| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-09-09 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-09-09 |
Time |
07:30 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-09-09 |
Time |
06:29 |
Sent To |
|
|
| Notes |
| 2015-09-09 07:31:57 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 15081111 | | | ADD: 444 BUNKER RANCH RD. | | | CONT: CURY BUILDING & DESIGN | | | TEL: (561)718-1398 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W * 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION, | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: WED. SEPT. 09/2015 | | | ACTION: DENIED | | | | | | 1) SHEET S07 CODE REFERENCE SHEET. LIST THE 2014, 5TH | | | EDITION OF THE FLORIDA BUILDING CODE. THE PLANS ARE | | | SILENT TO WHAT DESIGN THE PLANS WERE DESIGN TO UNDER | | | THE 2014 FBC-EXISTING BUILDING CODE, 301.1. | | | | | | 2) SHEET S07 STUCTURAL NOTES UNDER THE HEADING OF | | | MATERIALS THE STRENGTH OF CONCRETE IS DECLARED FOR | | | SLABS, COLUMNS AND BEAMS, SHEET S02 THE COLUMN SCHEDULE | | | UNIT C6 IS FILLED CELL MASONRY THE PLANS INDICATE THE | | | USE OF 3000 PSI CONCRETE, IN FILED CELL MASONRY | | | SHOULDN'T THE USE OF GROUT BE USED INSTEAD OF CONCRETE. | | | ACI 530 1.16.1. & TABLE 1.16.1 GROUTING MINIMUM SPACES. | | | | | | 3) SHEET S2 FOOTING SCHEDULE FOOTING F2-F6 INDICATES | | | THE WIDTH & LENGTH OF THE FOOTING BUT NOT THE HEIGTH. | | | 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 4) SHEET S2 FOOTING SCHEDULE F4 DOES NOT PROVIDE AT | | | WHAT CENTER TO CENTER IN INCHES WHAT THE STEEL MATS ARE | | | TO BE INSTALLED. 107.2.1.3 ADDITIONAL INFORMATION | | | REQUIRED. | | | | | | 5) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2015-09-24 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-09-24 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-09-24 |
Time |
15:33 |
Sent To |
I |
|
| Notes |
| 2015-09-24 16:11:43 | ELECTRICAL PROVISO TO PERMIT 15081111 | | | BEFORE POURING CONCRETE, COORDINATE WITH THE ELECTRICAL | | | CONTRACTOR ON A LOCATION FOR THE FOUNDATION GROUND AS | | | AN ELECTRICAL INSPECTION FOR THE FOUNDATION GROUNDING | | | SHALL BE PASSED BEFORE BLDG. INSPECTION IS PASSED. | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
P |
Date |
2015-11-20 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2015-11-20 |
Time |
11:31 |
Rev Time |
0.00 |
| Received By |
mgonzale |
Date |
2015-11-20 |
Time |
11:31 |
Sent To |
|
|
| Notes |
| 2015-11-20 11:31:58 | ENG HAS RECEIVED THE SEPARATE SUBMITTAL 11/2015 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2015-10-20 |
|
|
Cont ID |
|
| Sent By |
Mgonzale |
Date |
2015-10-20 |
Time |
|
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
2015-10-20 |
Time |
|
Sent To |
I |
|
| Notes |
| 2015-10-20 13:37:52 | A SEPARATE ENGINEERING SUBMITTAL IS REQUIRED. | | | | | | MANUEL JULIAN GONZALEZ | | | ENGINEERING PROJECT COORDINATOR | | | PUBLIC WORKS DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1085 | | | FAX: (561) 494-1116 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2015-09-04 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
2015-09-04 |
Time |
09:47 |
Rev Time |
0.00 |
| Received By |
mgonzale |
Date |
2015-09-04 |
Time |
09:27 |
Sent To |
|
|
| Notes |
| 2015-09-04 09:47:43 | APPLICATION IS FOR INTERIOR WORK ONLY. SHELL OF | | | BUILDING TO REMAIN. | | | | | | SEPARATE PERMIT REQUIRED FOR DUMPSTER ENCLOSURE. | | | | | | KELLY CRANFORD, P.E. | | | LAND DEVELOPMENT ENGINEER | | | PUBLIC WORKS DEPARTMENT | | | CITY OF WEST PALM BEACH | | | [email protected] | | | 561-494-1098 (OFFICE) |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2015-10-07 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2015-10-07 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2015-10-06 |
Time |
16:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2015-08-31 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2015-08-31 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2015-08-31 |
Time |
12:09 |
Sent To |
|
|
| Notes |
| 2015-08-31 12:24:38 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) THERE IS INSUFFICIENT DETAIL TO COMPLETE A PROPER OR | | | COMPLETE PLAN REVIEW. | | | | | | 2) PROVIDE DETAIL AS TO WHAT IS EXISTING AND WHAT IS | | | PROPOSED. | | | | | | 3) PROVIDE NOTE AND ENSURE ALL DRAWINGS AND WORK | | | COMPLIES: | | | | | | THE PROPOSED PROJECT SHALL MEET THE REQUIREMENTS OF THE | | | 5TH EDITION OF FLORIDA FIRE PREVENTION CODE INCLUDING | | | THE 2012 EDITION OF NFPA 1 AND NFPA 101 AND ALL OTHER | | | APPLICABLE CODES OR STANDARDS. | | | FIRE SPRINKLER WORK SHALL COMPLY WITH THE REQUIREMENTS | | | OF NFPA 13, 2010 EDITION. | | | FIRE ALARM WORK SHALL COMPLY WITH THE REQUIREMENTS OF | | | NFPA 72, 2010 EDITION. | | | CONSTRUCTION WORK SHALL COMPLY WITH THE REQUIREMENTS OF | | | NFPA 241, 2009 EDITION. | | | FIRE EXTINGUISHERS SHALL COMPLY WITH THE REQUIREMENTS | | | OF NFPA 10, 2010 EDITION. | | | ELECTRIC WORK SHALL COMPLY WITH NFPA 70, 2011 EDITION. | | | | | | 4) ADDITIONAL COMMENTS MAY APPLY BASED ON THE | | | RESUBMITTAL. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-11-05 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2015-11-05 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2015-09-28 |
Time |
08:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-09-24 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-09-24 |
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-08-28 |
Time |
13:09 |
Sent To |
I |
|
| Notes |
| 2015-09-24 16:45:36 | 9/24/15 ADDED AN ELECTRICAL PROVISO. CONTACTED RUNNER | | | VIA EMAIL. SENT TO SMALL READY BIN "C". MA | | 2015-08-28 13:15:44 | C19 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
N |
Date |
2015-10-04 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-10-04 |
Time |
07:05 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-10-04 |
Time |
06:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2015-09-01 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-09-01 |
Time |
05:36 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-09-01 |
Time |
05:22 |
Sent To |
|
|
| Notes |
| 2015-09-01 05:30:17 | 1) THE APPLICATION NOTES THIS IS FOR A FOUNDATION BUT | | | THE PLANS SHOW MUCH MORE WORK THAN A FOUNDATION. | | | INDICATE ON THE PLAN WHAT IS NEW AND WHAT IS EXISTING ( | | | GENERATOR,ELEVATOR, ETC.). WPB AMEND. TO FBC SEC. | | | 107.2.1. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2015-10-15 |
|
|
Cont ID |
|
| Sent By |
dkittred |
Date |
2015-10-15 |
Time |
10:33 |
Rev Time |
0.00 |
| Received By |
dkittred |
Date |
2015-10-15 |
Time |
09:19 |
Sent To |
|
|
| Notes |
| 2015-10-15 10:33:52 | 10/15/15 - INTERIOR WORK ONLY, SITE WORK WILL BE DONE | | | BY SEPARATE PERMIT AND ADDRESS PREVIOUS COMMENTS. DK |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2015-09-30 |
|
|
Cont ID |
|
| Sent By |
dkittred |
Date |
2015-09-30 |
Time |
15:48 |
Rev Time |
0.00 |
| Received By |
dkittred |
Date |
2015-09-30 |
Time |
15:11 |
Sent To |
|
|
| Notes |
| 2015-09-30 15:57:03 | PLANNING AND ZONING COMMENTS: ***FAILED*** | | | | | | 9/30/15 | | | | | | 1. NONE OF THE ZONING COMMENTS FROM 9/03/15 WERE | | | ADDRESSED IN THE RESUBMITTAL. PLEASE REVIEW ALL | | | PREVIOUS COMMENTS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT: | | | | | | DANIELLE J. KITTREDGE, AICP | | | SENIOR PLANNER | | | PLANNING & ZONING DIVISION | | | PHONE: (561)-822-1443 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2015-09-03 |
|
|
Cont ID |
|
| Sent By |
dkittred |
Date |
2015-09-03 |
Time |
09:43 |
Rev Time |
0.00 |
| Received By |
dkittred |
Date |
2015-09-01 |
Time |
10:22 |
Sent To |
|
|
| Notes |
| 2015-09-03 09:43:18 | PLANNING AND ZONING COMMENTS: ***FAILED*** | | | | | | 9/3/15 | | | | | | 1. SUBMIT A PROPERTY SURVEY WITH EACH SET OF PLANS. | | | | | | 2. NEW 10? X 45? CONCRETE PAD ON THE EAST SIDE OF THE | | | BUILDING NEEDS TO BE SHOWN DIMENSIONALLY ACCURATE ON | | | THE SITE PLAN WITH SETBACK FROM PROPERTY LINE. CONCRETE | | | PAD MUST BE A MINIMUM OF 2 FEET FROM THE PROPERTY LINE. | | | PLEASE DIMENSION. | | | | | | 3. LOCATION OF PROPOSED DUMPSTER IS ALSO BEING REVIEWED | | | ON SEPARATE SITE WORK PERMIT. DUMPSTER LOCATION WITH | | | ORIENTATION FOR PICK-UP OFF OF BUNKER ROAD IS NOT | | | RECOMMENDED AND WILL REQUIRE ENGINEERING REVIEW. FINAL | | | LOCATION OF THE PAD FOR THE DUMPSTER ENCLOSURE SHALL BE | | | DIMENSIONED AND INCLUDE SETBACKS FROM THE PROPERTY | | | LINE. A FOUNDATION PLANTING IS REQUIRED AROUND THE | | | DUMPSTER ENCLOSURE AND CAN BE ADDRESSED THROUGH A | | | SEPARATE LANDSCAPE PERMIT. | | | | | | | | | GENERAL COMMENTS: | | | | | | 4. REVISIONS TO PARKING LOT AND LANDSCAPING ARE TO BE | | | REVIEWED UNDER SEPARATE PERMITS. | | | | | | 5. SEPARATE PERMIT REQUIRE FOR GENERATOR. SCREENING OF | | | GENERATOR WILL BE REQUIRED. | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT: | | | | | | DANIELLE J. KITTREDGE, AICP | | | SENIOR PLANNER | | | PLANNING & ZONING DIVISION | | | PHONE: (561)-822-1443 | | | EMAIL: [email protected] | | | | | 2015-08-31 11:16:05 | 8/31/15 |
|
|