| Plan Review Stops For Permit 15091280 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2015-12-15 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-12-15 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-12-15 |
Time |
14:22 |
Sent To |
|
|
| Notes |
| 2015-12-15 14:40:06 | BUILDING REVIEW APPROVED WITH PROVISO: | | | | | | 1- ENERGY CALCULATIONS SUBMITTED; | | | A)PROVIDE THE INSPECTION CHECKLIST AS REQUIRED BY SEC. | | | R405.4.2 OF FBC-ENERGY CONSERVATION, 5TH EDITION | | | (2014). | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2015-12-11 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-12-11 |
Time |
09:19 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-12-11 |
Time |
09:19 |
Sent To |
E |
|
| Notes |
| 2015-12-11 09:44:45 | RESIDENTIAL (R3) GARAGE CONVERSION TO FAMILY ROOM | | | REVIEW COMMENTS. | | | CODE: FBC 5TH EDITION (2014). | | | | | | NOTE: BUILDING REVIEW MAY BE APPROVED ONCE I GET THE | | | IMPACT FEES STAMPED PLANS WITH COPY OF PAID RECEIPT (IF | | | REQUIRED) AND WITH THE INFORMATION REQUESTED FOR THE | | | ENERGY CALCULATIONS BELOW. PLEASE CONTACT JULIO WHEN | | | THIS INFORMATION IS PROVIDED TO FINISH MY REVIEW. | | | | | | | | | 1- CONVERSION OF GARAGE TO FAMILY ROOM REQUIRES IMPACT | | | FEES ASSESSMENT. BRING PLANS TO PALM BEACH COUNTY (2300 | | | N. JOG RD.) FOR IMPACT FEES ASSESSMENT. BRING BACK | | | COUNTY STAMPED PLANS AND COPY OF PAID RECEIPT IF FEES | | | ARE DUE. COUNTY IMPACT FEE ORDINANCE OF THE UNIFIED | | | LAND DEVELOPMENT CODE. | | | | | | 2-ENERGY CALCULATIONS SUBMITTED; | | | A)OWNER/AGENT TO CERTIFY CODE COMPLIANCE AT THE BOTTOM | | | OF THE FORM AS REQUIRED BY SEC. R103.1.1.2 OF | | | FBC-ENERGY CONSERVATION, 5TH EDITION (2014). | | | | | | B) PROVIDE COMPLETE INFORMATION ON TOP OF FORM, | | | INCLUDING OWNER'S NAME, BUILDER'S NAME, PERMITTING | | | OFFICE AND JURISDICTION NUMBER. SEC. R101.5.1.1.2 OF | | | FBC-ENERGY CONSERVATION, 5TH EDITION (2014). | | | | | | C) BUILDER TO COMPLETE THE ENERGY PERFORMANCE LEVEL | | | (EPL) DISPLAY CARD. SEC. R405.4.3 OF FBC-ENERGY | | | CONSERVATION, 5TH EDITION (2014). | | | | | | D) BUILDER TO COMPLETE THE COMPLETE INSPECTION | | | CHECKLIST AS REQUIRED BY SEC. R405.4.2 OF FBC-ENERGY | | | CONSERVATION, 5TH EDITION (2014). | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-11-06 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-11-06 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-11-06 |
Time |
07:32 |
Sent To |
|
|
| Notes |
| 2015-11-06 14:45:54 | RESIDENTIAL (R3) ALTERATION/ADDITION BUILDING REVIEW | | | COMMENTS. | | | CODE: FBC 5TH EDITION (2014). | | | | | | 1- A) PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. | | | R101.4.3 OF FBC-ENERGY CONSERVATION, 5TH EDITION | | | (2014). | | | NOTE: ENERGY CALCULATIONS WILL NOT BE REQUIRED IF THE | | | HOUSE IS A TRUE CONTRIBUTING HISTORIC HOUSE. I AM | | | WAITING FROM THE HISTORIC PRESERVATION PLANNER RESPONSE | | | REGARDING THE HISTORIC CONTRIBUTION OF THE HOUSE. | | | | | | 11/9/15 RECEIVED CONFIRMATION FROM THE HISTORIC | | | PRESERVATION PLANNER: THIS IS NOT A CONTRIBUTING | | | HISTORIC HOUSE. | | | | | | B) PLEASE PROVIDE INFORMATION ON PLANS AND ENERGY | | | CALCULATIONS AS REQUIRED BY SEC. R103.2 OF FBC-ENERGY | | | CONSERVATION, 5TH EDITION (2014). SPECIFY INSULATION ON | | | WALLS, CEILINGS, ETC. | | | | | | 2- THE PROPOSED USE OF THE GARAGE IS NOT CLEAR. | | | ACCORDING TO THE PLANS SUBMITTED THE GARAGE USE IS NOT | | | LONGER AS A GARAGE BUT AS HABITABLE SPACE. THE SPACE IS | | | GOING TO BE AIR CONDITIONED AND LOOKS MORE LIKE AN | | | ENTERTAINMENT ROOM THAN A GARAGE. ALSO, THE SPACE IS | | | NOT FUNCTIONAL AS A GARAGE BECAUSE THE GARAGE DOOR IS | | | PROPOSED TO BE INOPERABLE. PLAN REVIEW CAN NOT BE | | | PROPERLY DONE IF THE PROPOSED PLANS DON'T MATCH THE | | | PROPOSED USE. IF THE INTENTION IS TO HAVE AN | | | ENTERTAINMENT ROOM, THEN CLEARLY IDENTIFY ROOM AS SO. | | | SEC. 107.2.1 CITY AMENDMENTS. | | | IF THE ROOM STAYS AS GARAGE, THEN IT NEEDS TO CLEARLY | | | SHOW USE AS A GARAGE. NOTE: THE A/C WOULDN'T COMPLY | | | BECAUSE RETURN AIR CAN'T BE TAKEN FROM THE GARAGE. | | | ALSO, TAKE INTO ACCOUNT THAT ENERGY CALCULATIONS MAY | | | NOT PASS BASED ON THE AMOUNT OF GLAZING IN THE GARAGE | | | AND THE INFILTRATION THRU THE GARAGE DOOR. | | | | | | 3- SHEET A-1: STRUCTURAL NOTES REFERENCE THE 2010 CODE | | | AND SEC. 1609. THE CURRENT CODE IS THE FBC-RESIDENTIAL, | | | 5TH EDITION (2014) AND THE CORRECT SEC. IS R301. REVISE | | | AS REQUIRED . SEC. 107.2.1 CITY AMENDMENTS. | | | | | | 4- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED FAC | | | 61G20-3.002(33) FOR: | | | A) FRENCH DOOR TRANSOM MULLION AS SHOWN ON PLANS. AND, | | | CLEARLY IDENTIFY MULLION SIZE TO VERIFY THE DESIGN | | | PRESSURES. SEC. R301 OF FBC-RESIDENTIAL, 5TH EDITION | | | (2014). | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2015-12-15 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-12-15 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-12-15 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2015-12-15 14:16:06 | 3RD REVIEW: FBC 2014 5TH ED. NEC 2011/RESIDENTIAL | | | | | | PROVISIONALLY APPROVED: | | | | | | FBC- 107.3.5.3 ? PROVIDE SMOKE DETECTORS PURSUANT TO | | | FBC-R 314.3.1 AS REQUIRED FOR NEW DWELLINGS. | | | FBC-R 315.1 ? PROVIDE CARBON MONOXIDE ALARMS WITHIN 10 | | | FEET OF EACH SLEEPING ROOM. | | | NEC 210.52(A)(1)&(2) OUTLET SPACING, IT APPEARS SOME | | | POINTS ALONG THE WALL EXCEED 6? FROM AN OUTLET | | | NEC 210.12B - OUTLETS TO BE AFCI PROTECTED. | | | FBCRE3902.12 ARC-FAULT CIRCUIT-INTERRUPTER PROTECTION. | | | ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, | | | 15- AND 20-AMPERE OUTLETS INSTALLED IN FAMILY ROOMS, | | | DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, | | | BEDROOMS, SUNROOMS, RECREATIONS ROOMS, CLOSETS, | | | HALLWAYS AND SIMILAR ROOMS OR AREAS SHALL BE PROTECTED | | | BY A COMBINATION TYPE ARC-FAULT CIRCUIT INTERRUPTER | | | INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT. | | | FBCRE4002.14 TAMPER-RESISTANT RECEPTACLES. | | | IN AREAS SPECIFIED IN SECTION E3901.1, 125-VOLT, 15- | | | AND 20-AMPERE RECEPTACLES SHALL BE LISTED | | | TAMPER-RESISTANT RECEPTACLES. | | | (2) WALL SPACE. AS USED IN THIS SECTION, A WALL SPACE | | | SHALL | | | INCLUDE THE FOLLOWING: | | | (1) ANY SPACE 600 MM (2 FT) OR MORE IN WIDTH (INCLUDING | | | SPACE MEASURED AROUND CORNERS) AND UNBROKEN ALONG | | | THE FLOOR LINE BY DOORWAYS AND SIMILAR OPENINGS, | | | FIREPLACES, | | | AND FIXED CABINETS | | | (2) THE SPACE OCCUPIED BY FIXED PANELS IN EXTERIOR | | | WALLS, | | | EXCLUDING SLIDING PANELS | | | (3) THE SPACE AFFORDED BY FIXED ROOM DIVIDERS, SUCH AS | | | FREESTANDING BAR-TYPE COUNTERS OR RAILINGS | | | | | | | | | STEVEN KENNEDY, CBO | | | CHIEF PLANS EXAMINER | | | (561) 805-6710 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2015-12-14 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2015-12-14 |
Time |
08:36 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2015-12-14 |
Time |
08:36 |
Sent To |
|
|
| Notes |
| 2015-12-14 08:59:51 | 1ST REVIEW: FBC 2014 5TH ED. NEC 2011/RESIDENTIAL | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 516-805-6700 | | | [email protected] | | | ALTERNATE CONTACT | | | PHIL PETTY | | | 561-805-6742 | | | [email protected] | | | | | | | | | FBC- 107.3.5.3 ? PROVIDE SMOKE DETECTORS PURSUANT TO | | | FBC-R 314.3.1 AS REQUIRED FOR NEW DWELLINGS. | | | FBC-R 315.1 ? PROVIDE CARBON MONOXIDE ALARMS WITHIN 10 | | | FEET OF EACH SLEEPING ROOM. | | | NEC 210.52(A)(1)&(2) OUTLET SPACING, IT APPEARS SOME | | | POINTS ALONG THE WALL EXCEED 6? FROM AN OUTLET | | | NEC 210.12B - OUTLETS TO BE AFCI PROTECTED. | | | FBCRE3902.12 ARC-FAULT CIRCUIT-INTERRUPTER PROTECTION. | | | ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, | | | 15- AND 20-AMPERE OUTLETS INSTALLED IN FAMILY ROOMS, | | | DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, | | | BEDROOMS, SUNROOMS, RECREATIONS ROOMS, CLOSETS, | | | HALLWAYS AND SIMILAR ROOMS OR AREAS SHALL BE PROTECTED | | | BY A COMBINATION TYPE ARC-FAULT CIRCUIT INTERRUPTER | | | INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT. | | | FBCRE4002.14 TAMPER-RESISTANT RECEPTACLES. | | | IN AREAS SPECIFIED IN SECTION E3901.1, 125-VOLT, 15- | | | AND 20-AMPERE RECEPTACLES SHALL BE LISTED | | | TAMPER-RESISTANT RECEPTACLES. | | | (2) WALL SPACE. AS USED IN THIS SECTION, A WALL SPACE | | | SHALL | | | INCLUDE THE FOLLOWING: | | | (1) ANY SPACE 600 MM (2 FT) OR MORE IN WIDTH (INCLUDING | | | SPACE MEASURED AROUND CORNERS) AND UNBROKEN ALONG | | | THE FLOOR LINE BY DOORWAYS AND SIMILAR OPENINGS, | | | FIREPLACES, | | | AND FIXED CABINETS | | | (2) THE SPACE OCCUPIED BY FIXED PANELS IN EXTERIOR | | | WALLS, | | | EXCLUDING SLIDING PANELS | | | (3) THE SPACE AFFORDED BY FIXED ROOM DIVIDERS, SUCH AS | | | FREESTANDING BAR-TYPE COUNTERS OR RAILINGS | | 2015-12-11 14:04:53 | NEW REVISED DRAWINGS SUBMITTED. JG. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2015-11-03 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2015-11-03 |
Time |
10:04 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2015-11-03 |
Time |
10:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2015-10-01 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2015-10-01 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2015-10-01 |
Time |
10:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2015-12-15 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-12-15 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-12-15 |
Time |
14:25 |
Sent To |
|
|
| Notes |
| 2015-12-15 14:25:40 | IMPACT FEES RE-SUBMITTAL. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-12-14 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2015-12-14 |
Time |
10:07 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2015-12-01 |
Time |
10:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-11-06 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-11-06 |
Time |
17:27 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-10-02 |
Time |
07:50 |
Sent To |
|
|
| Notes |
| 2015-10-02 10:00:07 | R07 | | 2015-10-02 07:50:59 | 10/2 TO INCOMING | | | | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
P |
Date |
2015-12-15 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-12-15 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-12-15 |
Time |
14:52 |
Sent To |
|
|
| Notes |
| 2015-12-15 14:53:52 | $180.65 PAID. MU-2015-028838. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2015-12-11 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-12-11 |
Time |
14:05 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-12-11 |
Time |
14:05 |
Sent To |
|
|
| Notes |
| 2015-12-11 14:05:59 | 1- CONVERSION OF GARAGE TO FAMILY ROOM REQUIRES IMPACT | | | FEES ASSESSMENT. BRING PLANS TO PALM BEACH COUNTY (2300 | | | N. JOG RD.) FOR IMPACT FEES ASSESSMENT. BRING BACK | | | COUNTY STAMPED PLANS AND COPY OF PAID RECEIPT IF FEES | | | ARE DUE. COUNTY IMPACT FEE ORDINANCE OF THE UNIFIED | | | LAND DEVELOPMENT CODE. | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2015-11-06 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-11-06 |
Time |
16:13 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-11-06 |
Time |
16:13 |
Sent To |
|
|
| Notes |
| 2015-11-06 16:15:06 | AFTER CLARIFICATION OF THE USED OF GARAGE AS GARAGE OR | | | ENTERTAINMENT CENTER IMPACT FEES ASSESSMENT MAY BE | | | REQUIRED. SEE BUILDING REVIEW COMMENTS. JG. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2015-12-11 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-12-11 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-12-11 |
Time |
15:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2015-11-06 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-11-06 |
Time |
17:27 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-11-06 |
Time |
17:27 |
Sent To |
|
|
| Notes |
| 2015-11-06 17:31:39 | RESIDENTIAL (R3) ALTERATION/ADDITION MECHANICAL REVIEW | | | COMMENTS. | | | CODE: FBC 5TH EDITION (2014). | | | | | | 1- A/C RETURN AIR CAN'T BE TAKEN FROM THE GARAGE. SEC. | | | 1602.2 OF FBC-RESIDENTIAL, 5TH EDITION (2014). | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2015-12-07 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2015-12-07 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2015-12-07 |
Time |
10:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2015-10-13 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2015-10-13 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2015-10-13 |
Time |
11:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2015-10-01 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2015-10-01 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2015-10-01 |
Time |
10:34 |
Sent To |
B |
|
| Notes |
|
|