECT, OR IF THIS IS A SITE BUILT UNIT IN WHICH | | | CASE FURTHER DETAILS SHALL BE PROVIDED. | | | 2. ACCORDING TO THE MANUFACTURERS SPEC SHEET, BOTH THE | | | EXHAUST AND SUPPLY FANS ARE 3 PHASE AND THE SERVICE TO | | | THE PREMISES ARE INDICATED ON THE RISER DIAGRAM IS | | | SINGLE PHASE. | | | 3. PROVIDE LITERATURE OR MANUFACTURERS SPEC SHEETS FOR | | | THE MOTORS, OR PROVIDE SOMETHING INDICATING WHETHER THE | | | VALUES EXPRESSED ON PAGE 3 ARE MOTOR FLC, OR OCP. | | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | | RE-SUBMITTAL, YOU ARE REQUIRED TO PROVIDE A RESPONSE | | | LETTER (NARRATIVE) ADDRESSING EACH ITEM ALONG WITH THE | | | STANDARD CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE | | | INSERT CORRECTED PAGES INTO THE SUBMITTAL PACKAGE. MARK | | | VOID AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR | | | COMPARATIVE REVIEW. CLOUDING THE CHANGES WILL BE | | | GREATLY APPRECIATED. | | | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | | CONTACT ME DIRECTLY. | | | | | | THANK YOU, | | | MIKE ALBARRAN | | | ELECTRICAL PLANS EXAMINER | | | PH.: 561-805-6746 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
N |
Date |
2015-11-30 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2015-11-30 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2015-11-30 |
Time |
10:09 |
Sent To |
|
|
| Notes |
| 2015-11-30 10:27:09 | 1ST REVIEW: FBC 2014 5TH ED. NEC 2011 | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 516-805-6700 | | | [email protected] | | | ALTERNATE CONTACT | | | PHIL PETTY | | | 561-805-6742 | | | [email protected] | | | | | | . CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | | OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL | | | CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, | | | AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS | | | ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. | | | | | | FBC 107.2.1.4 QUALITY OF BUILDING PLANS. BUILDING PLANS | | | SHALL BE DRAWN TO A MINIMUM 1/8 INCH SCALE UPON | | | SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE MEDIUM. | | | THIS POLICY MAY INCLUDE SUCH THINGS AS MINIMUM SIZE, | | | SHAPE, CONTRAST, CLARITY, OR OTHER ITEMS RELATED TO | | | RECORDS MANAGEMENT. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2015-12-31 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-12-31 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2015-12-28 |
Time |
14:11 |
Sent To |
|
|
| Notes |
| 2015-12-28 14:13:13 | INSUFFICIENT DETAIL ON RESUBMITTAL THAT WAS ATTACHED TO | | | 15101045 | | | | | | CONCERNS ADDRESSED AND PASSED 12/31/15. PML |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2015-11-04 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2015-11-04 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2015-11-04 |
Time |
10:15 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-01-05 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2016-01-05 |
Time |
16:29 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2016-01-05 16:31:30 | 1/5/16 THOUGH THIS PERMIT IS READY TO BE ISSUED, IT IS | | | RUNNING WITH 15101045 FOR THE SPRAY BOOTH AND THEY WILL | | | GO OUT TOGETHER. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-12-30 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-12-30 |
Time |
19:25 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-10-29 |
Time |
15:16 |
Sent To |
|
|
| Notes |
| 2015-12-30 19:26:45 | 12/30/15 FAILED THE LAST OF THE TRADE REVIEWS. | | | CONTRACTOR NOTIFIED VIA EMAIL. SENT TO SMALL DENIED BIN | | | "F". MA | | 2015-11-13 12:04:44 | B10 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2015-12-31 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-12-31 |
Time |
10:35 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-12-31 |
Time |
10:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2015-12-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-12-28 |
Time |
10:41 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-12-28 |
Time |
10:41 |
Sent To |
|
|
| Notes |
| 2015-12-28 10:53:01 | 2ND REVIEW 2014 MECHANICAL | | | PERMIT #15101055 | | | 12/28/15 | | | | | | 1) THE DIMENSIONS OF THE SPRAY BOOTH SHOWN ON THE FIRE | | | SUPPRESSION PLAN DOES NOT MATCH THE DIMENSIONS SHOWN ON | | | THE SPRAY BOOTH PLANS. PLEASE REVISE AND INCLUDE THE | | | MAKE AND MODEL NUMBER OF THE BOOTH ON THE SUPPRESSION | | | PLAN. | | | 2) THE FIRE SUPPRESSION PLAN HAS ILLEGIBLE PRINT EITHER | | | TOO SMALL OR FAINT TO READ AND SCAN FOR PUBLIC RECORD. | | | PROVIDE ENLARGED LEGIBLE PLANS IN ACCORDANCE WITH | | | SECTION 107.2.1.4 QUALITY OF BUILDING PLANS. BUILDING | | | PLANS SHALL BE DRAWN TO A MINIMUM 1/8 INCH | | | SCALE UPON SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE | | | MEDIUM. THE BUILDING OFFICIAL MAY ESTABLISH | | | THROUGH DEPARTMENTAL POLICY, OTHER STANDARDS FOR PLANS | | | AND SPECIFICATIONS, IN ORDER TO PROVIDE | | | CONFORMITY TO ITS RECORD RETENTION PROGRAM. THIS POLICY | | | MAY INCLUDE SUCH THINGS AS MINIMUM SIZE, | | | SHAPE, CONTRAST, CLARITY, OR OTHER ITEMS RELATED TO | | | RECORDS MANAGEMENT. ELECTRONIC MEDIA MUST BE | | | COMPATIBLE WITH THE ARCHIVE REQUIREMENTS OF FLORIDA | | | STATUTES. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2015-11-13 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-11-13 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-11-13 |
Time |
10:08 |
Sent To |
|
|
| Notes |
| 2015-11-13 11:38:32 | 1ST REVIEW: FBC 2014 MECHANICAL | | | PERMIT #15101055 | | | 11/13/15 | | | | | | 1) THERE IS A DISCREPANCY IN THE PLANS AND | | | SPECIFICATIONS FOR THE CHINOOK II PAINT SPRAY BOOTH: | | | TWO DIFFERENT MODEL NUMBERS ARE LISTED ON SHEET A- | | | (#42106X IN THE DRAWING, AND #99830X IN THE NOTES). SEE | | | PAGE 3 OF THE SUBMITTED BOOTH SPECS- MODEL #42106X AS | | | SPECIFIED ON THE PLANS DOES NOT COME WITH A HEATER, | | | HOWEVER AN 840,000 BTUH GAS FIRED BURNER IS LISTED IN | | | THE NOTES ON SHEET A AND ON SHEET M-1. PLEASE CLARIFY | | | WHICH BOOTH IS TO BE INSTALLED AND IF A GAS-FIRED | | | HEATER IS INCLUDED. IN ACCORDANCE WITH THE BOOTH SPECS, | | | EXPLOSION VENTING IS REQUIRED IF HEATING IS PROVIDED | | | (PAGES 3, 8, & 16), AND IN NOTE #14 ON SHEET | | | UNOBSTRUCTED EXPLOSION RELIEF IS REQUIRED. PLEASE | | | PROVIDE DETAILS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|