Plan Review Details - Permit 15100422
| Plan Review Stops For Permit 15100422 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2015-12-21 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2015-12-21 |
Time |
17:52 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2015-12-21 |
Time |
17:51 |
Sent To |
|
|
| Notes |
| 2015-12-21 17:53:48 | 1ST REVIEW: FBC 2014 5TH ED. NEC 2011 | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 516-805-6700 | | | [email protected] | | | ALTERNATE CONTACT | | | MIKE ALBARRAN | | | 561-805-6746 | | | [email protected] | | | | | | | | | COMMENTS WERE PROPERLY ADRESSED AND MASTER PERMIT | | | NUMBER 15060045 WAS USED IN ORDER TO DO SO. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2015-10-26 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-10-26 |
Time |
19:58 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-10-26 |
Time |
19:39 |
Sent To |
I |
|
| Notes |
| 2015-10-26 20:03:22 | THE PLANS FOR THE ABOVE MENTIONED PERMIT APPLICATION | | | HAVE BEEN REVIEWED FOR COMPLIANCE WITH THE ???2011 | | | EDITION OF THE NEC, (NATIONAL ELECTRICAL CODE); THE 5TH | | | EDITION OF THE FBC, (FLORIDA BUILDING CODE) AS | | | APPLICABLE AND BELOW ARE THE DEFICIENCIES NOTED. | | | 1. YOU SHALL SUBMIT ELECTRICAL SPECIFICATIONS FOR THE | | | PROPOSED UNIT. | | | 2. YOU SHALL PROVIDE A FEEDER DIAGRAM AS REQUIRED IN | | | NEC 215.5. THIS SHALL INCLUDE SITE SPECIFIC LOAD CALCS | | | AND CONDUCTOR SIZING AS PER NEC 440. | | | 3. YOU SHALL PROVIDE A SITE PLAN SHOWING THE LOCATION | | | OF THE VARIOUS ELECTRICAL COMPONENTS OF THE UNITS. | | | 4. KEEP IN MIND THAT NEC 210.63 REQUIRES THAT THERE BE | | | A 15 -20 AMP GFI OUTLET WITHIN 25? OF THE CONDENSING | | | UNIT. | | | THE PLANS SHALL BE REVISED TO ADDRESS THE HEREIN | | | MENTIONED ITEMS; ONCE CORRECTED SHALL BE RESUBMITTED | | | FOR ANOTHER REVIEW. WHEN RESUBMITTING, YOU ARE REQUIRED | | | TO PROVIDE A RESPONSE LETTER ADDRESSING EACH ITEM ALONG | | | WITH THE STANDARD CITY RE-SUBMITTAL FORM. PLEASE, | | | ADDITIONALLY, INSERT CORRECTED PAGES INTO THE SUBMITTAL | | | AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR | | | COMPARISON. CLOUDING THE CHANGES WILL BE GREATLY | | | APPRECIATED. | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | | CONTACT ME DIRECTLY. | | | | | | THANK YOU, | | | MIKE ALBARRAN | | | ELECTRICAL PLANS EXAMINER | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2015-12-11 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2015-12-28 |
Time |
08:19 |
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2015-12-11 |
Time |
|
Sent To |
PC |
|
| Notes |
| 2015-12-11 16:06:02 | PASSED WITH PROVISO: IF BLDG IS SPRINKLED AND/OR | | | ALARMED, SPRINKLERS AND NOTIFICATION APPLIANCES MAY BE | | | REQUIRED IN COOLERS. (EVALUATE) | | | GJT |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2015-12-23 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-10-26 |
Time |
20:11 |
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2015-10-20 15:41:06 | PASSED WITH PROVISO: "IF BLDG IS SPRINKLERED AND/OR | | | ALARMED, SPRINKLERS AND/OR NOTIFICATION APPLIANCES MAY | | | BE REQUIRED IN FREEZER. (EVALUATE) GJT | | | | | | SENT TO MECHANICAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-12-23 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2015-12-23 |
Time |
08:19 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2015-12-23 |
Time |
08:19 |
Sent To |
FIRE |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-10-22 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-10-22 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-10-13 |
Time |
15:17 |
Sent To |
|
|
| Notes |
| 2015-10-26 20:08:37 | 10/26/15 FAILED ELECTRICAL REVIEW. CONTRACTOR NOTIFIED | | | VIA EMAIL. SENT TO SMALL DENIED BIN "A". MA |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2015-12-23 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2015-12-23 |
Time |
07:22 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2015-12-23 |
Time |
07:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2015-10-22 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-10-22 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-10-22 |
Time |
10:01 |
Sent To |
|
|
| Notes |
| 2015-10-22 10:12:10 | 1ST REVIEW: FBC 2014 MECHANICAL | | | PERMIT #15100422 | | | 10/22/15 | | | | | | 1) THE COOLER AND FREEZER DIMENSIONS SHOWN IN THE PLAN | | | VIEW ARE INCORRECT: PLEASE PROVIDE CORRECT DIMENSIONS. | | | 2) PROVIDE COMPLETE EQUIPMENT SCHEDULES FOR THE | | | CONDENSERS AND EVAPORATOR INDICATING MAKES AND MODELS, | | | REFRIGERANT TYPES AND QUANTITIES, PHYSICAL AND | | | ELECTRICAL DATA ETC. | | | 3) PROVIDE WIND LOAD TIE DOWN ENGINEERING FOR THE | | | CONDENSERS AND ROOF TOP STANDS- SECTION 301.15 FBC-14 | | | MECHANICAL. | | | 4) REFRIGERANT PIPING: INDICATE TYPES AND SIZES OF | | | PIPING AND PIPE INSULATIONS, SHOW THE PIPING RUNS, AND | | | TRHU PENETRATION FIRESTOPPING DETAILS. | | | 5) SHOW THE DISCHARGE LOCATIONS OF THE EVAPORATOR | | | CONDENSATE LINES. | | | 6) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE WALK-IN | | | BOXES. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
|