Plan Review Details - Permit 15090376
| Plan Review Stops For Permit 15090376 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2015-09-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-09-22 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-09-22 |
Time |
10:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2015-09-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-09-21 |
Time |
18:07 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-09-21 |
Time |
18:07 |
Sent To |
|
|
| Notes |
| 2015-09-21 18:12:56 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. ONE COPY OF THE PRODUCT APPROVAL FOR A 2014 ATTIC | | | VENT PRODUCT APPROVAL WAS SUBMITTED. | | | | | | TWO SETS ARE REQUIRED, FBC 107. | | | | | | THE PRODUCT APPROVAL WAS SUBMITTED WITH TWO PAGES TO A | | | SHEET. THIS RESULTS IN A PRODUCT APPROVAL WHICH IS NOT | | | LEGIBLE. THE PRODUCT APPROVAL IS TO BE FULL SIZE (ONE | | | PAGE ON AN 8.5" X 11" SHEET OF PAPER). THE PRODUT | | | APPROVALS ARE REQUIRED TO BE REVIEWED IN PLAN REVIEW, | | | INSPECTED IN THE FIELD, AND SCANNED FOR RECORD | | | RETENTION. WHEN PRINTED HALF SIZE, THE PRODUCT APPROVAL | | | IS TOO DIFFICULT TO READ. | | | | | | PROVIDE TWO FULL SIZE COPIES OF THE PRODUCT APPROVAL. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2015-09-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-09-17 |
Time |
11:03 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-09-17 |
Time |
11:03 |
Sent To |
|
|
| Notes |
| 2015-09-17 11:05:51 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FROM PREVIOUS LSIT: | | | | | | 2. FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED FOR | | | THE SOLAR VENT. PROVIDE THE COVER SHEET WHICH SHOWS THE | | | APPROVAL NUMBER, CODE VERSION, AND STATUS | | | (WWW.FLORIDABUILDING.ORG). THE COVER SHEET WILL STATE | | | THAT THE CODE IS FBC 2014. THE EVALUATION REPORT | | | PROVIDED IS EXPIRED AS IT MAKES REFERENCE TO FBC 2010 | | | (GOVERNING CODE IS FBC 5TH EDITION, AKA FBC 2014). | | | | | | 2ND REVIEW, DIFFERENT PRODUCT APPROVAL SUBMITTED BUT | | | STILL FBC 2010. THIS PRODUCT APPROVAL IS EXPIRED. | | | GOVERNING CODE CHANGED EFFECTIVE JUNE 31, 2015, SO | | | PRODUCT APPROVALS WITH A CODE OF FBC 2010 ARE ALL | | | EXPIRED. | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-09-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-09-11 |
Time |
18:10 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-09-11 |
Time |
18:10 |
Sent To |
|
|
| Notes |
| 2015-09-11 18:11:34 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED FOR | | | PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | | ORIGINALS, FS 471. POOR QUALITY PHOTOCOPIES WERE | | | SUBMITTED. | | | | | | 2. FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED FOR | | | THE SOLAR VENT. PROVIDE THE COVER SHEET WHICH SHOWS THE | | | APPROVAL NUMBER, CODE VERSION, AND STATUS | | | (WWW.FLORIDABUILDING.ORG). IT APPEARS THAT THE | | | EVALUATION REPORT PROVIDED IS EXPIRED AS IT MAKES | | | REFERENCE TO FBC 2010 (GOVERNING CODE IS FBC 5TH | | | EDITION, AKA FBC 2014). | | | | | | 3. SEE INSTALLATION NOTES, ITEM 7.3, "PRODUCT SHALL BE | | | INSTALLED ON ROOFS UTILIZING ASPHALT SHINGLES ONLY". | | | | | | 4. REVISE ROOF PLAN TO SHOW THE LOCATION OF PROPOSED | | | ROOF VENT AND ROOF SHEATHING INFORMATION (TYPE OF ROOF | | | SHEATHING, THICKNESS). THIS INFORMATION IS REQUIRED DUE | | | TO LIMITATIONS FOR THE ROOF VENT. | | | | | | 5. PURPOSE OF PROPOSED VENT IS NOT CLEAR. FLAT DECK | | | ROOFS TYPICALLY DO NOT HAVE AN ATTIC SPACE. WHAT IS | | | BEING VENTED? | | | | | | 6. CONTRACTOR TO CONFIRM THAT A FIRE BARRIER IS | | | PROPOSED. CONTRACTOR HAS SELECTED THE ASSEMBLY ON PAGE | | | 12 OF 13, NOA 12-1019.34, SYSTEM TYPE E. NOTE THAT THE | | | SYSTEM PROPOSED INCLUDES A FIRE BARRIER. THIS IS NOT | | | OPTIONAL. OPTIONAL ITEMS WILL STATE (OPTIONAL); FOR AN | | | EXAMPLE OF AN OPTIONAL COMPONENT, SEE PAGE 9, VAPOR | | | RETARDER. SINCE THE FIRE BARRIER IS NOT "OPTIONAL" IT | | | IS A PART OF THIS ASSEMBLY AND IS REQUIRED. | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2015-09-11 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2015-09-11 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2015-09-11 |
Time |
11:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2015-09-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-09-21 |
Time |
18:13 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-09-21 |
Time |
18:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-09-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-09-17 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-09-17 |
Time |
11:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-09-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-09-11 |
Time |
18:11 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-09-10 |
Time |
11:44 |
Sent To |
|
|
| Notes |
| 2015-09-11 11:44:43 | SKENNEDY |
|
|
|
Account Summary | Usage Policy | Privacy Policy