Plan Review Details - Permit 15100337
Plan Review Stops For Permit 15100337
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-10-21 Cont ID  
Sent By rmcdouga Date 2015-10-21 Time 07:31 Rev Time 0.00
Received By rmcdouga Date 2015-10-21 Time 07:30 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-10-13 Cont ID  
Sent By rmcdouga Date 2015-10-13 Time 18:17 Rev Time 0.00
Received By rmcdouga Date 2015-10-13 Time 18:05 Sent To  
Notes
2015-10-13 18:25:12PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE RAS 117 CALCULATIONS ARE INCORRECT. THE CORNER
 REQUIRES FASTENER SPACING OF 4" OC @ LAPS AND FOUR (4)
 EQUALLY SPACED STAGGERED ROWS @4" OC IN THE CENTER OF
 THE SHEET. THE ENGINEERING THAT WAS SUBMITTED HAS ONLY
 (3) ROWS IN THE CENTER OF THE SHEET. FBC 107.2.1

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-10-21 Cont ID  
Sent By rmcdouga Date 2015-10-21 Time 07:31 Rev Time 0.00
Received By rmcdouga Date 2015-10-19 Time 12:56 Sent To  
Notes
2015-10-20 12:56:42RESUB ROUTED TO RMCDOUGAL

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-10-13 Cont ID  
Sent By rmcdouga Date 2015-10-13 Time 18:18 Rev Time 0.00
Received By rmcdouga Date 2015-10-09 Time 09:32 Sent To  
Notes
2015-10-13 09:32:40REVISION ROUTED TO RMCDOUGAL