| Plan Review Stops For Permit 15100589 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2016-01-09 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-01-09 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-01-09 |
Time |
11:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2015-12-09 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-12-09 |
Time |
12:00 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-12-09 |
Time |
11:43 |
Sent To |
|
|
| Notes |
| 2015-12-09 11:46:59 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 15100589 | | | ADD: 1600 N DIXIE HWY. | | | CONT: RJS CONSTRUCTION GROUP, INC. | | | TEL: (561)795-4712 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: MON. NOV. 02/2015 | | | ACTION: DENIED | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | | | | 1) COMPLIED. THE A2.3 & M2 SHEETS SHOW 3 NEW RTU UNITS | | | ON THE EXISITNG ROOF TOP. PLEASE PROVIDE A ROOF FRAMING | | | PLAN SHOWING THE NEW ROOF TOP OPENINGS THE NEW FRAMING | | | MEMBERS, HEADERS, HANGERS AND OR BUCKETS FOR THE NEW | | | OPENINGS. 2014 FBC-B 2308.10.4.3. | | | | | | 2) 2ND REQUEST. PLEASE PROVIDE THE PRODUCT APPROVALS | | | FOR THE NEW RTU ROOF TOP CURBS, ROOF PATCHING AROUND | | | THE CURBS AND NEW EXHAUST VENT. 2014 FBC-B 1609.1.2 | | | PROTECTION OF OPENINGS, 1609.6.4.4.1 COMPONENTS & | | | CLADDING. FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE | | | 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR | | | CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT | | | APPROVALS: | | | (31)(D) ROOFING PRODUCTS AND ASSEMBLIES/ AND ROOF TOP | | | RTU CURBS | | | | | | 3) 2ND REQUEST. 107.3.4.1 THOSE PRODUCTS WHICH ARE | | | REGULATED BY DCA RULE 9N-3SHALL BE REVIEWED AND | | | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO | | | SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | | | 4) COMPLIED. | | | | | | 5) 2ND REQUEST. PLEASE PROVIDE ENERGYY CALCULATIONS IN | | | ACCORDANCE WITH 2014 ENERGY CODE SECTION C101.4.3. SEE | | | MECHANICAL COMMENTS. | | | | | | 6) COMPLIED. SHEET A2.1 DOES NOT INDICATE THE TYPE OF | | | ROOF DECK NOR FRAMING. THIS STRUCTURE HAS WOOD 2X'S AND | | | WOOD DECK. THE NEW TENANT SEPARATION WALL WILL NEED TO | | | GO ALL THE WAY TO THE ROOF DECK. PLEASE PROVIDE A | | | DETAIL OF HOW THE FIRE RATING WILL BE MAINTAINED TO THE | | | ROOF DECK. THIS WILL BE DISSIMILAR MATERIALS, WILL ALSO | | | NEED TO BE A FLEXIBLE CONNECTION BECAUSE OF THE HEATING | | | AND COOLING OF THE ROOF DECK. PLEASE SHOW COMPLIANCE | | | WITH 2014 FBC-B 708.8 JOINTS MADE IN OR BETWEEN FIRE | | | BARRIERS SHALL COMPLY WITH 715. | | | | | | 7) NEW COMMENT, THIS IS AN UNUSAL BUILDING SINCE NONE | | | OF THE TENANT SPACES HAVE DOORWAYS THAT EXIT ONTO A | | | PUBLIC RIGHT OF WAY. PLEASE PROVIDE A SITE PLAN SHOWING | | | COMPLIANCE WITH: | | | 2014 FBC-B 1027.5 ACCESS TO A PUBLIC WAY. THE EXIT | | | DISCHARGE SHALL PROVIDE A DIRECT AND UNOBSTRUCTED | | | ACCESS TO A PUBLIC WAY. | | | 2014 FBC-ACCESSIBILITY CODE 206.2.4 SPACES AND | | | ELEMENTS. AT LEAST ONE ACCESSIBLE ROUTE SHALL CONNECT | | | ACCESSIBLE BUILDING OR FACILITY ENTRANCES WITH ALL | | | ACCESSIBLE SPACES AND ELEMENTS WITHIN THE BUILDING OR | | | FACILITY WHICH ARE OTHERWISE CONNECTED BY A CIRCULATION | | | PATH TO THE PUBLIC WAY, UNLESS EXEMPTED BY 206.2.3 | | | EXCEPTIONS 1 THROUGH 7. | | | 2014 FBC-ACCESSIBILITY 208.3.1 WHERE IN THE ACCESSIBLE | | | PARKING SPACE AND ACCESS AISLE THE PATRON IS NOT | | | COMPELLED TO WALK OR WHEEL BEHIND PARKED CARS. | | | | | | 8) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-11-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-11-02 |
Time |
16:26 |
Rev Time |
|
| Received By |
jwitmer |
Date |
2015-11-02 |
Time |
14:46 |
Sent To |
|
|
| Notes |
| 2015-11-02 16:26:27 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 15100589 | | | ADD: 1600 N DIXIE HWY. | | | CONT: RJS CONSTRUCTION GROUP, INC. | | | TEL: (561)795-4712 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: MON. NOV. 02/2015 | | | ACTION: DENIED | | | | | | 1) THE A2.3 & M2 SHEETS SHOW 3 NEW RTU UNITS ON THE | | | EXISITNG ROOF TOP. PLEASE PROVIDE A ROOF FRAMING PLAN | | | SHOWING THE NEW ROOF TOP OPENINGS THE NEW FRAMING | | | MEMBERS, HEADERS, HANGERS AND OR BUCKETS FOR THE NEW | | | OPENINGS. 2014 FBC-B 2308.10.4.3. | | | | | | 2) PLEASE PROVIDE THE PRODUCT APPROVALS FOR THE NEW RTU | | | ROOF TOP CURBS, ROOF PATCHING AROUND THE CURBS AND NEW | | | EXHAUST VENT. 2014 FBC-B 1609.1.2 PROTECTION OF | | | OPENINGS, 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA | | | DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 | | | (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS | | | THAT WILL REQUIRE PRODUCT APPROVALS: | | | (31)(D) ROOFING PRODUCTS AND ASSEMBLIES/ AND ROOF TOP | | | RTU CURBS | | | | | | 3) 107.3.4.1 THOSE PRODUCTS WHICH ARE REGULATED BY DCA | | | RULE 9N-3SHALL BE REVIEWED AND APPROVED IN WRITING BY | | | THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. | | | | | | 4) PLEASE ALSO PROVIDE THE TIE DOWN OF THE ROOF TOP RTU | | | UNIT TO THE ROOF TOP CURBS. 2014 FBC-B COMPONENTS AND | | | CLADDING 1609.6.4.4.1.2014 FBC-B 1603.1.4 WIND DESIGN | | | DATA. | | | THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL | | | BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE | | | DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE | | | STRUCTURE: | | | | | | 4.1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST), | | | MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED, | | | VASD, AS DETERMINED IN ACCORDANCE WITH SECTION | | | 1609.3.1. | | | | | | 4.2. RISK CATEGORY. | | | | | | 4.3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE | | | THAN ONE WIND EXPOSURE IS UTILIZED. | | | | | | 4.4. APPLICABLE INTERNAL PRESSURE COEFFICIENT. | | | | | | 4.5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR | | | COMPONENT AND CLADDING MATERIALS NOT SPECIFICALLY | | | DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL | | | RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF (KN/ | | | M2). | | | | | | TABLE 1609.7(2) ADJUSTMENT FACTORS FOR HEIGHT & | | | EXPOSURE. PROVIDE THE MEAN ROOF HEIGHT FOR THE | | | BUILDING. | | | | | | 5) PLEASE PROVIDE ENERGYY CALCULATIONS IN ACCORDANCE | | | WITH 2014 ENERGY CODE SECTION C101.4.3. | | | | | | 6) SHEET A2.1 DOES NOT INDICATE THE TYPE OF ROOF DECK | | | NOR FRAMING. THIS STRUCTURE HAS WOOD 2X'S AND WOOD | | | DECK. THE NEW TENANT SEPARATION WALL WILL NEED TO GO | | | ALL THE WAY TO THE ROOF DECK. PLEASE PROVIDE A DETAIL | | | OF HOW THE FIRE RATING WILL BE MAINTAINED TO THE ROOF | | | DECK. THIS WILL BE DISSIMILAR MATERIALS, WILL ALSO NEED | | | TO BE A FLEXIBLE CONNECTION BECAUSE OF THE HEATING AND | | | COOLING OF THE ROOF DECK. PLEASE SHOW COMPLIANCE WITH | | | 2014 FBC-B 708.8 JOINTS MADE IN OR BETWEEN FIRE | | | BARRIERS SHALL COMPLY WITH 715. | | | | | | 715.2 INSTALLATION. A FIRE-RESISTANT JOINT SYSTEM SHALL | | | BE SECURELY INSTALLED IN ACCORDANCE WITH THE LISTING | | | CRITERIA IN OR ON THE JOINT FOR ITS ENTIRE LENGTH SO AS | | | NOT TO DISLODGE, LOOSEN OR OTHERWISE IMPAIR ITS ABILITY | | | TO ACCOMMODATE EXPECTED BUILDING MOVEMENTS AND TO | | | RESIST THE PASSAGE OF FIRE AND HOT GASES. | | | | | | 715.3 FIRE TEST CRITERIA. FIRE-RESISTANT JOINT SYSTEMS | | | SHALL BE TESTED IN ACCORDANCE WITH THE REQUIREMENTS OF | | | EITHER ASTM E 1966 OR UL 2079. NONSYMMETRICAL WALL | | | JOINT SYSTEMS SHALL BE TESTED WITH BOTH FACES EXPOSED | | | TO THE FURNACE, AND THE ASSIGNED FIRE-RESISTANCE RATING | | | SHALL BE THE SHORTEST DURATION OBTAINED FROM THE TWO | | | TESTS. WHEN EVIDENCE IS FURNISHED TO SHOW THAT THE WALL | | | WAS TESTED WITH THE LEAST FIRE-RESISTANT SIDE EXPOSED | | | TO THE FURNACE, SUBJECT TO ACCEPTANCE OF THE BUILDING | | | OFFICIAL, THE WALL NEED NOT BE SUBJECTED TO TESTS FROM | | | THE OPPOSITE SIDE. | | | | | | 8) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2016-01-14 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-01-14 |
Time |
19:04 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-01-14 |
Time |
19:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2015-12-16 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2015-12-16 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2015-12-16 |
Time |
13:37 |
Sent To |
|
|
| Notes |
| 2015-12-16 14:10:06 | REVIEW: FBC 2014 5TH ED. NEC 2011 | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 516-805-6700 | | | [email protected] | | | ALTERNATE CONTACT | | | MIKE ALBARRAN | | | 561-805-6746 | | | [email protected] | | | | | | | | | PAGE E -1 | | | | | | 230.7 OTHER CONDUCTORS IN RACEWAY OR CABLE. CONDUCTORS | | | OTHER THAN SERVICE CONDUCTORS SHALL NOT BE INSTALLED IN | | | THE SAME SERVICE RACEWAY OR SERVICE CABLE. | | | ( FUSED AND UNFUSED IN SAME CONDUIT. ) | | | | | | | | | PROVIDE NEW RISER DIAGRAM AND LOAD CALCULATIONS FOR | | | ENTIRE ELECTRICAL SYSTEM INCLUDING EXISTING. | | | SHOW PROPER GROUNDING OF SERVICE TO INCLUDE | | | SUPPLEMENTAL GROUND ROD AND WATER/METAL BONDING. NEC | | | 250.53 | | | ( DON'T FORGET NEC 250.94 INTERSYSTEM BONDING. ) | | | | | | 110.16 ARC-FLASH HAZARDWARNING. ELECTRICAL EQUIPMENT, | | | SUCH AS SWITCHBOARDS, PANELBOARDS, INDUSTRIAL CONTROL | | | PANELS, | | | METER SOCKET ENCLOSURES, AND MOTOR CONTROL CENTERS, | | | THAT | | | ARE IN OTHER THAN DWELLING UNITS, AND ARE LIKELY TO | | | REQUIRE | | | EXAMINATION, ADJUSTMENT, SERVICING, OR MAINTENANCE | | | WHILE | | | ENERGIZED SHALL BE FIELD MARKED TO WARN QUALIFIED | | | PERSONS OF | | | POTENTIAL ELECTRIC ARC FLASH HAZARDS. THE MARKING SHALL | | | BE | | | LOCATED SO AS TO BE CLEARLY VISIBLE TO QUALIFIED | | | PERSONS BEFORE | | | EXAMINATION, ADJUSTMENT, SERVICING, OR MAINTENANCE OF | | | THE EQUIPMENT. | | | | | | | | | PAGE E-2 | | | | | | 406.9 RECEPTACLES IN DAMP OR WET LOCATIONS. | | | (B) WET LOCATIONS. | | | (1) 15- AND 20-AMPERE RECEPTACLES IN A WET LOCATION. | | | 15- AND 20-AMPERE, 125- AND 250-VOLT RECEPTACLES | | | INSTALLED IN | | | A WET LOCATION SHALL HAVE AN ENCLOSURE THAT IS | | | WEATHERPROOF | | | WHETHER OR NOT THE ATTACHMENT PLUG CAP IS INSERTED. FOR | | | OTHER | | | THAN ONE- OR TWO-FAMILY DWELLINGS, AN OUTLET BOX HOOD | | | INSTALLED | | | FOR THIS PURPOSE SHALL BE LISTED, AND WHERE INSTALLED | | | ON | | | AN ENCLOSURE SUPPORTED FROM GRADE AS DESCRIBED IN | | | 314.23(B) | | | OR AS DESCRIBED IN 314.23(F) SHALL BE IDENTIFIED AS | | | ?EXTRA-DUTY.? | | | ALL 15- AND 20-AMPERE, 125- AND 250-VOLT | | | NONLOCKING-TYPE | | | RECEPTACLES SHALL BE LISTED WEATHER-RESISTANT TYPE. | | | | | | | | | NEC 410.30 LUMINAIRE SUPPORT | | | SUSPENDED CEILINGS. FRAMING MEMBERS OF SUSPENDED | | | CEILING SYSTEMS USED TO SUPPORT LUMINAIRES SHALL BE | | | SECURELY | | | FASTENED TO EACH OTHER AND SHALL BE SECURELY ATTACHED | | | TO THE | | | BUILDING STRUCTURE AT APPROPRIATE INTERVALS. LUMINAIRES | | | SHALL | | | BE SECURELY FASTENED TO THE CEILING FRAMING MEMBER BY | | | MECHANICAL | | | MEANS SUCH AS BOLTS, SCREWS, OR RIVETS. LISTED CLIPS | | | IDENTIFIED FOR USE WITH THE TYPE OF CEILING FRAMING | | | MEMBER( | | | S) AND LUMINAIRE(S) SHALL ALSO BE PERMITTED. | | | | | | | | | 600.5 BRANCH CIRCUITS. | | | (A) REQUIRED BRANCH CIRCUIT. EACH COMMERCIAL BUILDING | | | AND EACH COMMERCIAL OCCUPANCY ACCESSIBLE TO PEDESTRIANS | | | SHALL BE PROVIDED WITH AT LEAST ONE OUTLET IN AN | | | ACCESSIBLE | | | LOCATION AT EACH ENTRANCE TO EACH TENANT SPACE FOR SIGN | | | OR | | | OUTLINE LIGHTING SYSTEM USE. THE OUTLET(S) SHALL BE | | | SUPPLIED | | | BY A BRANCH CIRCUIT RATED AT LEAST 20 AMPERES THAT | | | SUPPLIES | | | NO OTHER LOAD. SERVICE HALLWAYS OR CORRIDORS SHALL NOT | | | BE | | | CONSIDERED ACCESSIBLE TO PEDESTRIANS. | | | ( MISSING SIGN OUTLET BY SINGLE DOOR ADJACENT TO PANEL. | | | ) | | | | | | PROVIDE COMPLIANCE FOR ALL LIGHTING IN ACCORDANCE WITH | | | FBC ENERGY CODE C405 ( LIGHTING CONTROLS ) |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
N |
Date |
2015-11-05 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2015-11-05 |
Time |
10:15 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2015-11-05 |
Time |
10:15 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2016-01-07 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2016-01-07 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2016-01-07 |
Time |
15:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2015-11-30 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2015-11-30 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2015-11-30 |
Time |
13:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2015-10-29 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2015-10-29 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2015-10-29 |
Time |
15:07 |
Sent To |
|
|
| Notes |
| 2015-10-29 16:20:39 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | 1. SHEET A 2.1, INDICATES A DOOR SCHEDULE WITH THE DOOR | | | HARWARE AS "EX", EXISTING. | | | | | | PER NFPA 101, CHAPTER 7, 7.2.1.5.5 KEY-OPERATED LOCKS | | | | | | 7.2.1.5.5.1 EXTERIOR DOOR ASSEMBLIES SHALL BE PERMITTED | | | TO HAVE KEY-OPERATED LOCKS FROM THE EGRESS SIDE, | | | PROVIDED THAT ALL OF THE FOLLOWING CRITERIA ARE MET. | | | | | | (1) THIS ALTERNATIVE IS PERMITTED IN CHAPTERS 11 | | | THROUGH 43 FOR THE SPECIFIC OCCUPANCY. ( IT IS | | | PERMITTED UNDER CHAPTER 39, EXISTING BUSINESS | | | OCCUPANCY) | | | | | | (2) A READILY VISIBLE, DURABLE SIGN IN LETTERS NOT LESS | | | THAN 1 IN. HIGH ON A CONTRASTING BACKGROUND THAT READS | | | AS FOLLOWS IS LOCATED ON OR ADJACENT TO THE DOOR LEAF. | | | THIS DOOR TO REMAIN UNLOCKED WHEN THE BUILDING IS | | | OCCUPIED. | | | | | | (3) THE LOCKING DEVICE IS OF A TYPE THAT IS READILY | | | DISTINGUISHABLE AS LOCKED. | | | | | | (4) A KEY IS IMMEDIATELY AVAILABLE TO ANY OCCUPANT | | | INSIDE THE BUILDING WHEN IT IS LOCKED. | | | | | | SHOULD ALL OF THE ABOVE NOT BE POSSIBLE: | | | | | | 7.2.1.5.1 DOOR LEAVES SHALL BE ARRANGED TO BE OPENED | | | READILY FROM THE EGRESS SIDE WHENEVER THE BUILDING IS | | | OCCUPIED. | | | | | | 7.2.1.5.3 LOCKS, IF PROVIDED, SHALL NOT REQUIRE THE USE | | | OF A KEY, A TOOL, OR SPECIAL KNOWLEDGE OR EFFORT FOR | | | OPERATION FROM THE EGRESS SIDE. | | | | | | 7.2.1.5.10 A LATCH OR OTHER FASTENING DEVICE ON A DOOR | | | LEAF SHALL BE PROVIDED WITH A RELEASING DEVICE THAT HAS | | | AN OBVIOUS METHOD OF OPERATION AND THAT IS READILY | | | OPERATED UNDER ALL LIGHTING CONDITIONS. | | | | | | 7.2.1.5.10.2 THE RELEASING MECHANISM SHALL OPEN THE | | | DOOR LEAF WITH NOT MORE THAN ONE RELEASING OPERATION. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2016-01-28 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2016-01-28 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2015-12-30 |
Time |
14:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2015-12-29 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-12-29 |
Time |
08:57 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-12-28 |
Time |
14:06 |
Sent To |
|
|
| Notes |
| 2015-12-28 14:06:31 | CCOLE'S DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-12-16 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2015-12-16 |
Time |
14:23 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2015-11-25 |
Time |
13:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-11-24 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2015-11-24 |
Time |
13:43 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2015-10-19 |
Time |
17:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2015-12-31 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-12-31 |
Time |
09:12 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-12-31 |
Time |
09:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2015-12-29 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-12-29 |
Time |
08:55 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-12-29 |
Time |
08:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2015-12-29 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-12-02 |
Time |
08:55 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-12-02 |
Time |
07:02 |
Sent To |
|
|
| Notes |
| 2015-12-02 07:44:13 | 1ST REVIEW 2014 MECHANICAL | | | PERMIT #15100589 | | | 12/2/15 | | | | | | 1) AS PREVIOUSLY REQUESTED IN THE FIRST REVIEW, PROVIDE | | | AC COOLING AND HEATING CALCULATIONS IN ACCORDANCE WITH | | | ACCA MANUAL N OR ASHRAE/ACCA STANDARD 183. | | | 2) HEAT LOAD SUMMARY ON SHEET M-1: A) THE SUMMARY WAS | | | CALCULATED USING CARRIER SOFTWARE HOWEVER TRANE UNITS | | | HAVE BEEN SELECTED. B) PROVIDE DOCUMENTATION VERIFYING | | | THE PROGRAM IS ACCA OR ASHRAE APPROVED. C) THE TOTAL | | | COOLING OF 6.5- TONS INDICATED IN THE SUMMARY IS MUCH | | | LESS THAN THE 9-TONS OF COOLING TO BE PROVIDED TO THE | | | TENANT SPACE USING THE THREE 3-TON RTU'S- PLEASE SEE | | | SECTION C403.2.2 FBC-14 ENERGY CONSERVATION, EQUIPMENT | | | AND SYSTEM SIZING. | | | THE OUTPUT CAPACITY OF HEATING AND COOLING EQUIPMENT | | | AND SYSTEMS SHALL NOT EXCEED THE LOADS CALCULATED IN | | | ACCORDANCE WITH SECTION C403.2.1. A SINGLE PIECE OF | | | EQUIPMENT PROVIDING BOTH HEATING AND COOLING SHALL | | | SATISFY THIS PROVISION FOR ONE FUNCTION WITH THE | | | CAPACITY FOR THE OTHER FUNCTION AS SMALL AS POSSIBLE, | | | WITHIN AVAILABLE EQUIPMENT OPTIONS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2015-10-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-10-28 |
Time |
10:30 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-10-28 |
Time |
10:30 |
Sent To |
|
|
| Notes |
| 2015-10-28 10:42:43 | 1ST REVIEW: FBC 2014 MECHANICAL | | | PERMIT #15100589 | | | 10/28/15 | | | | | | 1) PROVIDE AC COOLING AND HEATING CALCULATIONS FOR THE | | | NEW RTU'S IN COMPLIANCE WITH SECTION C403.2.1 FBC-14 | | | ENERGY CONSERVATION. | | | 2) PROVIDE ENERGY CALCULATIONS IN ACCORDANCE WITH | | | SECTION C101.4.3 FBC-14 ENERGY CONSERVATION. | | | 3) DUCT SMOKE DETECTORS ARE REQUIRED IN THE RETURN AIR | | | SYSTEMS- SEE SECTION 606.2.1 & 606.2,.2 FBC-14 | | | MECHANICAL. | | | 4) WIND LOAD TIE DOWN ENGINEERING IS REQUIRED FOR | | | ATTACHING THE RTU'S AND CURBS TO THE STRUCTURE- REFER | | | TO SECTION 301.15 FBC-14 MECHANICAL. | | | 5) PROVIDE A CROSS-SECTION VIEW OF THE RTU AND CURB | | | INDICATING THE CURB MATERIALS, ROOF PATCHING DETAILS, | | | AND THE HEIGHT OF THE CURB ABOVE THE ROOF. | | | 6) PROVIDE A CONDENSATE DISPOSABLE PLAN SHOWING THE THE | | | TYPES AND SIZES OF CONDENSATE PIPING, PIPING RUNS, | | | PIPING SUPPORT, DISCHARGE LOCATIONS, AND PIPE | | | PROTECTION FROM UV DEGRADATION. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2015-10-21 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2015-10-21 |
Time |
16:43 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2015-10-21 |
Time |
16:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2016-01-27 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2016-01-27 |
Time |
12:03 |
Rev Time |
2.00 |
| Received By |
eschneid |
Date |
2016-01-27 |
Time |
12:03 |
Sent To |
PC |
|
| Notes |
| 2016-01-27 15:34:45 | PASSED | | | | | | 1) PRIOR TO THE FIRST INSPECTION, A PERMIT TO RESTRIPE | | | THE PARKING LOT SHALL BE SUBMITTED. THE PERMIT PLAN SET | | | SHALL INCLUDE THE ADA PARKING SPACES, THE ACCESSIBLE | | | WALKWAY ALONG THE DOORS ACCESSING THE PARKING LOT, THE | | | DUMPSTER LOCATION AND LANDSCAPE AREAS AS APPROVED BY | | | PLANNING STAFF. THE CURBING AND STRIPING SHOWN ON THE | | | ISSUED PARKING LOT PERMIT SHALL BE COMPLETED PRIOR TO | | | THE FINAL (104) INSPECTION/CERTIFICATE OF COMPLETION OF | | | THE VANILLA BOX PERMIT OR CERTIFICATE OF OCCUPANCY FOR | | | THE SPACE, WHICHEVER FIRST OCCURS. | | | | | | 2) IN ORDER TO MITIGATE THE REQUIRED LANDSCAPING ALONG | | | DIXIE HIGHWAY THAT WAS REMOVED AS PART OF PERMIT | | | 11050756 AND NOT REPLACED AS PART OF EXPIRED PERMIT | | | 11100171, A LANDSCAPE PERMIT, WITH A LANDSCAPE PLAN | | | APPROVED BY PLANNING STAFF, SHALL BE SUBMITTED AND BE | | | ISSUED PRIOR TO THE FINAL (104) INSPECTION/CERTIFICATE | | | OF COMPLETION OF THE VANILLA BOX PERMIT. THE LANDSCAPE | | | WORK SHALL BE COMPLETED PRIOR TO A CERTIFICATE OF | | | OCCUPANCY FOR THE BUILIDNG. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2015-12-17 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2015-12-17 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2015-12-17 |
Time |
11:06 |
Sent To |
|
|
| Notes |
| 2015-12-17 11:08:04 | FAILED | | | | | | COMMENTS FROM PREVIOUS REVIEW STILL APPLY. IT IS ZONING | | | STAFF UNDERSTANDING THAT A PARKING PLAN WILL BE | | | SUBMITTED WITH THE NEXT SUBMITTAL. ZONING WILL PERFORM | | | ITS REVIEW AT THAT TIME. | | | | | | THIS DOES NOT COUNT AS A ZONING REVIEW CYCLE. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2015-11-24 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2015-11-24 |
Time |
08:54 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2015-11-24 |
Time |
08:54 |
Sent To |
|
|
| Notes |
| 2015-11-24 09:03:48 | FAILED | | | | | | 1) PRIOR TO ZONING APPROVAL OF THIS PERMIT, A STRIPING | | | PLAN FOR THE PARKING LOT SHALL BE SUBMITTED. PLEASE | | | NOTE THAT IF THE ULTIMATE BUILD-OUT OF THE SPACE WILL | | | TRIGGER 50% OF THE BUILDING VALUE WITHIN A ONE-YEAR | | | PERIOD, THE PARKING AREA SHALL BE BROUGHT INTO | | | CONFORMITY WITH THE LANDSCAPE CODE. ADDITIONALLY, AT | | | LEAST ONE TREE HAS BEEN REMOVED FROM THE PARKING LOT | | | WITHOUT THE APPROVAL OF A TREE ALTERATION PERMIT AND | | | THUS SHALL BE REPLACED. THE STRIPING PERMIT SHALL BE | | | COMPLETED PRIOR TO A CERTIFICATE OF OCCUPANCY FOR THE | | | SPACE. | | | | | | 2) THE REQUIRED LANDSCAPING ALONG DIXIE HIGHWAY THAT | | | WAS REMOVED AS PART OF PERMIT 11050756 AND NOT REPLACED | | | AS PART OF EXPIRED PERMIT 11100171 SHALL BE REPLACED AS | | | PART OF THIS PERMIT (AND SHALL BE SHOWN ON THE PERMIT) | | | OR AS A SEPARATE LANDSCAPE PERMIT THAT IS SUBMITTED | | | PRIOR TO ZONING APPROVAL OF THIS PERMIT. THE LANDSCAPE | | | WORK SHALL BE COMPLETED PRIOR TO A CERTIFICATE OF | | | COMPLETION FOR THIS PERMIT. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | | | | | |
|
|