Plan Review Details - Permit 15100389
Plan Review Stops For Permit 15100389
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-12-17 Cont ID  
Sent By rmcdouga Date 2015-12-17 Time 07:52 Rev Time 0.00
Received By rmcdouga Date 2015-12-17 Time 07:43 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2015-10-16 Cont ID  
Sent By rmcdouga Date 2015-10-16 Time 08:44 Rev Time 0.00
Received By rmcdouga Date 2015-10-16 Time 07:43 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2015-10-20 Cont ID  
Sent By albarran Date 2015-10-20 Time 08:44 Rev Time 0.00
Received By albarran Date 2015-10-20 Time 08:41 Sent To I
Notes
2015-10-20 08:46:13ACCORDING TO THE SCOPE AS DEFINED ON THE PERMIT
 APPLICATION AND THE PLANS SUBMITTED, THERE IS NO
 ELECTRICAL WORK BEING PERFORMED HERE.NOTICE TO
 INSPECTOR
 THE SCOPE OF THIS PERMIT EXCLUDES ANY ELECTRICAL WORK.
 SHALL ANY ELECTRICAL WORK BE OBSERVED, PLEASE NOTIFY
 CITY OF WEST PALM BEACH DEVELOPMENT SERVICES.
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-12-17 Cont ID  
Sent By rmcdouga Date 2015-12-17 Time 07:52 Rev Time 0.00
Received By rmcdouga Date 2015-12-11 Time 10:14 Sent To  
Notes
2015-12-14 10:14:26RESUB ROUTED TO TKLARGE

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-10-20 Cont ID  
Sent By albarran Date 2015-10-20 Time 09:03 Rev Time 0.00
Received By albarran Date 2015-10-13 Time 13:30 Sent To  
Notes
2015-10-20 09:03:0510/20/15 PASSED ALL REVIEWS AND IS READY TO BE ISSUED.
 CONTRACTOR NOTIFIED VIA PHONE IN LIEU OF MISSING EMAIL
 ADDRESS. SENT TO SMALL READY BIN "T". MA
2015-10-13 14:40:27POOL BOX

Review Stop P PLUMBING
Rev No 2 Status P Date 2015-12-17 Cont ID  
Sent By tklarge Date 2015-12-17 Time 06:23 Rev Time 0.00
Received By tklarge Date 2015-12-17 Time 05:55 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2015-10-20 Cont ID  
Sent By tklarge Date 2015-10-20 Time 05:29 Rev Time 0.00
Received By tklarge Date 2015-10-20 Time 03:56 Sent To  
Notes
2015-10-20 04:58:121) THE PERMIT APPLICATION NOTES " POOL FILTER
 CHANGEOUT" YET THE PLANS SHOW A NEW SALT SYSTEM IS
 BEING ADDED FOR THE POOL AND ALSO A PH FEEDER FOR THE
 SPA. UPDATE THE DESCRIPTION OF WORK ON THE APPLICATION
 TO INCLUDE THE SALT SYSTEM AND THE PH FEEDER SYSTEM.
 THE JOB VALUE SHALL ALSO BE ADJUSTED TO INCLUDE THESE
 ITEMS. WPB AMEND. TO THE FBC SEC. 109.3, 105.3.1.
 2) SUBMIT MANUFACTURER'S SPECIFICATIONS/INSTALLATION
 MANUALS FOR THE CARTRIDGE FILTERS AND ALSO FOR THE SALT
 SYSTEM FOR THE POOL.WPB AMEND. TO FBC SEC. 107.2.1.
 3) THE PLANS SHOW A NEW STENNER PH FEEDER FOR THE SPA.
 SUBMIT MANUF. SPEC SHETS / INSTALLATION MANUAL. WPB
 AMEND. TO FBC SEC. 107.2.1.
 4) THE SALT SYSTEM AND THE PH FEEDER SYSTEM/TANKS ARE
 SHOWN ON THE PIPING DIAGRAM BUT NOT ON THE PLAN VIEW.
 CLARIFY.
 5) THE MAXIMUM FILTRATION RATE IN GALLONS PER MINUTE
 PER SQUARE FOOT OF FILTER AREA FOR THE CARTRIDGE
 FILTERS SHALL BE 0.375 PER THE 2014 FBC
 SEC.454.1.6.5.5.1.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  