Plan Review Details - Permit 15090321
Plan Review Stops For Permit 15090321
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-09-16 Cont ID  
Sent By rmcdouga Date 2015-09-16 Time 13:44 Rev Time 0.00
Received By rmcdouga Date 2015-09-16 Time 13:44 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-09-15 Cont ID  
Sent By rmcdouga Date 2015-09-15 Time 07:55 Rev Time 0.00
Received By rmcdouga Date 2015-09-15 Time 07:44 Sent To  
Notes
2015-09-15 10:09:09PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE MAXIMUM DESIGN PRESSURE FOR THE FASTENING OPTION
 THAT YOU INDICATED ON PAGE 25 OF NOA NO. 14-0611.01 IS
 -45 PSF WHICH IS NOT ADEQUATE FOR THE PERIMETER AND
 CORNER ROOF ZONES OF A TWO STORY STRUCTURE LOCATED IN A
 170 MPH VULT. WIND SPEED. SUBMIT TWO SETS OF SIGNED AND
 SEALED RAS 117 CALCULATIONS AS REQUIRED BY LIMITATION
 #7 ON PAGE 29 OF THE PRODUCT APPROVAL.

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2015-09-14 Cont ID  
Sent By fmittner Date 2015-09-14 Time 10:03 Rev Time 0.00
Received By fmittner Date 2015-09-14 Time 10:03 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-09-15 Cont ID  
Sent By rmcdouga Date 2015-09-15 Time 07:55 Rev Time 0.00
Received By rmcdouga Date 2015-09-14 Time 13:12 Sent To B
Notes
2015-09-14 13:12:31RMCDOUGAL