Plan Review Details - Permit 15100416
| Plan Review Stops For Permit 15100416 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2015-10-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-10-29 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-10-29 |
Time |
10:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2015-12-07 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2015-12-07 |
Time |
15:25 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2015-12-07 |
Time |
10:17 |
Sent To |
I |
|
| Notes |
| 2015-12-07 15:25:19 | RECEIVED INFORMATION ON 6 MIL PRODUCT. ATTACHING TO | | | PLANS. DH | | 2015-12-07 11:44:49 | CALLED DENNIS DAVIS, PE REGARDING SPEC SHEET ON 6 MIL | | | POLYETHYLENE FIRE RETARDANT MATERIAL. HE STATED HE | | | EMAIL THE SPEC SHEET OVER. WAITING. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2015-11-13 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2015-11-13 |
Time |
08:20 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2015-11-12 |
Time |
14:47 |
Sent To |
I |
|
| Notes |
| 2015-11-13 08:20:11 | XFORMER ORC DOES APPEAR TO BE CONNECTED TO ANYTHING. | | | PROVIDE SECONDARY CONNECTIONS AND LOADS. | | | NOTES INDICATE DEMOLITION AND STATE EQUIPMENT IS | | | EXISTING AND TO REMAIN. PLEASE EXPLAIN | | | PROVIDE ORIGINAL PERMIT NUMBER UNDER WHICH THIS WORK | | | WAS ORIGINALLY PERMITTED AND INSTALLED | | | IS THE INTENT FOR INSTALLATION, DEMOLITION OR TO | | | CORRECT UNPERMITTED WORK? | | | ALL WIRING TO MAINTAIN REQUIRED SEPARATION PER NEC 517 | | | AND 700 | | | IT APPEARS EXISTING WIRING IS BEING RE-ROUTED TO | | | PROVIDE PATIENT CARE SERVICES. ENSURE PROPER WIRING | | | METHODS | | | IS PANEL ORC ON SHEET E4-1 FED FROM XFORMER ORC? THE | | | ONE LINE DRAWING DOES NOT SO INDICATE | | | LUMINAIRES ON SHEET E3-1 HAVE FOOTNOTES "A, B, C" YET | | | THIS INFORMATION DOES SEEM TO BE AVAILABLE, PLEASE | | | EXPLAIN | | | PROVIDE LISTING OF EQUIPMENT TO SHOW SUITABILITY FOR | | | LOCATION AND USE | | | PLEASE CLARIFY WHAT IS TO BE NEW, WHAT IS TO DEMOLISHED | | | AND PROVIDE A COMPLETE DRAWING FOR "ORC" | | | REVIEW NOT COMPLETE UNTIL THESE QUESTIONS CAN BE | | | ANSWERED AND A COMPLETE DRAWING IS PROVIDED. | | | | | | DOUG HARVEY | | | [email protected] | | | 561-805-6740 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2015-10-23 |
|
|
Cont ID |
|
| Sent By |
J.Walker |
Date |
2015-10-23 |
Time |
|
Rev Time |
0.20 |
| Received By |
|
Date |
2015-10-19 |
Time |
|
Sent To |
E |
|
| Notes |
| 2015-10-23 08:30:25 | ALL LIFE SAEFTY SYSTEMS TO REMAIN FUNCTIONAL THROUGH | | | OUT PROJECT. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-12-07 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2015-12-07 |
Time |
15:25 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2015-12-04 |
Time |
09:29 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-11-13 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2015-11-13 |
Time |
08:21 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2015-10-13 |
Time |
15:09 |
Sent To |
|
|
| Notes |
|
|
|