| Plan Review Stops For Permit 15090967 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2015-12-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2015-12-21 |
Time |
08:57 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2015-12-21 |
Time |
08:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2015-11-17 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2015-11-17 |
Time |
11:32 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2015-11-17 |
Time |
11:32 |
Sent To |
|
|
| Notes |
| 2015-11-17 11:37:47 | CHRISTOPHER S. THROOP, C.B.O. | | | BLDG. PLANS EXAMINER ? PX3169 | | | (561) 805-6718 | | | [email protected] | | | | | | SUBMITTAL MUST BE SIGNED BY DESIGNER. PROVIDE 2 COPIES. | | | | | | FBC-107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. ALL | | | INFORMATION, DRAWINGS, SPECIFICATIONS AND ACCOMPANYING | | | DATA SHALL BEAR THE NAME AND SIGNATURE OF THE PERSON | | | RESPONSIBLE FOR THE DESIGN. | | 2015-11-13 07:26:55 | LIGHT POLE SUBMITTAL RECEIVED TO BE ASSOCIATED WITH | | | APPLICATION TO ALLOW FOR SECOND REVIEW. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-11-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2015-11-03 |
Time |
11:46 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2015-11-03 |
Time |
11:46 |
Sent To |
FIRE |
|
| Notes |
| 2015-11-03 11:58:34 | CHRISTOPHER S. THROOP, C.B.O. | | | BLDG. PLANS EXAMINER PX3169 | | | (561) 805-6718 | | | [email protected] | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN | | | UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE | | | OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE | | | AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT | | | IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | | DETERMINED BY THE BUILDING OFFICIAL. SUCH DRAWINGS AND | | | SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM | | | OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS, | | | WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE | | | TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC, | | | AND THE TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE | | | OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS | | | EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | | INFORMATION. ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | | SECTION 107.3.5). | | | | | | PLEASE PROVIDE THE FOLLOWING INFORMATION FOR THE | | | PROPOSED LIGHT POLES: A) WIND SPEED DESIGN; B) | | | FOUNDATION & ANCHORAGE. | | | | | | 1603.1.4 WIND DESIGN DATA. | | | THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL | | | BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE | | | DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE | | | STRUCTURE: | | | 1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST), | | | MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED, | | | VASD, AS DETERMINED IN ACCORDANCE WITH SECTION | | | 1609.3.1. | | | 2. RISK CATEGORY. | | | 3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE | | | THAN ONE WIND EXPOSURE IS UTILIZED. | | | | | | 1801.1 SCOPE. | | | THE PROVISIONS OF THIS CHAPTER SHALL APPLY TO BUILDING | | | AND FOUNDATION SYSTEMS. | | | 1801.2 DESIGN BASIS. | | | ALLOWABLE BEARING PRESSURES, ALLOWABLE STRESSES AND | | | DESIGN FORMULAS PROVIDED IN THIS CHAPTER SHALL BE USED | | | WITH THE ALLOWABLE STRESS DESIGN LOAD COMBINATIONS | | | SPECIFIED IN SECTION 1605.3. THE QUALITY AND DESIGN OF | | | MATERIALS USED STRUCTURALLY IN EXCAVATIONS AND | | | FOUNDATIONS SHALL COMPLY WITH THE REQUIREMENTS | | | SPECIFIED IN CHAPTERS 16, 19, 21, 22 AND 23 OF THIS | | | CODE. EXCAVATIONS AND FILLS SHALL ALSO COMPLY WITH | | | CHAPTER 33. | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2016-02-02 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2016-02-02 |
Time |
15:11 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2016-02-02 |
Time |
14:25 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2016-01-22 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2016-01-22 |
Time |
10:06 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2016-01-22 |
Time |
09:10 |
Sent To |
I |
|
| Notes |
| 2016-01-22 10:22:29 | YOUR RESUBMITTAL ADDRESSING THE PREVIOUSLY MENTIONED | | | DEFICIENCIES HAS ONCE AGAIN FAILED THE ELECTRICAL | | | REVIEW AS INDICATED BELOW. NEW COMMENTS IF ANY PROMPTED | | | BY ANOTHER REVIEW, MOST LIKELY DUE TO YOUR FAILURE TO | | | SUBMIT A RESPONSE LETTER (NARRATIVE) ADDRESSING THE | | | REQUIRED CORRECTIONS WILL BE NUMBERED IN CONTINUATION | | | OF ANY PREVIOUS COMMENTS. THESE PLANS HAVE BEEN | | | REVIEWED FOR COMPLIANCE WITH THE EDITION OF THE NEC, | | | (NATIONAL ELECTRICAL CODE) AND THE FBC, (FLORIDA | | | BUILDING CODE) AS WELL AS THE CITY OF WEST PALM BEACH | | | AMENDMENTS IN EFFECT AT THE TIME OF SUBMITTAL. | | | | | | 1. ALL EXTERIOR LIGHTING SHALL COMPLY WITH FBC?E | | | SECTIONS C405.6.1 & C405.6.2 | | | | | | TO THIS COMMENT YOU PROVIDED A PHOTOMETRIC PLAN, BUT | | | FAIL TO INCLUDE THE POWER DENSITY ALLOWANCE CHART | | | SHOWING COMPLIANCE. | | | | | | 2. PROVIDE WIRING DETAIL OR CALCULATIONS INDICATING | | | COMPLIANCE WITH FBC?E405.7.3 | | | | | | YOU DID PROVIDE A RISER DIAGRAM AS REQUIRED, BUT DO NOT | | | INDICATE ON THE RISER DIAGRAM DETAIL OR ON THE | | | ELECTRICAL PLAN ANY PROTECTION FOR THIS EQUIPMENT. NEC | | | 110.27(B) REQUIRES THAT THERE BE PROTECTION FROM | | | PHYSICAL DAMAGE FOR THIS EQUIPMENT. FURTHERMORE, YOUR | | | RISER DIAGRAM CONFLICTS WITH ?ELECTRICAL GENERAL NOTES? | | | #2 WHICH PROHIBIT THE USE OF ALUMINUM CONDUCTORS. | | | | | | 3. YOU SHALL PROVIDE A FIXTURE SCHEDULE AND AN | | | ABBREVIATION AND SYMBOLS LEGEND | | | | | | THE FIXTURE SCHEDULE SAID TO BE ON SHEET GE1 IS | | | MISSING. THE FIXTURE SCHEDULE SHALL BE ON THE PLAN SET. | | | | | | 4. UNLESS PRIOR ARRANGEMENTS ARE MADE WITH THE | | | ELECTRICAL INSPECTOR, ALL TRENCHING SHALL REMAIN OPEN | | | FOR INSPECTION. NO SITE TUBES ARE ALLOWED. | | | | | | FOR FULL COMPLIANCE WITH THIS, PLEASE INCLUDE A NOTE ON | | | THE PLANS STATING THAT TRENCHES WILL REMAIN OPEN UNTIL | | | INSPECTED. | | | | | | | | | | | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | | RE-SUBMITTAL, YOU ARE REQUIRED TO PROVIDE A RESPONSE | | | LETTER (NARRATIVE) ADDRESSING EACH ITEM AND THE PAGE | | | NUMBER WHERE THE CORRECTIONS APPEAR ALONG WITH THE | | | STANDARD CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE | | | INSERT CORRECTED PAGES INTO THE SUBMITTAL PACKAGE. MARK | | | VOID AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR | | | COMPARATIVE REVIEW. CLOUDING THE CHANGES WILL BE | | | GREATLY APPRECIATED. | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | | CONTACT ME DIRECTLY. | | | | | | THANK YOU, | | | MIKE ALBARRAN | | | ELECTRICAL PLANS EXAMINER | | | PH: 561-805-6746 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2015-12-17 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-12-17 |
Time |
16:57 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-12-17 |
Time |
14:57 |
Sent To |
B |
|
| Notes |
| 2015-12-17 16:57:11 | THE PLANS FOR THE ABOVE MENTIONED PERMIT APPLICATION | | | HAVE BEEN REVIEWED FOR COMPLIANCE WITH THE EDITION OF | | | THE NEC, (NATIONAL ELECTRICAL CODE) AND THE FBC, | | | (FLORIDA BUILDING CODE) AS WELL AS THE CITY OF WEST | | | PALM BEACH AMENDMENTS IN EFFECT AT THE TIME OF | | | SUBMITTAL. BELOW IS A LIST OF THE DEFICIENCIES NOTED. | | | | | | 1. ALL EXTERIOR LIGHTING SHALL COMPLY WITH FBC-E | | | SECTIONS C405.6.1 & C405.6.2 | | | 2. PROVIDE WIRING DETAIL OR CALCULATIONS INDICATING | | | COMPLIANCE WITH FBC-E405.7.3 | | | 3. YOU SHALL PROVIDE A FIXTURE SCHEDULE AND AN | | | ABBREVIATION AND SYMBOLS LEGEND | | | 4. UNLESS PRIOR ARRANGEMENTS ARE MADE WITH THE | | | ELECTRICAL INSPECTOR, ALL TRENCHING SHALL REMAIN OPEN | | | FOR INSPECTION. NO SITE TUBES ARE ALLOWED. | | | | | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | | RE-SUBMITTAL, YOU ARE REQUIRED TO PROVIDE A RESPONSE | | | LETTER (NARRATIVE) ADDRESSING EACH ITEM ALONG WITH THE | | | STANDARD CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE | | | INSERT CORRECTED PAGES INTO THE SUBMITTAL AND LEAVE THE | | | PREVIOUSLY REVIEWED SHEETS FOR COMPARISON. | | | CLOUDING THE CHANGES WILL BE GREATLY APPRECIATED. | | | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | | CONTACT ME DIRECTLY. | | | | | | THANK YOU, | | | MIKE ALBARRAN | | | ELECTRICAL PLANS EXAMINER | | | PH: 561-805-6746 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2015-10-08 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-10-08 |
Time |
12:26 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-10-08 |
Time |
12:18 |
Sent To |
Z |
|
| Notes |
| 2015-10-08 12:32:14 | I INITIALLY STAMPED THE DRAWINGS FOR THE SITE LIGHTING | | | ELECTRIC, BUT HAD TO FAIL THE APPLICATION DUE TO | | | INCOMPLETE SUBMITTAL. YOU SHALL PROVIDE SPECS ON THE | | | PROPOSED LUMINARIES AND SUPPORTING POLES AS WELL AS FOR | | | THE GATE OPENERS AND READERS. YOU SHALL ALSO INCLUDE A | | | DETAIL ON THE MOUNTING AND GROUNDING OF THE POLES. THE | | | APPLICATION ALSO MENTIONED CAR CHARGERS AND NO MENTION | | | OF CAR CHARGERS APPEARS ON THE PANELS NOR IS THE | | | REQUIRED LITERATURE FOR THE CHARGERS INCLUDED. A BLDG | | | STOP WILL BE ADDED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
N |
Date |
2015-11-18 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2015-11-18 |
Time |
13:31 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2015-11-18 |
Time |
13:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2016-02-02 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2016-02-02 |
Time |
15:13 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2016-01-26 |
Time |
10:03 |
Sent To |
Z |
|
| Notes |
| 2016-02-02 15:14:47 | 2/2/16 PERMIT READY FOR ISSUANCE. CONTRACTOR NOTIFIED | | | VIA EMAIL. SENT FILE TO SMALL READY BIN F. MA | | 2016-01-27 10:04:09 | SENT TO ESCHNEIDER |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2016-01-22 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2016-01-22 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2016-01-05 |
Time |
13:07 |
Sent To |
|
|
| Notes |
| 2016-01-22 10:25:09 | 1/22/16 FAILED ELECTRICAL REVIEW AS NOTED. CONTRACTOR | | | NOTIFIED VIA EMAIL. FILE SENT TO LARGE DENIED DRAWER | | | "F". MA | | 2016-01-05 13:09:12 | RESUB ROUTED TO ESCHNEIDER VIA SGRAHAM'S DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-12-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2015-12-21 |
Time |
08:56 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2015-12-14 |
Time |
10:08 |
Sent To |
|
|
| Notes |
| 2015-12-14 10:08:56 | RESUB ROUTED TO ESCHNEIDER VIA SGRAHAM'S DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-11-19 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-11-17 |
Time |
12:33 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2015-09-23 |
Time |
14:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2016-01-29 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2016-02-02 |
Time |
15:14 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2016-01-29 |
Time |
09:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2016-01-05 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2016-01-05 |
Time |
17:06 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2016-01-05 |
Time |
17:06 |
Sent To |
E |
|
| Notes |
| 2016-01-05 17:40:02 | PASSED W/PROVISO | | | | | | 1) PRIOR TO THE 104 FINAL INSPECTION, PROVIDE REVISED | | | PHOTOMETRIC DRAWING BASED ON ACTUAL POLE LOCATIONS. | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2015-12-16 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2015-12-16 |
Time |
11:16 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2015-12-16 |
Time |
11:16 |
Sent To |
E |
|
| Notes |
| 2015-12-16 11:33:38 | FAILED | | | | | | 1) THE BASE PARKING LOT LAYOUT IS NOT THE ONE APPROVED | | | THROUGH THE PPRC REVIEW. THE PARKING LOT HAS SHIFTED | | | WEST APPROXIMATELY 3.5 FEET; THEREFORE THE LIGHT POLE | | | LOCATIONS ARE NOT SHOWN IN THE CORRECT LOCATIONS. | | | | | | 2) ZONING STAFF IS UNCLEAR AS TO THE LOCATION OF THE | | | CAR CHARGING STATIONS. PLEASE CLEARLY ANNOTATE THEM ON | | | THE PLAN. | | | | | | 3) HOW TALL ARE THE CHARGING STATIONS? | | | | | | 4) NO LIGHT POLE OR FIXTURE DETAILS PROVIDED. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2015-10-23 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2015-10-23 |
Time |
10:28 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2015-10-23 |
Time |
10:27 |
Sent To |
|
|
| Notes |
| 2015-10-23 12:05:35 | FAILED | | | | | | 1) THE MINOR AMENDMENT TO CONVERT THE GARAGE TO A | | | SURFACE PARKING LOT HAS NOT BEEN APPROVED. THE LIGHT | | | POLE AND ENTRY GATE LOCATIONS MAY CHANGE BASED ON HOW | | | THE COMMENTS FROM THE MINOR AMENDMENT ARE ADDRESSED, SO | | | ZONING WILL NOT APPROVE THIS PERMIT UNTIL THE MINOR | | | AMENDMENT PLANS ARE APPROVED. | | | | | | 2) PROVIDE THE LIGHT POLE AND FIXTURE DETAILS. THESE | | | WERE INCLUDED AS PART OF THE MINOR AMENDMENT. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. |
|
|