| Plan Review Stops For Permit 15100627 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2015-12-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2015-12-21 |
Time |
09:48 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2015-12-21 |
Time |
09:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-11-17 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2015-11-17 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2015-11-17 |
Time |
15:53 |
Sent To |
E |
|
| Notes |
| 2015-11-17 16:01:33 | CHRISTOPHER S. THROOP, C.B.O. | | | BLDG. PLANS EXAMINER ? PX3169 | | | (561) 805-6718 | | | [email protected] | | | | | | PROVIDE PRODUCT APPROVAL FOR WINDOW MULLIONS. | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE WINDOW SUBMITTALS. | | | | | | IDENTIFY WALLS TO BE REMOVED - LOAD BEARING/NON-LOAD | | | BEARING. | | | IDENTIFY SUB-FLOORING TO BE INSTALLED AND FASTENER | | | SCHEDULE AT LIVING ROOM. | | | | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN | | | UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE | | | OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE | | | AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT | | | IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | | DETERMINED BY THE BUILDING OFFICIAL. SUCH DRAWINGS AND | | | SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM | | | OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS, | | | WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE | | | TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC, | | | AND THE TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE | | | OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS | | | EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | | INFORMATION. ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | | SECTION 107.3.5). | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2015-12-17 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2015-12-17 |
Time |
14:43 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2015-12-17 |
Time |
14:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2015-11-18 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2015-11-18 |
Time |
08:38 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2015-11-18 |
Time |
09:06 |
Sent To |
|
|
| Notes |
| 2015-11-18 09:17:40 | E3901.2.1 SPACING. | | | RECEPTACLES SHALL BE INSTALLED SO THAT NO POINT | | | MEASURED HORIZONTALLY ALONG THE FLOOR LINE OF ANY WALL | | | SPACE IS MORE THAN 6 FEET (1829 MM), FROM A RECEPTACLE | | | OUTLET. | | | E3901.2 GENERAL PURPOSE RECEPTACLE DISTRIBUTION. | | | IN EVERY KITCHEN, FAMILY ROOM, DINING ROOM, LIVING | | | ROOM, PARLOR, LIBRARY, DEN, SUN ROOM, BEDROOM, | | | RECREATION ROOM, OR SIMILAR ROOM OR AREA OF DWELLING | | | UNITS, RECEPTACLE OUTLETS SHALL BE INSTALLED IN | | | ACCORDANCE WITH THE GENERAL PROVISIONS SPECIFIED IN | | | SECTIONS E3901.2.1 THROUGH E3901.2.3 (SEE FIGURE | | | E3901.2). | | | | | | | | | | | | | | | MARIO VALDES | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6700 | | | ALERNATE CONTACT | | | PHIL PETTY | | | 561-805-6742 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2015-12-12 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2015-12-12 |
Time |
09:48 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2015-12-12 |
Time |
09:48 |
Sent To |
|
|
| Notes |
| 2015-12-12 09:52:44 | 1ST REVIEW: FBC 2014 | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | 1. GAS HAS NOT BEEN REVIEWED UNDER THIS PERMIT A | | | SEPARATE APPLICATION REQUIRED FOR GAS. | | | GAS PERMIT APPLICATION REQUIREMENTS | | | | | | EFFECTIVE IMMEDIATELY THE FOLLOWING INFORMATION SHALL | | | BE SHOWN ON ALL GAS DRAWINGS SUBMITTED FOR PERMITTING | | | IN THE CITY OF WEST PALM BEACH: | | | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT CLEARLY SHOWS ALL | | | CUT SECTIONS OF PIPE AND CORRESPONDING LENGTHS PER | | | FBC-2014 FUEL GAS, SECS. 402.4.1, 402.4.2. | | | | | | 2. SHOW TYPE OF PIPING MATERIAL BEING INSTALLED, ALL | | | PIPE SIZES, AND THE EHD NUMBER OF CORRUGATED STAINLESS | | | STEEL TUBING FOR EACH PIPE SIZE IF BEING USED. WPB | | | AMENDMENTS TO FBC SEC. 107.2.1. | | | | | | 3. TYPE OF GAS, (LP OR NATURAL). | | | | | | 4. BTU LOAD OF EACH APPLIANCE AND THE TOTAL BTU LOAD ON | | | THE SYSTEM. REFER TO THE FBC-2014 FUEL GAS SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU 402.4(37). | | | | | | 5. SHOW THE DISTANCE FROM THE POINT OF DELIVERY, | | | (METER), TO THE MOST REMOTE OUTLET IN THE BUILDING | | | AND/OR SYSTEM PER THE FBC-2014 FUEL GAS APPENDIX A ? | | | USE OF CAPACITY SECTION A.3.1(4) & 2014 FUEL GAS CODE | | | SEC. 402.4.1. | | | | | | 6. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE | | | FBC-2014 FUEL GAS CODE SEC. 304. | | | | | | 7. INDICATE THE DELIVERY PRESSURE (PSI) PER FBC-2014 | | | FUEL GAS SEC. 402.2. IF NATURAL GAS SPECIFY .5 PSI OR 2 | | | PSI. | | | | | | 8. SUBMIT A DETAIL SHOWING THE TYPE, LOCATION, SIZE AND | | | TERMINATION OF THE GAS VENTS PER FBC-2014 FUEL GAS CODE | | | SEC. 502 THRU 505. | | | | | | 9. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS FOR ALL | | | GAS EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA | | | 54, NFPA 58, AND FBC-2014 FUEL GAS SEC. 402.2 | | | | | | 10. CLEARLY SHOW THE LOCATION AND CAPACITY OF LP | | | TANK(S), TYPE OF TANK (DOT OR ASME), THE DISTANCE OF | | | THE TANK FROM THE BUILDING AND ADJACENT PROPERTY LINES | | | THE DISTANCE OF THE TANK FROM ALL SOURCES OF IGNITION, | | | OTHER CONTAINERS, BUILDINGS, AND THE LOCATION OF ANY | | | BUILDING OPENINGS BELOW THE RELIEF VALVE OF THE TANK | | | PER NFPA 58, TABLE 3-2.2.2. | | | | | | 11. CLEARLY INDICATE ON THE PLAN IF THE LP TANK IS | | | ABOVE OR BELOW GROUND, AND SHOW REQUIRED PROTECTION OF | | | THE TANK AND APPURTENANCES PER NFPA 58. IF THE TANK IS | | | BELOW GROUND THE CONTAINER SHALL BE SECURELY ANCHORED | | | PER NFPA 58 SECTION 3-2.2.7(H). | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2015-12-15 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2015-12-15 |
Time |
13:06 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2015-12-15 |
Time |
13:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2015-11-17 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2015-11-17 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2015-11-17 |
Time |
14:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-12-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2015-12-21 |
Time |
09:48 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2015-12-07 |
Time |
10:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-11-18 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-11-18 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-10-19 |
Time |
10:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2015-12-15 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-12-15 |
Time |
12:05 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-12-15 |
Time |
11:38 |
Sent To |
|
|
| Notes |
| 2015-12-15 12:09:22 | PROVISO: | | | | | | THE OWNER OR OWNER'S ARCHITECT SHALL SIGN THE ENERGY | | | COMPLIANCE FORM R405-2014 PRIOR TO PERMIT ISSUANCE. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2015-11-18 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-11-18 |
Time |
14:10 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-11-18 |
Time |
12:35 |
Sent To |
|
|
| Notes |
| 2015-11-18 14:30:35 | 1ST REVIEW: FBC 2014 RESIDENTIAL | | | PERMIT #15100627 | | | 11/18/15 | | | | | | 1) THE MANUAL J WORKSHEETS INDICATE 195 CFM'S OF | | | COOLING AND 224 CFM'S OF HEATING ARE REQUIRED FOR THE | | | DEN. PLEASE CLARIFY HOW SUPPLY AIR AND RETURN AIR ARE | | | BEING PROVIDED TO AND FROM THE ROOM- WILL THERE BE TWO | | | TRANSFER GRILLS? | | | 2) REFER TO SECTION M1305.1.3 FBC-14 RESIDENTIAL | | | ANDR403.2.4 FBC-14 ENERGY CONSERVATION AND PROVIDE THE | | | DIMENSIONS OF THE ATTIC ACCESS, AND CONSTRUCTION | | | DETAILS AND NOTES INDICATING COMPLIANCE. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2015-12-12 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2015-12-12 |
Time |
09:47 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2015-12-12 |
Time |
09:46 |
Sent To |
|
|
| Notes |
| 2015-12-12 09:48:04 | SEPARATE GAS PERMIT REQUIRED |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2015-10-26 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2015-10-26 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2015-10-26 |
Time |
16:32 |
Sent To |
|
|
| Notes |
| 2015-10-26 16:36:29 | | | | 1ST REVIEW: FBC 2014 | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | | | | 1. NO WATER HEATER SHOWN PROVIDE LOCATION AND | | | SPECIFICATIONS FOR WATER HEATER. PEWR WPB AMEND. TO FBC | | | SEC 107.2.1 AND 107.2.1.3 |
|
|