| Plan Review Stops For Permit 15091217 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2015-12-29 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-12-29 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-12-29 |
Time |
15:40 |
Sent To |
I |
|
| Notes |
| 2015-12-29 15:53:20 | 12/29/15 STAMPED NEW SHEETS AS REQUIRED AND MADE | | | REFERENCE TO ELECTRICAL PROVISO FOR GFI OUTLETS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2015-12-17 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-12-17 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-12-17 |
Time |
08:38 |
Sent To |
I |
|
| Notes |
| 2015-12-17 11:21:03 | APPROVED WITH EXCEPTION AS FOLLOWS: IF THE SCOPE OF | | | THIS JOB INCLUDES ANY WORK WITHIN THE KITCHEN OUTLETS, | | | NEC 210.8(B)2, REQUIRES THAT ALL KITCHEN OUTLETS BE | | | GFCI PROTECTED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2015-10-19 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-10-19 |
Time |
19:56 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-10-19 |
Time |
18:26 |
Sent To |
I |
|
| Notes |
| 2015-10-19 19:57:28 | NO ELECTRICAL DATA PROVIDED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2015-12-09 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-12-17 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2015-12-09 |
Time |
11:18 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2015-10-06 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2015-10-06 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2015-10-06 |
Time |
15:56 |
Sent To |
E |
|
| Notes |
| 2015-10-06 16:01:19 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | ADDRESS COMMENTS OF OTHER DIVISIONS AND RESUBMITT. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2015-12-29 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-12-29 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-12-18 |
Time |
14:31 |
Sent To |
|
|
| Notes |
| 2015-12-29 15:54:33 | 12/29/15 READY FOR ISSUANCE. CONTRACTOR NOTIFIED VIA | | | PHONE CALL AS NO EMAIL ADDRESS IS PROVIDED. SENT TO | | | SMALL READY BIN "G". MA | | 2015-12-18 14:31:36 | RESUB ROUTED TO CCOLE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-12-17 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-12-17 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-12-07 |
Time |
09:54 |
Sent To |
FIRE |
|
| Notes |
| 2015-12-17 11:24:41 | 12/17/15 PASSED ELECTRICAL REVIEW BUT FAILED | | | MECHANICAL. CONTRACTOR NOTIFIED VIA PHONE CALL TO | | | NUMBER ON REV FORM. SENT TO SMALL DENIED BIN "G". MA |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-10-19 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-10-19 |
Time |
19:59 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-09-28 |
Time |
08:45 |
Sent To |
M |
|
| Notes |
| 2015-10-19 20:00:14 | 10/19/15 FAILED ELECTRICAL REVIEW. CONTRACTOR NOTIFIED | | | VIA EMAIL. SENT TO SMALL DENIED BIN "G". MA |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2015-12-21 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-12-21 |
Time |
08:09 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-12-21 |
Time |
08:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2015-12-16 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-12-16 |
Time |
07:08 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-12-16 |
Time |
07:08 |
Sent To |
|
|
| Notes |
| 2015-12-16 07:34:46 | 2ND REVIEW 2010 MECHANICAL | | | PERMIT REVISION #15091217 | | | 12/16/15 | | | | | | 1) IN RESPONSE TO THE MOST RECENT LETTER FROM TRANE | | | DATED NOVEMBER 5, 2015, PLEASE SEE SECTION 301.4 FBC-10 | | | MECHANICAL: 301.7 LISTED AND LABELED. | | | APPLIANCES REGULATED BY THIS CODE SHALL BE LISTED AND | | | LABELED FOR THE APPLICATION IN WHICH THEY ARE INSTALLED | | | AND USED, UNLESS OTHERWISE APPROVED IN ACCORDANCE WITH | | | SECTION 301.4.1. | | | EXCEPTION: LISTING AND LABELING OF EQUIPMENT AND | | | APPLIANCES USED FOR REFRIGERATION SHALL BE IN | | | ACCORDANCE WITH SECTION 1101.2. | | | ALTHOUGH THE LETTER STATES "DISCONNECTING AND REMOVING | | | THE HEATERS .....IS ACCEPTABLE TO TRANE", THE LETTER | | | ALSO STATES THE "FACTORY NAMEPLATE WILL NOT REFLECT | | | THIS CHANGE". DUE TO THE FACT THAT THE PRODUCT WAS | | | TESTED, APPROVED, AND LISTED WITH THE HEATERS IN TACT | | | AS PART OF THE PRODUCT ASSEMBLY, THE NAMEPLATE OR LABEL | | | IS NO LONGER VALID SINCE THE HEATERS HAVE BEEN REMOVED | | | IN THE FIELD. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2015-10-06 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-10-19 |
Time |
20:00 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-10-06 |
Time |
08:31 |
Sent To |
|
|
| Notes |
| 2015-10-06 08:40:53 | 1ST REVIEW: FBC 2010 MECHANICAL | | | REVISION #15091217, MASTER #15050778 | | | 10/6/15 | | | | | | 1) THE LETTER FROM MR. NERI OF TRANE SOUTH FLORIDA | | | ASSOCIATED WITH THIS PLAN REVISION WAS SUBMITTED | | | WITHOUT SIGNATURE. IN ADDITION, THE LETTER IS | | | REQUESTING THAT AN INSPECTOR APPROVE MECHANICAL | | | EQUIPMENT (VAV BOXES) THAT WILL BE ALTERED IN THE FIELD | | | WITHOUT CERTIFICATION BY THE MANUFACTURER OR THE | | | LISTING AND LABELING AGENCY- SECTION 301.4 FBC-10 | | | MECHANICAL. | | | 2) PLEASE NOTE THAT INSTALLATION OF THE NEW DUCT | | | HEATERS WILL REQUIRE A REVISION TO THE APPROVED | | | ELECTRICAL PLANS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|