Plan Review Details - Permit 15100707
Plan Review Stops For Permit 15100707
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2016-07-29 Cont ID  
Sent By jwitmer Date 2016-07-29 Time 06:30 Rev Time 0.00
Received By jwitmer Date 2016-07-29 Time 05:45 Sent To  
Notes
2016-07-29 06:14:33BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15100707
 ADD: 831 BELVEDERE RD.
 CONT: AJS BUILDING & RENOVATIONS, INC.
 TEL: (407)298-9700
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 5TH REVIEW
 DATE: FRI. JULY 29/2016
 ACTION: BUILDING PROVISO
  
 1) THE ROOFING PRODUCT APPROVAL (MARATHON 25 AR AND CRC
 SUPERGLASS 25 AR/ NOA: 15-0211.08) EXPIRED 05/05/2016,
 THE CONTRACTOR WILL NEED TO SUBMIT, A CURRENT ROOFING
 PRODUCT APPROVAL, THE DESIGNER OF RECORD OR CONTRACTOR
 WILL NEED TO IDENTIFY THE ROOFING SUB-SYSTEM TO BE
 INSTALLED AND THE ASSOCIATED PRESSURES, SEE MAXIMUM
 DESIGN PRESSURES AND LIMITATIONS, EITHER 7 OR 9.
 107.3.4.1 THOSE PRODUCTS WHICH ARE REGULATED BY DCA
 RULE 9N-3 SHALL BE REVIEWED AND APPROVED IN WRITING BY
 THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2016-06-20 Cont ID  
Sent By jwitmer Date 2016-06-20 Time   Rev Time 0.00
Received By jwitmer Date 2016-06-20 Time   Sent To  
Notes
2016-06-20 10:18:23BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15100707
 ADD: 831 BELVEDERE RD.
 CONT: AJS BUILDING & RENOVATIONS, INC.
 TEL: (407)298-9700
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 4TH REVIEW
 DATE: MON. JUNE 20 /2016
 ACTION: DENIED
  
 1-3) COMPLIED
  
 4) NEW COMMENT. THIS COMMENT DEALS WITH THE SAME ISSUE,
 JUST REPHRASED. I'VE SPOKEN WITH OUR ASSISTANT BUILDING
 OFFICIAL ABOUT HOW I'VE WORDED THIS COMMENT, HE AGRESS
 THAT A ROOFING PRODUC APPROVAL WOULD NOT BE REQUIRED
 FOR THE ANCHORING OF THE A/C STAND TO THE CONCRETE
 ROOF. HE BELIEVES THERE SHOULD BE A DETAIL SHOWING HOW
 THE ROOF WILL BE SEALED WHERE THE PENETRATION IS MADE
 FOR THE ANCHORING OF THE STAND INTO THE CONCRETE ROOF
 DECK. TYPICAL DETAIL MAY INCLUDE A PITCH CUP SHOW IF
 THE HORIZONTAL LEG PORTION IS BENT IN OR BENT OUT. THE
 TYPE OF MATERIAL AND GAUGE OF THE PITCH CUP. IF THE
 HORIZONTAL LEG OF THE PITCH CUP IS COPPER, HOW IT WILL
 BE ISOLATED FROM THE ALUMINUM A/C STAND LEG AND ANCHOR
 PLATE. TYPE AND SIZE OF ANCHOR FOR BOTH THE PITCH CUP
 AND A/C STAND.
 TYPE OF MATERIAL TO FILL THE PITCH CUP AND THE MATERIAL
 TO SEAL THE ROOFING ON THE OUTSIDE OF THE PITCH CUP.
 PLEASE PROVIDE A DIAGRAM WITH THIS INFORMATION.
 107.2.1.2 FOR ROOF ASSEMBLIES REQUIRED BY THE CODE, THE
 CONSTRUCTION DOCUMENTS SHALL ILLUSTRATE, DESCRIBE AND
 DELINEATE THE TYPE OF ROOFING SYSTEM, MATERIALS,
 FASTENING REQUIREMENTS, FLASHING REQUIREMENTS AND WIND
 RESISTANCE RATING THAT ARE REQUIRED TO BE INSTALLED.
  
 PREVIOUS COMMENT. 2ND REQUEST. SEMI-COMPLIED. THE
 ROOFING PRODUCT APPROVAL WAS SUBMITTED, THE CONTRACTOR
 NOR THE DESIGNER OF RECORD HAS IDENTIFIED THE ROOFING
 SUB-SYSTEM TO BE INSTALLED AND THE ASSOCIATED
 PRESSURES, SEE MAXIMUM DESIGN PRESSURES AND
 LIMITATIONS, EITHER 7 OR 9. 107.3.4.1 THOSE PRODUCTS
 WHICH ARE REGULATED BY DCA RULE 9N-3 SHALL BE REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR
 TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
  
 5-8) COMPLIED
  
 9) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2016-05-06 Cont ID  
Sent By jwitmer Date 2016-05-06 Time 17:53 Rev Time 0.00
Received By jwitmer Date 2016-05-06 Time 16:44 Sent To  
Notes
2016-05-06 17:52:58BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15100707
 ADD: 831 BELVEDERE RD.
 CONT: AJS BUILDING & RENOVATIONS, INC.
 TEL: (407)298-9700
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 3RD REVIEW
 DATE: FRI. MAY /2016
 ACTION: DENIED
  
 1-3) COMPLIED
  
 4)2ND REQUEST. SEMI-COMPLIED. THE ROOFING PRODUCT
 APPROVAL WAS SUBMITTED, THE CONTRACTOR NOR THE DESIGNER
 OF RECORD HAS IDENTIFIED THE ROOFING SUB-SYSTEM TO BE
 INSTALLED AND THE ASSOCIATED PRESSURES, SEE MAXIMUM
 DESIGN PRESSURES AND LIMITATIONS, EITHER 7 OR 9.
 107.3.4.1 THOSE PRODUCTS WHICH ARE REGULATED BY DCA
 RULE 9N-3 SHALL BE REVIEWED AND APPROVED IN WRITING BY
 THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL.
  
  
 5) COMPLIED
  
 6) 2ND RESPONSE, SEMI COMPLIED. THE ENERGY GUAGE CHECK
 LIST CHECK LIST SUBMITTED.
 PAGE 7 OF 12 THE BOXES ARE NOT CHECKED OF BY THE
 DESIGNER OR ENGINEER
 PAGE 3 OF 12 NOT SIGNED BY THE OWNER AGENT (CONTRACTOR)
  
 7-8) COMPLIED.
  
 9) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2016-01-20 Cont ID  
Sent By jwitmer Date 2016-01-20 Time 07:32 Rev Time 0.00
Received By jwitmer Date 2016-01-20 Time 06:24 Sent To  
Notes
2016-01-20 07:52:05BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15100707
 ADD: 831 BELVEDERE RD.
 CONT: AJS BUILDING & RENOVATIONS, INC.
 TEL: (407)298-9700
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: WED. JAN. 20/2016
 ACTION: DENIED
  
 1) 2ND REQUEST. RESPONSE INDICATES THE DESIGN PRESSURES
 FOR NEW WINDOWS AND DOORS THE CALCULATIONS ARE
 ATTACHED. THE WIND DESIGN CRITERIA AND ASSOCIATED
 PRESSURES ARE CORRECT. THE WIND DESIGN CRITERIA AND
 PRESSURES ARE FROM VVS ENGINEERING; THEY ARE NOT SIGNED
 NOR SEALED. . PLANS, SPECIFICATIONS, REPORTS OR OTHER
 DOCUMENTS PREPARED BY THE DESIGN PROFESSIONAL AND BEING
 FILED FOR PUBLIC RECORD SHALL HAVE THE SIGNATURE AND
 SEAL OF THE DESIGN PROFESSIONAL AFFIXED TO THE
 DOCUMENT.
 FL ADMIN CODE 61G15-23.002 ENGINEERS
 EFFECTIVE DATE 05/06/2009
  
 FL 61G-15-30.006 (3) THE DELEGATED ENGINEER SHALL
 FORWARD THE DELEGATED ENGINEERING DOCUMENTS TO THE
 ENGINEER OF RECORD FOR REVIEW. THE ENGINEER OF RECORD
 JOHN STOPPI P. E. SHOULD APPLY HIS SHOP DRAWING STAMP
 REVIEWED AND APPROVED.
  
  
 ORIGINAL COMMENT # 1. SHEET A4 BUILDING EAST ELEVATION
 SHOWS PRESSURES FOR A NEW REPLACEMENT DOOR/SIDELITE AND
 (2) WINDOWS. BOTH ARE INDICATED AS DESIGN PRESSURES BUT
 THE DOOR AND SIDELITE APPEAR TO BE VULT PRESSURES
 -70.84. 2014 FBC-B TABLE 1609.6.2.
  
 2) THERE IS STILL (2) ISSUES, THE FLORIDA COVERSHEET
 FOR THE PGT PRODUCTS WAS NOT SUBMITTED, THE SECOND
 ISSUE IS COMPLIANCE WITH THE 2014 FLORIDA BUILDING CODE
 W 2014 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION 107.3.4.1
 THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE 9N-3
 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL. NONE OF THE (3) PRODUCT
 APPROVALS HAVE BEEN REVIEWED BY THE DESIGNER OF RECORD
 FOR THE JOB.
 ORIGINAL COMMENT # 2. THE 2 SUBMITTED REPORTS FROM
 KEYSTONE AND PGT DO NOT HAVE IDENTIFICATION AS TO IF
 THESE REPORTS ARE FLORIDA APPROVALS OR IF THEY ARE A
 MIAMI-DADE NOA, PLEASE PROVIDE THE COVERSHEETS
 IDENTIFYING THE SOURCE OF EACH OF THESE REPORTS. 2014
 FBC-B 16-0.1.2 PROTECTION OF OPENINGS.
  
 3) COMPLIED. SHEET A4 SECTION # 1 METAL CANOPY FRAMING
 DOES NOT INDICATE THE FRAMING MATERIAL, SIZE OF FRAMING
 MEMBER, CENTER TO CENTER OF FRAMING MEMBERS, LOADS THEY
 CAN CARRY, IF STIFF BACKS ARE REQUIRED, BRACING, NOR
 DOES THE PLANS SHOW THE TYPE OF ROOF SHEATHING,
 THICKNESS, FACIA, SOFFIT MATERIAL IS NOT IDENTIFIED,
 THE TOP OF THE PARAPET AND NEW MANSARD ROOF FRAMING
 DOES NOT PROVIDE WHAT TYPE OF COPYING DETAIL WILL BE
 USED IN THIS INSTALLATION. 107.3.5.1 MINIMUM PLAN
 REVIEW CRITERIA FOR COMMERCIAL BUILDINGS. A THOROUGH
 REVIEW CANNOT BE MADE AT THIS TIME, AS A RESULT OF THE
 ADDITIONAL INFORMATION REQUESTED ADDITIONAL COMMENTS
 MAY APPEAR THAT WERE NOT PART OF THIS REVIEW.
  
 4) SEMI-COMPLIED. THE ROOFING PRODUCT APPROVAL WAS
 SUBMITTED, THE CONTRACTOR NOR THE DESIGNER OF RECORD
 HAS IDENTIFIED THE ROOFING SUB-SYSTEM TO BE INSTALLED
 AND THE ASSOCIATED PRESSURES, SEE MAXIMUM DESIGN
 PRESSURES AND LIMITATIONS, EITHER 7 OR 9. 107.3.4.1
 THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE 9N-3
 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL.
  
  
 THE SUBMITTED A/C ALUMINUM ROOF STAND PLEASE HAVE THE
 DESIGNER OF RECORD REVIEW AND APPROVE THE PRODUCT
 APPROVAL AND APPLY THEIR SHOP DRAWING STAMP OF
 APPROVAL. 107.3.4.1 THOSE PRODUCTS WHICH ARE REGULATED
 BY DCA RULE 9N-3 SHALL BE REVIEWED AND APPROVED IN
 WRITING BY THE DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.
  
 ORIGINAL COMMENT # 4.THIS REVIEW CYCLE NO ROOFING
 PRODUCT APPROVALS WERE SUBMITTED. PLEASE PROVIDE
 COMPLIANCE WITH: 1609.6.4.4.1 COMPONENTS & CLADDING.
 FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV.
 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION
 SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS:
 (31) (D) ROOFING PRODUCTS AND ASSEMBLIES
 (G) PRE-ENGINEERED ROOFTOP A/C STANDS
  
 5) 2ND REQUEST. COMMENT NOT RESPONDED TOO, THE ORIGINAL
 M1SHEET LEFT IN THE OLD SET OF PLANS. SHEET M1 SHOWS A
 DETAIL FOR A ROOF TOP A/C CONDENSING STAND. PLEASE NOTE
 THE STAND WILL REQUIRE A PRODUCT APPROVAL TO BE
 SUBMITTED FOR REVIEW. PLEASE NOTE ADDITIONAL
 INFORMATION WILL BE REQUIRED AS TO THE TYPE OF ROOF
 DECK IS ON THE EXISTING BUILDING. SHEET A4 THE BUILDING
 SECTION IT APPEARS THE ROOF DECK IS WOOD WITH WOOD
 CEILING JOIST/ RAFTERS WHERE AS THE MECHANICAL PLAN M1
 THE ROOF DECK IS A CONCRETE DECK. DISCREPANCY IN PLANS.
 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED.
  
 6) 2ND RESPONSE, NOT RESPONDED TOO. PLEASE NOTE THE
 PALM BEACH COUNTY PROPERTY APPRAISERS OFFICE INDICATES
 FOR 2015 THE IMPROVEMENT VALUE OF THE BUILDING IS
 $42,253 DOLLARS IN VALUE.
 CHAPTER 2 DEFINITIONS (C) RENOVATED BUILDING. A
 RESIDENTIAL OR NONRESIDENTIAL BUILDING UNDERGOING
 ALTERATION THAT VARIES OR CHANGES INSULATION, HVAC
 SYSTEMS, WATER HEATING SYSTEMS, OR EXTERIOR ENVELOPE
 CONDITIONS, PROVIDED THE ESTIMATED COST OF RENOVATION
 EXCEEDS 30 PERCENT OF THE ASSESSED VALUE OF THE
 STRUCTURE.
  
  
 2014 FBC-ENERGY CODE C101.5 COMPLIANCE. COMMERCIAL
 BUILDINGS SHALL MEET THE COMMERCIAL PROVISIONS.
  
 C101.5.1 COMPLIANCE MATERIALS. THE FLORIDA BUILDING
 COMMISSION SHALL APPROVE SPECIFIC COMPUTER SOFTWARE.
 THE CODE OFFICIAL SHALL BE PERMITTED TO APPROVE
 WORKSHEETS, COMPLIANCE MANUALS AND OTHER SIMILAR
 MATERIALS THAT MEET THE INTENT OF THIS CODE.
  
 C101.5.1.1 ALTERATIONS, RENOVATIONS AND BUILDING
 SYSTEMS. ALTERATIONS, RENOVATIONS AND BUILDING SYSTEMS
 MAY UTILIZE FORM C402. FORM C402 CAN BE FOUND IN
 APPENDIX C.
  
  
 C401.2 APPLICATION. COMMERCIAL BUILDINGS SHALL COMPLY
 WITH ONE OF THE FOLLOWING:
 C401.2.1 APPLICATION TO EXISTING BUILDINGS.
 ADDITIONS, ALTERATIONS AND REPAIRS TO EXISTING
 BUILDINGS SHALL COMPLY WITH ONE OF THE FOLLOWING:
 1. SECTIONS C402, C403, C404 AND C405; OR
 2. ANSI/ASHRAE/IESNA 90.1.
  
 7) NEW COMMENT. MISSING A1 SHEET LEFT IN THE OLD SET OF
 PLANS.
  
 8) ALL SHEETS SIGNED AND SEALED BY JOHN P. STOPPI JR.
 P.E. 78807 ARE PHOTOCOPIED SIGNATURES NOT ORIGINAL
 SIGNATURE.
 PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS
 PREPARED BY THE DESIGN PROFESSIONAL AND BEING FILED FOR
 PUBLIC RECORD SHALL HAVE THE SIGNATURE AND SEAL OF THE
 DESIGN PROFESSIONAL AFFIXED TO THE DOCUMENT.
 FL ADMIN CODE 61G15-23.002 ENGINEERS
 EFFECTIVE DATE 05/06/2009
  
 9) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-11-06 Cont ID  
Sent By jwitmer Date 2015-11-06 Time 09:19 Rev Time  
Received By jwitmer Date 2015-11-06 Time 07:01 Sent To  
Notes
2015-11-06 08:41:32BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15100707
 ADD: 831 BELVEDERE RD.
 CONT: AJS BUILDING & RENOVATIONS, INC.
 TEL: (407)298-9700
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: FRI. NOV. 06/2015
 ACTION: DENIED
  
 1) SHEET A4 BUILDING EAST ELEVATION SHOWS PRESSURES FOR
 A NEW REPLACEMENT DOOR/SIDELITE AND (2) WINDOWS. BOTH
 ARE INDICATED AS DESIGN PRESSURES BUT THE DOOR AND
 SIDELITE APPEAR TO BE VULT PRESSURES -70.84. 2014 FBC-B
 TABLE 1609.6.2.
  
 2) THE 2 SUBMITED REPORTS FROM KEYSTONE AND PGT DO NOT
 HAVE IDENTIFICATION AS TO IF THESE REPORTS ARE FLORIDA
 APPROVALS OR IF THEY ARE A MIAMI-DADE NOA, PLEASE
 PROVIDE THE COVERSHEETS IDENTIFYING THE SOURCE OF EACH
 OF THESE REPORTS. 2014 FBC-B 16-0.1.2 PROTECTION OF
 OPENINGS.
  
 3) SHEET A4 SECTION # 1 METAL CANOPY FRAMING DOES NOT
 INDICATE THE FRAMING MATERIAL, SIZE OF FRAMING MEMBER,
 CENTER TO CENTER OF FRAMING MEMBERS, LOADS THEY CAN
 CARRY, IF STIFFBACKS ARE REQUIRED, BRACING, NOR DOES
 THE PLANS SHOW THE TYPE OF ROOF SHEATHING, THICKNESS,
 FACIA, SOFFIT MATERIAL IS NOT IDENTIFIED, THE TOP OF
 THE PARAPET AND NEW MANSARD ROOF FRAMING DOES NOT
 PROVIDE WHAT TYPE OF COPYING DETAIL WILL BE USED IN
 THIS INSTALATION. 107.3.5.1 MINIMUM PLAN REVIEW
 CRITERIA FOR COMMERCIAL BUILDINGS. A THOROUGH REVIEW
 CANNOT BE MADE AT THIS TIME, AS A RESULT OF THE
 ADDITIONAL INFORMATION REQUESTED ADDITIONAL COMMENTS
 MAY APPEAR THAT WERE NOT PART OF THIS REVIEW.
  
 4) THIS REVIEW CYCLE NO ROOFING PRODUCT APPROVALS WERE
 SUBMITTED. PLEASE PROVIDE COMPLIANCE WITH: 1609.6.4.4.1
 COMPONENTS & CLADDING. FLORIDA DEPARTMENT OF COMMUNITY
 AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF
 PRODUCTS OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE
 PRODUCT APPROVALS:
 (31) (D) ROOFING PRODUCTS AND ASSEMBLIES
 (G) PRE-ENGINEERED ROOFTOP A/C STANDS
  
 5) SHEET M1 SHOWS A DETAIL FOR A ROOF TOP A/C
 CONDENSING STAND. PLEASE NOTE THE STAND WILL REQUIRE A
 PRODUCT APPROVAL TO BE SUBMITTED FOR REVIEW. PLEASE
 NOTE ADDITIONAL INFORMATION WILL BW REQUIRED AS TO THE
 TYPE OF ROOF DECK IS ON THE EXISITNG BUILDING. SHEET A4
 THE BUILDING SECTION IT APPEARS THE ROOF DECK IS WOOD
 WITH WOOD CEILING JOIST/ RAFTERS WHERE AS THE
 MECHANICAL PLAN M1 THE ROOF DECK IS A CONCRETE DECK.
 DISCREPANCY IN PLANS. 107.2.1.3 ADDITIONAL INFORMATION
 IS REQUIRED.
  
 6) PLEASE NOTE THE PALM BEACH COUNTY PROPERTY
 APPRAISERS OFFICE INDICATES FOR 2015 THE IMPROVEMENT
 VALUE OF THE BUILDING IS $42,253 DOLLARS IN VALUE.
 CHAPTER 2 DEFINITIONS (C) RENOVATED BUILDING. A
 RESIDENTIAL OR NONRESIDENTIAL BUILDING UNDERGOING
 ALTERATION THAT VARIES OR CHANGES INSULATION, HVAC
 SYSTEMS, WATER HEATING SYSTEMS, OR EXTERIOR ENVELOPE
 CONDITIONS, PROVIDED THE ESTIMATED COST OF RENOVATION
 EXCEEDS 30 PERCENT OF THE ASSESSED VALUE OF THE
 STRUCTURE.
  
  
 2014 FBC-ENERGY CODE C101.5 COMPLIANCE. COMMERCIAL
 BUILDINGS SHALL MEET THE COMMERCIAL PROVISIONS.
  
 C101.5.1 COMPLIANCE MATERIALS. THE FLORIDA BUILDING
 COMMISSION SHALL APPROVE SPECIFIC COMPUTER SOFTWARE.
 THE CODE OFFICIAL SHALL BE PERMITTED TO APPROVE
 WORKSHEETS, COMPLIANCE MANUALS AND OTHER SIMILAR
 MATERIALS THAT MEET THE INTENT OF THIS CODE.
  
 C101.5.1.1 ALTERATIONS, RENOVATIONS AND BUILDING
 SYSTEMS. ALTERATIONS, RENOVATIONS AND BUILDING SYSTEMS
 MAY UTILIZE FORM C402. FORM C402 CAN BE FOUND IN
 APPENDIX C.
  
  
 C401.2 APPLICATION. COMMERCIAL BUILDINGS SHALL COMPLY
 WITH ONE OF THE FOLLOWING:
 C401.2.1 APPLICATION TO EXISTING BUILDINGS.
 ADDITIONS, ALTERATIONS AND REPAIRS TO EXISTING
 BUILDINGS SHALL COMPLY WITH ONE OF THE FOLLOWING:
 1. SECTIONS C402, C403, C404 AND C405; OR
 2. ANSI/ASHRAE/IESNA 90.1.
  
 7) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2016-04-15 Cont ID  
Sent By vperez Date 2016-04-15 Time 07:06 Rev Time 0.00
Received By vperez Date 2016-04-15 Time 07:06 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2016-02-16 Cont ID  
Sent By rlecky Date 2016-02-16 Time 13:50 Rev Time 0.00
Received By rlecky Date 2016-02-16 Time 11:41 Sent To  
Notes
2016-02-16 14:00:08PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING
 ELECTRICAL REVIEW COMMENTS.
  
 ELECTRICAL SERVICE AND WIRE SIZES DO NOT CORRESPOND TO
 THE OVERCURRENT PROTECTION PROVIDED AT THE PANELS. THE
 MAXIMUM LOAD ON A 1/0 CONDUCTOR IS 150 AMPERES. PLANS
 SHOW PANELS WITH 200 AMPERE MAIN BREAKERS BUT A SERVICE
 DISCONNECT OF 100 AMPERES. PLEASE CLARIFY. NEC 215.5
  
 CLARIFY IF THE NEW SERVICE WILL BE PART OF THE EXISTING
 OVERHEAD SERICE OR A NEW UNDERGROUND SERVICE AS
 INDICATED ON THE PLANS. NEC 215.5
  
 FEEDERS TO THE PANELBOARDS SHOWN ARE 2 WIRE SINGLE
 PHASE BUT THE PANEL DIRECTORY SUGGESTS THREE PHASE
 PANELS ARE PROPOSED. LOADS HAVE NOT BEEN BALANCED.
 PLEASE CLARIFY. NEC 215.5
  
 NEUTRAL FEEDER SHOWN ARE NOT FULL SIZE. PROVIDE AN
 CALCULATION FOR THE UNBALANCED PORTION OF THE
 ELECTRICAL LOAD WHICH THE NEUTAL FEEDERS WILL CARRY.
 NEC 220.61
  
 INDICATE THE FAULT CURRENT CAPACITY REQUIRED FOR THE
 ELECTRIC SERVICE AND ELECTRIC PANELS. NEC 110.9, 110.10
  
 PROVIDE A SAFETY LABELING SCHEDULE FOR FLASH PROTECTION
 FOR THE SERVICE, PANEL BOARDS AND MAIN DISCONNECTING
 MEANS. NEC 110.16, 110.22
  
 PROVIDE A DIMENSIONED DETAIL FOR THE ELECTRIC EQUIPMENT
 SHOWING THE LOCATION AND ALL SAFETY CLEARANCES WITH
 ADEQUATE HEAD ROOM. NEC 110.26
  
 PROVIDE A 20 AMPERE DEDICATED SIGN CIRCUIT. NEC 600.5
  
 PROVIDE A INTERSYSTEM BONDING BAR AT THE ELECTRICAL
 SERVICE. NEC 250.94
  
 THE GROUNDING ELECTRODE WITH A RIDGIT CONDUIT SLEEVE
 REQUIRES BONDING AT BOTH ENDS. NEC250.64(E)
  
 PROVIDE LIGHTING CONTROLS FOR ENERGY CONSERVATION SO
 THAT THE INTERIOR AND EXTERIOR LIGHTING CONTROLS
 PROVIDED FUNCTION IN ACCORDANCE WITH THE FLORIDA ENERGY
 CODE. EXTERIOR AUTOMATIC CONTROLS SHALL BE CAPABLE OF
 RETAINING PROGRAMMING AND THE TIME SETTING DURING LOSS
 OF POWER FOR A PERIOD OF AT LEAST 10 HOURS. FBC ENERGY
 CONSERVATION C405.2
  
 PROVIDE A LIGHTING DENSITY SUMMARY ON THE ELECTRIC PLAN
 WHICH SHOWS COMPLIANCE WITH THE FLORIDA BUILDING ENERGY
 CODE REQUIREMENTS. FBC ENERGY CONSERVATION C405.2
  
 ROBERT LECKY
 ELECTRICAL PLANS EXAMINER
 561-373-3701
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2015-11-17 Cont ID  
Sent By ppetty Date 2015-11-17 Time 12:50 Rev Time 0.00
Received By ppetty Date 2015-11-17 Time 12:35 Sent To  
Notes
2015-11-17 12:50:06RISER HAS 1 METER PLAN 2
 2 POLE W/H BREAKER

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2016-07-18 Cont ID  
Sent By pleduc Date 2016-07-18 Time   Rev Time 0.00
Received By pleduc Date 2016-07-15 Time 16:45 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2016-01-29 Cont ID  
Sent By pleduc Date 2016-01-29 Time   Rev Time 0.00
Received By pleduc Date 2016-01-29 Time 13:58 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2015-11-04 Cont ID  
Sent By wjolin Date 2015-11-04 Time 09:46 Rev Time 0.00
Received By wjolin Date 2015-11-04 Time 09:09 Sent To  
Notes
2015-11-04 09:21:57831 BELVEDERE ROAD
 PERMIT #15100707
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 THE SMALLER STORAGE ROOM ON THE EAST SIDE OF THE
 BUILDING HAS AN NON-FIRE RATED OVERHEAD DOOR LOCATED
 WITHIN 10 FEET OF THE BUSINESS OCCUPANCY EXIT DOOR. PER
 SECTION 8.7, ANY AREA (STORAGE) HAVING A DEGREE OF
 HAZARD GREATER THAN NORMAL TO THE GENERAL OCCUPANCY
 (BUSINESS) OF THE BUILDING, SHALL BE SEPARATED FROM
 ADJACENT AREAS WITH A 1-HOUR FIRE-RATED BARRIER OR BE
 PROTECTED WITH AN AUTOMATIC SPRINKLER SYSTEM. DOORS
 SHALL BE SELF CLOSING, POSITIVE LATCHING, AND
 FIRE-RATED FOR AT LEAST 45-MINUTES.
  
 PLANS DO NOT INDICATE ANY EXISTING LIGHTING OR PORTABLE
 FIRE EXTINGUISHERS IN THE SMALL STORAGE ROOM ON THE
 EAST SIDE OF THE BUILDING.
  
 PER SECTION 8.3.2.4, EACH FIRE BARRIER SHALL BE
 PERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING READING
 FIRE BARRIER-PROTECT ALL OPENINGS. CHARACTERS SHALL BE
 AT LEAST 4-INCHES IN HEIGHT AND HALF-INCH IN WIDTH.
 IDENTIFICATION SHALL BE SPACED NOT MORE THAN 15 FEET ON
 CENTER.
  
 PER SECTION 8.3.5.1, PENETRATIONS THROUGH A FIRE-RATED
 WALL ASSEMBLY SHALL BE PROTECTED BY A FIRESTOP SYSTEM
 OR DEVICE.
  
 WESLEY JOLIN
 ASSISTANT FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 805-6730
  

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2016-07-29 Cont ID  
Sent By   Date 2016-07-29 Time 06:30 Rev Time 0.00
Received By lmarchan Date 2016-07-08 Time 11:51 Sent To  
Notes
2016-07-11 11:51:59C24

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2016-06-20 Cont ID  
Sent By jwitmer Date 2016-06-20 Time 10:21 Rev Time 0.00
Received By jwitmer Date 2016-06-07 Time 10:06 Sent To  
Notes
2016-06-08 10:07:01CCOLE'S DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2016-06-08 Cont ID  
Sent By cpuell Date 2016-06-08 Time 10:03 Rev Time 0.00
Received By cpuell Date 2016-04-12 Time 15:49 Sent To  
Notes
2016-04-12 15:49:09C03

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-02-16 Cont ID  
Sent By rlecky Date 2016-02-16 Time 14:00 Rev Time 0.00
Received By rlecky Date 2016-01-12 Time 10:45 Sent To  
Notes
2016-01-12 10:52:55C01

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-11-22 Cont ID  
Sent By cpuell Date 2015-11-22 Time 11:13 Rev Time 0.00
Received By cpuell Date 2015-10-20 Time 14:07 Sent To  
Notes
2015-10-20 14:08:05C21

Review Stop M MECHANICAL (A/C)
Rev No 5 Status P Date 2016-07-15 Cont ID  
Sent By ccole Date 2016-07-15 Time 07:52 Rev Time 0.00
Received By ccole Date 2016-07-14 Time 17:32 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 4 Status F Date 2016-07-15 Cont ID  
Sent By ccole Date 2016-06-09 Time 17:32 Rev Time 0.00
Received By ccole Date 2016-06-09 Time 15:57 Sent To  
Notes
2016-06-09 16:13:543RD REVIEW: FBC 2014 MECHANICAL
 PERMIT #15100707
 6/9/16
  
 1) I AM NOT AGREEING WITH THE 81 DEGREE COOLING DESIGN
 TEMPERATURE FOR WEST PALM BEACH AS SHOWN ON THE AC LOAD
 CALCULATIONS. AS PREVIOUSLY NOTED, TABLE 1A OF ACCA
 MANUAL N LISTS THE COOLING DRYBULB TEMP FOR WPB AT 90
 DEGREES. PLEASE ADJUST THE CALCULATIONS OR SUBMIT THE
 DESIGN WITH AS AN ALTERNATEMETHOD ACCOMPANIED BY A
 SIGNED AND SEALED LETTER FROM THE EOR.
  
 2) BASED ON THE DRAWING, THE FRONT DOOR OF THE BUILDING
 APPEARS TO BE FACING EAST, HOWEVER THE AC CALCULATIONS
 ARE INDICATING NORTH
  
 3) PLEASE REVIEW AND REVISE THE ENERGY GAUGE COMPLIANCE
 CHECKLIST- SOME OF THE BOXES CHECKED "YES" DO NOT
 APPEAR APPLICABLE TO THIS PROJECT.
  
 4) SHEET A3 INDICATES A WOOD DOOR ACCESS DOOR TO THE AC
 CLOSET IN OFFICE 2. AS PREVIOSULY NOTED, A
 NON-COMBUSTIBLE DOOR IS REQUIRED PER SECTION C403.2.7.2
 FBC-14 ENERGY CONSERVATION.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2016-07-15 Cont ID  
Sent By ccole Date 2016-04-15 Time 15:41 Rev Time 0.00
Received By ccole Date 2016-04-15 Time 15:41 Sent To  
Notes
2016-04-15 16:16:153RD REVIEW: FBC 2014 MECHANICAL
 PERMIT #15100707
 3RD MECHANICAL REVIEW
  
 1) THE SUBMITTED AC CALCULATIONS ARE BASED ON AN
 INCORRECT DRY BULB TEMPERATURE OF 81 DEGREEES FOR WEST
 PALM BEACH. DRY BULB TEMPERATURE PER ACCA MANUAL N IS
 91 DEGREES.
 2) THE AC CALCS ARE BASED ON THE FRONT DOOR FACING
 NORTH, HOWEVER THE FRONT DOOR FOR THE NEW OCCUPANCY
 APPEARS TO BE FACING SOUTHEAST.
 3) PLEASE COMPLETE THE MANDATORY REQUIREMENTS CHECKLIST
 ON PAGE 7 OF THE ENERGY EFFICIENCY SUBMITTAL, AND
 SUBMIT THE INPUT DATA REPORT AS NOTED ON PAGE 1.
 4) THE WIND LOAD DESIGN CRITERIA ON SHEET M1 IS
 INCOMPLETE: PROVIDE THE BASIC WIND SPEED, EXPOSURE
 CATEGORY, AND IMPORTANCE FACTOR PER SECTION 1609 FBC-14
 BUILDING. PLEASE NOTE THE NOA #98-126.01 IS NOT A VALID
 NOA NUMBER. PLEASE PROVIDE THE CORRECT NUMBER ON THE
 PLAN AND TWO COPIES OF THE DOCUMENT REVIEWED AND
 APPROVED WITH SIGNATURE BY THE EOR.
 5) SHEET A3 INDICATES A WOOD-LOUVERED AC CLOSET DOOR,
 AND M1 INDICATES A RETRURN AIR GRILL IONTO THE CLOSET
 WITH NO DOORS. PLEASE NOTE THAT IF A LOUVERED DOOR IS
 TO BE USED IT MUST BE NON-COMBUSTIBLE- SECTIONS
 C403.2.7.2 & C403.2.7.3 FBC-ENERGY CONSERVATION.
 6) M1: THE CORRIDOR CANNOT BE USED AS A RETURN DUCT PER
 SECTION 601.2. PLEASE REMOVE THE TRANSFER AND PROVIDE A
 DUCTED RETRUN.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2016-01-14 Cont ID  
Sent By ccole Date 2016-01-14 Time 15:57 Rev Time 0.00
Received By ccole Date 2016-01-14 Time 15:57 Sent To  
Notes
2016-01-14 16:01:562ND REVIEW: FBC 2014 MECHANICAL
 PERMIT #15100707
 01/14/16
  
 COMMENTS #1, 2, AND 4 FROM THE 1ST REVIEW STILL EXIST.
 I AM HAVE ATTACHED THEM BELOW. PLEASE NOTE THAT THE M-1
 MECHANICAL SHEETS WERE NOT INSERTED INTO THE REVISED
 PLAN SETS- PLEASE ADD THE REQUIRED SHEETS.
 1) THE PROPOSED PROJECT IS CLASSIFIED AS A RENOVATED
 BUILDING IN ACCORDANCE WITH SECTION C202 FBC-14 ENERGY
 CONSERVATION, AND THEREFORE SHALL BE IN COMPLIANCE WITH
 THE CURRENT CODE PER SECTION C101.4.3. PLEASE SUBMIT
 TWO COPIES OF COMPLIANCE DOCUMENTATION USING EITHER THE
 PRESCRIPTIVE OR PERFORMANCE BASED COMPLIANCE PATH AS
 OUTLINED IN SECTION C101.5.1.
 (PLEASE NOTE THAT THE NARRATIVE RESPONSE IS INDICATING
 A PREVIOUSLY CONDITIONED BUILDING, HOWEVER THIS IS NOT
 THE ISSUE).
 2) REFER TO SECTION C403.2.1 AND SUBMIT COOLING AND
 HEATING CALCULATIONS FOR THE NEW 3-TON AC SYSTEM IN
 ACCORDANCE WITH THE PROCEDURES DESRIBED IN THE
 ASHRAE/ACCA STANDARD 183 OR ACCA MANUAL N.
 ( PLEASE NOTE THE NARRATIVE RESPONSE INDICATES THE
 CALCULATIONS HAVE BEEN PROVIDED BUT THEY WERE NOT
 SUBMITTED).
 4) SITE SPECIFIC WINDLOAD ENGINEERING IS REQUIRED FOR
 ROOFTOP AC UNITS IN COMPLIANCE WITH SECTION 301.15. THE
 ENGINEER OF RECORD MUST PROVIDE THE WIND LOAD DESIGN
 CRITERIA AND DESIGN PRESSURES ON THE PLAN, AND SUBMIT
 REVIEWED AND APPROVED NOA'S OR PRODUCT APPROVALS FOR
 THE ROOF STAND AND CLIPS.
 (PLEASE NOTE THAT THE NOA WAS SUBMITTED HOWEVER THE
 REQUESTED WIND DESIGN CRITERIA WAS NOT INDICATED ON THE
 PLANS AS REQUESTED).
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2015-11-03 Cont ID  
Sent By ccole Date 2015-11-03 Time 14:19 Rev Time 0.00
Received By ccole Date 2015-11-03 Time 14:19 Sent To  
Notes
2015-11-03 15:53:321ST REVIEW: FBC 2014 MECHANICAL
 PERMIT #15100707
 11/3/15
  
 1) THE PROPOSED PROJECT IS CLASSIFIED AS A RENOVATED
 BUILDING IN ACCORDANCE WITH SECTION C202 FBC-14 ENERGY
 CONSERVATION, AND THEREFORE SHALL BE IN COMPLIANCE WITH
 THE CURRENT CODE PER SECTION C101.4.3. PLEASE SUBMIT
 TWO COPIES OF COMPLIANCE DOCUMENTATION USING EITHER THE
 PRESCRIPTIVE OR PERFORMANCE BASED COMPLIANCE PATH AS
 OUTLINED IN SECTION C101.5.1.
 2) REFER TO SECTION C403.2.1 AND SUBMIT COOLING AND
 HEATING CALCULATIONS FOR THE NEW 3-TON AC SYSTEM IN
 ACCORDANCE WITH THE PROCEDURES DESRIBED IN THE
 ASHRAE/ACCA STANDARD 183 OR ACCA MANUAL N.
 3) THE CORRIDOR CANNOT BE USED TO CONVEY RETURN AIR
 FROM THE OFFICES PER SECTION 601.2 FBC-14 MECHANICAL.
 4) SITE SPECIFIC WINDLOAD ENGINEERING IS REQUIRED FOR
 ROOFTOP AC UNITS IN COMPLIANCE WITH SECTION 301.15. THE
 ENGINEER OF RECORD MUST PROVIDE THE WIND LOAD DESIGN
 CRITERIA AND DESIGN PRESSURES ON THE PLAN, AND SUBMIT
 REVIEWED AND APPROVED NOA'S OR PRODUCT APPROVALS FOR
 THE ROOF STAND AND CLIPS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2016-01-16 Cont ID  
Sent By tklarge Date 2016-01-16 Time 09:42 Rev Time 0.00
Received By tklarge Date 2016-01-16 Time 09:30 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2015-10-23 Cont ID  
Sent By gjohnson Date 2015-10-23 Time 18:03 Rev Time 0.00
Received By gjohnson Date 2015-10-23 Time 18:03 Sent To  
Notes
2015-10-23 18:19:561ST REVIEW: FBC 2014
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  
 PLUMBING COMMENTS:
  
  
  
 1.SHOW CLEAR FLOOR SPACE FOR KITCHEN SINK AND SHOW
 HIGHT.MUST COPLY WITH FBCACC SEC 305.2 AND 305.3 AND
 305.4 AND 606.2 606.3
 2.PROVIDE A RISER DIGRAM THAT SHOWS HOT WATER YOU SHOW
 A TANKLESS HEATER BUT NO WATER PIPING PER WPB AMEND. TO
 FBC SEC 107.3.5.1.3(13)
 FBCP SEC
 SECTION 607 HOT WATER SUPPLY SYSTEM
  
 607.1 WHERE REQUIRED.
 IN RESIDENTIAL OCCUPANCIES, HOT WATER SHALL BE SUPPLIED
 TO PLUMBING FIXTURES AND EQUIPMENT UTILIZED FOR
 BATHING, WASHING, CULINARY PURPOSES, CLEANSING, LAUNDRY
 OR BUILDING MAINTENANCE. IN NONRESIDENTIAL
 OCCUPANCIES,HOT WATER SHALL BE SUPPLIED FOR CULINARY
 PURPOSES, CLEANSING, LAUNDRY OR BUILDING MAINTENANCE
 PURPOSES. IN NONRESIDENTIAL OCCUPANCIES, HOT WATER OR
 TEMPERED WATER SHALL BE SUPPLIED FOR BATHING AND
 WASHING PURPOSES.
  

Review Stop Z ZONING
Rev No 2 Status P Date 2016-02-01 Cont ID  
Sent By sgraham Date 2016-02-01 Time 12:00 Rev Time 0.00
Received By sgraham Date 2016-02-01 Time 12:00 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2015-10-29 Cont ID  
Sent By sgraham Date 2015-10-29 Time 08:45 Rev Time 0.00
Received By sgraham Date 2015-10-29 Time 08:45 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved