Plan Review Details - Permit 15100678
Plan Review Stops For Permit 15100678
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-01-12 Cont ID  
Sent By jwitmer Date 2016-01-12 Time 05:58 Rev Time 0.00
Received By jwitmer Date 2016-01-11 Time 15:33 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-11-03 Cont ID  
Sent By jwitmer Date 2015-11-03 Time 16:25 Rev Time  
Received By jwitmer Date 2015-11-03 Time 07:30 Sent To  
Notes
2015-11-03 09:50:16 
  
  
  
  
 BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15100678
 ADD: 5817 CORPORATE WAY
 CONT: ALL AMERICAN WINDOWS
 TEL: (954)786-8625
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. NOV. 03/2014
 ACTION: DENIED
  
 1) ENGINEERING WIND LOADS FOR COMPONENTS AND CLADDING
 SHEET SIGNED AND SEALED BY JAVAD AHMAD P. E.
 IS FOR A EXPOSURE ?D? AND A ROOF SLOPE> 10 DEGREES.
 PLEASE SUBMIT THE CORRECT WIND DESIGN CRITERIA FOR THIS
 JOB. THE JOB IS A EXPOSURE ?C? WIND ZONE 170 VULT, 3
 SECOND GUST AND A FLAT ROOF. PRESSURES WILL GO UP ON
 THE FLAT ROOF COMPARED TO A ROOF WITH A ROOF SLOPE OF >
 THAN 10 DEGREES. 2014 FBC-B 1603.1.4 WIND DESIGN
 CRITERIA.
  
 2) SHEET A-2.4 & A-2.5 ARE CONTRACTOR PREPARED
 DRAWINGS. F. S. 471.003?QUALIFICATIONS FOR PRACTICE;
 EXEMPTIONS.? (1)?NO PERSON OTHER THAN A DULY LICENSED
 ENGINEER SHALL PRACTICE ENGINEERING OR USE THE NAME OR
 TITLE OF ?LICENSED ENGINEER,? ?PROFESSIONAL ENGINEER,?
 OR ANY OTHER TITLE, DESIGNATION, WORDS, LETTERS,
 ABBREVIATIONS, OR DEVICE TENDING TO INDICATE THAT SUCH
 PERSON HOLDS AN ACTIVE LICENSE AS AN ENGINEER IN THIS
 STATE.
  
 3) PRODUCT APPROVAL REVIEW FORM DOES SUBMITTED BY ALL
 AMERICAN WINDOWS AND DOORS DOES NOT LIST THE WIND
 DESIGN CRITERIA AS TO HOW THE PRESSURES WERE DERIVED.
 THE PRESSURES BY JAVAD AHMAD P.E. WILL VARY SINCE THE
 WRONG DESIGN CRITERIA WAS USED.
  
 4) PRODUCT APPROVAL REVIEW FORM DOES SUBMITTED BY ALL
 AMERICAN WINDOWS AND DOORS DOES NOT FOLLOW THE SAME
 DESIGN CRITERIA. ALL AMERICAN IS USING THE OVERALL
 OPENING SIZE WHERE AS THE PRODUCT APPROVAL SUBMITTED
 15-0826.31 PAGE 3 OF 12 SIZES THE OPENINGS WITH THE
 MULLION TRIBUTARY AREA W1+W2/2= TRIBUTARY AREA.
  
 5) NOA 13-0820.12 MR. GLASS DOORS & WINDOW NOA SERIES
 MG-500 ALUMINUM OUTSWING FRENCH DOORS, THERE ARE NO
 SWING DOORS SHOWN ON THE FLOOR PLAN NOR ANY FOUND IN
 THE PRODUCT APPROVAL REVIEW SHEET. 107.2.1.3 ADDITIONAL
 INFORMATION IS REQUIRED.
  
 6) THE 1ST FLOOR, FLOOR PLAN DOES HAVE A DOOR
 IDENTIFIED AS 1W. THE PRODUCT APPROVAL REVIEW SHEET
 ALSO HAS A 1W LISTED IN THE REVIEW FORM AND A NOA
 13-0820.12 MR. GLASS DOORS & WINDOW NOA SERIES MG-500
 ALUMINUM OUTSWING FRENCH DOORS. EITHER THE FRONT ENTRY
 DOORS SHOULD BE DRAWN AS SWING DOORS OR THE WRONG
 APPROVAL WAS SUBMITTED AND IS EITHER HORIZONTAL SLIDING
 DOORS OR POWER-OPERATED DOORS. 107.1.2 ADDITIONAL
 INFORMATION REQUIRED.
 1008.1.4.2 POWER-OPERATED DOORS, OR 1008.1.4.3
 HORIZONTAL SLIDING DOORS. PLEASE SUBMIT DOCUMENTATION
 FOR CODE COMPLIANCE.
  
 7) THE TOTAL PROJECT THE INTERIOR RENOVATION AND
 EXTERIOR GLAZING WILL BE CONSIDERED UNDER THE 2014
 FBC-ENERGY CODE BY DEFINITION A RENOVATION. PLEASE
 REVIEW UNDER THE DEFINITION OF ALTERATION UNDER THE
 2014 FBC-ENERGY CODE. CHAPTER 2 (CE) DEFINITIONS: A
 RESIDENTIAL OR NONRESIDENTIAL BUILDING UNDERGOING
 ALTERATION THAT VARIES OR CHANGES INSULATION, HVAC
 SYSTEMS, WATER HEATING SYSTEMS, OR EXTERIOR ENVELOPE
 CONDITIONS, PROVIDED THE ESTIMATED COST OF RENOVATION
 EXCEEDS 30 PERCENT OF THE ASSESSED VALUE OF THE
 STRUCTURE.
  
 PLEASE SHOW COMPLIANCE WITH THE 2014 FBC-ENERGY CODE
 C401.2.1 APPLICATION TO EXISTING BUILDINGS.
 ADDITIONS, ALTERATIONS AND REPAIRS TO EXISTING
 BUILDINGS SHALL COMPLY WITH ONE OF THE FOLLOWING:
 1. SECTIONS C402, C403, C404 AND C405; OR
 2. ANSI/ASHRAE/IESNA 90.1.
  
 8) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-01-12 Cont ID  
Sent By jwitmer Date 2016-01-12 Time 05:58 Rev Time 0.00
Received By jwitmer Date 2015-11-30 Time 10:05 Sent To  
Notes
2015-12-01 10:05:25RESUB ROUTED TO JWITMER