Plan Review Details - Permit 15090920
Plan Review Stops For Permit 15090920
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2015-10-16 Cont ID  
Sent By rmcdouga Date 2015-10-16 Time 09:10 Rev Time 0.00
Received By rmcdouga Date 2015-10-16 Time 09:10 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2015-10-15 Cont ID  
Sent By rmcdouga Date 2015-10-15 Time 07:05 Rev Time 0.00
Received By rmcdouga Date 2015-10-15 Time 07:05 Sent To  
Notes
2015-10-15 07:32:00NOTE: THE REVISED PLANS THAT SHOW THE FLOOD VENTS IN
 THE GARAGE HAVE BEEN REVIEWED AND APPROVED.
  
 ELEVATION CERTIFICATE REVIEW
  
 DENIED
  
 THE ELEVATION CERTIFICATE COMMENTS FROM THE FIRST
 REVIEW HAVE NOT BEEN ADDRESSED.
 1) CORRECT SQUARE FOOTAGE OF ATTACHED GARAGE TO 632 PER
 ARCHITECT PLANS.
 2) IN SECTION D, PAGE 2, OF THE ELEVATION CERTIFICATE,
 PLEASE LIST AND IDENTIFY THE LOCATIONS OF THE VENT AS
 THEY ARE INSTALLED IN THE GARAGE.
 3) PHOTOS ARE REQUIRED TO BE IN COLOR WITH PROPERLY
 IDENTIFYING ALL ELEVATIONS OF THE BUILDING (FRONT,
 REAR, NORTH, SOUTH) PER FEMA GUIDELINES.
 4)THE ORIGINAL HANDWRITTEN SIGNATURE OF THE SURVEYOR
 AND DATE SEALED IS REQUIRED ON ALL DOCUMENTS SUBMITTED
 FOR PUBLIC RECORD. FS 472.025
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-09-22 Cont ID  
Sent By shill Date 2015-09-22 Time 11:49 Rev Time 0.00
Received By shill Date 2015-09-22 Time 11:49 Sent To  
Notes
2015-09-22 11:57:02****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. THE AS BUILT CONDITIONS ARE NOT CONSISTENT WITH THE
 ISSUED PERMIT. PER THE ELEVATION CERTIFICATE, FLOOD
 VENTS WERE INSTALLED. SUBMIT A REVISION WHICH SHOWS
 LOCATION OF PROPOSED VENTS AND ENGINEERING OR PRODUCT
 APPROVAL FOR THE VENTS.
  
 ONLY FLOOD DAMAGE RESISTANT MATERIALS ARE PERMITTED
 BELOW DFE (SEE FEMA TECHNICAL BULLETIN 1, PAGE 8).
  
 2. REGARDING THE ELEVATION CERTIFICATE PREPARED BY
 MICHAEL J. MILLER, PLEASE ADDRESS THE FOLLOWING:
  
 A. SEE A9(A), SQUARE FOOT OF GARAGE ON THE PLAN IS 632
 SQUARE FEET. EITHER REVISE THE PLAN (SEE SHEET SP1
 WHICH SHOWS 632 SF) OR REVISE THE ELEVATION
 CERTIFICATE; THE TWO SHOULD BE CONSISTENT.
  
 B. SEE ELEVATION CERTIFICATE INSTRUCTIONS; IF
 ENGINEERED FLOOD VENTS ARE USED, ENGINEERING OR THE
 PRODUCT APPROVAL ARE TO BE ATTACHED TO THE ELEVATION
 CERTIFICATE.
  
 C. SEE ELEVATION CERTIFICATE INSTRUCTIONS (AND NOTE ON
 ELEVATION CERTIFICATE), PHOTOGRAPHS OF FLOOD VENTS ARE
 REQUIRED. THE EC STATES: "WHEN APPLICABLE, PHOTOGRAPHS
 MUST SHOW THE FOUNDATIOON WITH REPRESENTATIVE EXAMPLES
 OF THE FLOOD OPENINGS OR VENTS, AS INDICATED IN SECTION
 A8. IF SUBMITTING MORE PHOTOGRAPHS THAN WILL FIT ON
 THIS PAGE, USE THE CONTINUATION PAGE."
  
 FBC 107, PHOTOGRAPHS SHOULD BE IN COLOR AND ARE
 REQUIRED AS A PART OF THE CITY'S COMMUNITY RATING
 SYSTEM.
  
 D. SEE FEMA TECHNICAL BULLETIN 1, INFORMATION REGARDING
 THE FLOOD VENTS SHOULD BE INCLUDED IN THE COMMENTS
 SECTION.
  
 BULLETIN ALSO STATES THAT ONLY THE PORTION OF THE VENT
 WHICH IS BELOW DFE IS TO BE COUNTED TOWARDS THE FLOOD
 VENT AREA (SEE PAGES 3, 11 OF FEMA TECHNICAL BULLETIN
 1: HTTP://WWW.FEMA.GOV/MEDIA-LIBRARY-DATA/20130726-1502
 -20490-9949/FEMA_TB_1__1_.PDF).
  
  
  
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-09-22 Cont ID  
Sent By shill Date 2015-09-22 Time 11:48 Rev Time 0.00
Received By shill Date 2015-09-22 Time 11:47 Sent To  
Notes
***NONE***

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 1 Status F Date 2015-09-24 Cont ID  
Sent By shill Date 2015-09-24 Time 16:39 Rev Time 0.00
Received By shill Date 2015-09-24 Time 16:39 Sent To  
Notes
2015-09-24 16:40:08SEE BUILDING REVIEW
  