Plan Review Details - Permit 15091221
| Plan Review Stops For Permit 15091221 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2015-11-30 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2015-12-03 |
Time |
13:53 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-11-30 |
Time |
17:25 |
Sent To |
|
|
| Notes |
| 2015-11-30 17:32:01 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. PLAN STATES THAT NON IMPACT WINDOWS WERE INSTALLED | | | (AND OUR RECORDS INDICATE THAT THE WINDOWS ARE NON | | | IMPACT), AND PLAN ACKNOWLEDGES THAT IMPACT PROTECTION | | | IS REQUIRED. HOWEVER, IMPACT WINDOW PRODUCT APPROVALS | | | WERE SUBMITTED. THIS DOES NOT APPEAR CONSISTENT WITH | | | THE WORK DONE. DO YOU PROPOSE TO REMOVE THE NON IMPACT | | | WINDOWS AND INSTALL IMPACT? | | | | | | IF WINDOWS ARE NON IMPACT AND ARE TO REMAIN, PROVIDE | | | PRODUCT APPROVALS, FAC9N-3. ALSO PROVIDE PRODUCT | | | APPROVALS FOR THE SHUTTERS REFERRED TO ON THE PLAN. | | | | | | 2. FOR THE SHUTTERS, COMPLETE THE SAMPLE INSTALLATION | | | SCHEDULE OR PROVIDE ALL INFORMATION TO SHOW CODE | | | COMPLIANCE IN ANOTHER FORMAT, FBC*106, FBC R301, | | | FBC1609. TWO SETS REQUIRED. THIS FORM IS AVAILABLE IN | | | THE LOBBY OR ON THE INTERNET AT | | | | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | | 2013/09/SCHEDULE_FOR_INSTALLATION.PDF | | | | | | 3. IT IS NOT CLEAR WHAT AFFECT, IF ANY, ENCLOSING THE | | | PORCH HAS ON EMERGENCY EGRESS FOR SLEEPING ROOMS. | | | REVISE THE PLAN TO SHOW ROOM DESIGNATION(S) FOR THE | | | ROOM(S) ADJACENT TO THE FRONT PORCH, FBC R310. | | | ADDITIONAL INFORMATION MAY BE REQUIRED. | | | | | | 4. PLAN SHOWS TWO COLUMNS AN NO WALL WHERE THE FORMER | | | EXTERIOR WALL WAS LOCATED. REVISE PLAN TO CLARIFY; IS | | | THE WALL IN PLACE OR HAS IT BEEN REMOVED? FBC 107 | | | | | | 5. PLAN IS NOT CLEAR. A NOTE STATES THAT STRAPS ARE NOT | | | REQUIRED AS THE WALL IS INFILL ONLY, BUT THE DETAIL | | | SHOWS STRAPS. CORRELATE AND PROVIDE CALCULATIONS TO | | | SHOW THAT THE INFILL WALL WILL RESIST WIND LOADS, FBC | | | 5TH ED. 301. IF STRAPS ARE NOT UTILIZED, DETAIL SHOULD | | | SHOW WHAT IS TO HOLD THE WALL IN PLACE TO RESIST | | | POSITIVE AND NEGATIVE WIND PRESSURES. DETAIL SHOWS | | | STRAPS, LANGUAGE STATES THEY ARE NOT TO BE INSTALLED, | | | PROPOSED DESIGN NOT CLEAR. | | | | | | 6. PLAN IS NOT CLEAR; GROUND FLOOR PLAN GRAPHICALLY | | | SHOWS SUPPORTS LARGER THAN THE WALL, AND IT APPEARS | | | THAT THE SUPPORTS MAY BE NEW, REVISE PLAN TO CLARIFY, | | | FBC 107. | | | | | | 7. A NEW DOOR WAS INSTALLED WITHOUT PERMIT, SEE | | | PREVIOUS LIST, REVISE PLAN TO INCLUDE ALL WORK DONE AS | | | WELL AS ALL WORK REQUIRED TO BRING INTO COMPLIANCE. | | | PROVIDE TWO SETS OF PRODUCT APPROVAL FOR THE DOOR, | | | FAC9N-3, FBC 107, FBC 5TH. ED RESIDENTIAL 301. | | | | | | 8. PLAN STATES THAT SCOPE IS REMOVAL OF PLEXIGLASS | | | WINDOWS, INSTALLATION OF NEW WINDOWS. THE PORCH WAS | | | REBUILT, ELECTRICAL ADDED. REVISE PLAN TO BE CONSISTENT | | | WITH WORK DONE WITHOUT PERMIT. | | | | | | 9. VALUE IS TO INCLUDE ALL WORK DONE WITHOUT PERMIT, | | | FBC 109. PROVIDE A COST BREAKDOWN OF WORK TO BE | | | INCLUDED IN THIS PERMIT. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2015-10-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-10-27 |
Time |
07:24 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-10-27 |
Time |
07:24 |
Sent To |
|
|
| Notes |
| 2015-10-27 07:55:21 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FROM PREVIOUS LIST: | | | | | | 1. THIS PERMIT IS TO ADDRESS A CODE VIOLATION. | | | | | | REVISE PLAN TO CLARIFY THE NATURE OF VIOLATION, PROVIDE | | | INFORMATION ABOUT THE WORK DONE WITHOUT PERMIT, AND | | | REVISE PLAN TO SHOW WHAT IS PROPOSED TO DEAL WITH THIS | | | VIOLATION, FBC 107. | | | | | | PRIOR TO PERMIT ISSUANCE, WORK SHOWN ON THE PLAN WILL | | | BE CONFIRMED WITH THE INSPECTOR WHO ISSUED THE | | | VIOLATION. | | | | | | 2ND REVIEW, PLAN SUBMITTED INCLUDES AN ENGINEER'S TITLE | | | BLOCK AND SEAL BUT NO SIGNATURE, SEE FS471. | | | | | | SCOPE IS STATED AS WINDOW REPLACEMENT. OUR RECORDS SHOW | | | THAT THIS WAS AN UNENCLOSED PORCH WITH SOME SIDING, | | | FOUR SCREEN OPENINGS AND A DOOR. THIS WAS ENTIRELY | | | RE-FRAMED, OPENINGS RE-CONFIGURED, NEW DOOR AND | | | WINDOWS, STUCCO, ELECTRICAL, HANDRAIL REMOVED. | | | | | | PROVIDE PLANS WHICH ADDRESS THE REFRAMING AND | | | CONVERSION OF AN OPEN PORCH TO A HABITABLE ROOM. PLANS | | | PROVIDED STATE THAT SCOPE IS TO "REMOVE EXISTING | | | PLEXIGLASS WINDOW COVERINGS & INSTALL NEW WINDOWS." IT | | | ALSO DEPICTS THIS AREA AS A "COVERED PORCH" BUT IT | | | APPEARS THAT THIS IS NOW HABITABLE SPACE. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-10-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-10-08 |
Time |
12:37 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-10-08 |
Time |
12:37 |
Sent To |
|
|
| Notes |
| 2015-10-08 12:39:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. THIS PERMIT IS TO ADDRESS A CODE VIOLATION. | | | | | | REVISE PLAN TO CLARIFY THE NATURE OF VIOLATION, PROVIDE | | | INFORMATION ABOUT THE WORK DONE WITHOUT PERMIT, AND | | | REVISE PLAN TO SHOW WHAT IS PROPOSED TO DEAL WITH THIS | | | VIOLATION, FBC 107. | | | | | | PRIOR TO PERMIT ISSUANCE, WORK SHOWN ON THE PLAN WILL | | | BE CONFIRMED WITH THE INSPECTOR WHO ISSUED THE | | | VIOLATION. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2015-12-03 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2015-12-03 |
Time |
09:22 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2015-12-03 |
Time |
09:19 |
Sent To |
|
|
| Notes |
| 2015-12-03 09:33:54 | 1ST REVIEW: FBC 2014 5TH ED. NEC 2011/RESIDENTIAL | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 516-805-6700 | | | [email protected] | | | ALTERNATE CONTACT | | | PHIL PETTY | | | 561-805-6742 | | | [email protected] | | | | | | | | | | | | | | | (A) GENERAL PROVISIONS. IN EVERY KITCHEN, FAMILY ROOM, | | | DINING ROOM, LIVING ROOM, PARLOR, LIBRARY, DEN, | | | SUNROOM, | | | BEDROOM, RECREATION ROOM, OR SIMILAR ROOM OR AREA OF | | | DWELLING UNITS, RECEPTACLE OUTLETS SHALL BE INSTALLED | | | IN ACCORDANCE | | | WITH THE GENERAL PROVISIONS SPECIFIED IN 210.52(A)(1) | | | THROUGH (A)(3). | | | | | | (3) BALCONIES, DECKS, AND PORCHES. BALCONIES, DECKS, | | | AND | | | PORCHES THAT ARE ACCESSIBLE FROM INSIDE THE DWELLING | | | UNIT | | | SHALL HAVE AT LEAST ONE RECEPTACLE OUTLET INSTALLED | | | WITHIN THE | | | PERIMETER OF THE BALCONY, DECK, OR PORCH. THE | | | RECEPTACLE | | | SHALL NOT BE LOCATED MORE THAN 2.0 M (61?2 FT) ABOVE | | | THE | | | BALCONY, DECK, OR PORCH SURFACE. | | | | | | 210.70 LIGHTING OUTLETS REQUIRED. LIGHTING OUTLETS | | | SHALL | | | BE INSTALLED WHERE SPECIFIED IN 210.70(A), (B), AND | | | (C). | | | (A) DWELLING UNITS. IN DWELLING UNITS, LIGHTING OUTLETS | | | SHALL BE INSTALLED IN ACCORDANCE WITH 210.70(A)(1), | | | (A)(2), | | | AND (A)(3). | | | (1) HABITABLE ROOMS. AT LEAST ONE WALL | | | SWITCH?CONTROLLED | | | LIGHTING OUTLET SHALL BE INSTALLED IN EVERY HABITABLE | | | ROOM | | | AND BATHROOM. | | | | | | (B) FOR DWELLING UNITS, ATTACHED GARAGES, AND DETACHED | | | GARAGES WITH ELECTRIC POWER, AT LEAST ONE WALL SWITCH? | | | CONTROLLED LIGHTING OUTLET SHALL BE INSTALLED TO | | | PROVIDE ILLUMINATION | | | ON THE EXTERIOR SIDE OF OUTDOOR ENTRANCES OR EXITS | | | WITH GRADE LEVEL ACCESS. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2015-12-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-12-03 |
Time |
13:53 |
Rev Time |
|
| Received By |
lmarchan |
Date |
2015-11-24 |
Time |
16:46 |
Sent To |
B |
|
| Notes |
| 2015-11-30 18:00:03 | TO MARIO'S DESK | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-10-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-10-27 |
Time |
08:05 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-10-23 |
Time |
12:57 |
Sent To |
|
|
| Notes |
| 2015-10-23 12:57:25 | RESUB ROUTED TO SHILL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-10-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-10-08 |
Time |
12:39 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-09-28 |
Time |
10:37 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2015-10-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-10-08 |
Time |
12:39 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-10-08 |
Time |
12:39 |
Sent To |
|
|
| Notes |
| 2015-10-08 12:39:35 | AS SCOPE IS NOT CLEAR, I CANNOT DETERMINE WHETHER | | | ZONING REVIEW IS REQUIRED. | | | | | | |
|
|
|