| Plan Review Stops For Permit 15090428 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2015-10-31 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-10-31 |
Time |
09:44 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-10-31 |
Time |
09:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-10-20 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-10-20 |
Time |
15:47 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-10-20 |
Time |
15:47 |
Sent To |
|
|
| Notes |
| 2015-10-20 16:16:39 | 1ST REVIEW: FBC 2014 5TH ED. RESIDENTIAL & EXISTING | | | BUILDING VOLUMES | | | | | | THE CODE IN EFFECT LISTED IN THE CODE SUMMARY ON SHEET | | | A1.0 IS OUT DATED, SEE ABOVE FOR CURRENT VERSION. | | | | | | THE PLAN INDICATES ROOFING WINDOWS AND DOORS WILL BE | | | REPLACED. | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING, WINDOW, AND DOOR | | | SUBMITTALS. | | | | | | ALTHOUGH THE PLAN NOTES INDICATE AN ENERGY SUBMITTAL | | | WILL BE PROVIDED, THE HOME IS EXEMPT FROM THE | | | REQUIREMENT AS IT IS CONSIDERED A CONTRIBUTING HISTORIC | | | STRUCTURE. EITHER PROVIDE A SUBMITTAL OR REMOVE THE | | | NOTES FROM THE PLAN. | | | | | | FBC-R 315.1 PROVIDE CARBON MONOXIDE ALARMS WITHIN 10 | | | FEET OF EACH SLEEPING ROOM. | | | | | | STEVEN KENNEDY, CBO | | | CHIEF PLANS EXAMINER | | | (561) 805-6710 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2015-10-31 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-10-31 |
Time |
09:44 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-10-31 |
Time |
09:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2015-10-20 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-10-20 |
Time |
16:29 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-10-20 |
Time |
16:29 |
Sent To |
|
|
| Notes |
| 2015-10-20 16:48:36 | 1ST REVIEW: FBC 2014 5TH ED. | | | | | | PLEASE MODIFY THE PLAN TO INDICATE COMPLIANCE WITH THE | | | FOLLOWING SECTIONS: | | | | | | FBCRE3902.12 ARC-FAULT CIRCUIT-INTERRUPTER PROTECTION. | | | ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, | | | 15- AND 20-AMPERE OUTLETS INSTALLED IN FAMILY ROOMS, | | | DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, | | | BEDROOMS, SUNROOMS, RECREATIONS ROOMS, CLOSETS, | | | HALLWAYS AND SIMILAR ROOMS OR AREAS SHALL BE PROTECTED | | | BY A COMBINATION TYPE ARC-FAULT CIRCUIT INTERRUPTER | | | INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT. | | | | | | E3703.2 KITCHEN AND DINING AREA RECEPTACLES. | | | A MINIMUM OF TWO 20-AMPERE-RATED BRANCH CIRCUITS SHALL | | | BE PROVIDED TO SERVE ALL WALL AND FLOOR RECEPTACLE | | | OUTLETS LOCATED IN THE KITCHEN, PANTRY, BREAKFAST AREA, | | | DINING AREA OR SIMILAR AREA OF A DWELLING. THE KITCHEN | | | COUNTERTOP RECEPTACLES SHALL BE SERVED BY A MINIMUM OF | | | TWO 20-AMPERE-RATED BRANCH CIRCUITS, EITHER OR BOTH OF | | | WHICH SHALL ALSO BE PERMITTED TO SUPPLY OTHER | | | RECEPTACLE OUTLETS IN THE SAME KITCHEN, PANTRY, | | | BREAKFAST AND DINING AREA INCLUDING RECEPTACLE OUTLETS | | | FOR REFRIGERATION APPLIANCES. | | | | | | FBCRE4002.14 TAMPER-RESISTANT RECEPTACLES. | | | IN AREAS SPECIFIED IN SECTION E3901.1, 125-VOLT, 15- | | | AND 20-AMPERE RECEPTACLES SHALL BE LISTED | | | TAMPER-RESISTANT RECEPTACLES. | | | | | | FBC-R 315.1 ? CARBON MONOXIDE ALARMS WITHIN 10 FEET OF | | | EACH SLEEPING ROOM. | | | | | | FBC- 107.3.5.3 ? SMOKE DETECTORS PURSUANT TO FBC-R | | | 314.3.1 AS REQUIRED FOR NEW DWELLINGS | | | | | | STEVEN KENNEDY, CBO | | | CHIEF PLANS EXAMINER | | | (561) 805-6710 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2015-10-29 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2015-10-29 |
Time |
16:43 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2015-10-29 |
Time |
16:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2015-09-21 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2015-09-21 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2015-09-21 |
Time |
16:40 |
Sent To |
|
|
| Notes |
| 2015-09-21 16:48:24 | | | | 1ST REVIEW: FBC 2014 | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | | | | | | | GAS COMMENTS: | | | | | | | | | | | | | | | 1. SHOW TYPE OF PIPING MATERIAL BEING INSTALLED, ALL | | | PIPE SIZES, AND THE EHD NUMBER OF CORRUGATED STAINLESS | | | STEEL TUBING FOR EACH PIPE SIZE IF BEING USED. WPB | | | AMENDMENTS TO FBC SEC. 107.2.1. | | | 2. TYPE OF GAS, (LP OR NATURAL). | | | 3. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS FOR ALL | | | GAS EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA | | | 54, NFPA 58, AND FBC-2014 FUEL GAS SEC. 402.2 | | | 4. GRILL MUST BE SHOWN ON RISER PER WPB AMEND 107.2.1 |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2015-10-07 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2015-10-07 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2015-10-07 |
Time |
13:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-10-31 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-10-31 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-10-28 |
Time |
13:46 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-10-20 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-10-20 |
Time |
16:50 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-09-11 |
Time |
14:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2015-10-29 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-10-31 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2015-10-29 |
Time |
16:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2015-09-22 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2015-09-22 |
Time |
06:49 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2015-09-21 |
Time |
16:53 |
Sent To |
|
|
| Notes |
| 2015-09-22 07:01:46 | | | | 1ST REVIEW: FBC 2014 | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | | | | | | | PLUMBING COMMENTS: | | | | | | 1. SHEET P1 PLUMBING RISER IS NOT SIZED COMPLETELY OR | | | PER CODE SHALL BE SIZED TO COMPLY WITH. FBCP SEC 710.1 | | | MAXIMUM FIXTURE UNIT LOAD.AND TABLE 710.1(1) BUILDING | | | DRAINS AND SEWERS. | | | 2. WASHING MACHINE SHALL BE SHOWN ON RISER AND FLOOR | | | PLAN ON SHEET P3 . PER WPB AMEND. SEC 107.2.1 | | | 3. PLEASE PROVIDE WATER RISER. PER.WPB AMEND. | | | SEC107.3.5.3(11) |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
N |
Date |
2015-10-31 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2015-10-29 |
Time |
16:43 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-10-29 |
Time |
16:43 |
Sent To |
|
|
| Notes |
| 2015-10-31 09:44:20 | 2ND REVIEW: FBC 2014 5TH ED. | | | | | | NO ROOFING PRODUCT APPRAVAL WAS SUBMITTED. A SEPARATE | | | PERMIT WITH A PRODUCT APPROVAL SUBMITTAL REVIEWED BY | | | THE DESIGNER OF RECORD IS REQUIRED. | | | | | | STEVEN KENNEDY, CBO | | | CHIEF PLANS EXAMINER | | | (561) 805-6710 | | | [email protected] | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2015-10-20 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-10-20 |
Time |
16:48 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-10-20 |
Time |
16:48 |
Sent To |
|
|
| Notes |
| 2015-10-20 16:50:11 | 1ST REVIEW: FBC 2014 5TH ED. RESIDENTIAL & EXISTING | | | BUILDING VOLUMES | | | | | | THE PLAN INDICATES ROOFING WINDOWS AND DOORS WILL BE | | | REPLACED. | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING A SUBMITTAL. | | | | | | STEVEN KENNEDY, CBO | | | CHIEF PLANS EXAMINER | | | (561) 805-6710 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2015-10-07 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2015-10-07 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2015-10-07 |
Time |
13:50 |
Sent To |
|
|
| Notes |
| 2015-09-18 11:42:48 | 9/18/15 |
|
|