| Plan Review Stops For Permit 15100682 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2016-01-28 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-01-28 |
Time |
08:10 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-01-28 |
Time |
07:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2016-01-11 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-01-11 |
Time |
16:50 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-01-11 |
Time |
11:43 |
Sent To |
|
|
| Notes |
| 2016-01-11 16:50:38 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 15100682 | | | ADD: 5827 CORPORATE WAY | | | CONT: SHIFF | | | TEL: (954)524-2575 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: MON. JAN. 08/2016 | | | ACTION: DENIED | | | | | | 1-5) COMPLIED. | | | | | | 6) 2ND REQUEST. RESPONSE INDICATES PLEASE SEE ENCLOSED | | | FIRE ALARM SHOP DRAWINGS. THE COVERSHEET A-0.0 | | | INDICATES THE OCCUPANT LOAD OF ON BOTH THE 1ST FLOOR | | | AND 2ND FLOOR AS 90+ WHEREAS THE SQUARE FOOTAGE IS | | | 10,040 SQ. FT./ 100= 101 OCCUPANTS. THE 2014 EXISTING | | | BUILDING CODE 904.2.1 WILL REFER YOU FOR A MANUAL FIRE | | | ALARM TO THE FBC-BUILDING 907.2.2 SINCE THE BUSINESS | | | OCCUPANCY ON THE 2 ND FLOOR IS OVER 100 IN GROUP B | | | OCCUPANCY. | | | | | | 7) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-11-03 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-11-03 |
Time |
12:31 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-11-03 |
Time |
07:00 |
Sent To |
|
|
| Notes |
| 2015-11-03 12:31:13 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 15100682 | | | ADD: 5827 CORPORATE WAY | | | CONT: SHIFF | | | TEL: (954)524-2575 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: MON. JAN. 08/2016 | | | ACTION: DENIED | | | | | | 1-5) COMPLIED. | | | | | | 6) 2ND REQUEST. RESPONSE INDICATES PLEASE SEE ENCLOSED | | | FIRE ALARM SHOP DRAWINGS. THE COVERSHEET A-0.0 | | | INDICATES THE OCCUPANT LOAD OF ON BOTH THE 1ST FLOOR | | | AND 2ND FLOOR AS 90+ WHEREAS THE SQUARE FOOTAGE IS | | | 10,040 SQ. FT./ 100= 101 OCCUPANTS. THE 2014 EXISTING | | | BUILDING CODE 904.2.1 WILL REFER YOU FOR A MANUAL FIRE | | | ALARM TO THE FBC-BUILDING 907.2.2 SINCE THE BUSINESS | | | OCCUPANCY ON THE 2 ND FLOOR IS OVER 100 IN GROUP B | | | OCCUPANCY. | | | | | | 7) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2016-02-05 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2016-02-05 |
Time |
09:22 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2016-02-05 |
Time |
08:50 |
Sent To |
I |
|
| Notes |
| 2016-02-05 09:23:04 | ALL PREVIOUSLY MENTIONED DEFICIENCIES HAVE BEEN | | | SATISFACTORILY ADDRESSED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2016-01-14 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2016-01-14 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2016-01-13 |
Time |
17:02 |
Sent To |
I |
|
| Notes |
| 2016-01-14 09:02:54 | YOUR RESUBMITTAL ADDRESSING THE PREVIOUSLY MENTIONED | | | DEFICIENCIES HAS ONCE AGAIN FAILED THE ELECTRICAL | | | REVIEW AS INDICATED BELOW. NEW COMMENTS IF ANY PROMPTED | | | BY ANOTHER REVIEW, MOST LIKELY DUE TO YOUR FAILURE TO | | | SUBMIT A RESPONSE LETTER (NARRATIVE) ADDRESSING THE | | | REQUIRED CORRECTIONS WILL BE NUMBERED IN CONTINUATION | | | OF ANY PREVIOUS COMMENTS. | | | ALL OF THE PREVIOUSLY MENTIONED DEFICIENCIES HAVE BEEN | | | SATISFACTORILY ADDRESSED EXCEPT THE ONE MENTIONED | | | BELOW. | | | COMMENT #2: NEC 215.5 REQUIRES A FEEDER DIAGRAM WITH | | | LOAD CALCS AND CONDUCTOR SIZING. THE FEEDER DIAGRAM | | | PROVIDED FAILS TO INCLUDE ALL THE PANELS INCLUDED | | | WITHIN THE AREA OF THE SCOPE OF WORK. | | | | | | PLEASE REVISE YOUR DRAWINGS TO REFLECT THE ABOVE | | | MENTIONED DEFICIENCIES. | | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | | RE-SUBMITTAL, YOU ARE REQUIRED TO PROVIDE A RESPONSE | | | LETTER (NARRATIVE) ADDRESSING EACH ITEM ALONG WITH THE | | | STANDARD CITY RE-SUBMITTAL FORM. THE NARRATIVE SHOULD | | | INCLUDE THE PLAN REVIEWER?S COMMENTS AND YOUR RESPONSE | | | OR ACTION TO SAME. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PAGES INTO THE SUBMITTAL AND LEAVE THE | | | PREVIOUSLY REVIEWED SHEETS FOR COMPARISON. | | | CLOUDING THE CHANGES WILL BE GREATLY APPRECIATED. | | | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON'T HESITATE TO | | | CONTACT ME DIRECTLY. | | | THANK YOU, | | | MIKE ALBARRAN | | | ELECTRICAL PLANS EXAMINER | | | PH: 561-805-6746 | | | EMAIL: [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2015-11-19 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-11-19 |
Time |
15:36 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-11-19 |
Time |
13:24 |
Sent To |
I |
|
| Notes |
| 2015-11-19 15:36:55 | THE PLANS FOR THE ABOVE MENTIONED PERMIT APPLICATION | | | HAVE BEEN REVIEWED FOR COMPLIANCE WITH THE EDITION OF | | | THE NEC, (NATIONAL ELECTRICAL CODE) AND THE FBC, | | | (FLORIDA BUILDING CODE) AS WELL AS THE CITY OF WEST | | | PALM BEACH AMENDMENTS IN EFFECT AT THE TIME OF | | | SUBMITTAL. BELOW IS A LIST OF THE DEFICIENCIES NOTED. | | | 1. DUE TO THE CONFLICT BETWEEN NEW & EXISTING | | | LUMINAIRES IT IS IMPRACTICAL TO DETERMINE FROM THE | | | SUBMITTED DRAWINGS THE ACTUAL LOCATION OF EMERGENCY AND | | | EXIT LIGHTING. THEREFORE, IT WILL BE UP TO THE FIELD | | | INSPECTOR TO DETERMINE COMPLIANCE. | | | 2. NEC 215.5 REQUIRES A FEEDER DIAGRAM WITH LOAD CALCS | | | AND CONDUCTOR SIZING. THE FEEDER DIAGRAM PROVIDED FAILS | | | TO INCLUDE ALL THE PANELS INCLUDED WITHIN THE AREA OF | | | THE SCOPE OF WORK. | | | 3. NEC 408.4(B) REQUIRES THAT ALL PANELS BE MARKED TO | | | INDICATED THE LOCATION OF THEIR SOURCE OF POWER AND | | | DISCONNECT. | | | 4. NEC 410.30 REQUIRES THAT LUMINARIES WEIGHING GREATER | | | THAN 6 LBS OR EXCEED 16 IN. BE SUPPORTED BY OTHER THAN | | | THE OUTLET BOX. | | | 5. NEC 410.36(B) REQUIRES THAT LUMINAIRES IN SUSPENDED | | | CEILINGS BE SECURELY FASTENED TO THE CEILING MEMBERS BY | | | MECHANICAL MEANS. | | | 6. FBC-E SECTION C402.4.8 STATES THAT ALL RECESSED | | | LIGHTING INSTALLED IN THE BUILDING?S THERMAL ENVELOPE | | | BE IC RATED AND BE SEALED TO LIMIT THE LEAKAGE OF AIR | | | BETWEEN THE CONDITIONED AND NON-CONDITIONED SPACE. | | | PLEASE REVISE YOUR DRAWINGS TO REFLECT THE ABOVE | | | MENTIONED DEFICIENCIES. | | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | | RE-SUBMITTAL, YOU ARE REQUIRED TO PROVIDE A RESPONSE | | | LETTER (NARRATIVE) ADDRESSING EACH ITEM ALONG WITH THE | | | STANDARD CITY RE-SUBMITTAL FORM. THE NARRATIVE SHOULD | | | INCLUDE THE PLAN REVIEWER?S COMMENTS AND YOUR RESPONSE | | | OR ACTION TO SAME. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PAGES INTO THE SUBMITTAL AND LEAVE THE | | | PREVIOUSLY REVIEWED SHEETS FOR COMPARISON. | | | CLOUDING THE CHANGES WILL BE GREATLY APPRECIATED. | | | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | | CONTACT ME DIRECTLY. | | | | | | THANK YOU, | | | MIKE ALBARRAN | | | ELECTRICAL PLANS EXAMINER | | | PH: 561-805-6746 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2016-01-07 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2016-01-07 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2016-01-07 |
Time |
15:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2015-10-29 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2015-10-29 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2015-10-29 |
Time |
09:20 |
Sent To |
|
|
| Notes |
| 2015-10-29 09:54:53 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | 1. SHEET A 0.0, INDICATES AN INCORRECT REFERENCE TO THE | | | FIRE CODE, | | | | | | THE PROPOSED PROJECT SHALL MEET THE REQUIREMENTS OF THE | | | 5TH EDITION OF FLORIDA FIRE PREVENTION CODE INCLUDING | | | THE 2012 EDITION OF NFPA 1 AND NFPA 101 AND ALL OTHER | | | APPLICABLE CODES OR STANDARDS. | | | FIRE SPRINKLER WORK SHALL COMPLY WITH THE REQUIREMENTS | | | OF NFPA 13, 2010 EDITION. | | | FIRE ALARM WORK SHALL COMPLY WITH THE REQUIREMENTS OF | | | NFPA 72, 2010 EDITION. | | | CONSTRUCTION WORK SHALL COMPLY WITH THE REQUIREMENTS OF | | | NFPA 241, 2009 EDITION. | | | FIRE EXTINGUISHERS SHALL COMPLY WITH THE REQUIREMENTS | | | OF NFPA 10, 2010 EDITION. | | | | | | 2. SHEET E 1, DOES NOT INDICATE AN EXIT SIGN AT THE NEW | | | DOOR FROM THE CORRIDOR TO THE IT ROOM. INSTALL AN EXIT | | | SIGN INSIDE THE CORRIDOR AT THE IT ROOM DOOR. | | | | | | 3. THE NATURE OF THE REMODEL REQUIRES AN EVALUATION OF | | | ANY FIRE ALARM SYSTEM EQUIPMENT FOR CODE COVERAGE AND | | | COMPLIANCE. ANY REMOVAL AND/OR CONSTRUCTION OF WALLS | | | REQUIRE AN EVALUATION OF THE EXISTING EQUIPMENT. | | | IF EXISTING, THE FIRE ALARM SYSTEM SHALL REMAIN ACTIVE | | | THROUGHOUT THE CONSTRUCTION PERIOD. | | | ANY AND ALL WORK ON THE FIRE ALARM SYSTEM SHALL BE DONE | | | UNDER SEPARATE SHOP DRAWINGS AND BY CERTIFIED LIFE | | | SAFETY CONTRACTORS. | | | ANY TIME THAT WORK ON THE LIFE SAFETY SYSTEM, EXCEEDS 4 | | | HOURS, A FIRE WATCH SHALL BE IMPLEMENTED AND MAINTAINED | | | UNTIL FULL AND COMPLETE PROTECTION IS RETURNED. | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2016-02-05 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2016-02-05 |
Time |
09:25 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2016-01-20 |
Time |
13:49 |
Sent To |
|
|
| Notes |
| 2016-02-05 09:26:43 | 2/5/16 PASSED THE LAST OF ALL TRADE REVIEWS AND IS | | | READY FOR ISSUANCE. CONTRACTOR NOTIFIED VIA EMAIL. SENT | | | FILE TO LARGE READY BIN "S". MA | | 2016-01-21 13:50:05 | C27 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-01-14 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2016-01-14 |
Time |
09:09 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-12-29 |
Time |
11:07 |
Sent To |
|
|
| Notes |
| 2016-01-14 09:10:38 | 1/14/16 FAILED THE LAST OF THE TRADE REVIEWS. DESIGN | | | PROFESSIONAL ADVISED VIA EMAIL. SENT TO LARGE DENIED | | | BIN "S". MA | | 2016-01-04 13:21:18 | C34 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-11-19 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-11-19 |
Time |
15:39 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-10-20 |
Time |
12:53 |
Sent To |
|
|
| Notes |
| 2015-11-19 15:38:59 | 11/19/15 FAILED THE ELECTRICAL REVIEW AS NOTED. | | | CONTRACTOR NOTIFIED VIA EMAIL. SENT TO LARGE DENIED BIN | | | "S". MA | | 2015-10-20 12:53:27 | B25 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2016-01-04 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2016-01-04 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-12-29 |
Time |
10:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2016-01-29 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-01-29 |
Time |
07:18 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-01-29 |
Time |
07:18 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2016-01-05 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-01-05 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-01-05 |
Time |
10:11 |
Sent To |
|
|
| Notes |
| 2016-01-05 10:15:25 | 2ND REVIEW: FBC 2014 MECHANICAL | | | PERMIT #15100682 | | | 01/05/16 | | | | | | 1) SHEET M-1: THE LOCATION OF THE OUTDOOR AIR INTAKE ON | | | THE WEST SIDE OF THE FIRST FLOOR APPEARS TO BE NOT IN | | | COMPLIANCE WITH SECTION 401.4 ITEM #2 WHIC REQUIRES A | | | 10' CLEARANCE TO THE PARKING LOT OR DRIVE LANE. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2015-11-04 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-11-04 |
Time |
07:40 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-11-04 |
Time |
10:32 |
Sent To |
|
|
| Notes |
| 2015-11-04 08:08:32 | 1ST REVIEW: FBC 2014 MECHANICAL | | | PERMIT #15100682 | | | 11/4/2015 | | | | | | 1) SHEET D-2.0: THE DEMO NOTES SHOWN ON THE 2ND FLOOR | | | RCP DO NOT MAKE SENSE WITH THE DRAWING: PLEASE REVISE. | | | 2) M-1: THE PLANS ARE VERY VAGUE AND SHOW ONLY TWO DUCT | | | RELOCATIONS IN THE EXPANDED IT ROOM. PLEASE SHOW ALL | | | RELOCATED DUCTS, DIIFFUSERS, AND RETURN GRILLS ON THE | | | PLAN BASED ON THE NEW CEILING AND LIGHTING LAYOUTS, | | | INCLUDING THE WAREHOUSE WHERE THE SUSPENDED CEILING | | | WILL BE REMOVED ENTIRELY. | | | 3) PROVIDE AN AIR DEVICE SCHEDULE. | | | 4) REFER TO SECTION 809.2 FBC-14 EXISTING BUIILDING | | | CODE- ALTERED EXISTING SYSTEMS. | | | IN MECHANICALLY VENTILATED SPACES, EXISTING MECHANICAL | | | VENTILATION SYSTEMS THAT ARE ALTERED, RECONFIGURED, OR | | | EXTENDED SHALL PROVIDE NOT LESS THAN 5 CUBIC FEET PER | | | MINUTE (CFM) (0.0024 M3/S) PER PERSON OF OUTDOOR AIR | | | AND NOT LESS THAN 15 CFM (0.0071 M3/S) OF VENTILATION | | | AIR PER PERSON; OR NOT LESS THAN THE AMOUNT OF | | | VENTILATION AIR DETERMINED BY THE INDOOR AIR QUALITY | | | PROCEDURE OF ASHRAE 62. PLEASE PROVIDE CALCULATIONS ON | | | THE PLAN TO INDICATE COMPLIANCE. | | | 5) PROVIDE ENERGY CALCULATIONS IN COMPLIANCE WITH | | | SECTION C101.4.3 FBC-14 ENERGY CONSERVATION. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2016-01-08 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-01-08 |
Time |
15:21 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-01-08 |
Time |
15:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2015-10-23 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2015-10-23 |
Time |
17:22 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2015-10-23 |
Time |
17:22 |
Sent To |
|
|
| Notes |
| 2015-10-23 17:29:22 | 1ST REVIEW: FBC 2014 | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | | | | 1.SHEET A-2.2 IT APPEARS THAT YOU ARE ELIMINATING | | | RESTROOM 208 AND LEAVING 209 AN ACCESSIBLE BATHROOM CAN | | | NOT BE ACCESSED THROUGH A PRIVATE OFFICE. |
|
|