Plan Review Details - Permit 15100589
Plan Review Stops For Permit 15100589
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2016-01-09 Cont ID  
Sent By jwitmer Date 2016-01-09 Time 11:30 Rev Time 0.00
Received By jwitmer Date 2016-01-09 Time 11:00 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2015-12-09 Cont ID  
Sent By jwitmer Date 2015-12-09 Time 12:00 Rev Time 0.00
Received By jwitmer Date 2015-12-09 Time 11:43 Sent To  
Notes
2015-12-09 11:46:59BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15100589
 ADD: 1600 N DIXIE HWY.
 CONT: RJS CONSTRUCTION GROUP, INC.
 TEL: (561)795-4712
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: MON. NOV. 02/2015
 ACTION: DENIED
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
  
 1) COMPLIED. THE A2.3 & M2 SHEETS SHOW 3 NEW RTU UNITS
 ON THE EXISITNG ROOF TOP. PLEASE PROVIDE A ROOF FRAMING
 PLAN SHOWING THE NEW ROOF TOP OPENINGS THE NEW FRAMING
 MEMBERS, HEADERS, HANGERS AND OR BUCKETS FOR THE NEW
 OPENINGS. 2014 FBC-B 2308.10.4.3.
  
 2) 2ND REQUEST. PLEASE PROVIDE THE PRODUCT APPROVALS
 FOR THE NEW RTU ROOF TOP CURBS, ROOF PATCHING AROUND
 THE CURBS AND NEW EXHAUST VENT. 2014 FBC-B 1609.1.2
 PROTECTION OF OPENINGS, 1609.6.4.4.1 COMPONENTS &
 CLADDING. FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE
 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR
 CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT
 APPROVALS:
 (31)(D) ROOFING PRODUCTS AND ASSEMBLIES/ AND ROOF TOP
 RTU CURBS
  
 3) 2ND REQUEST. 107.3.4.1 THOSE PRODUCTS WHICH ARE
 REGULATED BY DCA RULE 9N-3SHALL BE REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO
 SUBMITTAL FOR JURISDICTIONAL APPROVAL.
  
 4) COMPLIED.
  
 5) 2ND REQUEST. PLEASE PROVIDE ENERGYY CALCULATIONS IN
 ACCORDANCE WITH 2014 ENERGY CODE SECTION C101.4.3. SEE
 MECHANICAL COMMENTS.
  
 6) COMPLIED. SHEET A2.1 DOES NOT INDICATE THE TYPE OF
 ROOF DECK NOR FRAMING. THIS STRUCTURE HAS WOOD 2X'S AND
 WOOD DECK. THE NEW TENANT SEPARATION WALL WILL NEED TO
 GO ALL THE WAY TO THE ROOF DECK. PLEASE PROVIDE A
 DETAIL OF HOW THE FIRE RATING WILL BE MAINTAINED TO THE
 ROOF DECK. THIS WILL BE DISSIMILAR MATERIALS, WILL ALSO
 NEED TO BE A FLEXIBLE CONNECTION BECAUSE OF THE HEATING
 AND COOLING OF THE ROOF DECK. PLEASE SHOW COMPLIANCE
 WITH 2014 FBC-B 708.8 JOINTS MADE IN OR BETWEEN FIRE
 BARRIERS SHALL COMPLY WITH 715.
  
 7) NEW COMMENT, THIS IS AN UNUSAL BUILDING SINCE NONE
 OF THE TENANT SPACES HAVE DOORWAYS THAT EXIT ONTO A
 PUBLIC RIGHT OF WAY. PLEASE PROVIDE A SITE PLAN SHOWING
 COMPLIANCE WITH:
 2014 FBC-B 1027.5 ACCESS TO A PUBLIC WAY. THE EXIT
 DISCHARGE SHALL PROVIDE A DIRECT AND UNOBSTRUCTED
 ACCESS TO A PUBLIC WAY.
 2014 FBC-ACCESSIBILITY CODE 206.2.4 SPACES AND
 ELEMENTS. AT LEAST ONE ACCESSIBLE ROUTE SHALL CONNECT
 ACCESSIBLE BUILDING OR FACILITY ENTRANCES WITH ALL
 ACCESSIBLE SPACES AND ELEMENTS WITHIN THE BUILDING OR
 FACILITY WHICH ARE OTHERWISE CONNECTED BY A CIRCULATION
 PATH TO THE PUBLIC WAY, UNLESS EXEMPTED BY 206.2.3
 EXCEPTIONS 1 THROUGH 7.
 2014 FBC-ACCESSIBILITY 208.3.1 WHERE IN THE ACCESSIBLE
 PARKING SPACE AND ACCESS AISLE THE PATRON IS NOT
 COMPELLED TO WALK OR WHEEL BEHIND PARKED CARS.
  
 8) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-11-02 Cont ID  
Sent By jwitmer Date 2015-11-02 Time 16:26 Rev Time  
Received By jwitmer Date 2015-11-02 Time 14:46 Sent To  
Notes
2015-11-02 16:26:27BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15100589
 ADD: 1600 N DIXIE HWY.
 CONT: RJS CONSTRUCTION GROUP, INC.
 TEL: (561)795-4712
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: MON. NOV. 02/2015
 ACTION: DENIED
  
 1) THE A2.3 & M2 SHEETS SHOW 3 NEW RTU UNITS ON THE
 EXISITNG ROOF TOP. PLEASE PROVIDE A ROOF FRAMING PLAN
 SHOWING THE NEW ROOF TOP OPENINGS THE NEW FRAMING
 MEMBERS, HEADERS, HANGERS AND OR BUCKETS FOR THE NEW
 OPENINGS. 2014 FBC-B 2308.10.4.3.
  
 2) PLEASE PROVIDE THE PRODUCT APPROVALS FOR THE NEW RTU
 ROOF TOP CURBS, ROOF PATCHING AROUND THE CURBS AND NEW
 EXHAUST VENT. 2014 FBC-B 1609.1.2 PROTECTION OF
 OPENINGS, 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA
 DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010
 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS
 THAT WILL REQUIRE PRODUCT APPROVALS:
 (31)(D) ROOFING PRODUCTS AND ASSEMBLIES/ AND ROOF TOP
 RTU CURBS
  
 3) 107.3.4.1 THOSE PRODUCTS WHICH ARE REGULATED BY DCA
 RULE 9N-3SHALL BE REVIEWED AND APPROVED IN WRITING BY
 THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL.
  
 4) PLEASE ALSO PROVIDE THE TIE DOWN OF THE ROOF TOP RTU
 UNIT TO THE ROOF TOP CURBS. 2014 FBC-B COMPONENTS AND
 CLADDING 1609.6.4.4.1.2014 FBC-B 1603.1.4 WIND DESIGN
 DATA.
 THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL
 BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE
 DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE
 STRUCTURE:
  
 4.1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST),
 MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED,
 VASD, AS DETERMINED IN ACCORDANCE WITH SECTION
 1609.3.1.
  
 4.2. RISK CATEGORY.
  
 4.3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE
 THAN ONE WIND EXPOSURE IS UTILIZED.
  
 4.4. APPLICABLE INTERNAL PRESSURE COEFFICIENT.
  
 4.5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR
 COMPONENT AND CLADDING MATERIALS NOT SPECIFICALLY
 DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL
 RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF (KN/
 M2).
  
 TABLE 1609.7(2) ADJUSTMENT FACTORS FOR HEIGHT &
 EXPOSURE. PROVIDE THE MEAN ROOF HEIGHT FOR THE
 BUILDING.
  
 5) PLEASE PROVIDE ENERGYY CALCULATIONS IN ACCORDANCE
 WITH 2014 ENERGY CODE SECTION C101.4.3.
  
 6) SHEET A2.1 DOES NOT INDICATE THE TYPE OF ROOF DECK
 NOR FRAMING. THIS STRUCTURE HAS WOOD 2X'S AND WOOD
 DECK. THE NEW TENANT SEPARATION WALL WILL NEED TO GO
 ALL THE WAY TO THE ROOF DECK. PLEASE PROVIDE A DETAIL
 OF HOW THE FIRE RATING WILL BE MAINTAINED TO THE ROOF
 DECK. THIS WILL BE DISSIMILAR MATERIALS, WILL ALSO NEED
 TO BE A FLEXIBLE CONNECTION BECAUSE OF THE HEATING AND
 COOLING OF THE ROOF DECK. PLEASE SHOW COMPLIANCE WITH
 2014 FBC-B 708.8 JOINTS MADE IN OR BETWEEN FIRE
 BARRIERS SHALL COMPLY WITH 715.
  
 715.2 INSTALLATION. A FIRE-RESISTANT JOINT SYSTEM SHALL
 BE SECURELY INSTALLED IN ACCORDANCE WITH THE LISTING
 CRITERIA IN OR ON THE JOINT FOR ITS ENTIRE LENGTH SO AS
 NOT TO DISLODGE, LOOSEN OR OTHERWISE IMPAIR ITS ABILITY
 TO ACCOMMODATE EXPECTED BUILDING MOVEMENTS AND TO
 RESIST THE PASSAGE OF FIRE AND HOT GASES.
  
 715.3 FIRE TEST CRITERIA. FIRE-RESISTANT JOINT SYSTEMS
 SHALL BE TESTED IN ACCORDANCE WITH THE REQUIREMENTS OF
 EITHER ASTM E 1966 OR UL 2079. NONSYMMETRICAL WALL
 JOINT SYSTEMS SHALL BE TESTED WITH BOTH FACES EXPOSED
 TO THE FURNACE, AND THE ASSIGNED FIRE-RESISTANCE RATING
 SHALL BE THE SHORTEST DURATION OBTAINED FROM THE TWO
 TESTS. WHEN EVIDENCE IS FURNISHED TO SHOW THAT THE WALL
 WAS TESTED WITH THE LEAST FIRE-RESISTANT SIDE EXPOSED
 TO THE FURNACE, SUBJECT TO ACCEPTANCE OF THE BUILDING
 OFFICIAL, THE WALL NEED NOT BE SUBJECTED TO TESTS FROM
 THE OPPOSITE SIDE.
  
 8) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2016-01-14 Cont ID  
Sent By mvaldes Date 2016-01-14 Time 19:04 Rev Time 0.00
Received By mvaldes Date 2016-01-14 Time 19:04 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2015-12-16 Cont ID  
Sent By mvaldes Date 2015-12-16 Time 13:37 Rev Time 0.00
Received By mvaldes Date 2015-12-16 Time 13:37 Sent To  
Notes
2015-12-16 14:10:06REVIEW: FBC 2014 5TH ED. NEC 2011
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 516-805-6700
 [email protected]
 ALTERNATE CONTACT
 MIKE ALBARRAN
 561-805-6746
 [email protected]
  
  
 PAGE E -1
  
 230.7 OTHER CONDUCTORS IN RACEWAY OR CABLE. CONDUCTORS
 OTHER THAN SERVICE CONDUCTORS SHALL NOT BE INSTALLED IN
 THE SAME SERVICE RACEWAY OR SERVICE CABLE.
 ( FUSED AND UNFUSED IN SAME CONDUIT. )
  
  
 PROVIDE NEW RISER DIAGRAM AND LOAD CALCULATIONS FOR
 ENTIRE ELECTRICAL SYSTEM INCLUDING EXISTING.
 SHOW PROPER GROUNDING OF SERVICE TO INCLUDE
 SUPPLEMENTAL GROUND ROD AND WATER/METAL BONDING. NEC
 250.53
 ( DON'T FORGET NEC 250.94 INTERSYSTEM BONDING. )
  
 110.16 ARC-FLASH HAZARDWARNING. ELECTRICAL EQUIPMENT,
 SUCH AS SWITCHBOARDS, PANELBOARDS, INDUSTRIAL CONTROL
 PANELS,
 METER SOCKET ENCLOSURES, AND MOTOR CONTROL CENTERS,
 THAT
 ARE IN OTHER THAN DWELLING UNITS, AND ARE LIKELY TO
 REQUIRE
 EXAMINATION, ADJUSTMENT, SERVICING, OR MAINTENANCE
 WHILE
 ENERGIZED SHALL BE FIELD MARKED TO WARN QUALIFIED
 PERSONS OF
 POTENTIAL ELECTRIC ARC FLASH HAZARDS. THE MARKING SHALL
 BE
 LOCATED SO AS TO BE CLEARLY VISIBLE TO QUALIFIED
 PERSONS BEFORE
 EXAMINATION, ADJUSTMENT, SERVICING, OR MAINTENANCE OF
 THE EQUIPMENT.
  
  
 PAGE E-2
  
 406.9 RECEPTACLES IN DAMP OR WET LOCATIONS.
 (B) WET LOCATIONS.
 (1) 15- AND 20-AMPERE RECEPTACLES IN A WET LOCATION.
 15- AND 20-AMPERE, 125- AND 250-VOLT RECEPTACLES
 INSTALLED IN
 A WET LOCATION SHALL HAVE AN ENCLOSURE THAT IS
 WEATHERPROOF
 WHETHER OR NOT THE ATTACHMENT PLUG CAP IS INSERTED. FOR
 OTHER
 THAN ONE- OR TWO-FAMILY DWELLINGS, AN OUTLET BOX HOOD
 INSTALLED
 FOR THIS PURPOSE SHALL BE LISTED, AND WHERE INSTALLED
 ON
 AN ENCLOSURE SUPPORTED FROM GRADE AS DESCRIBED IN
 314.23(B)
 OR AS DESCRIBED IN 314.23(F) SHALL BE IDENTIFIED AS
 ?EXTRA-DUTY.?
 ALL 15- AND 20-AMPERE, 125- AND 250-VOLT
 NONLOCKING-TYPE
 RECEPTACLES SHALL BE LISTED WEATHER-RESISTANT TYPE.
  
  
 NEC 410.30 LUMINAIRE SUPPORT
 SUSPENDED CEILINGS. FRAMING MEMBERS OF SUSPENDED
 CEILING SYSTEMS USED TO SUPPORT LUMINAIRES SHALL BE
 SECURELY
 FASTENED TO EACH OTHER AND SHALL BE SECURELY ATTACHED
 TO THE
 BUILDING STRUCTURE AT APPROPRIATE INTERVALS. LUMINAIRES
 SHALL
 BE SECURELY FASTENED TO THE CEILING FRAMING MEMBER BY
 MECHANICAL
 MEANS SUCH AS BOLTS, SCREWS, OR RIVETS. LISTED CLIPS
 IDENTIFIED FOR USE WITH THE TYPE OF CEILING FRAMING
 MEMBER(
 S) AND LUMINAIRE(S) SHALL ALSO BE PERMITTED.
  
  
 600.5 BRANCH CIRCUITS.
 (A) REQUIRED BRANCH CIRCUIT. EACH COMMERCIAL BUILDING
 AND EACH COMMERCIAL OCCUPANCY ACCESSIBLE TO PEDESTRIANS
 SHALL BE PROVIDED WITH AT LEAST ONE OUTLET IN AN
 ACCESSIBLE
 LOCATION AT EACH ENTRANCE TO EACH TENANT SPACE FOR SIGN
 OR
 OUTLINE LIGHTING SYSTEM USE. THE OUTLET(S) SHALL BE
 SUPPLIED
 BY A BRANCH CIRCUIT RATED AT LEAST 20 AMPERES THAT
 SUPPLIES
 NO OTHER LOAD. SERVICE HALLWAYS OR CORRIDORS SHALL NOT
 BE
 CONSIDERED ACCESSIBLE TO PEDESTRIANS.
 ( MISSING SIGN OUTLET BY SINGLE DOOR ADJACENT TO PANEL.
 )
  
 PROVIDE COMPLIANCE FOR ALL LIGHTING IN ACCORDANCE WITH
 FBC ENERGY CODE C405 ( LIGHTING CONTROLS )

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2015-11-05 Cont ID  
Sent By ppetty Date 2015-11-05 Time 10:15 Rev Time 0.00
Received By ppetty Date 2015-11-05 Time 10:15 Sent To Z
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2016-01-07 Cont ID  
Sent By pleduc Date 2016-01-07 Time   Rev Time 0.00
Received By pleduc Date 2016-01-07 Time 15:47 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2015-11-30 Cont ID  
Sent By pleduc Date 2015-11-30 Time   Rev Time 0.00
Received By pleduc Date 2015-11-30 Time 13:13 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2015-10-29 Cont ID  
Sent By pleduc Date 2015-10-29 Time   Rev Time 0.00
Received By pleduc Date 2015-10-29 Time 15:07 Sent To  
Notes
2015-10-29 16:20:39THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
 1. SHEET A 2.1, INDICATES A DOOR SCHEDULE WITH THE DOOR
 HARWARE AS "EX", EXISTING.
  
 PER NFPA 101, CHAPTER 7, 7.2.1.5.5 KEY-OPERATED LOCKS
  
 7.2.1.5.5.1 EXTERIOR DOOR ASSEMBLIES SHALL BE PERMITTED
 TO HAVE KEY-OPERATED LOCKS FROM THE EGRESS SIDE,
 PROVIDED THAT ALL OF THE FOLLOWING CRITERIA ARE MET.
  
 (1) THIS ALTERNATIVE IS PERMITTED IN CHAPTERS 11
 THROUGH 43 FOR THE SPECIFIC OCCUPANCY. ( IT IS
 PERMITTED UNDER CHAPTER 39, EXISTING BUSINESS
 OCCUPANCY)
  
 (2) A READILY VISIBLE, DURABLE SIGN IN LETTERS NOT LESS
 THAN 1 IN. HIGH ON A CONTRASTING BACKGROUND THAT READS
 AS FOLLOWS IS LOCATED ON OR ADJACENT TO THE DOOR LEAF.
 THIS DOOR TO REMAIN UNLOCKED WHEN THE BUILDING IS
 OCCUPIED.
  
 (3) THE LOCKING DEVICE IS OF A TYPE THAT IS READILY
 DISTINGUISHABLE AS LOCKED.
  
 (4) A KEY IS IMMEDIATELY AVAILABLE TO ANY OCCUPANT
 INSIDE THE BUILDING WHEN IT IS LOCKED.
  
 SHOULD ALL OF THE ABOVE NOT BE POSSIBLE:
  
 7.2.1.5.1 DOOR LEAVES SHALL BE ARRANGED TO BE OPENED
 READILY FROM THE EGRESS SIDE WHENEVER THE BUILDING IS
 OCCUPIED.
  
 7.2.1.5.3 LOCKS, IF PROVIDED, SHALL NOT REQUIRE THE USE
 OF A KEY, A TOOL, OR SPECIAL KNOWLEDGE OR EFFORT FOR
 OPERATION FROM THE EGRESS SIDE.
  
 7.2.1.5.10 A LATCH OR OTHER FASTENING DEVICE ON A DOOR
 LEAF SHALL BE PROVIDED WITH A RELEASING DEVICE THAT HAS
 AN OBVIOUS METHOD OF OPERATION AND THAT IS READILY
 OPERATED UNDER ALL LIGHTING CONDITIONS.
  
 7.2.1.5.10.2 THE RELEASING MECHANISM SHALL OPEN THE
 DOOR LEAF WITH NOT MORE THAN ONE RELEASING OPERATION.
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2016-01-28 Cont ID  
Sent By cpuell Date 2016-01-28 Time 11:19 Rev Time 0.00
Received By cpuell Date 2015-12-30 Time 14:19 Sent To  
Notes
2015-12-30 14:20:23B03

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2015-12-29 Cont ID  
Sent By ccole Date 2015-12-29 Time 08:57 Rev Time 0.00
Received By ccole Date 2015-12-28 Time 14:06 Sent To  
Notes
2015-12-28 14:06:31CCOLE'S DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-12-16 Cont ID  
Sent By lmarchan Date 2015-12-16 Time 14:23 Rev Time 0.00
Received By lmarchan Date 2015-11-25 Time 13:44 Sent To  
Notes
2015-11-25 13:45:43B06

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-11-24 Cont ID  
Sent By eschneid Date 2015-11-24 Time 13:43 Rev Time 0.00
Received By eschneid Date 2015-10-19 Time 17:39 Sent To  
Notes
2015-10-19 17:40:34B04

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2015-12-31 Cont ID  
Sent By ccole Date 2015-12-31 Time 09:12 Rev Time 0.00
Received By ccole Date 2015-12-31 Time 09:12 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2015-12-29 Cont ID  
Sent By ccole Date 2015-12-29 Time 08:55 Rev Time 0.00
Received By ccole Date 2015-12-29 Time 08:55 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2015-12-29 Cont ID  
Sent By ccole Date 2015-12-02 Time 08:55 Rev Time 0.00
Received By ccole Date 2015-12-02 Time 07:02 Sent To  
Notes
2015-12-02 07:44:131ST REVIEW 2014 MECHANICAL
 PERMIT #15100589
 12/2/15
  
 1) AS PREVIOUSLY REQUESTED IN THE FIRST REVIEW, PROVIDE
 AC COOLING AND HEATING CALCULATIONS IN ACCORDANCE WITH
 ACCA MANUAL N OR ASHRAE/ACCA STANDARD 183.
 2) HEAT LOAD SUMMARY ON SHEET M-1: A) THE SUMMARY WAS
 CALCULATED USING CARRIER SOFTWARE HOWEVER TRANE UNITS
 HAVE BEEN SELECTED. B) PROVIDE DOCUMENTATION VERIFYING
 THE PROGRAM IS ACCA OR ASHRAE APPROVED. C) THE TOTAL
 COOLING OF 6.5- TONS INDICATED IN THE SUMMARY IS MUCH
 LESS THAN THE 9-TONS OF COOLING TO BE PROVIDED TO THE
 TENANT SPACE USING THE THREE 3-TON RTU'S- PLEASE SEE
 SECTION C403.2.2 FBC-14 ENERGY CONSERVATION, EQUIPMENT
 AND SYSTEM SIZING.
 THE OUTPUT CAPACITY OF HEATING AND COOLING EQUIPMENT
 AND SYSTEMS SHALL NOT EXCEED THE LOADS CALCULATED IN
 ACCORDANCE WITH SECTION C403.2.1. A SINGLE PIECE OF
 EQUIPMENT PROVIDING BOTH HEATING AND COOLING SHALL
 SATISFY THIS PROVISION FOR ONE FUNCTION WITH THE
 CAPACITY FOR THE OTHER FUNCTION AS SMALL AS POSSIBLE,
 WITHIN AVAILABLE EQUIPMENT OPTIONS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2015-10-28 Cont ID  
Sent By ccole Date 2015-10-28 Time 10:30 Rev Time 0.00
Received By ccole Date 2015-10-28 Time 10:30 Sent To  
Notes
2015-10-28 10:42:431ST REVIEW: FBC 2014 MECHANICAL
 PERMIT #15100589
 10/28/15
  
 1) PROVIDE AC COOLING AND HEATING CALCULATIONS FOR THE
 NEW RTU'S IN COMPLIANCE WITH SECTION C403.2.1 FBC-14
 ENERGY CONSERVATION.
 2) PROVIDE ENERGY CALCULATIONS IN ACCORDANCE WITH
 SECTION C101.4.3 FBC-14 ENERGY CONSERVATION.
 3) DUCT SMOKE DETECTORS ARE REQUIRED IN THE RETURN AIR
 SYSTEMS- SEE SECTION 606.2.1 & 606.2,.2 FBC-14
 MECHANICAL.
 4) WIND LOAD TIE DOWN ENGINEERING IS REQUIRED FOR
 ATTACHING THE RTU'S AND CURBS TO THE STRUCTURE- REFER
 TO SECTION 301.15 FBC-14 MECHANICAL.
 5) PROVIDE A CROSS-SECTION VIEW OF THE RTU AND CURB
 INDICATING THE CURB MATERIALS, ROOF PATCHING DETAILS,
 AND THE HEIGHT OF THE CURB ABOVE THE ROOF.
 6) PROVIDE A CONDENSATE DISPOSABLE PLAN SHOWING THE THE
 TYPES AND SIZES OF CONDENSATE PIPING, PIPING RUNS,
 PIPING SUPPORT, DISCHARGE LOCATIONS, AND PIPE
 PROTECTION FROM UV DEGRADATION.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2015-10-21 Cont ID  
Sent By gjohnson Date 2015-10-21 Time 16:43 Rev Time 0.00
Received By gjohnson Date 2015-10-21 Time 16:43 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date 2016-01-27 Cont ID  
Sent By eschneid Date 2016-01-27 Time 12:03 Rev Time 2.00
Received By eschneid Date 2016-01-27 Time 12:03 Sent To PC
Notes
2016-01-27 15:34:45PASSED
  
 1) PRIOR TO THE FIRST INSPECTION, A PERMIT TO RESTRIPE
 THE PARKING LOT SHALL BE SUBMITTED. THE PERMIT PLAN SET
 SHALL INCLUDE THE ADA PARKING SPACES, THE ACCESSIBLE
 WALKWAY ALONG THE DOORS ACCESSING THE PARKING LOT, THE
 DUMPSTER LOCATION AND LANDSCAPE AREAS AS APPROVED BY
 PLANNING STAFF. THE CURBING AND STRIPING SHOWN ON THE
 ISSUED PARKING LOT PERMIT SHALL BE COMPLETED PRIOR TO
 THE FINAL (104) INSPECTION/CERTIFICATE OF COMPLETION OF
 THE VANILLA BOX PERMIT OR CERTIFICATE OF OCCUPANCY FOR
 THE SPACE, WHICHEVER FIRST OCCURS.
  
 2) IN ORDER TO MITIGATE THE REQUIRED LANDSCAPING ALONG
 DIXIE HIGHWAY THAT WAS REMOVED AS PART OF PERMIT
 11050756 AND NOT REPLACED AS PART OF EXPIRED PERMIT
 11100171, A LANDSCAPE PERMIT, WITH A LANDSCAPE PLAN
 APPROVED BY PLANNING STAFF, SHALL BE SUBMITTED AND BE
 ISSUED PRIOR TO THE FINAL (104) INSPECTION/CERTIFICATE
 OF COMPLETION OF THE VANILLA BOX PERMIT. THE LANDSCAPE
 WORK SHALL BE COMPLETED PRIOR TO A CERTIFICATE OF
 OCCUPANCY FOR THE BUILIDNG.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.
  

Review Stop Z ZONING
Rev No 2 Status F Date 2015-12-17 Cont ID  
Sent By eschneid Date 2015-12-17 Time 11:06 Rev Time 0.00
Received By eschneid Date 2015-12-17 Time 11:06 Sent To  
Notes
2015-12-17 11:08:04FAILED
  
 COMMENTS FROM PREVIOUS REVIEW STILL APPLY. IT IS ZONING
 STAFF UNDERSTANDING THAT A PARKING PLAN WILL BE
 SUBMITTED WITH THE NEXT SUBMITTAL. ZONING WILL PERFORM
 ITS REVIEW AT THAT TIME.
  
 THIS DOES NOT COUNT AS A ZONING REVIEW CYCLE.
  

Review Stop Z ZONING
Rev No 1 Status F Date 2015-11-24 Cont ID  
Sent By eschneid Date 2015-11-24 Time 08:54 Rev Time 0.25
Received By eschneid Date 2015-11-24 Time 08:54 Sent To  
Notes
2015-11-24 09:03:48FAILED
  
 1) PRIOR TO ZONING APPROVAL OF THIS PERMIT, A STRIPING
 PLAN FOR THE PARKING LOT SHALL BE SUBMITTED. PLEASE
 NOTE THAT IF THE ULTIMATE BUILD-OUT OF THE SPACE WILL
 TRIGGER 50% OF THE BUILDING VALUE WITHIN A ONE-YEAR
 PERIOD, THE PARKING AREA SHALL BE BROUGHT INTO
 CONFORMITY WITH THE LANDSCAPE CODE. ADDITIONALLY, AT
 LEAST ONE TREE HAS BEEN REMOVED FROM THE PARKING LOT
 WITHOUT THE APPROVAL OF A TREE ALTERATION PERMIT AND
 THUS SHALL BE REPLACED. THE STRIPING PERMIT SHALL BE
 COMPLETED PRIOR TO A CERTIFICATE OF OCCUPANCY FOR THE
 SPACE.
  
 2) THE REQUIRED LANDSCAPING ALONG DIXIE HIGHWAY THAT
 WAS REMOVED AS PART OF PERMIT 11050756 AND NOT REPLACED
 AS PART OF EXPIRED PERMIT 11100171 SHALL BE REPLACED AS
 PART OF THIS PERMIT (AND SHALL BE SHOWN ON THE PERMIT)
 OR AS A SEPARATE LANDSCAPE PERMIT THAT IS SUBMITTED
 PRIOR TO ZONING APPROVAL OF THIS PERMIT. THE LANDSCAPE
 WORK SHALL BE COMPLETED PRIOR TO A CERTIFICATE OF
 COMPLETION FOR THIS PERMIT.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.
  
  