Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2016-01-05 Cont ID  
Sent By shill Date 2016-01-05 Time 12:22 Rev Time 0.00
Received By shill Date 2016-01-05 Time 12:22 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2015-11-19 Cont ID  
Sent By shill Date 2015-11-19 Time 17:20 Rev Time 0.00
Received By shill Date 2015-11-19 Time 16:37 Sent To  
Notes
2015-11-19 16:52:01****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. PROPOSED IMPROVEMENT IS LOCATED IN A SPECIAL HAZARD
 FLOOD ZONE. FBC 1612 AND CITY OF WEST PALM BEACH
 MUNICIPAL CODE 94, 7' NGVD 29 ELEVATION PROPOSED. SINCE
 THE COMMUNITY HAS A 6" FREEBOARD REQUIREMENT, THE
 PROPOSED IMPROVEMENT IS TO BE DESIGNED TO RESIST FLOOD
 LOADS.
  
 TO AVOID THE RESUBMITTAL BEING SENT TO ZONING AND
 ENGINEERING, IF NO DESIGN CHANGE IS REQUIRED, IT IS
 SUGGESTED THAT COMPLIANCE BE STATED IN A SIGNED AND
 SEALED LETTER.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-09-19 Cont ID  
Sent By shill Date 2015-09-19 Time 12:44 Rev Time 0.00
Received By shill Date 2015-09-19 Time 12:44 Sent To ENG
Notes
2015-09-19 12:53:49****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. PROVIDE A COPY OF THE SURVEY FOR THIS PROPERTY, FBC
 107.
  
 2. PROVIDE A SITE PLAN WHICH SHOWS THE LOCATION OF THE
 PROPOSED IMPROVEMENT, FBC 107.
  
 3. THIS APPEARS TO BE LOCATED IN A SPECIAL HAZARD FLOOD
 ZONE. PROVIDE ELEVATION INFORMATION (PROPOSED ELEVATION
 OF IMPROVEMENT), FBC 107. REVISE PLANS TO SHOW
 COMPLIANCE WITH FBC 1612.
  
 4. INCORRECT GOVERNING CODE IS REFERENCED ON THE PLAN
 (DESIGN LOADS & MATERIAL SPECIFICATIONS) AND INCLUDES A
 REFERENCE TO CHAPTER 3. CHAPTER 3 IS OCCUPANCY
 CLASSIFICATION, NOT CLEAR HOW THIS RELATES TO DESIGN
 LOADS, PLEASE REVISE.
  

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2015-11-19 Cont ID  
Sent By cranford Date 2015-11-19 Time 11:09 Rev Time 0.00
Received By cranford Date 2015-11-19 Time 11:09 Sent To  
Notes
2015-11-19 11:09:17REPLACING EXISTING DUMPSTER ENCLOSURE.

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2015-09-21 Cont ID  
Sent By cranford Date 2015-09-21 Time 15:39 Rev Time 0.00
Received By cranford Date 2015-09-21 Time 14:02 Sent To  
Notes
2015-09-21 15:39:291. DROP PINS TO BE INSTALLED ON BOTH GATES. DROP PIN
 HOLES TO BE INSTALLED IN SLAB TO HOLD GATES OPEN AT 90
 DEGREES.
  
 2. MINIMUM ENCLOSURE WIDTH IS 12 FT 6 INCHES TO ALLOW
 FOR TRUCK TO ENTER ENCLOSURE. MINIMUM ENCLOSURE DEPTH
 IS ALSO 12 FT 6 INCHES.
  
 KELLY CRANFORD, P.E.
 LAND DEVELOPMENT ENGINEER
 PUBLIC WORKS DEPARTMENT
 CITY OF WEST PALM BEACH
 [email protected]
 561-494-1098 (OFFICE)

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2016-01-05 Cont ID  
Sent By shill Date 2016-01-05 Time 12:22 Rev Time 0.00
Received By shill Date 2015-12-29 Time 14:05 Sent To  
Notes
2015-12-29 14:05:46SHILL'S DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-11-19 Cont ID  
Sent By shill Date 2015-11-19 Time 17:22 Rev Time 0.00
Received By shill Date 2015-10-14 Time 13:00 Sent To  
Notes
2015-10-21 14:40:4910/21 TO ENGINEERING BOX
  
2015-10-15 16:47:04TO MISC 2 BOX.
2015-10-14 13:00:31RESUB ROUTED TO AAPONTE VIA SGRAHAM'S DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-09-21 Cont ID  
Sent By cranford Date 2015-09-21 Time 15:39 Rev Time 0.00
Received By cranford Date 2015-09-10 Time 09:43 Sent To  
Notes
2015-09-19 12:54:169/19 TO ENGINEERING BOX
  
2015-09-17 15:19:51TO MISC 2 BOX.
2015-09-10 09:43:16ROUTED TO ZONING

Review Stop Z ZONING
Rev No 2 Status P Date 2015-10-15 Cont ID  
Sent By aaponte Date 2015-10-15 Time 16:46 Rev Time 0.00
Received By aaponte Date 2015-10-15 Time 16:46 Sent To  
Notes
2015-10-15 16:46:51PROVISO: HEDGES SHALL BE INSTALLED BEFORE A CO CAN BE
 ISSUED.

Review Stop Z ZONING
Rev No 1 Status F Date 2015-09-17 Cont ID  
Sent By aaponte Date 2015-09-17 Time 15:14 Rev Time 0.00
Received By aaponte Date 2015-09-17 Time 15:14 Sent To  
Notes
2015-09-17 15:19:381. PLEASE PROVIDE A SURVEY OF THE PROPERTY INDICATING
 ALL THE ELEMENTS AROUND (MECHANICAL EQUIPMENT AROUND
 EXISTING DUMPSTER).
 2. A HEDGE SHALL BE PROVIDED AROUND THE DUMPSTER,
 PLATED AT TWO FOOT INTERVALS (SEC 94-444(B). IRRIGATION
 SHALL BE PROVIDED.
 3. DUMPTER SHALL FOLLOW CITY STANDARDS CONTAINED IN
 FIGURE XIV-3 OF THE ZONING CODE WHICH REQUIRED A
 MINIMUM 13'-8" BY 13'-8" SIZE ENCLOSURE AND A STOP BAR.
 FOR ADDITONAL INFORMATION PLEASE CONTACT ANA MARIA
 APONTE AT 561-822-1439.