| 2015-10-23 17:07:25 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE CALCULATIONS AND PLANS ARE REQUIRED TO HAVE THE | | | ENGINEER'S ORIGINAL HANDWRITTEN SIGNATURE ON THEM | | | (FACSIMILES ARE NOT ACCEPTABLE). FAC 61G15-23.002 | | | | | | 2) THE DESIGN CALCULATIONS ARE FOR MOUNTING SIGNS TO | | | MASONRY WALLS AND THE WALLS THE SIGNS WILL BE MOUNTED | | | ON FOR THIS PROJECT ARE WIRE LATH AND STUCCO ON PLYWOOD | | | ATTACHED TO METAL FRAMING. THE ANCHOR SPACING OF THE | | | PAIRS OF ANCHORS AT 40 INCHES ON CENTER IS MORE THAN | | | THE 19 INCHES ON CENTER THAT IS SPECIFIED IN THE ANCHOR | | | SCHEDULE FOR THE 1/2" PLYWOOD WALL MATERIAL ON THE SIGN | | | DRAWINGS. FBC 3107.1 & 1604.1 | | | | | | 3) THE PLANS ARE TOO SMALL AND WILL BE AN ISSUE FOR THE | | | FIELD INSPECTORS, AS WELL AS, FOR RECORD KEEPING | | | PURPOSES. THE INFORMATION IN THE ANCHOR SCHEDULE | | | REQUIRES MAGNIFICATION IN ORDER TO BE READ. FBC | | | 107.2.1.4 | | | | | | 4) THE ENGINEER'S SEAL IS REQUIRED TO BE A MINIMUM OF | | | 1-7/8 INCHES IN DIAMETER PER FAC 61G15-23.001. THE SEAL | | | ON THE SIGN DRAWINGS DOES NOT COMPLY. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-09-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-09-30 |
Time |
19:00 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-09-30 |
Time |
18:59 |
Sent To |
M |
|
| Notes |
| 2015-09-30 19:04:30 | SUBMIT TWO COMPLETE SETS OF PLANS WITH DIMENSIONS OF | | | SIGNES AND LOCATION OF ANCHORS. FBC 107.2.1 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2015-10-27 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-10-27 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-10-27 |
Time |
11:07 |
Sent To |
I |
|
| Notes |
| 2015-10-27 11:25:54 | NEW PROPERLY SIZED SHEETS WERE SUBMITTED, THIS TIME | | | CLEARLY IDENTIFYING THE DISCONNECT REQUIRED BY NEC | | | 600.6. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2015-10-14 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-10-14 |
Time |
10:24 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-10-14 |
Time |
10:23 |
Sent To |
|
|
| Notes |
| 2015-10-14 10:26:54 | AS PER A MEETING BETWEEN THE BACH SIGN REPRESENTATIVE, | | | DOUG HARVEY AND MYSELF, THE ATTACHED LETTER SHOULD BE | | | SUFFICIENT TO ADDRESS THE ELECTRICAL COMMENTS REQUIRED | | | FOR THE PERMIT APPROVAL. THE PERMIT WILL BE ISSUED | | | SUBJECT TO FIELD INSPECTOR APPROVAL OF ALL RECONNECTION | | | OF THESE SIGNS. (SEE ELECTRICAL PLAN REVIEW ATTACHMENTS | | | FOR COPY OF LETTER, HARD COPY WILL BE PLACED IN FILE) |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2015-10-01 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-10-01 |
Time |
08:54 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-10-01 |
Time |
08:52 |
Sent To |
I |
|
| Notes |
| 2015-10-01 09:08:48 | REGARDLESS OF WHEN THESE SIGNS WERE ONCE PERMITTED, | | | THIS APPLICATION SHALL BE COMPLETE WITH ALL DRAWINGS | | | AND SUPPORTING DOCUMENTS AS THIS IS A NEW PERMIT. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-10-23 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-10-23 |
Time |
17:08 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-10-19 |
Time |
12:57 |
Sent To |
|
|
| Notes |
| 2015-10-20 12:58:08 | RESUB ROUTED TO SGRAHAM |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-10-01 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-10-01 |
Time |
09:09 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-09-25 |
Time |
09:36 |
Sent To |
|
|
| Notes |
| 2015-10-01 09:19:38 | 10/1/15 FAILED ELECTRICAL REVIEW. CONTRACTOR NOTIFIED | | | VIA EMAIL. SENT TO SMALL DENIED BIN "B". MA | | 2015-09-28 09:36:58 | ROUTED TO ZONING |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2015-10-21 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2015-10-21 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
2015-10-21 |
Time |
15:08 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2015-09-30 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2015-09-30 |
Time |
12:43 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
2015-09-30 |
Time |
12:43 |
Sent To |
B |
|
| Notes |
| 2015-09-30 12:44:40 | 9/30/15 ZONING FAILED | | | | | | 1. SUBMIT TWO SETS OF COMPLETE SIGN PLANS, DIMENSIONS, | | | HEIGHT, LOCATION ETC. |
|
|