Plan Review Details - Permit 15100760
| Plan Review Stops For Permit 15100760 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2015-11-02 |
|
|
Cont ID |
|
| Sent By |
cc |
Date |
2015-11-02 |
Time |
11:40 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2015-11-02 |
Time |
11:19 |
Sent To |
E |
|
| Notes |
| 2015-11-02 11:40:35 | ELECTRICAL PERMIT REQUIRED FOR WORK ON THIS PLAN | | | 11/2/2015 PP |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2015-10-27 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2015-10-27 |
Time |
13:05 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2015-10-27 |
Time |
13:03 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-12-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-12-28 |
Time |
07:51 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-12-23 |
Time |
15:04 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-11-02 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-10-28 |
Time |
08:32 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2015-10-21 |
Time |
14:20 |
Sent To |
|
|
| Notes |
| 2015-10-21 14:20:23 | ROUTED TO FIRE |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2015-12-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-12-28 |
Time |
07:51 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-12-28 |
Time |
07:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2015-10-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-10-28 |
Time |
08:33 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-10-28 |
Time |
08:33 |
Sent To |
|
|
| Notes |
| 2015-10-28 08:52:25 | 1ST REVIEW: FBC 2014 MECHANICAL | | | PERMIT #15100760 | | | 10/28/15 | | | | | | 1) REFER TO SECTION 508.1.1 MAKEUP AIR TEMPERATURE. | | | THE TEMPERATURE DIFFERENTIAL BETWEEN MAKEUP AIR AND THE | | | AIR IN THE CONDITIONED SPACE SHALL NOT EXCEED 10?F | | | (6?C) EXCEPT WHERE THE ADDED HEATING AND COOLING LOADS | | | OF THE MAKEUP AIR DO NOT EXCEED THE CAPACITY OF THE | | | HVAC SYSTEM. | | | PLEASE REVISE THE PLAN TO INDICATE COMPLIANCE. | | | 2) REFER TO SECTION 507.9 CLEARANCES FOR TYPE I HOOD, | | | AND REVISE THE PLAN TO INDICATE COMPLIANCE. | | | A TYPE I HOOD SHALL BE INSTALLED WITH A CLEARANCE TO | | | COMBUSTIBLES OF NOT LESS THAN 18 INCHES (457 MM). | | | EXCEPTION: CLEARANCE SHALL NOT BE REQUIRED FROM GYPSUM | | | WALLBOARD OR 1/2-INCH (12.7 MM) OR THICKER CEMENTITIOUS | | | WALLBOARD ATTACHED TO NONCOMBUSTIBLE STRUCTURES | | | PROVIDED THAT A SMOOTH, CLEANABLE, NONABSORBENT AND | | | NONCOMBUSTIBLE MATERIAL IS INSTALLED BETWEEN THE HOOD | | | AND THE GYPSUM OR CEMENTITIOUS WALLBOARD OVER AN AREA | | | EXTENDING NOT LESS THAN 18 INCHES (457 MM) IN ALL | | | DIRECTIONS FROM THE HOOD. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
|