Plan Review Details - Permit 15100522
Plan Review Stops For Permit 15100522
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-02-03 Cont ID  
Sent By jwitmer Date 2016-02-03 Time 07:30 Rev Time 0.00
Received By jwitmer Date 2016-02-03 Time 07:14 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2015-10-28 Cont ID  
Sent By jwitmer Date 2015-10-28 Time 11:01 Rev Time 0.00
Received By jwitmer Date 2015-10-28 Time 10:36 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-02-16 Cont ID  
Sent By rlecky Date 2016-02-16 Time 11:05 Rev Time 0.00
Received By rlecky Date 2016-02-16 Time 10:52 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2015-11-13 Cont ID  
Sent By dharvey Date 2015-11-13 Time 08:47 Rev Time 0.00
Received By dharvey Date 2015-11-13 Time 08:39 Sent To I
Notes
2015-11-13 08:47:09RELOCATED WORK IS CONSIDERED NEW AND REQUIRES
 COMPLIANCE WITH THE CURRENT EDITION OF THE GOVERNING
 CODES
 PROVIDE PANEL SCHEDULES FOR RELOCATED PANELS INDICATING
 WHAT IS TO REMAIN OR BE REMOVED
 ABANDONED CIRCUITS TO BE IDENTIFIED AND REMOVED
 PROVIDE WIRING ONE LINE WITH WIRE SIZES FOR PANELS,
 TRANSFORMER, GES CONNECTIONS ()COMPLETE DRAWINGS)
 UNABLE TO COMPLETE REVIEW, PLANS NOT COMPLETE.
  
 DOUG HARVEY
 [email protected]
 564-805-6740

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2016-01-26 Cont ID  
Sent By pleduc Date 2016-01-26 Time   Rev Time 0.00
Received By pleduc Date 2016-01-26 Time 14:24 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2015-10-19 Cont ID  
Sent By pleduc Date 2015-10-19 Time   Rev Time 0.00
Received By pleduc Date 2015-10-19 Time 12:04 Sent To  
Notes
2015-10-19 12:24:31THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 1. THE NATURE OF THE REMODEL REQUIRES AN EVALUATION OF
 THE FIRE ALARM AND SPRINKLER SYSTEM FOR CODE COVERAGE
 AND COMPLIANCE. ANY REMOVAL AND/OR CONSTRUCTION OF
 WALLS REQUIRE AN EVALUATION.
 THE LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR FIRE
 SPRINKLER SHALL REMAIN ACTIVE THROUGHOUT THE
 CONSTRUCTION PERIOD.
 ANY AND ALL WORK ON THE FIRE ALARM AND FIRE SPRINKLER
 SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP DRAWINGS AND
 BY CERTIFIED LIFE SAFETY CONTRACTORS.
 ANY TIME THAT WORK ON THE LIFE SAFETY SYSTEMS,
 SPRINKLER AND/OR FIRE ALARM, EXCEEDS 4 HOURS, A FIRE
 WATCH SHALL BE IMPLEMENTED AND MAINTAINED UNTIL FULL
 AND COMPLETE PROTECTION IS RETURNED.
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2016-02-24 Cont ID  
Sent By ccole Date 2016-02-24 Time 07:30 Rev Time 0.00
Received By ccole Date 2016-02-23 Time 12:51 Sent To  
Notes
2016-02-23 12:51:21RESUB ROUTED TO CCOLE

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-02-19 Cont ID  
Sent By shill Date 2016-02-19 Time 16:30 Rev Time 0.00
Received By shill Date 2016-01-21 Time 09:13 Sent To  
Notes
2016-01-22 09:13:52B15

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-11-22 Cont ID  
Sent By cpuell Date 2015-11-22 Time 11:16 Rev Time 0.00
Received By cpuell Date 2015-10-15 Time 16:21 Sent To  
Notes
2015-10-15 16:22:01B06

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2016-02-24 Cont ID  
Sent By ccole Date 2016-02-24 Time 07:29 Rev Time 0.00
Received By ccole Date 2016-02-24 Time 07:29 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2016-02-01 Cont ID  
Sent By ccole Date 2016-02-01 Time 16:05 Rev Time 0.00
Received By ccole Date 2016-02-01 Time 16:05 Sent To  
Notes
2016-02-01 16:10:142ND REVIEW: 2014 MECHANICAL
 PERMIT #15100522
 2/1/16
  
 1) THE ORIGINAL SET OF MECHANICAL PLANS WHICH WERE
 APPROVED ON 10/28/15 HAVE BEEN VOIDED AND NEW PLANS
 HAVE BEEN SUBMITTED TO REPLACE THEM. PLEASE NOTE THERE
 WAS NO NEW M1.1 SUBMITTED TO REPLACE THE OLD VOIDED
 SHEET.
 2) PLEASE PROVIDE A NEW DUCT LAYOUT PLAN FOR THE AREA
 ON THE NORTH SIDE OF THE SPACE THAT WAS DEMOLISHED,
 3) PLEASE PROVIDE EITHER DETAILS OR NOTES ON THE PLAN
 TO CLARIFY HOW ACCESS WILL BE PROVIDED FOR THE FIRE
 DAMPERS AND THE RELOCATED VAV BOXES ABOVE THE CEILINGS.
 4) PROVIDE AN AIR DEVICE SCHEDULE.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2015-10-28 Cont ID  
Sent By ccole Date 2015-10-28 Time 12:37 Rev Time 0.00
Received By ccole Date 2015-10-28 Time 12:37 Sent To  
Notes
***NONE***