Plan Review Details - Permit 15100991
| Plan Review Stops For Permit 15100991 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2016-10-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-10-13 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-10-13 |
Time |
10:22 |
Sent To |
|
|
| Notes |
| 2016-10-13 14:15:17 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 15100991/ WAWA CONVENIENCE STORE | | | ADD: 1520 BELVEDERE RD. | | | CONT: ICONSTRUCTORS, LLC | | | TEL: 813-287-9000 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 4TH REVIEW | | | DATE: THURS. OCT. 13/ 2016 | | | ACTION: BUILDING PROVISO | | | | | | 1) PROVISO: ART IN PUBLIC PLACES. THE CITY OF WEST PALM | | | BEACH ART IN PUBLIC PLACES ORDINANCE REQUIREMENT THAT | | | APPLIES TO ANY REMODEL OR NEW CONSTRUCTION PROJECT FOR | | | WHICH THE PERMIT APPLICATION WAS SUBMITTED AFTER | | | 7/1/14, AND THE TOTAL PROJECT CONSTRUCTION COSTS ARE | | | EQUAL TO OR GREATER THAN $500,000. PER CITY OF WEST | | | PALM BEACH ORDINANCE NO. 4504-14, AND CITY OF WEST PALM | | | BEACH CODE OF ORDINANCES, ARTICLE V, ART IN PUBLIC | | | PLACES, SECTION 78-123(A) AND SECTION 78-126(A), THE | | | ART ASSESSMENT IS 1% OF THE TOTAL PROJECT CONSTRUCTION | | | COST. | | | 2) COMPLIED. THE FRONT COVER SHEET LIST 6 PRODUCT | | | APPROVALS SUBMITTED: | | | 2.1) ATAS DUTCH METAL ROOFING FL 3556R-5 | | | 2.2) KAWNEER WINDOW NOA 14-02130.18 | | | 2.3) KAWNEER DOOR NOA 14-0602.02 | | | 2.4) JAMES HARDI NOA 15-0122.03 | | | 2.5) BORAL STONE FL 1504.7 / 100378.05 R-3 | | | 2.6) BASF PERMALATH 1000 GLASS FIBER LATH ERS-2429 | | | | | | 3) BUILDING PROVISO: DEFERRED SUBMITTALS. 2014 FLORIDA | | | BUILDING CODE W 2014 WEST PALM BEACH AMENDMENTS TO THE | | | FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATION | | | 107.3.4.2 DEFERRED SUBMITTALS.2014 FBC-B 1609.1.2 | | | PROTECTION OF OPENINGS, 1609.6.4.4.1 COMPONENTS & | | | CLADDING. FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE | | | 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR | | | CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT | | | APPROVALS: | | | (31)(A) EXTERIOR DOORS. METAL EXTERIOR DOORS | | | (D) ROOFING PRODUCTS AND ASSEMBLIES,R-40 ROOF TOP | | | INSULATION, ASSEMBLIES FOR FLAT ROOF, ROOF TOP | | | EXHAUST FANS | | | (E) SHUTTERS- BAHAMA SHUTTERS | | | (G) PRE-ENGINEERED ROOF TOP A/C STANDS | | | (H) ROOF TOP LADDER( SHOP DRAWINGS) | | | | | | 4)PROVISO: 107.3.4.1 THOSE PRODUCTS WHICH ARE REGULATED | | | BY DCA RULE 9N-3SHALL BE REVIEWED AND APPROVED IN | | | WRITING BY THE DESIGNER OF RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION | | | DEVELOPMENT SERVICES DEPARTMENT | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2016-08-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-08-26 |
Time |
17:11 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-08-26 |
Time |
14:31 |
Sent To |
|
|
| Notes |
| 2016-08-26 17:01:01 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 15100991 WAWA CONVENIENCE STORE | | | ADD: 1520 BELVEDERE RD. | | | CONT: TBD( TO BE DETERMINED) NOT REGISTERED | | | TEL: 407-661-9100 X2462 | | | E-MAIL: [email protected] | | | | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 4TH REVIEW | | | DATE: FRI. AUGUST 26/2016 | | | ACTION: DENIED | | | | | | IMPORTANT!!!!!! PLEASE NOTE THIS LAST SUBMITTAL THE | | | PERMIT RUNNER DID NOT LET THE PERMIT TECH KNOW THERE | | | WERE PERMIT APPLICATIONS FROM THE CONTRACTOR IN THE | | | PACKAGE. WE CAN NOT PROCESS THE APPLICATIONS SINCE | | | THERE WERE NONE OF THE REQUIRED DOCUMENTS TO REGISTER | | | THE CONTRACTOR, THE REQUIRED DOCUMENTS ARE: | | | A) A CURRENT STATE LICENSE FOR THE QUALIFIER | | | B) A CURRENT BUSINESS TAX LICENSE/ OCCUPATIONAL LICENSE | | | FOR THEIR OFFICE | | | C) CURRENT GENERAL LIABILITY | | | D) CURRENT WORKERS COMP | | | | | | GENERAL LIBILITY & CORKERS COMP CERTIFICATE TO BE MADE | | | OUT TO THE: | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS ST | | | WEST PALM BEACH, F 33401L | | | | | | | | | | | | 1) PROVISO: ART IN PUBLIC PLACES. THE CITY OF WEST PALM | | | BEACH ART IN PUBLIC PLACES ORDINANCE REQUIREMENT THAT | | | APPLIES TO ANY REMODEL OR NEW CONSTRUCTION PROJECT FOR | | | WHICH THE PERMIT APPLICATION WAS SUBMITTED AFTER | | | 7/1/14, AND THE TOTAL PROJECT CONSTRUCTION COSTS ARE | | | EQUAL TO OR GREATER THAN $500,000. PER CITY OF WEST | | | PALM BEACH ORDINANCE NO. 4504-14, AND CITY OF WEST PALM | | | BEACH CODE OF ORDINANCES, ARTICLE V, ART IN PUBLIC | | | PLACES, SECTION 78-123(A) AND SECTION 78-126(A), THE | | | ART ASSESSMENT IS 1% OF THE TOTAL PROJECT CONSTRUCTION | | | COST. | | | | | | PER CITY OF WEST PALM BEACH CODE OF ORDINANCES, ARTICLE | | | V, ART IN PUBLIC PLACES, SECTION 78-122, RENOVATION AND | | | NEW CONSTRUCTION PROJECTS ARE ASSESSED CUMULATIVELY, SO | | | THE ART ASSESSMENT WILL BE APPLICABLE TO ALL FUTURE | | | PROJECTS | | | | | | 2) 4TH REQUEST. IMPORTANT!!!!!!!!!! NOTE 3 SET OF PAPER | | | PLANS ARE REQUIRED. NOTE ONLY 2 SETS OF PLAN ARE | | | SUBMITTED. ALL OTHER DOCUMENTS HAVE 3 SETS. | | | | | | | | | 6) COMPLIED. THE FRONT COVER SHEET LIST 6 PRODUCT | | | APPROVALS SUBMITTED: | | | 1) ATAS DUTCH METAL ROOFING FL 3556R-5 | | | 2) KAWNEER WINDOW NOA 14-02130.18 | | | 3) KAWNEER DOOR NOA 14-0602.02 | | | 4) JAMES HARDI NOA 15-0122.03 | | | 5) BORAL STONE FL 1504.7 / 100378.05 R-3 | | | 6) BASF PERMALATH 1000 GLASS FIBER LATH ERS-2429 | | | | | | 7A) BUILDING PROVISO: DEFERRED SUBMITTALS. 2014 FLORIDA | | | BUILDING CODE W 2014 WEST PALM BEACH AMENDMENTS TO THE | | | FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATION | | | 107.3.4.2 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS | | | SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE | | | PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE | | | TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO | | | THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. | | | DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR | | | APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED | | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST | | | THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS | | | FOR REVIEW BY THE BUILDING OFFICIAL. | | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | | OFFICIAL. | | | 2014 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT | | | OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) | | | SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT | | | WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS. METAL EXTERIOR DOORS | | | (D) ROOFING PRODUCTS AND ASSEMBLIES,R-40 ROOF TOP | | | INSULATION, ASSEMBLIES FOR FLAT ROOF, ROOF TOP | | | EXHAUST FANS | | | (E) SHUTTERS- BAHAMA SHUTTERS | | | (G) PRE-ENGINEERED ROOF TOP A/C STANDS | | | (H) ROOF TOP LADDER( SHOP DRAWINGS) | | | | | | 11) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2016-05-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-05-14 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-05-14 |
Time |
13:31 |
Sent To |
|
|
| Notes |
| 2016-05-14 15:00:35 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 15100991 WAWA CONVENIENCE STORE | | | ADD: 1520 BELVEDERE RD. | | | CONT: TBD( TO BE DETERMINED) | | | TEL: 407-661-9100 X2462 | | | E-MAIL: [email protected] | | | | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 3RD REVIEW | | | DATE: SAT. MAY 15/2016 | | | ACTION: DENIED | | | | | | 1) PROVISO: ART IN PUBLIC PLACES. THE CITY OF WEST PALM | | | BEACH ART IN PUBLIC PLACES ORDINANCE REQUIREMENT THAT | | | APPLIES TO ANY REMODEL OR NEW CONSTRUCTION PROJECT FOR | | | WHICH THE PERMIT APPLICATION WAS SUBMITTED AFTER | | | 7/1/14, AND THE TOTAL PROJECT CONSTRUCTION COSTS ARE | | | EQUAL TO OR GREATER THAN $500,000. PER CITY OF WEST | | | PALM BEACH ORDINANCE NO. 4504-14, AND CITY OF WEST PALM | | | BEACH CODE OF ORDINANCES, ARTICLE V, ART IN PUBLIC | | | PLACES, SECTION 78-123(A) AND SECTION 78-126(A), THE | | | ART ASSESSMENT IS 1% OF THE TOTAL PROJECT CONSTRUCTION | | | COST. | | | | | | PER CITY OF WEST PALM BEACH CODE OF ORDINANCES, ARTICLE | | | V, ART IN PUBLIC PLACES, SECTION 78-122, RENOVATION AND | | | NEW CONSTRUCTION PROJECTS ARE ASSESSED CUMULATIVELY, SO | | | THE ART ASSESSMENT WILL BE APPLICABLE TO ALL FUTURE | | | PROJECTS | | | | | | 2) COMPLIED. SITE PLAN SUBMITTED. | | | | | | 3) SEMI-COMPLIED. SUBMITTED SOILS REPORT FOR A | | | QUESTIONABLE SOIL ZONE . | | | SEE COMMENTS FROM 2ND REVIEW ON VARYING DEPTHS OF | | | SUSPECTED BURIED DEBRIS. | | | | | | 3A) 3RD. THE STRUCTURAL ENGINEER OF RECORD PLEASE | | | RESPOND WHAT STEPS ARE GOING TO BE UNDERTAKEN TO MAKE | | | THIS SITE A FOR A STABLE FOUNDATION AND BUILDABLE FOR | | | THIS TYPE OF STRUCTURE. | | | THE RESPONSE LETTER COMES FROM MOLLI LINDSEY NOT THE | | | STRUCTURAL ENGINEER OF RECORD. PLEASE ALLOW THE | | | STRUCTURAL ENGINEER TO WRITE THEIR OWN RESPONSE. | | | | | | 3B) THE PERMITTING COORDINATOR INDICATES THIS IS NOT IN | | | THE SCOPE OF THEIR WORK. PLEASE NOTE THE AMOUNT OF | | | DEBRIS TO BE REMOVED AND THE FILL TO BE BROUGHT BACK IN | | | WILL ALSO BE REVIEWED BY THE ENGINEER OF RECORD SINCE | | | THERE IS A CLOSENESS OF THE TANKS TO THE CANOPY | | | FOUNDATION, IF SHEET PILING ARE GOING TO BE USED AS | | | WELL AS IN WHAT ORDER OF WORK WILL THE UNDERGROUND | | | TANKS BE INSTALLED 1ST. | | | | | | | | | COMMENT FROM 1ST REVIEW. 2014 FLORIDA BUILDING CODE W | | | 2014 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | | CODE, CHAPTER 1, ADMINISTRATION. 107.3.5.1.1 MINIMUM | | | PLAN REVIEW CRITERIA FOR COMMERCIAL BUILDINGS. (8.) | | | STRUCTURAL REQUIREMENTS SHALL INCLUDE: SOIL | | | CONDITIONS/ANALYSIS | | | 2014 FBC-B 1803.5.2 QUESTIONABLE SOIL. WHERE THE | | | CLASSIFICATION, STRENGTH OR COMPRESSIBILITY OF THE SOIL | | | IS IN DOUBT OR WHERE A LOAD-BEARING VALUE SUPERIOR TO | | | THAT SPECIFIED IN THIS CODE IS CLAIMED, THE BUILDING | | | OFFICIAL SHALL BE PERMITTED TO REQUIRE THAT A | | | GEOTECHNICAL INVESTIGATION BE CONDUCTED. | | | | | | 4) THIS PROJECT WILL REQUIRE A RESIDENT INSPECTOR. 2010 | | | WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | | CODE, CHAPTER 1, ADMINISTRATION, 110.3.9 OTHER | | | INSPECTIONS SERVICES. THE BUILDING OFFICIAL MAY MAKE, | | | OR CAUSE TO BE MADE BY OTHERS, THE INSPECTIONS REQUIRED | | | BY SECTION 109. HE/SHE MAY ACCEPT REPORTS OF INSPECTORS | | | OF RECOGNIZED INSPECTION SERVICES, PROVIDED THAT AFTER | | | INVESTIGATION HE/SHE IS SATISFIED AS TO THEIR | | | QUALIFICATIONS AND RELIABILITY. A CERTIFICATE CALLED | | | FOR BY ANY PROVISION OF THE TECHNICAL CODES SHALL NOT | | | BE BASED ON SUCH REPORTS UNLESS THE SAME ARE IN WRITING | | | AND CERTIFIED BY A RESPONSIBLE OFFICER OF SUCH SERVICE. | | | THE BUILDING OFFICIAL MAY REQUIRE THE OWNER TO EMPLOY | | | AN INSPECTION SERVICE IN THE FOLLOWING INSTANCES: 7.) | | | FOR BUILDINGS AND STRUCTURES OF UNUSUAL DESIGN OR | | | METHODS OF CONSTRUCTION STEEL STRUCTURE WHERE EITHER | | | STEEL IS WELDED OR BOLTED TOGETHER. | | | | | | 4A) 3RD REQUEST. RESIDENT INSPECTOR FORMS MUST BE | | | SIGNED BY ALL PARTIES NOTARIZED AND RETURNED TO THE | | | BUILDING DEPARTMENT. FORMS WERE SENT TO: | | | 1) [email protected] MON. NOV. 23/2015 @ 08:14 AM. | | | 2) MOLLIL@C-P,COM SUN. FEB. 21/ 2016 @ 07:54 AM. | | | | | | 4B) 3RD REQUEST. FOR THE RESIDENT INSPECTOR PLEASE | | | PROVIDE A RESUME' OF INSPECTION EXPERIENCE ON PREVIOUS | | | PROJECT. THE RESUME' MUST BE ACCOMPANIED BY ALL | | | CERTIFICATES AS SPECIFIED HEREIN. THE BUILDING OFFICIAL | | | OR HIS DESIGNEE WILL REVIEW THE RESUME'. AFTER THE | | | RESUME' IS REVIEWED, AN INTERVIEW WILL BE SCHEDULED. | | | UNDER NO CIRCUMSTANCES WILL AN INSPECTOR BE INTERVIEWED | | | FOR WORK WITHOUT FIRST MEETING THE ABOVE CRITERIA. | | | | | | 4C) 3RD REQUEST. THE CONTRACTOR WILL PRODUCE A JOB | | | SUMMARY OR HISTORY FOR THIS TYPE OF CONSTRUCTION. | | | | | | 4D) 3RD REQUEST. NOTE FOR PAPER PLANS 3 SETS OF | | | DOCUMENTS ARE REQUIRED. NOTE ONLY 2 SETS OF SOILS | | | REPORTS, PRODUCT APPROVALS, LENNOX ROOF TOP CLIP | | | CALCULATIONS AND ENERGY CALCULATIONS SUBMITTED. | | | | | | 4E) INFORMATIONAL. PLEASE CALL THE CITY OF WEST PALM | | | BEACHS AUTOMATED TELEPHONE INSPECTIONS LINE (561) | | | 805-6700) FOR IN-PROGRESS INSPECTIONS FOR AUDITING OF | | | JOBSITE INSPECTIONS. | | | | | | 5) COMPLIED. SUBMITTAL: ROOF CURB CLIP CALCULATIONS BY | | | THOMAS RETSECK P. E. FL. # 46462 | | | | | | 6) COMPLIED. THE FRONT COVER SHEET LIST 6 PRODUCT | | | APPROVALS SUBMITTED: | | | 1) ATAS DUTCH METAL ROOFING FL 3556R-5 | | | 2) KAWNEER WINDOW NOA 14-02130.18 | | | 3) KAWNEER DOOR NOA 14-0602.02 | | | 4) JAMES HARDI NOA 15-0122.03 | | | 5) BORAL STONE FL 1504.7 / 100378.05 R-3 | | | 6) BASF PERMALATH 1000 GLASS FIBER LATH ERS-2429 | | | | | | 7A) BUILDING PROVISO: DEFERRED SUBMITTALS. 2014 FLORIDA | | | BUILDING CODE W 2014 WEST PALM BEACH AMENDMENTS TO THE | | | FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATION | | | 107.3.4.2 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS | | | SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE | | | PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE | | | TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO | | | THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. | | | DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR | | | APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED | | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST | | | THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS | | | FOR REVIEW BY THE BUILDING OFFICIAL. | | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | | OFFICIAL. | | | | | | | | | | | | 2014 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT | | | OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) | | | SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT | | | WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS. METAL EXTERIOR DOORS | | | (D) ROOFING PRODUCTS AND ASSEMBLIES,R-40 ROOF TOP | | | INSULATION, ASSEMBLIES FOR FLAT ROOF, ROOF TOP | | | EXHAUST FANS | | | (E) SHUTTERS- BAHAMA SHUTTERS | | | (G) PRE-ENGINEERED ROOF TOP A/C STANDS | | | (H) ROOF TOP LADDER( SHOP DRAWINGS) | | | | | | 7B)PROVISO: 107.3.4.1 THOSE PRODUCTS WHICH ARE | | | REGULATED BY DCA RULE 9N-3SHALL BE REVIEWED AND | | | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO | | | SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | | | 8-9) COMPLIED | | | | | | 10) NEW COMMENT BASED ON THE RESPONSE. PLEASE PROVIDE A | | | COPY OF THE TEST REPORT WALK IN FREEZER PANELS | | | CLASSIFIED IN ACCORDANCE WITH UL 1715 TO DOCUMENT NO | | | FIRE SPRINKLERS REQUIRED. THANK YOU. | | | COMMENT FROM 2ND REVIEW. THE FLOOR PLAN SHEET A1 SHOWS | | | THIS A BUILDING TYPE VB NON-SPRINKLERED BUILDING. SHOWS | | | VARIOUS WALK IN COOLERS AND FREEZERS. PLEASE NOTE THEY | | | WILL REQUIRE A SEPARATE PERMIT. THE ISSUE IS THIS IS A | | | NON-SPRINKLERED BUILDING. PLEASE REVIEW THE 2014 FBC-B | | | 2603.4.1.2 (4)COOLERS AND FREEZER WALLS. | | | 4. BE PROTECTED BY AN AUTOMATIC SPRINKLER SYSTEM IN | | | ACCORDANCE WITH SECTION 903.3.1.1. WHERE THE COOLER OR | | | FREEZER IS WITHIN A BUILDING, BOTH THE COOLER OR | | | FREEZER AND THAT PART OF THE BUILDING IN WHICH IT IS | | | LOCATED SHALL BE SPRINKLERED. | | | | | | THE EXCEPTION TO THIS IS FOUND UNDER SECTION 2603.4.1.3 | | | WALK-IN COOLERS. IN NON-SPRINKLERED BUILDINGS, FOAM | | | PLASTIC HAVING A THICKNESS THAT DOES NOT EXCEED 4 | | | INCHES (102 MM) AND A MAXIMUM FLAME SPREAD INDEX OF 75 | | | IS PERMITTED IN WALK-IN COOLERS OR FREEZER UNITS WHERE | | | THE AGGREGATE FLOOR AREA DOES NOT EXCEED 400 SQUARE | | | FEET (37 M2) AND THE FOAM PLASTIC IS COVERED BY A METAL | | | FACING NOT LESS THAN 0.032-INCH-THICK (0.81 MM) | | | ALUMINUM OR CORROSION-RESISTANT STEEL HAVING A MINIMUM | | | BASE METAL THICKNESS OF 0.016 INCH (0.41 MM). A | | | THICKNESS OF UP TO 10 INCHES (254 MM) IS PERMITTED | | | WHERE PROTECTED BY A THERMAL BARRIER. | | | | | | 11) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 12) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES | | | AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2016-02-21 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-02-21 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-02-19 |
Time |
11:59 |
Sent To |
|
|
| Notes |
| 2016-02-21 09:45:06 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 15100991 WAWA CONVENIENCE STORE | | | ADD: 1520 BELVEDERE RD. | | | CONT: TBD( TO BE DETERMINED) | | | TEL: 407-661-9100 X2462 | | | E-MAIL: [email protected] | | | | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: SUNS. FEB. 21/2015 | | | ACTION: DENIED | | | | | | 1) PROVISO: ART IN PUBLIC PLACES. THE CITY OF WEST PALM | | | BEACH ART IN PUBLIC PLACES ORDINANCE REQUIREMENT THAT | | | APPLIES TO ANY REMODEL OR NEW CONSTRUCTION PROJECT FOR | | | WHICH THE PERMIT APPLICATION WAS SUBMITTED AFTER | | | 7/1/14, AND THE TOTAL PROJECT CONSTRUCTION COSTS ARE | | | EQUAL TO OR GREATER THAN $500,000. PER CITY OF WEST | | | PALM BEACH ORDINANCE NO. 4504-14, AND CITY OF WEST PALM | | | BEACH CODE OF ORDINANCES, ARTICLE V, ART IN PUBLIC | | | PLACES, SECTION 78-123(A) AND SECTION 78-126(A), THE | | | ART ASSESSMENT IS 1% OF THE TOTAL PROJECT CONSTRUCTION | | | COST. | | | | | | PER CITY OF WEST PALM BEACH CODE OF ORDINANCES, ARTICLE | | | V, ART IN PUBLIC PLACES, SECTION 78-122, RENOVATION AND | | | NEW CONSTRUCTION PROJECTS ARE ASSESSED CUMULATIVELY, SO | | | THE ART ASSESSMENT WILL BE APPLICABLE TO ALL FUTURE | | | PROJECTS | | | | | | 2) COMPLIED. SITE PLAN SUBMITTED | | | | | | 3) SEMI-COMPLIED. SUBMITTED SOILS REPORT FOR A | | | QUESTIONABLE SOIL ZONE . | | | | | | THE STRUCTURAL ENGINEER OF RECORD IT APPEARS HAS NOT | | | SEEN THE SOILS REPORT WHICH REFERENCES THERE BEING A | | | WASTE LANDFILL THICKNESS VARYING UP TO 23 FEET THICK | | | WITH AN AVERAGE THICKNESS OF 10 FEET IN THICKNESS. THE | | | STRUCTURAL SHEET S1 NOTE A INDICATES NO SOILS REPORT | | | PROVIDED. PAGE 3 OF THE REPORT INDICATES USING A ERI | | | TRANSECT FIGURE -1 SHOWS THE ESTIMATED THICKNESS OF THE | | | SUSPECTED BURIED DEBRIS ON THE ERI TRANSECTS IN PLAN | | | VIEW IN 5 FT. INCREMENTS FROM PURPLE (THINNEST AT 0 | | | FEET BLS) TO RED (THICKEST AT OVER 40 FEET BLS). | | | THE ERI TRANSECT SCANS A1-A4 SHOW THAT THE A-1 SCAN HAS | | | THE MOST SIGNIFICANT POTENTIAL FOR SETTLEMENT. | | | | | | THIS AREA IS ALSO IN A QUESTIONABLE SOILS ZONE SINCE | | | THERE HAS BEEN MUCK FOUND ALONG THE CANAL JUST EAST OF | | | THE SITE. THE SOILS TESTING BORING LOGS SHOW THE | | | BORINGS HAVE ONLY WENT DOWN TEN FEET. | | | | | | THE SOILS REPORT ALSO INDICATES THE LOT ELEVATION IS | | | APPROXIMATELY 15 TO 20 FEET ABOVE THE STREET GRADE | | | ELEVATION AND THIS LAYER OF SOILS WOULD NEED TO BE | | | REMOVED FROM THE SITE TO OBTAIN A WORKING GRADE FOR THE | | | SITE. DEPENDING ON THE TYPE OF SOILS STABELIZATION A | | | SOILS ENGINEER MAY BE REQUIRED ON SITE ONCE THE TYPE OF | | | SOILS STABELIZATION IS KNOWN. | | | | | | 3A) THE STRUCTURAL ENGINEER OF RECORD PLEASE RESPOND | | | WHAT STEPS ARE GOING TO BE UNDERTAKEN TO MAKE THIS SITE | | | A FOR A STABLE FOUNDATION AND BUILDABLE FOR THIS TYPE | | | OF STRUCTURE. | | | | | | 3B) PLEASE ALSO PROVIDE DETAILED INFORMATION WHAT STEPS | | | WILL ALSO NEED TO STABILIZE THE SOILS AND TO SECURE THE | | | UNDERGROUND FUEL TANKS AND KEEP THEM SAFE FROM MOVEMENT | | | AND SETTLEMENT, ONCE THE TANKS ARE FULL. WILL A | | | DEWATERING PLAN BE SUBMITTED FOR THE INSTALATION OF THE | | | UNDERGROUND FUEL TANKS? | | | | | | COMMENT FROM 1ST REVIEW. 2014 FLORIDA BUILDING CODE W | | | 2014 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | | CODE, CHAPTER 1, ADMINISTRATION. 107.3.5.1.1 MINIMUM | | | PLAN REVIEW CRITERIA FOR COMMERCIAL BUILDINGS. | | | (8.) STRUCTURAL REQUIREMENTS SHALL INCLUDE: SOIL | | | CONDITIONS/ANALYSIS | | | 2014 FBC-B 1803.5.2 QUESTIONABLE SOIL. WHERE THE | | | CLASSIFICATION, STRENGTH OR COMPRESSIBILITY OF THE SOIL | | | IS IN DOUBT OR WHERE A LOAD-BEARING VALUE SUPERIOR TO | | | THAT SPECIFIED IN THIS CODE IS CLAIMED, THE BUILDING | | | OFFICIAL SHALL BE PERMITTED TO REQUIRE THAT A | | | GEOTECHNICAL INVESTIGATION BE CONDUCTED. | | | | | | 4) THIS PROJECT WILL REQUIRE A RESIDENT INSPECTOR. 2010 | | | WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | | CODE, CHAPTER 1, ADMINISTRATION, 110.3.9 OTHER | | | INSPECTIONS SERVICES. THE BUILDING OFFICIAL MAY MAKE, | | | OR CAUSE TO BE MADE BY OTHERS, THE INSPECTIONS REQUIRED | | | BY SECTION 109. HE/SHE MAY ACCEPT REPORTS OF INSPECTORS | | | OF RECOGNIZED INSPECTION SERVICES, PROVIDED THAT AFTER | | | INVESTIGATION HE/SHE IS SATISFIED AS TO THEIR | | | QUALIFICATIONS AND RELIABILITY. A CERTIFICATE CALLED | | | FOR BY ANY PROVISION OF THE TECHNICAL CODES SHALL NOT | | | BE BASED ON SUCH REPORTS UNLESS THE SAME ARE IN WRITING | | | AND CERTIFIED BY A RESPONSIBLE OFFICER OF SUCH SERVICE. | | | THE BUILDING OFFICIAL MAY REQUIRE THE OWNER TO EMPLOY | | | AN INSPECTION SERVICE IN THE FOLLOWING INSTANCES: 7.) | | | FOR BUILDINGS AND STRUCTURES OF UNUSUAL DESIGN OR | | | METHODS OF CONSTRUCTION STEEL STRUCTURE WHERE EITHER | | | STEEL IS WELDED OR BOLTED TOGETHER. | | | | | | 4A) RESIDENT INSPECTOR FORMS MUST BE SIGNED BY ALL | | | PARTIES NOTARIZED AND RETURNED TO THE BUILDING | | | DEPARTMENT. FORMS WERE SENT TO: | | | 1) [email protected] MON. NOV. 23/2015 @ 08:14 AM. | | | 2) MOLLIL@C-P,COM SUN. FEB. 21/ 2016 @ 07:54 AM. | | | | | | 4B) FOR THE RESIDENT INSPECTOR PLEASE PROVIDE A RESUME' | | | OF INSPECTION EXPERIENCE ON PREVIOUS PROJECT. THE | | | RESUME' MUST BE ACCOMPANIED BY ALL CERTIFICATES AS | | | SPECIFIED HEREIN. THE BUILDING OFFICIAL OR HIS DESIGNEE | | | WILL REVIEW THE RESUME'. AFTER THE RESUME' IS REVIEWED, | | | AN INTERVIEW WILL BE SCHEDULED. UNDER NO CIRCUMSTANCES | | | WILL AN INSPECTOR BE INTERVIEWED FOR WORK WITHOUT FIRST | | | MEETING THE ABOVE CRITERIA. | | | | | | 4C) THE CONTRACTOR WILL PRODUCE A JOB SUMMARY OR | | | HISTORY FOR THIS TYPE OF CONSTRUCTION. | | | | | | 4D) NOTE FOR PAPER PLANS 3 SETS OF DOCUMENTS ARE | | | REQUIRED. FOR DIGITAL PLANS, AFTER PERMIT ISSUANCE, THE | | | PERMIT LIBRARIAN WILL E-MAIL YOU, THE APPROVED AND | | | BATCH STAMPED PLANS SO YOU MAY PRINT YOUR PLANS, TWO | | | SETS OF PLANS WILL NEED TO BE PRINTED IN COLOR, (1) FOR | | | THE RESIDENT INSPECTOR, THE OTHER FOR THE MEP | | | INSPECTORS. | | | | | | 4E) PLEASE CALL THE CITY OF WEST PALM BEACH?S AUTOMATED | | | TELEPHONE INSPECTIONS LINE (561) 805-6700) FOR | | | IN-PROGRESS INSPECTIONS FOR AUDITING OF JOBSITE | | | INSPECTIONS. | | | | | | 5) COMPLIED. SUBMITTAL: ROOF CURB CLIP CALCULATIONS BY | | | THOMAS RETSECK P. E. FL. # 46462 | | | | | | 6) COMPLIED. THE FRONT COVER SHEET LIST 6 PRODUCT | | | APPROVALS SUBMITTED: | | | 1) ATAS DUTCH METAL ROOFING FL 3556R-5 | | | 2) KAWNEER WINDOW NOA 14-02130.18 | | | 3) KAWNEER DOOR NOA 14-0602.02 | | | 4) JAMES HARDI NOA 15-0122.03 | | | 5) BORAL STONE FL 1504.7 / 100378.05 R-3 | | | 6) BASF PERMALATH 1000 GLASS FIBER LATH ERS-2429 | | | | | | | | | | | | | | | | | | 7A) BUILDING PROVISO: DEFERRED SUBMITTALS. 2014 FLORIDA | | | BUILDING CODE W 2014 WEST PALM BEACH AMENDMENTS TO THE | | | FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATION | | | 107.3.4.2 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS | | | SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE | | | PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE | | | TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO | | | THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. | | | DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR | | | APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED | | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST | | | THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS | | | FOR REVIEW BY THE BUILDING OFFICIAL. | | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | | OFFICIAL. | | | | | | | | | | | | 2014 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT | | | OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) | | | SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT | | | WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS. METAL EXTERIOR DOORS | | | (D) ROOFING PRODUCTS AND ASSEMBLIES,R-40 ROOF TOP | | | INSULATION, ASSEMBLIES FOR FLAT ROOF, ROOF TOP | | | EXHAUST FANS | | | (E) SHUTTERS- BAHAMA SHUTTERS | | | (G) PRE-ENGINEERED ROOF TOP A/C STANDS | | | (H) ROOF TOP LADDER( SHOP DRAWINGS) | | | | | | 7B)PROVISO: 107.3.4.1 THOSE PRODUCTS WHICH ARE | | | REGULATED BY DCA RULE 9N-3SHALL BE REVIEWED AND | | | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO | | | SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | | | 8-9) COMPLIED | | | | | | 10) THE FLOOR PLAN SHEET A1 SHOWS THIS A BUILDING TYPE | | | VB NON-SPRINKLERED BUILDING. SHOWS VARIOUS WALK IN | | | COOLERS AND FREEZERS. PLEASE NOTE THEY WILL REQUIRE A | | | SEPARATE PERMIT. THE ISSUE IS THIS IS A NON-SPRINKLERED | | | BUILDING. PLEASE REVIEW THE 2014 FBC-B 2603.4.1.2 | | | (4)COOLERS AND FREEZER WALLS. | | | 4. BE PROTECTED BY AN AUTOMATIC SPRINKLER SYSTEM IN | | | ACCORDANCE WITH SECTION 903.3.1.1. WHERE THE COOLER OR | | | FREEZER IS WITHIN A BUILDING, BOTH THE COOLER OR | | | FREEZER AND THAT PART OF THE BUILDING IN WHICH IT IS | | | LOCATED SHALL BE SPRINKLERED. | | | | | | THE EXCEPTION TO THIS IS FOUND UNDER SECTION 2603.4.1.3 | | | WALK-IN COOLERS. IN NONSPRINKLERED BUILDINGS, FOAM | | | PLASTIC HAVING A THICKNESS THAT DOES NOT EXCEED 4 | | | INCHES (102 MM) AND A MAXIMUM FLAME SPREAD INDEX OF 75 | | | IS PERMITTED IN WALK-IN COOLERS OR FREEZER UNITS WHERE | | | THE AGGREGATE FLOOR AREA DOES NOT EXCEED 400 SQUARE | | | FEET (37 M2) AND THE FOAM PLASTIC IS COVERED BY A METAL | | | FACING NOT LESS THAN 0.032-INCH-THICK (0.81 MM) | | | ALUMINUM OR CORROSION-RESISTANT STEEL HAVING A MINIMUM | | | BASE METAL THICKNESS OF 0.016 INCH (0.41 MM). A | | | THICKNESS OF UP TO 10 INCHES (254 MM) IS PERMITTED | | | WHERE PROTECTED BY A THERMAL BARRIER. | | | | | | 11) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 12) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES | | | AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-11-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-11-23 |
Time |
13:50 |
Rev Time |
|
| Received By |
jwitmer |
Date |
2015-11-23 |
Time |
06:45 |
Sent To |
|
|
| Notes |
| 2015-11-23 13:50:06 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 15100991 WAWA CONVENIENCE STORE | | | ADD: 1520 BELVEDERE RD. | | | CONT: TBD( TO BE DETERMINED) | | | TEL: 407-661-9100 X2462 | | | E-MAIL: [email protected] | | | | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: MON. NOV. 23/2015 | | | ACTION: DENIED | | | | | | 1) ART IN PUBLIC PLACES. THE CITY OF WEST PALM BEACH | | | ART IN PUBLIC PLACES ORDINANCE REQUIREMENT THAT APPLIES | | | TO ANY REMODEL OR NEW CONSTRUCTION PROJECT FOR WHICH | | | THE PERMIT APPLICATION WAS SUBMITTED AFTER 7/1/14, AND | | | THE TOTAL PROJECT CONSTRUCTION COSTS ARE EQUAL TO OR | | | GREATER THAN $500,000. PER CITY OF WEST PALM BEACH | | | ORDINANCE NO. 4504-14, AND CITY OF WEST PALM BEACH CODE | | | OF ORDINANCES, ARTICLE V, ART IN PUBLIC PLACES, SECTION | | | 78-123(A) AND SECTION 78-126(A), THE ART ASSESSMENT IS | | | 1% OF THE TOTAL PROJECT CONSTRUCTION COST. | | | | | | PER CITY OF WEST PALM BEACH CODE OF ORDINANCES, ARTICLE | | | V, ART IN PUBLIC PLACES, SECTION 78-122, RENOVATION AND | | | NEW CONSTRUCTION PROJECTS ARE ASSESSED CUMULATIVELY, SO | | | THE ART ASSESSMENT WILL BE APPLICABLE TO ALL FUTURE | | | PROJECTS | | | | | | 2) MISSING FROM PLANS SITE PLAN. 2014 FLORIDA BUILDING | | | CODE W 2014 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION. 107.2.5 SITE | | | PLAN. / 107.3.5.1.1 MINIMUM PLAN REVIEW CRITERIA FOR | | | COMMERCIAL BUILDINGS. | | | (1.) SITE REQUIREMENTS: | | | PARKING | | | FIRE ACCESS | | | VEHICLE LOADING | | | DRIVING/TURNING RADIUS | | | FIRE HYDRANT/WATER SUPPLY/POST INDICATOR VALVE (PIV) | | | SET BACK/SEPARATION (ASSUMED PROPERTY LINES) | | | LOCATION OF SPECIFIC TANKS, WATER LINES AND SEWER LINES | | | FLOOD HAZARD AREAS, FLOOD ZONES, AND DESIGN FLOOD | | | ELEVATIONS | | | | | | 3) MISSING FROM PLAN REVIEW SOILS REPORT THE AREA IS IN | | | A QUESTIONABLE SOIL ZONE . 2014 FLORIDA BUILDING CODE W | | | 2014 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | | CODE, CHAPTER 1, ADMINISTRATION. 107.3.5.1.1 MINIMUM | | | PLAN REVIEW CRITERIA FOR COMMERCIAL BUILDINGS. | | | (8.) STRUCTURAL REQUIREMENTS SHALL INCLUDE: SOIL | | | CONDITIONS/ANALYSIS | | | 2014 FBC-B 1803.5.2 QUESTIONABLE SOIL. WHERE THE | | | CLASSIFICATION, STRENGTH OR COMPRESSIBILITY OF THE SOIL | | | IS IN DOUBT OR WHERE A LOAD-BEARING VALUE SUPERIOR TO | | | THAT SPECIFIED IN THIS CODE IS CLAIMED, THE BUILDING | | | OFFICIAL SHALL BE PERMITTED TO REQUIRE THAT A | | | GEOTECHNICAL INVESTIGATION BE CONDUCTED. | | | | | | 4) THIS PROJECT WILL REQUIRE A RESIDENT INSPECTOR. 2010 | | | WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | | CODE, CHAPTER 1, ADMINISTRATION, 110.3.9 OTHER | | | INSPECTIONS SERVICES. THE BUILDING OFFICIAL MAY MAKE, | | | OR CAUSE TO BE MADE BY OTHERS, THE INSPECTIONS REQUIRED | | | BY SECTION 109. HE/SHE MAY ACCEPT REPORTS OF INSPECTORS | | | OF RECOGNIZED INSPECTION SERVICES, PROVIDED THAT AFTER | | | INVESTIGATION HE/SHE IS SATISFIED AS TO THEIR | | | QUALIFICATIONS AND RELIABILITY. A CERTIFICATE CALLED | | | FOR BY ANY PROVISION OF THE TECHNICAL CODES SHALL NOT | | | BE BASED ON SUCH REPORTS UNLESS THE SAME ARE IN WRITING | | | AND CERTIFIED BY A RESPONSIBLE OFFICER OF SUCH SERVICE. | | | THE BUILDING OFFICIAL MAY REQUIRE THE OWNER TO EMPLOY | | | AN INSPECTION SERVICE IN THE FOLLOWING INSTANCES: 7.) | | | FOR BUILDINGS AND STRUCTURES OF UNUSUAL DESIGN OR | | | METHODS OF CONSTRUCTION STEEL STRUCTURE WHERE EITHER | | | STEEL IS WELDED OR BOLTED TOGETHER. | | | | | | 4A) RESIDENT INSPECTOR FORMS MUST BE SIGNED BY ALL | | | PARTIES NOTARIZED AND RETURNED TO THE BUILDING | | | DEPARTMENT. FORMS WERE SENT TO: : [email protected] MON. | | | NOV. 23/2015 @ 08:14 AM. | | | | | | 4B) FOR THE RESIDENT INSPECTOR PLEASE PROVIDE A RESUME' | | | OF INSPECTION EXPERIENCE ON PREVIOUS PROJECT. THE | | | RESUME' MUST BE ACCOMPANIED BY ALL CERTIFICATES AS | | | SPECIFIED HEREIN. THE BUILDING OFFICIAL OR HIS DESIGNEE | | | WILL REVIEW THE RESUME'. AFTER THE RESUME' IS REVIEWED, | | | AN INTERVIEW WILL BE SCHEDULED. UNDER NO CIRCUMSTANCES | | | WILL AN INSPECTOR BE INTERVIEWED FOR WORK WITHOUT FIRST | | | MEETING THE ABOVE CRITERIA. | | | CONTACT: KEN CONRAD | | | TEL: 561-805-6666 | | | E-MAIL: [email protected] | | | | | | 4C) THE CONTRACTOR WILL PRODUCE A JOB SUMMARY OR | | | HISTORY FOR THIS TYPE OF CONSTRUCTION. THIS MAY BE | | | SUBMITTED TO KEN CONRAD BY E-MAIL. KEN CONRAD: | | | [email protected] | | | | | | 4D) NOTE FOR PAPER PLANS 3 SETS OF DOCUMENTS ARE | | | REQUIRED. FOR DIGITAL PLANS, AFTER PERMIT ISSUANCE, THE | | | PERMIT LIBRARIAN WILL E-MAIL YOU, THE APPROVED AND | | | BATCH STAMPED PLANS SO YOU MAY PRINT YOUR PLANS, TWO | | | SETS OF PLANS WILL NEED TO BE PRINTED IN COLOR, (1) FOR | | | THE RESIDENT INSPECTOR, THE OTHER FOR THE MEP | | | INSPECTORS. | | | | | | 4E) PLEASE CALL THE CITY OF WEST PALM BEACH?S AUTOMATED | | | TELEPHONE INSPECTIONS LINE (561) 805-6700) FOR | | | IN-PROGRESS INSPECTIONS FOR AUDITING OF JOBSITE | | | INSPECTIONS. | | | | | | 5) SUBMITTAL: ROOF CURB CLIP CALCULATIONS BY THOMAS | | | RETSECK P. E. FL. # 46462 | | | 5A) THE SUBMITTALS FOR ROOF CURB CLIP CALCULATIONS BY | | | THOMAS RETSECK P. E. FL. # 46462 ARE COPIES, NOT | | | ORIGINALLY SIGNED & SEALED. 61G15-23.002(2) FL. ADMIN. | | | CODE. | | | | | | 5B) THE SUBMITTALS FOR ROOF CURB CLIP CALCULATIONS BY | | | THOMAS RETSECK P. E. FL. # 46462 HAVE NUMBERED SHEETS | | | WITHIN THIS REPORT THAT APPEAR TO BE PULLED FROM MORE | | | THAN DOCUMENT. THE PAGE NUMBERS ARE FROM WHAT APPEARS | | | DIFFERENT DOCUMENTS. NOT ALL SHEETS ARE SIGNED NOR | | | SEALED NOR IS THERE AN INDEX ON THE COVER SHEET | | | INDICATING HOW MANY SHEETS ARE WITHIN THE SIGNED AND | | | SEALED DOCUMENT. THE INDEX SHEET IS NOT SIGNED NOR | | | SEALED. 61G15-23.002(2) FL. ADMIN. CODE. A COVER SHEET | | | OR INDEX SHEET. | | | | | | 5C) THE SUBMITTALS FOR ROOF CURB CLIP CALCULATIONS BY | | | THOMAS RETSECK P. E. FL. # 46462 INDICATES THIS DESIGN | | | WAS UNDER THE 2010 FBC-B . LABELED SHEET 2 INDICATES | | | CALCULATIONS PER THE 2010 FLORIDA BUILDING CODE AND | | | REFERENCES WIND FORCES PER 1609 VW= 170 MPH. UNDER THE | | | 2010 FBC-B WE WERE UNDER A 140 MPH WIND ZONE VASD, 3 | | | SECOND GUST. NOT THE 170 VULT AS THE CURRENT 2014 | | | FBC-B, PLEASE CORRECT CODE ANALYSIS AND CALCULATIONS. | | | | | | 6) THE FRONT COVER SHEET LIST 6 PRODUCT APPROVALS TO BE | | | INSTALLED AT THIS JOBSITE LOCATION. PLEASE NOTE TO | | | SUBMIT THE FLORIDA APPROVAL NUMBER WITH THE REPORTS. | | | THE DUTCH SEAM METAL ROOFING REPORT DOES NOT SHOW UP ON | | | THE FLORIDA PRODUCT APPROVAL WEBSITE. IF THERE IS NO | | | FLORIDA APPROVAL YOU WILL NEED TO SUBMIT FOR EITHER A | | | LOCAL APPROVAL OR FOR A SITE SPECIFIC APPROVAL. FLORIDA | | | APPROVALS DO NOT START WITH MRD. THEY HAVE A FL NUMBER. | | | | | | SECTION 1707 ALTERNATIVE TEST PROCEDURE | | | 1707.1 GENERAL. IN THE ABSENCE OF APPROVED RULES OR | | | OTHER APPROVED STANDARDS, THE BUILDING OFFICIAL SHALL | | | MAKE, OR CAUSE TO BE MADE, THE NECESSARY TESTS AND | | | INVESTIGATIONS; OR THE BUILDING OFFICIAL SHALL ACCEPT | | | DULY AUTHENTICATED REPORTS FROM APPROVED AGENCIES IN | | | RESPECT TO THE QUALITY AND MANNER OF USE OF NEW | | | MATERIALS OR ASSEMBLIES AS PROVIDED FOR IN SECTION | | | 104.11. THE COST OF ALL TESTS AND OTHER INVESTIGATIONS | | | REQUIRED UNDER THE PROVISIONS OF THIS CODE SHALL BE | | | BORNE BY THE APPLICANT. | | | | | | 7A) BELOW IS A LIST OF COMPONENTS AND CLADDING FOR | | | PRODUCT APPROVALS THAT CAN BE SUBMITTED NOW OR MAY BE | | | CONSIDERED A DEFERRED SUBMITTAL (107.3.4.2.) 2010 FBC-B | | | 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.4.1 | | | COMPONENTS & CLADDING. FLORIDA DEPARTMENT OF COMMUNITY | | | AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF | | | PRODUCTS OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE | | | PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS. | | | (B) WINDOWS | | | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL | | | LOUVERS, EFIS SYSTEMS, | | | (D) ROOFING PRODUCTS AND ASSEMBLIES,R-40 ROOF TOP | | | INSULATION, ASSEMBLIES FOR FLAT & SLOPED, ROOF TOP | | | CURBS, ROOF TOP INTAKE & EXHAUST FANS | | | (E) SHUTTERS | | | (F) SKYLIGHTS | | | (G) EXTERIOR COOLER, FREEZERS & PRE-ENGINEERED A/C | | | STANDS | | | | | | 7B) 107.3.4.1 THOSE PRODUCTS WHICH ARE REGULATED BY DCA | | | RULE 9N-3SHALL BE REVIEWED AND APPROVED IN WRITING BY | | | THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. | | | | | | 7C) PRODUCT APPROVALS DOORS, WINDOWS AND MULLIONS, | | | PLEASE CIRCLE TO IDENTIFY WIDTH, HEIGHT, OF GLAZING. | | | MULLIONS SIZE OF MULLION, LENGTH OF MULLION, IF | | | RE-ENFORCED OR NOT, CIRCLE THE ASSOCIATED PRESSURES | | | WITH THE TRIBUTARY AREA, AND THE FASTENERS TO BE | | | INSTALLED. | | | | | | 7D) NO FLAT ROOF PRODUCT APPROVAL, ROOF TOP CURBS, ROOF | | | TOP INTAKE & EXHAUST FANS NOR PRE-ENGINEERED A/C STANDS | | | WERE SUBMITTED. | | | | | | 8) SHEET S-1 THE NEGATIVE PRESSURES FOR OPENINGS IN | | | WALL ZONES 4 & 5 BOTH APPEAR TO BE A LITTLE LOW FOR | | | 130.1 VASD WITH A MEAN ROOF HEIGHT OF 17.83. 2014 FBC-B | | | 1603.1.4(5) WIND DESIGN DATA. | | | | | | 9) SHEET A3 SHOWS A ROOF TOP MASTER BUILT CONDENSING | | | UNIT DETAIL 6/ A3 SHOWS A CUT SECTION THROUGH THE | | | RAISED EQUIPMENT CURB. THE STRUCTURAL SHEET S-4.1 SHOWS | | | THE UNIT AND DETAILS 22 & 23 OF THE SAME S-4.1. | | | | | | 9A) DETAIL # 23 SHOWS (3) CONTINUOUS 2X6 PT PLATES | | | BEING ANCHORED TO THE B-DECK WITH # 10 TEK SCREWS @ 12 | | | INCHES ON CENTER MAXIMUM. 107.2.1.3 ADDITIONAL | | | INFORMATION IS REQUIRED. THE PLAN DOES NOT STATE THE | | | LENGTH OF THE TEK SCREWS? THE MAXIMUM OF 12 INCHES ON | | | CENTER, DOES THIS MEAN 3 SCREWS ARE PUT IN EVERY 12 | | | INCHES ON CENTER? THE PLANS DO NOT CLEARLY INDICATE | | | DOES THE TEK SCREWS ONLY GO THROUGH THE B DECK OR ARE | | | THEY REQUIRED TO PENETRATE THE STEEL ANGLE THAT IS PART | | | OF THE MWFRS (MAIN WIND FORCE RESISTING SYSTEM). | | | 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 9B) SAME DETAIL, THE (3) HORIZONTAL 2X6 PT BOTTOM PLATE | | | SHOWS (3) 2X12 VERTICAL PT MEMBERS BEING ATTACHED TO | | | THE TOP 2X6 PT MEMBER WITH # 10 WOOD SCREWS 12 INCHES | | | ON CENTER. AGAIN THERE IS NO LENGTH OF THE SCREW? ). | | | 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 9C) SAME DETAIL SHOWS A ? INCH PLYWOOD WOOD DECK | | | ATTACHED WITH # 10 WOOD SCREWS MAXIMUM 12 INCHES ON | | | CENTER. AGAIN THERE IS NO DIMENSION AS TO LENGTH. THERE | | | ARE NO STRAPS TYING THE BOTTOM PLATE TO THE TOP. THERE | | | IS ALSO NO DETAIL OF HOW THE MASTER BUILT CONDENSING | | | UNIT WILL BE ANCHORED TO THE RAISED CURB. 2014 FBC- M- | | | 301.15 WIND RESISTANCE. MECHANICAL EQUIPMENT, | | | APPLIANCES AND SUPPORTS THAT ARE EXPOSED TO WIND SHALL | | | BE DESIGNED AND INSTALLED TO RESIST THE WIND PRESSURES | | | DETERMINED IN ACCORDANCE WITH THE FLORIDA BUILDING | | | CODE, BUILDING. | | | | | | 10) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | | | | 11) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES | | | AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A | | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | | THIS REVIEW. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2016-02-26 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2016-02-26 |
Time |
12:30 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2016-02-26 |
Time |
10:29 |
Sent To |
|
|
| Notes |
| 2016-02-26 12:34:05 | ALL PREVIOUSLY MENTIONED DEFICIENCIES HAVE BEEN | | | SATISFACTORILY ADDRESSED. AT FIRST I HAD QUESTIONS | | | ABOUT THE FIRST COMMENT DEALING WITH LIGHTING CONTROL | | | FOR THE ILLUMINATION WITHIN THE TRASH COMPOUND, BUT | | | AFTER DISCUSSING THE MATTER WITH THE DESIGN | | | PROFESSIONAL, THEIR INTENT IS FOR THE AREA TO REMAIN | | | LIT WHILE THE STORE IS OPEN DURING THE NIGHT TIME FOR | | | SECURITY PURPOSES. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2015-12-29 |
|
|
Cont ID |
|
| Sent By |
malbarra |
Date |
2015-12-29 |
Time |
15:02 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-12-29 |
Time |
09:08 |
Sent To |
POLICE |
|
| Notes |
| 2015-12-29 15:06:38 | THE PLANS FOR THE ABOVE MENTIONED PERMIT APPLICATION | | | HAVE BEEN REVIEWED FOR COMPLIANCE WITH THE EDITION OF | | | THE NEC, (NATIONAL ELECTRICAL CODE) AND THE FBC, | | | (FLORIDA BUILDING CODE) AS WELL AS THE CITY OF WEST | | | PALM BEACH AMENDMENTS IN EFFECT AT THE TIME OF | | | SUBMITTAL. BELOW IS A LIST OF THE DEFICIENCIES NOTED. | | | 1. THERE DOES NOT APPEAR TO BE LIGHTING CONTROL FOR THE | | | TRASH COMPOUND LIGHTING. MANDATORY LIGHTING CONTROLS AS | | | REQUIRED BY FBC-E. | | | 2. ON SEVERAL OCCASIONS YOU REFER TO THE CIVIL DRAWING | | | FOR REFERENCE. I WAS UNABLE TO LOCATE THE REFERENCED | | | CIVIL DRAWING. YOU SHALL PROVIDE A SITE PLAN INDICATING | | | THE LOCATION OF THE TRASH COMPOUND AND CANOPY WITH | | | RELATION TO THE RETAIL BLDG. THIS WILL ALLOW FOR THE | | | PROPER PLACEMENT OF THE EMERGENCY SHUT OFF REQUIRED BY | | | NEC 514.11. | | | 3. THE GENERAL NOTES ON SHEET E1 REFER TO THE 2008 | | | EDITION OF THE NEC WHEN THE EDITION IN FORCE FOR THIS | | | PROJECT IS THE 2011. CORRECT THE NOTE ACCORDINGLY. | | | 4. NEC 600.5 REQUIRED BRANCH CIRCUIT. EACH COMMERCIAL | | | BUILDING AND EACH COMMERCIAL OCCUPANCY ACCESSIBLE TO | | | PEDESTRIANS SHALL BE PROVIDED WITH AT LEAST ONE 20 AMP | | | DEDICATED OUTLET IN AN ACCESSIBLE LOCATION AT EACH | | | ENTRANCE TO EACH TENANT SPACE FOR SIGN OR OUTLINE | | | LIGHTING. SERVICE HALLWAYS OR CORRIDORS SHALL NOT BE | | | CONSIDERED ACCESSIBLE TO PEDESTRIANS. REVISE YOUR PLANS | | | TO INCLUDE THE REQUIRED SIGN OUTLETS. | | | 5. NEC 210.62 SHOW WINDOWS. AT LEAST ONE RECEPTACLE | | | OUTLET SHALL BE INSTALLED WITHIN 18? OF THE TOP OF A | | | SHOW WINDOW FOR EVERY 12 LINEAR FT. OR MAJOR PORTION | | | THEREOF AREA MEASURED HORIZONTALLY. THOUGH YOU DO | | | INDICATE SHOW WINDOW OUTLETS, THE PLACEMENT AND | | | QUANTITIES DO NOT MEET THE MINIMUM CODE REQUIREMENTS. | | | 6. NEC 210.8(B) GROUND FAULT CIRCUIT-INTERRUPTER | | | PROTECTION REQUIRED FOR ALL ROOFTOP OUTLETS. THE | | | OUTLETS SHOWN DO NOT COMPLY, REVISE PLANS ACCORDINGLY. | | | 7. NEC 406.9(B) RECEPTACLES IN WET LOCATIONS. 15 AND 20 | | | AMPERE, 125 AND 250 VOLT RECEPTACLES INSTALLED IN A WET | | | LOCATION SHALL HAVE AN ENCLOSURE THAT IS WEATHERPROOF | | | WHETHER OR NOT THE ATTACHMENT PLUG CAP IS INSERTED. ALL | | | 15 AND 20 AMPERE, 125 AND 250 VOLT NONLOCKING | | | RECEPTACLES SHALL BE LISTED WEATHER-RESISTANT TYPE | | | ?WR?. | | | 8. NEC 210.63 HVAC EQUIPMENT SERVICE OUTLETS. A 125 | | | VOLT, SINGLE-PHASE, 15 OR 20 AMPERE-RATED RECEPTACLE | | | OUTLET SHALL BE INSTALLED AT AN ACCESSIBLE LOCATION FOR | | | THE SERVICING OF HVAC EQUIPMENT. THE RECEPTACLE SHALL | | | BE LOCATED WITHIN 25 FT. OF THE EQUIPMENT. ADDITIONAL | | | ROOFTOP OUTLETS ARE REQUIRED TO COMPLY. | | | 9. ALL SHOW WINDOW AND SIGN OUTLETS SHALL BE CONNECTED | | | VIA THE LIGHTING CONTACTOR FOR COMPLIANCE WITH FBC-E. | | | 10. NEC 760.41(B) THE BRANCH CIRCUIT SUPPLYING FIRE | | | ALARM EQUIPMENT SHALL SUPPLY NO OTHER LOADS AND BE | | | PERMANENTLY MARKED IN RED AND IDENTIFIED AS: "FIRE | | | ALARM CIRCUIT? AND BE ACCESSIBLE ONLY TO QUALIFIED | | | PERSONNEL. CIRCUIT 12 OF RPU, FIRE ALARM CIRCUIT SHALL | | | COMPLY. | | | 11. ALL BACKGROUND MUSIC SHALL BE AUTOMATICALLY MUTED | | | IN THE EVENT OF A FIRE ALARM CONDITION. | | | 12. FIRE ALARM WORK SHALL BE CONDUCTED UNDER A SEPARATE | | | PERMIT AND SUBMITTAL. | | | | | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | | RE-SUBMITTAL, YOU ARE REQUIRED TO PROVIDE A RESPONSE | | | LETTER (NARRATIVE) ADDRESSING EACH ITEM ALONG WITH THE | | | STANDARD CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE | | | INSERT CORRECTED PAGES INTO THE SUBMITTAL AND LEAVE THE | | | PREVIOUSLY REVIEWED SHEETS FOR COMPARISON. | | | CLOUDING THE CHANGES WILL BE GREATLY APPRECIATED. | | | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | | CONTACT ME DIRECTLY. | | | | | | THANK YOU, | | | MIKE ALBARRAN | | | ELECTRICAL PLANS EXAMINER | | | PH: 561-805-6746 | | | EMAIL: [email protected] | | | | | 2015-12-29 08:12:24 | ASSIGNED TO MALBARRAN |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
N |
Date |
2016-03-15 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2016-03-15 |
Time |
|
Rev Time |
0.00 |
| Received By |
mgonzale |
Date |
2016-03-15 |
Time |
|
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2015-12-29 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-12-29 |
Time |
08:12 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-12-29 |
Time |
08:12 |
Sent To |
|
|
| Notes |
| 2015-12-29 08:13:01 | PER MANNY GONZALEZ, WE HAVE BEEN WORKING WITH THE CIVIL | | | ENGINEER, AS OF LAST WEEK THEY WHERE IN THE PROCESS OF | | | REVISING PLANS TO ACCOMMODATE PBCOUNTY WATER AND SEWER | | | CONNECTIONS. YOU MAY PLACE AN "F" UNTIL ENGINEERING | | | RECEIVES REVISED PLANS. | | | THANK YOU! |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2016-02-09 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2016-02-09 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2016-02-09 |
Time |
16:29 |
Sent To |
|
|
| Notes |
| 2016-02-09 16:49:43 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | THESE COMMENTS WERE PREVIOUSLY POSTED AS PROVISO AND | | | REPOSTED FOR THIS REVIEW. | | | | | | 1. THE EXTERIOR EMERGENCY SHUT-OFF IS LOCATED IN AN | | | AREA THAT IS BLOCKED BY TABLES AND CHAIRS. THE SHUT-OFF | | | SHALL BE MOVED TO A MORE VISABLE AND ACCESSIBLE AREA | | | PER NFPA 30A, CHAPTER 6, | | | | | | 6.7 EMERGENCY ELECTRICAL DISCONNECTS. FUEL DISPENSING | | | SYSTEMS SHALL BE PROVIDED WITH ONE OR MORE CLEARLY | | | IDENTIFIED EMERGENCY SHUTOFF DEVICES OR ELECTRICAL | | | DISCONNECTS. SUCH DEVICES OR DISCONNECTS SHALL BE | | | INSTALLED IN APPROVED LOCATIONS | | | BUT NOT LESS THAN 6 M (20 FT) OR MORE THAN 30 M (100 | | | FT) FROM THE FUEL DISPENSING DEVICES THAT THEY SERVE. | | | EMERGENCY SHUTOFF DEVICES OR ELECTRICAL DISCONNECTS | | | SHALL DISCONNECT POWER TO ALL DISPENSING DEVICES; TO | | | ALL REMOTE PUMPS SERVING THE DISPENSING DEVICES; TO ALL | | | ASSOCIATED POWER, CONTROL, AND SIGNAL CIRCUITS; AND TO | | | ALL OTHER ELECTRICAL EQUIPMENT IN THE HAZARDOUS | | | (CLASSIFIED) LOCATIONS SURROUNDING THE FUEL DISPENSING | | | DEVICES. WHEN MORE THAN ONE EMERGENCY SHUTOFF DEVICE OR | | | ELECTRICAL DISCONNECT IS PROVIDED, ALL DEVICES SHALL BE | | | INTERCONNECTED.RESETTING FROM AN EMERGENCY SHUTOFF | | | CONDITION SHALL REQUIRE MANUAL INTERVENTION AND THE | | | MANNER OF RESETTING SHALL BE APPROVED BY THE AUTHORITY | | | HAVING JURISDICTION. | | | EXCEPTION: INTRINSICALLY SAFE ELECTRICAL EQUIPMENT NEED | | | NOT MEET THIS REQUIREMENT. | | | | | | 6.7.1 AT ATTENDED MOTOR FUEL DISPENSING FACILITIES, THE | | | DEVICES OR DISCONNECTS SHALL BE READILY ACCESSIBLE TO | | | THE ATTENDANT. | | | | | | 6.7.2 AT UNATTENDED MOTOR FUEL DISPENSING FACILITIES, | | | THE DEVICES OR DISCONNECTS SHALL BE READILY ACCESSIBLE | | | TO PATRONS AND AT LEAST ONE ADDITIONAL DEVICE OR | | | DISCONNECT SHALL BE READILY ACCESSIBLE TO EACH GROUP OF | | | DISPENSING DEVICES ON AN INDIVIDUAL ISLAND. | | | | | | 2. SHEET A 4 - PER FLORIDA 69A-60.0081; NOTICE SIGNAGE | | | IS REQUIRED FOR STRUCTURES WITH LIGHT-FRAME TRUSS-TYPE | | | CONSTRUCTION. ANY COMMERCIAL, INDUSTRIAL, OR ANY | | | MULTIUNIT RESIDENTIAL STRUCTURE OF THREE UNITS OR MORE | | | WHICH USES HORIZONTAL OR VERTICAL LIGHT-FRAME | | | TRUSS-TYPE CONSTRUCTION IN ANY PORTION SHALL BE MARKED | | | WITH A MALTESE CROSS SIGN MEASURING 8 INCHES | | | HORIZONTALLY AND 8 INCHES VERTICALLY, OF A BRIGHT RED | | | REFLECTIVE COLOR. THE APPROVED SYMBOL SHALL BE PLACED | | | WITHIN 24 INCHES TO THE LEFT OF THE MAIN ENTRY DOOR. | | | 1. STRUCTURES WITH LIGHT-FRAME TRUSS ROOFS SHALL BE | | | MARKED WITH THE LETTER "R". | | | 2. STRUCTURES WITH LIGHT-FRAME TRUSS FLOOR SYSTEMS | | | SHALL BE MARKED WITH THE LETTER "F". | | | 3. STRUCTURES WITH LIGHT-FRAME TRUSS FLOOR AND ROOF | | | SYSTEMS SHALL BE MARKED WITH THE LETTERS "R/F". | | | | | | THIS STRUCTURE REQUIRES A "R" SIGN. | | | | | | 3. SHEET A 1 - THE LOCKS ON DOORS V1 AND V2 SHALL | | | COMPLY WITH NFPA 101 CHAPTER 7 - A THUMB TURN LOCK IS | | | NOT PERMITTED ON THE MAIN ENTRY DOOR(S). IN LIEU OF | | | PANIC HARDWARE, THE MAIN ENTRY IS PERMITTED TO BE | | | EQUIPPED WITH A KEYED LOCK WITH LOCK/UNLOCK INDICATOR | | | WINDOW AND SIGNAGE STATING THE DOOR IS TO REMAIN | | | UNLOCKED DURING BUSINESS HOURS. NO OTHER LOCKING OR | | | LATCHING MECHANISMS ARE PERMITTED. | | | | | | 7.2.1.5.5.1 EXTERIOR DOOR ASSEMBLIES SHALL BE PERMITTED | | | TO HAVE KEY-OPERATED LOCKS FROM THE EGRESS SIDE, | | | PROVIDED THAT ALL OF THE FOLLOWING CRITERIA ARE MET. | | | (1) THIS ALTERNATIVE IS PERMITTED IN CHAPTERS 11 | | | THROUGH 43 FOR THE SPECIFIC OCCUPANCY. ( IT IS | | | PERMITTED UNDER CHAPTER 38, NEWBUSINESS OCCUPANCY, FOR | | | PRINCIPAL ENTRANCE EXIT DOORS.) | | | (2) A READILY VISIBLE, DURABLE SIGN IN LETTERS NOT LESS | | | THAN 1 IN. HIGH ON A CONTRASTING BACKGROUND THAT READS | | | AS FOLLOWS IS LOCATED ON OR ADJACENT TO THE DOOR LEAF. | | | THIS DOOR TO REMAIN UNLOCKED WHEN THE BUILDING IS | | | OCCUPIED. | | | (3) THE LOCKING DEVICE IS OF A TYPE THAT IS READILY | | | DISTINGUISHABLE AS LOCKED. | | | (4) A KEY IS IMMEDIATELY AVAILABLE TO ANY OCCUPANT | | | INSIDE THE BUILDING WHEN IT IS LOCKED. | | | SHOULD ALL OF THE ABOVE NOT BE POSSIBLE: | | | 7.2.1.5.1 DOOR LEAVES SHALL BE ARRANGED TO BE OPENED | | | READILY FROM THE EGRESS SIDE WHENEVER THE BUILDING IS | | | OCCUPIED. | | | 7.2.1.5.3 LOCKS, IF PROVIDED, SHALL NOT REQUIRE THE USE | | | OF A KEY, A TOOL, OR SPECIAL KNOWLEDGE OR EFFORT FOR | | | OPERATION FROM THE EGRESS SIDE. | | | 7.2.1.5.10 A LATCH OR OTHER FASTENING DEVICE ON A DOOR | | | LEAF SHALL BE PROVIDED WITH A RELEASING DEVICE THAT HAS | | | AN OBVIOUS METHOD OF OPERATION AND THAT IS READILY | | | OPERATED UNDER ALL LIGHTING CONDITIONS. | | | 7.2.1.5.10.2 THE RELEASING MECHANISM SHALL OPEN THE | | | DOOR LEAF WITH NOT MORE THAN ONE RELEASING OPERATION. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2015-11-19 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2015-11-19 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2015-11-18 |
Time |
11:02 |
Sent To |
|
|
| Notes |
| 2015-11-18 17:28:34 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | 1. SHEET A 4 - PER FLORIDA 69A-60.0081; NOTICE SIGNAGE | | | IS REQUIRED FOR STRUCTURES WITH LIGHT-FRAME TRUSS-TYPE | | | CONSTRUCTION. ANY COMMERCIAL, INDUSTRIAL, OR ANY | | | MULTIUNIT RESIDENTIAL STRUCTURE OF THREE UNITS OR MORE | | | WHICH USES HORIZONTAL OR VERTICAL LIGHT-FRAME | | | TRUSS-TYPE CONSTRUCTION IN ANY PORTION SHALL BE MARKED | | | WITH A MALTESE CROSS SIGN MEASURING 8 INCHES | | | HORIZONTALLY AND 8 INCHES VERTICALLY, OF A BRIGHT RED | | | REFLECTIVE COLOR. THE APPROVED SYMBOL SHALL BE PLACED | | | WITHIN 24 INCHES TO THE LEFT OF THE MAIN ENTRY DOOR. | | | 1. STRUCTURES WITH LIGHT-FRAME TRUSS ROOFS SHALL BE | | | MARKED WITH THE LETTER "R". | | | 2. STRUCTURES WITH LIGHT-FRAME TRUSS FLOOR SYSTEMS | | | SHALL BE MARKED WITH THE LETTER "F". | | | 3. STRUCTURES WITH LIGHT-FRAME TRUSS FLOOR AND ROOF | | | SYSTEMS SHALL BE MARKED WITH THE LETTERS "R/F". | | | | | | THIS STRUCTURE REQUIRES A "R" SIGN. | | | | | | 2. SHEET E 1 - THE INDICATED LOCATION OF THE OUTSIDE | | | EMEGERNCY SHUT OFF SWITCH IS NOT APPROVED. THE AREA | | | INDICATED IS NOT CLEARLY IDENTIFIED BEHIND SEATING AND | | | TABLES AND NEXT TO A TRASH CAN. AN ALTENATIVE LOCATION | | | SHALL BE COORDINATED WITH THE FIRE MARSHAL'S OFFICE. | | | PALCING IT NEXT TO THE FRONT DOORS IS RECOMMENDEDAND AS | | | LONG AS IT IS NOT LESS THAN 20FT OR MORE THAN 100FT | | | FROM THE FUEL DISPENSING DEVICES IT SERVES; NO | | | DIMENSIONS ARE PROVIDED. | | | | | | 3. SHEET E 9 - A CLASS A NFPA 72 COMPLIANT MONITORED | | | FIRE ALARM SYSTEM IS REQUIRED FOR THIS STRUCTURE. | | | SEPARATE SHOP DRAWINGS, ARE REQUIRED TO BE SUBMITTED, | | | REVIEWED AND APPROVED BY THE FIRE PREVENTION BUREAU | | | PRIOR TO ANY INSTALLATION. | | | | | | 4. SHEET A 1 - THE LOCKS ON DOORS V1 AND V2 SHALL | | | COMPLY WITH NFPA 101 CHAPTER 7 - A THUMB TURN LOCK IS | | | NOT PERMITTED ON THE MAIN ENTRY DOOR(S). IN LIEU OF | | | PANIC HARDWARE, THE MAIN ENTRY IS PERMITTED TO BE | | | EQUIPPED WITH A KEYED LOCK WITH LOCK/UNLOCK INDICATOR | | | WINDOW AND SIGNAGE STATING THE DOOR IS TO REMAIN | | | UNLOCKED DURING BUSINESS HOURS. NO OTHER LOCKING OR | | | LATCHING MECHANISMS ARE PERMITTED. | | | | | | 7.2.1.5.5.1 EXTERIOR DOOR ASSEMBLIES SHALL BE PERMITTED | | | TO HAVE KEY-OPERATED LOCKS FROM THE EGRESS SIDE, | | | PROVIDED THAT ALL OF THE FOLLOWING CRITERIA ARE MET. | | | (1) THIS ALTERNATIVE IS PERMITTED IN CHAPTERS 11 | | | THROUGH 43 FOR THE SPECIFIC OCCUPANCY. ( IT IS | | | PERMITTED UNDER CHAPTER 38, NEWBUSINESS OCCUPANCY, FOR | | | PRINCIPAL ENTRANCE EXIT DOORS.) | | | (2) A READILY VISIBLE, DURABLE SIGN IN LETTERS NOT LESS | | | THAN 1 IN. HIGH ON A CONTRASTING BACKGROUND THAT READS | | | AS FOLLOWS IS LOCATED ON OR ADJACENT TO THE DOOR LEAF. | | | THIS DOOR TO REMAIN UNLOCKED WHEN THE BUILDING IS | | | OCCUPIED. | | | (3) THE LOCKING DEVICE IS OF A TYPE THAT IS READILY | | | DISTINGUISHABLE AS LOCKED. | | | (4) A KEY IS IMMEDIATELY AVAILABLE TO ANY OCCUPANT | | | INSIDE THE BUILDING WHEN IT IS LOCKED. | | | SHOULD ALL OF THE ABOVE NOT BE POSSIBLE: | | | 7.2.1.5.1 DOOR LEAVES SHALL BE ARRANGED TO BE OPENED | | | READILY FROM THE EGRESS SIDE WHENEVER THE BUILDING IS | | | OCCUPIED. | | | 7.2.1.5.3 LOCKS, IF PROVIDED, SHALL NOT REQUIRE THE USE | | | OF A KEY, A TOOL, OR SPECIAL KNOWLEDGE OR EFFORT FOR | | | OPERATION FROM THE EGRESS SIDE. | | | 7.2.1.5.10 A LATCH OR OTHER FASTENING DEVICE ON A DOOR | | | LEAF SHALL BE PROVIDED WITH A RELEASING DEVICE THAT HAS | | | AN OBVIOUS METHOD OF OPERATION AND THAT IS READILY | | | OPERATED UNDER ALL LIGHTING CONDITIONS. | | | 7.2.1.5.10.2 THE RELEASING MECHANISM SHALL OPEN THE | | | DOOR LEAF WITH NOT MORE THAN ONE RELEASING OPERATION. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2016-10-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-10-13 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-09-21 |
Time |
13:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2016-08-31 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2016-08-31 |
Time |
08:33 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2016-08-12 |
Time |
12:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2016-05-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-05-14 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-04-14 |
Time |
12:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-03-15 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2016-03-15 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2016-02-03 |
Time |
09:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-01-04 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2016-01-04 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-10-28 |
Time |
13:59 |
Sent To |
|
|
| Notes |
| 2015-10-28 13:59:38 | C39 | | | TRAVELLING WITH 15100992 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
4 |
Status |
P |
Date |
2016-10-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-10-13 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-10-13 |
Time |
14:16 |
Sent To |
|
|
| Notes |
| 2016-10-13 14:19:04 | PALM BEACH COUNTY IMPACT FEE OFFICE | | | MU2016-22352 | | | 6119 SQ. FT. | | | CONVENINCE STORE | | | $4,704.84 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
F |
Date |
2016-08-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-08-26 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-08-26 |
Time |
16:38 |
Sent To |
|
|
| Notes |
| 2016-08-26 16:39:13 | IMPACT FEES | | | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2016-02-21 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-02-21 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-02-21 |
Time |
09:45 |
Sent To |
|
|
| Notes |
| 2016-02-21 09:46:20 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2015-11-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-11-23 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-11-23 |
Time |
06:53 |
Sent To |
|
|
| Notes |
| 2015-11-23 13:50:43 | IMPACT FEES | | | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2016-04-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-04-25 |
Time |
10:38 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-04-25 |
Time |
10:37 |
Sent To |
|
|
| Notes |
| 2017-02-01 09:09:25 | MECHANICAL PROVISO: | | | | | | SEPARATE PERMIT AND PLANS REQUIRED FOR REFRIGERATION. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2016-02-22 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-02-22 |
Time |
09:11 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-02-22 |
Time |
09:11 |
Sent To |
|
|
| Notes |
| 2016-02-22 09:50:16 | 2ND REVIEW: FBC 2014 MECHANICAL | | | PERMIT #15100991 | | | 2/22/16 | | | | | | 1) THE SUBMITTED AC CALCULATIONS INDICATE THE PROJECT | | | LOCATION AND DESIGN TEMPERATURES FOR ORLANDO, FLORIDA. | | | PLEASE REVISE THE CALCULATIONS USING THE CORRECT WEST | | | PALM BEACH LOCATION AND DESIGN TEMPERATURES. | | | 2) SHEET M3 & S1.1: AS NOTED ON THE THE MASTER BILT | | | ROOFTOP MECHANICAL UNIT DETAIL, PLEASE PROVIDE | | | STRUCTURAL DRAWINGS FOR THE CURB CONSTRUCTION, AND THE | | | PIPE HOOD SHOWN ON M2. | | | 3) M3: INDICATE THE SIZE OF CADMIUM SCREWS TO BE USED | | | FOR ATTACHING THE FAN TO EXHAUST FAN TO THE CURB. | | | 3) THE REVISED PLAN NOW IDICATES THE WALK-IN BOXES AND | | | REFRIGERATION SYSTEMS TO BE DONE UNDER SEPARATE PERMIT, | | | WHICH WOULD IMPLY THAT THE TOTAL VALUE FOR THAT PERMIT | | | WILL BE LABOR, MATERIALS AND EQUIPMENT. PLEASE CLARIFY | | | IF THE SEPARATE PERMIT WILL INCLUDE THE COST OF MASTER | | | BILT UNIT, AND THE COST OF MOUNTING THE UNIT AND THE | | | OTHER ROOFTOP REFRIGERATION CONDENSERS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2015-11-09 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-11-09 |
Time |
15:31 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-11-09 |
Time |
15:31 |
Sent To |
|
|
| Notes |
| 2015-11-09 16:43:50 | 1ST REVIEW: FBC 2014 MECHANICAL | | | PERMIT #15100991 | | | 11/9/15 | | | | | | 1) PROVIDE AC COOLING AND HEATING CALCULATIONS IN | | | ACCORDANCE WITH THE ASHRAE/ACCA STANDARD 183 OR ACCA | | | MANUAL N- REFER TO SECTION C403.2.1 FBC-14 ENERGY | | | CONSERVATION. | | | 2) THE COMPLIANCE DATA FOR THE AC SYSTEMS LISTED IN THE | | | ENERGY CALCULATION FORM 506-2014 DOES NOT MATCH THE | | | DATA IN THE AC SCHEDULE ON SHEET M3: PLEASE CORRECT. | | | 3) M3: CORRECT THE CFM/SF O/A CALCULATION FOR THE | | | RETAIL AREAS IN THE SCHEDULE PER TABLE 403.3: 0.12 CFM | | | PER SF. | | | 4) THE SUBMITTED RTU ROOF CURB CLIP CALCULATIONS ARE | | | BASED ON THE OUTDATED 2010 FBC AND DO NOT HAVE ORIGINAL | | | SIGNATURES AND SEALS FROM THE ENGINEER OF RECORD- REFER | | | TO SECTION 61G15-23.002 FAC AND PROVIDE ORIGINAL SIGNED | | | AND SEALED COPIES. PLEASE NOTE THAT THE CLIP CALCS SHOW | | | MECHANICAL ATTACHMENTS FOR THE CURBS AND RTU'S, HOWEVER | | | THE PLANS INDICATE WELDED ATTACHMENTS. PROVIDE | | | DOCUMENTATION OF APPROVAL FOR THIS TYPE OF CONNECTION | | | FROM THE AC MANUFACTURER. | | | 5) A SEPARATE PERMIT IS REQUIRED FOR THE WALK-IN BOXES | | | AND REFRIGERATION SYSTEMS. PLEASE PLACE A NOTE ON THE | | | PLAN ACCORDINGLY AND ADJUST THE VALUATION TO EXCLUDE | | | THIS PART OF THE PROJECT. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-04-29 |
Time |
15:15 |
Sent To |
|
|
| Notes |
| 2016-05-02 10:52:51 | PLUMBING PROVISO | | | 1. PROVIDE TWO SIGNED AND SEALED COPIES OF GREASE | | | INTERCEPTOR CALCULATIONS REFERENCING PDI G101 NOT FBC. | | | SHALL PROVIDE BEFORE ROUGH INSPECTION. PER WPB AMEND. | | | TO FBC SEC 107.2.1 | | | 2. PROVIDE TWO SETS OF APPROVED AND SIGNED AND SEALED | | | CIVIL PLANS BEFORE FIRST ROUGH INSPECTION. | | | PER WPB AMEND. TO FBC SEC 107.2.1 | | | | | | 3. HAND SINKS SHALL NOT BE CONNECTED TO GREASE DRAIN. | | | FBC PL 1003.3.1 | | | | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2016-02-17 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-02-17 |
Time |
13:49 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-02-17 |
Time |
13:49 |
Sent To |
|
|
| Notes |
| 2016-02-17 14:53:38 | | | | 2ND REVIEW: FBC 2014 | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | 1.CIVIL DRAWINGS ARE MARKED NOT APPROVED FOR | | | CONSTRUCTION PLEASE CLARIFY. | | | PER WPB AMEND. TO FBC SEC.107.2.1 | | | 2. SHT. C8NOTE ON SANITARY SEWER READS 2IN SS FORCE | | | MAIN UPSTREAM OF LIFT STATION LOOKS LIKE A TYPO PLEASE | | | CORRECT. | | | PER WPB AMEND. TO FBC SEC.107.2.1 | | | 3. SEPARATE PERMIT REQUIRED FOR BACK FLOW ON WATER | | | MAINS. | | | 4.SHT.C-14 DETAIL FOR GREASE INTERCEPTOR DOES NOT MATCH | | | APPROVED DETAIL FROM CITY STANDARD DETAIL GS-7 . SHT. | | | P-1 YOU ARE SHOWING TWO DIFFERENT DETAILS FOR GREASE | | | INTERCEPTOR PLEASE CLARIFY IF USING HYDRO-MECHANICAL | | | PROVIDE MANUFACTURE CALCULATIONS. | | | PER WPB AMEND. TO FBC SEC.107.2.1 | | | 5. BACKFLOW REQUIRED ON POWQERWASHER WATER SUPPLY. | | | PER WPB AMEND. TO FBC SEC.107.2.1 | | | 6. SHT. P1 PLEASE INDICATE WHAT IS BEING DRAINED INTO | | | HUB DRAIN NEXT TO FOOD SERVICE WALK IN REFRIDGE, BEHIND | | | EWC AND OUTSIDE RETAI;L WALKIN REFRIDGE ,HUB DRAINS | | | SHALL COMPLY WITH FBC PL SEC 1002.4 | | | 7.PROVIDE MANUFACTURE SPECS ON SANITIZER EQUIPMENT. | | | PER WPB AMEND. TO FBC SEC.107.2.1 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2015-11-09 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2015-11-09 |
Time |
10:26 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2015-11-09 |
Time |
10:26 |
Sent To |
|
|
| Notes |
| 2015-11-09 11:10:20 | | | | 1ST REVIEW: FBC 2014 | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS | | | | | | 1.PLEASE SUBMIT SIGNED AND SEALED CIVIL DRAWINGS | | | SHOWING SANITARY SEWER ,WATER SERVICE,AND STORM. | | | PER WPB AMEND.TO FBC SEC 107.2.1 | | | 2. SHEET P-3 IT APPEARS THAT HALF THE ROOF IS BEING | | | DRAINED BY A ROOF DRAIN AND HALF BY SCUPPERS PLEASE | | | CLARIFY. | | | 3. PROVIDE SIZING CALCULATIONS FOR ALL GUTTERS | | | ,SCUPPERS AND ROOF DRAINS. | | | PER WPB AMEND.TO FBC SEC 107.2.1.3 | | | 4.ALL DRAINS IN FOOD AND DRINK PREP AND SERVICE AREAS | | | SHALL BE ON THE GREASE SYSTEM. | | | PER FBC P SEC 1003.3.1 | | | 5. PLEASE PROVIDE MANUFACTURE SPEC SHEETS AND | | | INSTILLATION GUIDES FOR WATER SOFTENER, AND FILER | | | SYSTEMS, PRESSURE WASHER, SANITIZER , | | | PER.WPB AMEND.TO FBC SEC 107.2.1 | | | 6. SHEET P1 SHOW TRAP PRIMERS FOR ALL FLOOR DRAINS. | | | PER.WPB AMEND.TO FBC SEC 107.2.1 | | | | | | 1111.4 MINIMUM NUMBER OF ROOF DRAINS. | | | NOT LESS THAN TWO ROOF DRAINS SHALL BE INSTALLED IN | | | ROOF AREAS 10,000 SQUARE FEET (929 M2) OR LESS AND NOT | | | LESS THAN FOUR ROOF DRAINS SHALL BE INSTALLED IN ROOFS | | | OVER 10,000 SQUARE FEET (929 M 2 ) IN AREA. | | | | | | A COMPLETE COMPREHENSIVE REVIEW CAN NOT BE COMPLETED AT | | | THIS TIME DO TO LACK OF INFORMATION . THERE MAYBE | | | ADDITIONAL COMMENTS ON SECOND REVIEW WHEN INFO IS | | | PROVIDED. |
|
|
| Review Stop |
POLICE |
POLICE |
| Rev No |
1 |
Status |
P |
Date |
2016-06-01 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2016-06-01 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2016-06-01 11:32:41 | PER OFFICER SETH BUXTON. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2016-02-21 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-02-21 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-02-21 |
Time |
09:45 |
Sent To |
|
|
| Notes |
| 2016-02-21 09:48:45 | COMPLIED/ PROVISO: | | | SUBMITTED: ATAS DUTCH METAL ROOFING FL 3556R-5 SLOPED | | | ROOFS | | | | | | PROVISO: TO BE SUBMITTED AFTER MASTER PERMIT ISSUANCE. | | | FLAT ROOF, ROOFING PRODUCTS AND ASSEMBLIES,R-40 ROOF | | | TOP INSULATION, ASSEMBLIES FOR FLAT ROOF, ROOF TOP | | | EXHAUST FANS. | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2015-11-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-11-23 |
Time |
13:51 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-11-23 |
Time |
13:51 |
Sent To |
|
|
| Notes |
| 2015-11-23 13:54:10 | ROOFING PLAN REVIEW | | | W. P. B. PERMIT: 15100991 WAWA CONVENIENCE STORE | | | ADD: 1520 BELVEDERE RD. | | | CONT: TBD( TO BE DETERMINED) | | | TEL: 407-661-9100 X2462 | | | E-MAIL: [email protected] | | | | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: MON. NOV. 23/2015 | | | ACTION: DENIED | | | | | | 1) THE FRONT COVER SHEET LIST 6 PRODUCT APPROVALS TO BE | | | INSTALLED AT THIS JOBSITE LOCATION. PLEASE NOTE TO | | | SUBMIT THE FLORIDA APPROVAL NUMBER WITH THE REPORTS. | | | THE DUTCH SEAM METAL ROOFING REPORT DOES NOT SHOW UP ON | | | THE FLORIDA PRODUCT APPROVAL WEBSITE. IF THERE IS NO | | | FLORIDA APPROVAL YOU WILL NEED TO SUBMIT FOR EITHER A | | | LOCAL APPROVAL OR FOR A SITE SPECIFIC APPROVAL. FLORIDA | | | APPROVALS DO NOT START WITH MRD. THEY HAVE A FL NUMBER. | | | | | | SECTION 1707 ALTERNATIVE TEST PROCEDURE | | | 1707.1 GENERAL. IN THE ABSENCE OF APPROVED RULES OR | | | OTHER APPROVED STANDARDS, THE BUILDING OFFICIAL SHALL | | | MAKE, OR CAUSE TO BE MADE, THE NECESSARY TESTS AND | | | INVESTIGATIONS; OR THE BUILDING OFFICIAL SHALL ACCEPT | | | DULY AUTHENTICATED REPORTS FROM APPROVED AGENCIES IN | | | RESPECT TO THE QUALITY AND MANNER OF USE OF NEW | | | MATERIALS OR ASSEMBLIES AS PROVIDED FOR IN SECTION | | | 104.11. THE COST OF ALL TESTS AND OTHER INVESTIGATIONS | | | REQUIRED UNDER THE PROVISIONS OF THIS CODE SHALL BE | | | BORNE BY THE APPLICANT. | | | | | | 2A) BELOW IS A LIST OF COMPONENTS AND CLADDING FOR | | | PRODUCT APPROVALS THAT CAN BE SUBMITTED NOW OR MAY BE | | | CONSIDERED A DEFERRED SUBMITTAL (107.3.4.2.) 2010 FBC-B | | | 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.4.1 | | | COMPONENTS & CLADDING. FLORIDA DEPARTMENT OF COMMUNITY | | | AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF | | | PRODUCTS OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE | | | PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS. | | | (B) WINDOWS | | | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL | | | LOUVERS, EFIS SYSTEMS, | | | (D) ROOFING PRODUCTS AND ASSEMBLIES,R-40 ROOF TOP | | | INSULATION, ASSEMBLIES FOR FLAT & SLOPED, ROOF TOP | | | CURBS, ROOF TOP INTAKE & EXHAUST FANS | | | (E) SHUTTERS | | | (F) SKYLIGHTS | | | (G) EXTERIOR COOLER, FREEZERS & PRE-ENGINEERED A/C | | | STANDS | | | | | | 2B) 107.3.4.1 THOSE PRODUCTS WHICH ARE REGULATED BY DCA | | | RULE 9N-3SHALL BE REVIEWED AND APPROVED IN WRITING BY | | | THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. | | | | | | 3) NO FLAT ROOF PRODUCT APPROVAL, ROOF TOP CURBS, ROOF | | | TOP INTAKE & EXHAUST FANS NOR PRE-ENGINEERED A/C STANDS | | | WERE SUBMITTED. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
P |
Date |
2016-09-27 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2016-09-27 |
Time |
14:45 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2016-09-27 |
Time |
14:45 |
Sent To |
|
|
| Notes |
| 2016-09-27 14:58:35 | 9/27/16- WITH THE FOLLOWING PROVISO: | | | | | | * THE DEVELOPER SHALL PROVIDE A WRITTEN STATEMENT FROM | | | THE PALM BEACH COUNTY TRAFFIC DIVISION | | | CONFIRMING THAT ALL APPLICABLE PROPORTIONATE SHARE | | | PAYMENTS FOR THE IMPROVEMENTS AT THE | | | INTERSECTION OF BELVEDERE ROAD AND AUSTRALIAN AVENUE | | | HAVE BEEN MADE PRIOR TO FIRST INSPECTION. A | | | COPY OF THE WRITTEN STATEMENT SHALL BE PROVIDED TO THE | | | DEVELOPMENT SERVICES DEPARTMENT | | | ?PLANNING DIVISION. | | | | | | ADDITIONAL NOTES: | | | | | | * SEPARATE PERMIT APPLICATIONS REQUIRED FOR: | | | LANDSCAPING, SITE LIGHTING AND SIGNAGE. | | | | | | * ALL NEW PRIVATE DEVELOPMENT, NEW CONSTRUCTION, | | | RENOVATION OR REMODELING, WHERE THE TOTAL VERTICAL | | | CONSTRUCTION OF ALL BUILDINGS ON A PROJECT SITE ARE | | | EQUAL OR GREATER THAN $750,000.00 IS SUBJECT TO | | | THE ART IN PUBLIC PLACES (AIPP) REQUIREMENTS OUTLINE IN | | | CHAPTER 78, ARTICLE V, OF THE CITY?S CODE | | | OF ORDINANCES. PLEASE CONTACT SYBILLE WELTER, A PP | | | COORDINATOR @ (561) | | | 822?1521 FOR INFORMATION. | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
F |
Date |
2016-08-30 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2016-08-30 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2016-08-30 |
Time |
|
Sent To |
|
|
| Notes |
| 2016-08-30 17:18:40 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: | | | | | | 1.) SITE PLAN FOR THE WAWA DOES NOT REFLECT THE LATEST | | | CHANGES MADE TO THE SITE. LATEST APPROVED PLANS BY THE | | | PLANNING DIVISION MUST BE INCORPORATED AS PART OF THE | | | BUILDING PERMIT SET. (REFERENCE: PLANNING BOARD CASE | | | NO. 1670C, APPROVAL ISSUED ON 8/16/16) | | | | | | REVISIONS TO THE PLANS MAY RESULT IN ADDITIONAL | | | COMMENTS. PLEASE CONTACT LINDA LOUIE @ (561) 822-1458 | | | IF THERE ARE QUESTIONS. | | | | | | | | | PROVISO: | | | | | | * THE DEVELOPER SHALL PROVIDE A WRITTEN STATEMENT FROM | | | THE PALM BEACH COUNTY TRAFFIC DIVISION CONFIRMING THAT | | | ALL APPLICABLE PROPORTIONATE SHARE PAYMENTS FOR THE | | | IMPROVEMENTS AT THE INTERSECTION OF BELVEDERE ROAD AND | | | AUSTRALIAN AVENUE HAVE BEEN MADE PRIOR TO FIRST | | | INSPECTION. A COPY OF THE WRITTEN STATEMENT SHALL BE | | | PROVIDED TO THE DEVELOPMENT SERVICES DEPARTMENT | | | -PLANNING DIVISION. | | | | | | | | | ADDITIONAL NOTES: | | | | | | * SEPARATE PERMIT APPLICATIONS REQUIRED FOR: | | | LANDSCAPING, SITE LIGHTING AND SIGNAGE. | | | | | | * ALL NEW PRIVATE DEVELOPMENT, NEW CONSTRUCTION, | | | RENOVATION OR REMODELING, WHERE THE TOTAL VERTICAL | | | CONSTRUCTION OF ALL BUILDINGS ON A PROJECT SITE ARE | | | EQUAL OR GREATER THAN $750,000.00 IS SUBJECT TO THE ART | | | IN PUBLIC PLACES (AIPP) REQUIREMENTS OUTLINE IN CHAPTER | | | 78, ARTICLE V, OF THE CITY'S CODE OF ORDINANCES. PLEASE | | | CONTACT SYBILLE WELTER, AIPP COORDINATOR @ (561) | | | 822-1521 FOR INFORMATION. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2016-05-06 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2016-05-06 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2016-05-06 |
Time |
|
Sent To |
|
|
| Notes |
| 2016-05-06 12:11:40 | ** FAILED ** | | | | | | 1.) 11/16/15 & 2/25/16 REPEAT COMMENT: CONDITION #2 IN | | | THE SITE PLAN APPROVAL LETTER ISSUED BY THE PLANNING | | | DIVISION ON 10/16/2015 HAS NOT BEEN ADDRESSED. PER THE | | | SITE PLAN APPROVAL LETTER, CONDITION #2 MUST BE | | | ADDRESSED PRIOR TO BUILDING PERMIT APPROVAL. | | | | | | ADDITIONAL NOTES: | | | | | | * SEPARATE PERMIT APPLICATIONS REQUIRED FOR: | | | LANDSCAPING, SITE LIGHTING AND SIGNAGE. | | | | | | * ALL NEW PRIVATE DEVELOPMENT, NEW CONSTRUCTION, | | | RENOVATION OR REMODELING, WHERE THE TOTAL VERTICAL | | | CONSTRUCTION OF ALL BUILDINGS ON A PROJECT SITE ARE | | | EQUAL OR GREATER THAN $500,000.00 IS SUBJECT TO THE ART | | | IN PUBLIC PLACES (AIPP) REQUIREMENTS OUTLINE IN CHAPTER | | | 78, ARTICLE V, OF THE CITY'S CODE OF ORDINANCES. PLEASE | | | CONTACT SYBILLE WELTER, AIPP COORDINATOR @ (561) | | | 822-1521 FOR INFORMATION. | | | | | | REVISIONS TO THE PLANS MAY RESULT IN ADDITIONAL | | | COMMENTS. PLEASE CONTACT LINDA LOUIE @ (561) 822-1458 | | | IF THERE ARE QUESTIONS. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2016-02-25 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2016-02-25 |
Time |
13:28 |
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2016-02-25 |
Time |
13:28 |
Sent To |
|
|
| Notes |
| 2016-02-25 13:29:40 | ** FAILED ** | | | | | | 1.) 11/16/15 REPEAT COMMENT CONDITION #2 IN THE SITE | | | PLAN APPROVAL LETTER ISSUED BY THE PLANNING DIVISION ON | | | 10/16/2015 HAS NOT BEEN ADDRESSED. PER THE SITE PLAN | | | APPROVAL LETTER, CONDITION #2 MUST BE ADDRESSED PRIOR | | | TO BUILDING PERMIT APPROVAL. | | | | | | | | | | | | ADDITIONAL NOTES: | | | | | | * SEPARATE PERMIT APPLICATIONS REQUIRED FOR: | | | LANDSCAPING, SITE LIGHTING AND SIGNAGE. | | | | | | * ALL NEW PRIVATE DEVELOPMENT, NEW CONSTRUCTION, | | | RENOVATION OR REMODELING, WHERE THE TOTAL VERTICAL | | | CONSTRUCTION OF ALL BUILDINGS ON A PROJECT SITE ARE | | | EQUAL OR GREATER THAN $500,000.00 IS SUBJECT TO THE ART | | | IN PUBLIC PLACES (AIPP) REQUIREMENTS OUTLINE IN CHAPTER | | | 78, ARTICLE V, OF THE CITY'S CODE OF ORDINANCES. PLEASE | | | CONTACT SYBILLE WELTER, AIPP COORDINATOR @ (561) | | | 822-1521 FOR INFORMATION. | | | | | | * PLEASE CONTACT LINDA LOUIE @ (561) 822-1458 IF YOU | | | HAVE QUESTIONS. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2015-11-16 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2015-11-16 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2015-11-13 |
Time |
16:04 |
Sent To |
|
|
| Notes |
| 2015-11-16 10:57:06 | ** FAILED ** | | | | | | 1.) SITE PLAN SHOWING THE GENERAL CIRCULATION, LOCATION | | | OF PARKING, BUILDING ORIENTATION ON THE SITE, SITE DATA | | | INFORMATION, ETC., IS AN INTEGRAL PART OF PERMIT | | | SUBMITTAL; HOWEVER, THE PLAN SEEMS TO BE MISSING FROM | | | THE PERMIT APPLICATION. PLEASE PROVIDE. | | | | | | 2.) CONDITION #2 IN THE SITE PLAN APPROVAL LETTER | | | ISSUED BY THE PLANNING DIVISION ON 10/16/2015 HAS NOT | | | BEEN ADDRESSED. PER THE SITE PLAN APPROVAL LETTER, | | | CONDITION #2 MUST BE ADDRESSED PRIOR TO BUILDING PERMIT | | | APPROVAL. | | | | | | 3.) ALL ROOFTOP MECHANICAL EQUIPMENT SHALL BE SCREENED | | | FROM VIEW BY THE BUILDING'S PARAPET. THE BUILDING | | | ELEVATIONS DO NOT SEEM TO ADDRESS THIS CONDITION OF | | | SITE PLAN APPROVAL. (REFERENCE SITE PLAN APPROVAL | | | LETTER ISSUED BY THE PLANNING DEPARTMENT ON 10/16/15) | | | | | | 4.) ONLY THREE (3) WALL SIGNS ARE PERMITTED ON THE | | | BUILDING. THE NUMBER OF SIGNS PROPOSED ON THE BUILDING | | | ELEVATIONS DOES NOT MATCH THE APPROVED ELEVATIONS. | | | ACCORDING TO THE APPROVED PLANS, THERE IS NO WALL | | | SIGNAGE PROPOSED ON THE EAST ELEVATION. PLEASE CORRECT. | | | | | | 5.) LABEL ALL ELEVATIONS WITH DIRECTIONS (I.E. NORTH, | | | SOUTH, EAST AND WEST). | | | | | | 6.) SEPARATE PERMIT APPLICATIONS REQUIRED FOR: | | | LANDSCAPING, SITE LIGHTING AND SIGNAGE. | | | | | | 7.) THE CITY OF WEST PALM BEACH POLICE DEPARTMENT - | | | CRIME PREVENTION UNIT SHALL REVIEW AND APPROVE ALL | | | CONSTRUCTION DRAWINGS TO ENSURE ADHERENCE TO | | | GENERALLY-ACCEPTED CRIME PREVENTION THROUGH | | | ENVIRONMENTAL DESIGN PRINCIPALS, AS WELL AS COMPLIANCE | | | WITH ALL LOCAL AND STATE REGULATIONS PERTAINING TO THE | | | PROPOSED USE. SUCH SUBMITTAL SHALL INCLUDE A | | | CONSTRUCTION SITE SECURITY AND MANAGEMENT PLAN. | | | | | | 8.) ALL NEW PRIVATE DEVELOPMENT, NEW CONSTRUCTION, | | | RENOVATION OR REMODELING, WHERE THE TOTAL VERTICAL | | | CONSTRUCTION OF ALL BUILDINGS ON A PROJECT SITE ARE | | | EQUAL OR GREATER THAN $500,000.00 IS SUBJECT TO THE ART | | | IN PUBLIC PLACES (AIPP) REQUIREMENTS OUTLINE IN CHAPTER | | | 78, ARTICLE V, OF THE CITY'S CODE OF ORDINANCES. PLEASE | | | CONTACT SYBILLE WELTER, AIPP COORDINATOR @ (561) | | | 822-1521 FOR INFORMATION. | | | | | | PLEASE CONTACT LINDA LOUIE @ (561) 822-1458 IF YOU HAVE | | | QUESTIONS. | | | |
|
|
|