Plan Review Details - Permit 15090268
Plan Review Stops For Permit 15090268
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2015-09-25 Cont ID  
Sent By jwitmer Date 2015-09-25 Time 07:14 Rev Time  
Received By jwitmer Date 2015-09-25 Time 06:45 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2015-11-19 Cont ID  
Sent By dharvey Date 2015-11-19 Time 08:00 Rev Time 0.00
Received By dharvey Date 2015-11-19 Time 07:51 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2015-11-03 Cont ID  
Sent By dharvey Date 2015-11-03 Time 10:12 Rev Time 0.00
Received By dharvey Date 2015-11-02 Time 15:44 Sent To  
Notes
2015-11-03 10:12:31PLEASE INDICATE IF LOCATION OF TRANSFORMER CHANGES AND
 CONFIRM CLEARANCE REQUIREMENTS ALONG WITH ATTACHMENT TO
 THE BUILDING GROUNDING ELECTRODE SYSTEM AND BONDING OF
 OTHER SYSTEMS.
 PROVIDE SUPPORT OR HANGING INFORMATION FOR TRANSFORMER,
 IF EXISTING, PLEASE SO INDICATE AND IDENTIFY POINT LOAD
 CONFORMANCE ON STRUCTURE
 GROUNDING RECEPTACLE DETAIL DOES NOT INDICATE THE IF
 UNGROUNDED OR GROUNDED CONDUCTOR "FEEDS THRU" THE
 RECEPTACLE, 2 OF 3 CONDUCTORS ARE SPLICED AND TAILED.
 EXISTING SYMBOL IN OFFICE 1136 SHOWN AT 5'8" DOES NOT
 APPEAR IN THE LEGEND. PLEASE DEFINE (CATV?)
 REFERENCED DOCUMENTS UNDER ELECTRICAL NOTE 1 DO NOT
 CORRESPOND TO THE FLORIDA BUILDING CODE CHAPTER 35
 ELECTRICAL NOTE #27 INDICATES A NON-STANDARD BOX,
 PLEASE PROVIDE LISTING INFORMATION
 ELECTRICAL NOTE #23 REQUIRES "CLEANING" OF ALL DEVICES
 AND EQUIPMENT. ENSURE ITEMS ARE NOT DAMAGED AND COMPLY
 WITH NEC 110.11
  
 REVIEW PERFORMED BY:
 DOUG HARVEY
 [email protected]
 561-805-6740

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2015-09-10 Cont ID  
Sent By scaldero Date 2015-09-10 Time 13:27 Rev Time 0.00
Received By scaldero Date 2015-09-10 Time 13:27 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-11-19 Cont ID  
Sent By dharvey Date 2015-11-19 Time 08:00 Rev Time 0.00
Received By dharvey Date 2015-11-16 Time 14:43 Sent To  
Notes
2015-11-16 14:43:22RESUB ROUTED TO CCOLE

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-11-03 Cont ID  
Sent By dharvey Date 2015-11-03 Time 10:12 Rev Time 0.00
Received By dharvey Date 2015-09-09 Time 10:09 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2015-11-17 Cont ID  
Sent By ccole Date 2015-11-17 Time 09:54 Rev Time 0.00
Received By ccole Date 2015-11-17 Time 09:54 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2015-09-15 Cont ID  
Sent By ccole Date 2015-09-15 Time 15:33 Rev Time 0.00
Received By ccole Date 2015-09-15 Time 15:33 Sent To  
Notes
2015-09-15 15:49:571ST REVIEW: FBC 2014 MECHANICAL
 PERMIT #15090268
 09/15/15
  
 1) SHEET M1: THE PLAN IS INDICATING BOTH "SMOKE
 EXHAUST" ( ON DRAWING), AND "SMOKE CONTROL"( IN
 SEQUENCE OF OPERATION NOTES) AT THE LOCATION OF THE
 MOD1: PLEASE CLARIFY.
 2) M1: INDICATE "NEW" OR "EXIST" AT THE LOCATIONS OF
 MOD1 & MOD2.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2015-09-28 Cont ID  
Sent By gjohnson Date 2015-09-28 Time 15:14 Rev Time 0.00
Received By gjohnson Date 2015-09-28 Time 15:14 Sent To  
Notes
***NONE***