 |
Plan Review Details - Permit 15081109
| Plan Review Stops For Permit 15081109 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2016-02-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-02-02 |
Time |
06:30 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-02-02 |
Time |
06:02 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2016-01-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-01-20 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-01-20 |
Time |
07:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2015-12-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-12-29 |
Time |
13:43 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-12-29 |
Time |
11:48 |
Sent To |
|
|
| Notes |
| 2015-12-29 13:43:39 | BUILDING PLAN REVIEW | | | W.P.B. PERMIT:15081109- MASTER BUILD-OUT | | | W. P. B. PERMIT: 15081111-FOUNDATION | | | ADD: 444 BUNKER RANCH RD. | | | CONT: CURY BUILDING & DESIGN | | | TEL: (561)718-1398 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W * 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION, | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 3RD REVIEW | | | DATE: TUES. DEC. 29/2015 | | | ACTION: DENIED | | | | | | 1) 3RD REQUEST. THE RESPONSE INDICATES THE PLANS WERE | | | DESIGNED UNDER THE 2014 EXISTING BUILDING CODE, THE | | | PRESCRIPTIVE COMPLIANCE METHOD CHAPTER 4 IN THE | | | RESPONSE LETTER. BOTH THE COVERSHEET AND S7 BOTH | | | INDICATE A LEVEL III ALTERATION, THE WORK AREA METHOD | | | OF COMPLIANCE, AND CHAPTER 8THE PRESCRIPTIVE METHOD. | | | SHEET L1 ZONES 1, 2, & 3 ALL INDICATE UNDER THE HEADING | | | CLASSIFICATION OF WORK AS LEVEL III ALTERATION. | | | | | | 2014 EXISTING BUILDING CODE APPLICATION OF A METHOD | | | SHALL BE THE SOLE BASIS FOR ASSESSING THE COMPLIANCE OF | | | WORK PERFORMED UNDER A SINGLE PERMIT UNLESS OTHERWISE | | | APPROVED BY THE CODE OFFICIAL. SECTIONS 301.1.1 THROUGH | | | 301.1.3 SHALL NOT BE APPLIED IN COMBINATION WITH EACH | | | OTHER. | | | | | | THE PLANS APPEAR THAT THIS ALTERATION IS AT A MINIMUM, | | | A LEVEL III, 2014 EXST. BLDG CODE 505.1 SCOPE. LEVEL 3 | | | ALTERATIONS APPLY WHERE THE WORK AREA EXCEEDS 50 PER | | | CENT OF THE AGGREGATE AREA OF THE BUILDING. | | | THE DEMOLITION PLAN REMOVED ALL NON-BEARING WALLS ON | | | THE 2 FLOORS. SHEET S2 SHOWS THE CENTER SECTION OF THE | | | BUILDING BEING REBUILT, SHEET S3 SHOWS FLOOR JOIST | | | BEING DOUBLED THROUGHOUT THE WHOLE OF THE 2ND FLOOR, | | | SHEET S5 SHOWS NEW ELEVATOR PIT, SHAFT WALLS, THE WHOLE | | | ROOF TRUSS SYSTEM/ ROOF SHEATHING BEING INSULATED WITH | | | ICYNENE FOAM. A LEVEL III LIMITED STRUCTURAL ALTERATION | | | 907.4.3. | | | | | | 2-4) COMPLIED. | | | | | | 5) . SHEETS S1-S6 DEAL WITH THE WIND PRESSURE FOR THE | | | BUILDING. THERE IS NO WIND DESIGN CRITERIA FOR THE | | | BUILDING. SHEET S7 DEALS STRICTLY WITH THE DUMPSTER | | | ENCLOSURE AND THE WIND DESIGN PARAMETERS WILL BE | | | COMPLETELY DIFFERENT. A DIFFERENT WIND SPEED ZONE, A | | | DIFFERENT HEIGHT AND AN OPEN STRUCTURE WHEREAS THE 2 | | | STORY BUILDING IS ENCLOSED. THE PLANS WILL REQUIRE WIND | | | DESIGN CRITERIA FOR 2 STRUCTURES, A 2 STORY ENCLOSED | | | FOR SHEETS S1-S6 AND SHEET S7 FOR THE DUMPSTER | | | ENCLOSURE AN OPEN SINGLE STORY STRUCTURE WITH A LOWER | | | RISK CATEGORY AND WIND SPEED. | | | | | | | | | 5..1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND | | | GUST), MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND | | | SPEED, VASD, AS DETERMINED IN ACCORDANCE WITH SECTION | | | 1609.3.1. | | | 5.2. RISK CATEGORY. | | | 5.3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE | | | THAN ONE WIND EXPOSURE IS UTILIZED. | | | 5.4. APPLICABLE INTERNAL PRESSURE COEFFICIENT. | | | 5.5 DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR | | | COMPONENT AND CLADDING MATERIALS. | | | | | | 6-7) COMPLIED. | | | | | | 8-9) PROVISO: DEFERRED SUBMITTALS. BUILDING PROVISO/ | | | 107.3.4.2 DEFERRED SUBMITTALS: MISSING PRODUCT | | | APPROVALS: 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT | | | OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) | | | SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT | | | WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS. | | | (B) WINDOWS | | | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL | | | LOUVERS, EFIS SYSTEMS, | | | (D) ROOFING PRODUCTS AND ASSEMBLIES, CURBS FOR EXHAUST | | | FANS AND A/C ROOF TOP DOWN UNITS | | | (E) SHUTTERS | | | (F) SKYLIGHTS | | | (G) EXTERIOR COOLER, FREEZERS & PRE-ENGINEERED A/C | | | STANDS | | | | | | BUILDING PROVISO: 2010 FBC 107.3.4.1 PRODUCT APPROVALS. | | | THOSE PRODUCTS WHICH ARE REGULATED BY THE DCA RULE | | | 9N-03 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. | | | | | | 10) 3RD REQUEST. TO DATE THERE HAVE BEEN NO FIRE | | | PROTECTION PLANS SUBMITTED. THE RESPONSE LETTER | | | INDICATES TO BE PROVIDED BY APPLICANT. THE COVERSHEET | | | INDEX LIST SHEETS M1 & M2 TO INCLUDE A FIRE SPRINKLER | | | HEAD LAYOUT. NOT SHOWN. | | | | | | 10A-C)COMPLIED | | | | | | 11) COMPLIED. | | | | | | 12)3RD REQUEST. THE CITY HAS NOT RECEIVED A LETTER FROM | | | THE OWNER ON THE PROPOSED USAGE OF THIS BUILDING. IN | | | REVIEWING THE PROPOSED USE OF THIS STRUCTURE AND THE | | | LETTER FROM BETH DEWOODY STATING THE USE WOULD BE FOR | | | STORAGE PRIVATE DISPLAY FACILITY FOR PERSONAL ART AND | | | FURNITURE COLLECTION THAT WILL NOT BE OPEN TO THE | | | PUBLIC. THE DESIGNER OF RECORD HAS NOT GIVEN A PROPOSED | | | OCCUPANT LOAD. HE HAS GIVEN US THE FORMULAS IN THE CODE | | | FOR A BUSINESS OCCUPANCY. NOT THE RESTRICTED OCCUPANCY | | | THAT MS. DEWOODY HAS INDICATED WITHIN THE LETTER | | | PROVIDED TO STAFF. IT APPEARS NOT ONLY IS THERE A | | | UNKNOWN OCCUPANT LOAD FOR THE BUILDING, BUT THE A/C | | | EQUIPMENT FOUND IN THE EQUIPMENT SCHEDULE SHEET M1 | | | EXCEEDS THE CALCULATED LOADS IN THE CALCULATIONS | | | SUBMITTED FROM KO ENERGY DESIGN A DIFFERENCE OF 21.94 | | | TONS. WE ARE VERY CONCERNED THAT THIS MAY BECOME AN A3 | | | ART GALLERY VERY QUICKLY. WE WILL NEED A DATED LETTER | | | FROM MS. DEWOODY PROVIDING THE EXPLICIT USAGE OF THIS | | | SITE WILL BE IF THERE WILL EVER BE ART VIEWINGS TO THE | | | PUBLIC, FOR BY INVITATION ONLY, GALAS OR PARTIES TO | | | OCCUR AT THIS LOCATION. THE OWNER HAS ELECTED NOT TO | | | OPEN THE BUILDING TO THE PUBLIC. ON THE CERTIFICATE OF | | | COMPLETION THERE WILL BE A VERY RESTRICTIVE CLAUSE AS | | | TO USE. | | | | | | 13) 3RD REQUEST. THE 2ND REVIEW THERE 2 SHEETS | | | SUBMITTED FP1 & FP2 WHICH ARE DETAILS SHOWING | | | ACCESSIBLE ELEMENTS. NONE OF THESE ELEMENTS ARE | | | DIMENSIONED TO SHOW CODE COMPLIANCE. THERE ARE NO | | | DETAILS FOR VERTICAL ACCESSIBILITY/ ELEVATOR | | | REQUIREMENTS AND SIGNAGE. | | | | | | PLEASE PROVIDE DETAILS FOR THE ACCESSIBLE RESTROOMS | | | SHOW COMPLIANCE WITH 107.3.5.1.1 MINIMUM PLAN REVIEW | | | CRITERIA FOR COMMERCIAL BUILDINGS. ACCESSIBILITY | | | REQUIREMENTS SHALL INCLUDE THE FOLLOWING: | | | VERTICAL ACCESSIBILITY 2014 FL ACCESS CODE SECTION 407 | | | ELEVATOR | | | SINKS -BREAK ROOM AREAS. 2014 FL ACCESS CODE 606.(1-5). | | | KITCHENS AND KITCHENETTES 2014 FL ACCESS CODE 804 | | | | | | 14-16) COMPLIED. | | | | | | 17) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES | | | AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2015-11-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-11-19 |
Time |
12:38 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-11-18 |
Time |
10:45 |
Sent To |
|
|
| Notes |
| 2015-11-19 12:27:14 | BUILDING PLAN REVIEW | | | W.P.B. PERMIT:15081109- MASTER BUILD-OUT | | | W. P. B. PERMIT: 15081111-FOUNDATION | | | ADD: 444 BUNKER RANCH RD. | | | CONT: CURY BUILDING & DESIGN | | | TEL: (561)718-1398 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W * 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION, | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: WED. NOV. 18/2015 | | | ACTION: DENIED | | | | | | 2ND REQUEST. CONTRACTOR TO BIND ALL PLANS INTO A SET, | | | CIVIL, SURVEY, ARCHITECTURAL, STRUCTURAL, MECHANICAL, | | | ELECTRICAL, PLUMBING & FIRE SPRINKLER PLANS COMBINED TO | | | MAKE ONE SET. AS SUBMITTED IT LOOKS LIKE 4 SETS OF | | | CIVIL WERE SUBMITTED. AS PLAN REVIEWERS WE USUALLY LOOK | | | ONLY AT ONE SET OF PLANS, 2 SETS REQUIRED UNLESS THE | | | PROJECT IS A RESIDENT INSPECTOR OR THRESHOLD BUILDING. | | | . WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | 1) 2ND REQUEST. THE RESPONSE INDICATES THE PLANS WERE | | | DESIGNED UNDER THE 2014 EXISTING BUILDING CODE, THE | | | PRESCRIPTIVE COMPLIANCE METHOD CHAPTER 4. BOTH THE | | | COVERSHEET AND S7 BOTH INDICATE A LEVEL II ALTERATION, | | | THE WORK AREA METHOD OF COMPLIANCE, CHAPTER 8. | | | | | | THE PLANS APPEAR THAT THIS ALTERATION IS AT A MINIMUM, | | | A LEVEL III, 2014 EXST. BLDG CODE 505.1 SCOPE. LEVEL 3 | | | ALTERATIONS APPLY WHERE THE WORK AREA EXCEEDS 50 PER | | | CENT OF THE AGGREGATE AREA OF THE BUILDING. | | | THE DEMOLITION PLAN REMOVED ALL NON-BEARING WALLS ON | | | THE 2 FLOORS. SHEET S2 SHOWS THE CENTER SECTION OF THE | | | BUILDING BEING REBUILT, SHEET S3 SHOWS FLOOR JOIST | | | BEING DOUBLED THROUGH | | | | | | OUT THE WHOLE OF THE 2ND FLOOR, SHEET S5 SHOWS NEW | | | ELEVATOR PIT, SHAFT WALLS, THE WHOLE ROOF TRUSS SYSTEM/ | | | ROOF SHEATHING BEING INSULATED WITH ICYNENE FOAM. A | | | LEVEL III LIMITED STRUCTURAL ALTERATION 907.4.3. | | | | | | COMMENT FROM 1ST REVIEW. SHEET S07 CODE REFERENCE | | | SHEET. LIST THE 2014, 5TH EDITION OF THE FLORIDA | | | BUILDING CODE. THE PLANS ARE SILENT TO WHAT DESIGN THE | | | PLANS WERE DESIGN TO UNDER THE 2014 FBC-EXISTING | | | BUILDING CODE, 301.1. | | | | | | 2) ???????????? SHEET S07 STRUCTURAL NOTES UNDER THE | | | HEADING OF MATERIALS THE STRENGTH OF CONCRETE IS | | | DECLARED FOR SLABS, COLUMNS AND BEAMS, SHEET S02 THE | | | COLUMN SCHEDULE UNIT C6 IS FILLED CELL MASONRY THE | | | PLANS INDICATE THE USE OF 3000 PSI CONCRETE, IN FILED | | | CELL MASONRY SHOULDN'T THE USE OF GROUT BE USED INSTEAD | | | OF CONCRETE. ACI 530 1.16.1. & TABLE 1.16.1 GROUTING | | | MINIMUM SPACES. | | | | | | 3) COMPLIED. SHEET S2 FOOTING SCHEDULE FOOTING F2-F6 | | | INDICATES THE WIDTH & LENGTH OF THE FOOTING BUT NOT THE | | | HEIGHT. 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 4) COMPLIED. SHEET S2 FOOTING SCHEDULE F4 DOES NOT | | | PROVIDE AT WHAT CENTER TO CENTER IN INCHES WHAT THE | | | STEEL MATS ARE TO BE INSTALLED. 107.2.1.3 ADDITIONAL | | | INFORMATION REQUIRED. | | | | | | 5) SHEET S-7 INDICATES THE PLANS WERE DESIGNED TO THE | | | 2014 FBC-B AND ASCE 7-10. THE WIND DESIGN CRITERIA IS | | | NOT PROVIDED. 2014 FBC-B 1603.1.4 WIND DESIGN DATA. | | | THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL | | | BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE | | | DESIGN OF THE LATERAL FORCE RESISTING SYSTEM OF THE | | | STRUCTURE: | | | | | | 5.1.COMPLIED. ULTIMATE DESIGN WIND SPEED, VULT, | | | (3-SECOND GUST), MILES PER HOUR (KM/HR) AND NOMINAL | | | DESIGN WIND SPEED, VASD, AS DETERMINED IN ACCORDANCE | | | WITH SECTION 1609.3.1. | | | 5.2. COMPLIED. RISK CATEGORY. | | | 5.3.COMPLIED. WIND EXPOSURE. APPLICABLE WIND DIRECTION | | | IF MORE THAN ONE WIND EXPOSURE IS UTILIZED. | | | 5.4. COMPLIED. APPLICABLE INTERNAL PRESSURE | | | COEFFICIENT. | | | 5.5.SEMI-COMPLIED. DESIGN WIND PRESSURES TO BE USED FOR | | | EXTERIOR COMPONENT AND CLADDING MATERIALS NOT | | | SPECIFICALLY DESIGNED BY THE REGISTERED DESIGN | | | PROFESSIONAL RESPONSIBLE FOR THE DESIGN OF THE | | | STRUCTURE, PSF (KN/M2).SHEETS S1-S6 DEAL WITH THE WIND | | | PRESSUE | | | | | | | | | | | | 6) 2ND REQUEST. SHEET S7 & S1. MEAN ROOF HEIGHT GIVEN | | | 27?-10?. SHEET S1 ELEVATIONS WITH PRESSURES. | | | | | | 6A) ES WINDOWS SERIES ?1500? NOA. 14-0923.08 WILL NEED | | | TO IDENTIFY EITHER A/C OR B/C TYPE OF FASTENERS. NOTE | | | WINDOW TYPE 6 FOR EXAMPLE (3) 4?X7? WINDOWS 48?X 84?. | | | A/C TYPE FASTENERS ARE ONLY GOOD FOR +/- 36 PSF. IF B/C | | | TYPE OF FASTENER IS USED, GOOD FOR ALL TYPE OF | | | INSTALLATIONS. PLEASE IDENTIFY FASTENER TYPE. | | | | | | 6B) ES WINDOWS TUBE MULLION NOA 14-0731.06 WILL NEED TO | | | IDENTIFY ANCHOR TYPES, SOME TYPES OF ANCHORS HAVE LOW | | | PRESSURES. IDENTIFY WINDOW DIMENSIONS AND MULLION SIZES | | | AND LENGTH. | | | | | | 6C) E S WINDOWS SERIES 9000 ALUMINUM OUTSWING FRENCH | | | DOORS NOA 130617.29 PRESSURES ARE GOOD. | | | 6C)(1) SHEET S1 FRONT ENTRY DOOR, NORTH ELEVATION(A) IS | | | INDICATED AS 9?-4? WIDE. TYPO? THERE IS NO DOOR FRAME | | | THAT WIDE IN THE PRODUCT APPROVAL REPORT. | | | 6C)(2) SHEET S1 SOUTH ELEVATION DOOR C IS INDICATED AS | | | 5?-8? WIDE. SHEET L1 INDICATES THIS SET OF DOORS IS | | | EXIT # 4. THE 2014 FBC-B 1008.1.1 SIZE OF DOOR IS 32 | | | INCHES CLEAR OPENING MEASURED FROM FACE OF DOOR TO | | | OPPOSITE STOP WHEN THE DOOR IS OPEN AT 90 DEGREES. | | | | | | 7) SEE COMMENT 5.5 .SHEET S7 & S4. PROVIDE THE MEAN | | | ROOF HEIGHT AND SECTION THROUGH THE ROOF WITH ELEVATION | | | OF ROOF AND OF THE PARAPET. THE MEAN ROOF HEIGHT CAN | | | NOT BE DETERMINED , NOR CAN THE PRESSURES FOR ROOF | | | ZONES, NOTE THE PRESSURES ARE ASSUMED TO BE VASD? 2014 | | | FBC-B TABLE 1609.7(2) ADJUSTMENT FACTORS FOR BUILDING | | | HEIGHT AND EXPOSURE. | | | | | | 8)BUILDING PROVISO/ 107.3.4.2 DEFERRED SUBMITTALS: | | | MISSING PRODUCT APPROVALS: 2010 FBC-B 1609.1.2 | | | PROTECTION OF OPENINGS, 1609.6.4.4.1 COMPONENTS & | | | CLADDING. FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE | | | 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR | | | CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT | | | APPROVALS: | | | (31)(A) EXTERIOR DOORS. | | | (B) WINDOWS | | | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL | | | LOUVERS, EFIS SYSTEMS, | | | (D) ROOFING PRODUCTS AND ASSEMBLIES, CURBS FOR EXHAUST | | | FANS AND A/C ROOF TOP DOWN UNITS | | | (E) SHUTTERS | | | (F) SKYLIGHTS | | | (G) EXTERIOR COOLER, FREEZERS & PRE-ENGINEERED A/C | | | STANDS | | | | | | 9)BUILDING PROVISO: 2010 FBC 107.3.4.1 PRODUCT | | | APPROVALS. THOSE PRODUCTS WHICH ARE REGULATED BY THE | | | DCA RULE 9N-03 SHALL BE REVIEWED AND APPROVED IN | | | WRITING BY THE DESIGNER OF RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL. | | | | | | 10) TODATE THERE HAVE BEEN NO FIRE PROTECTION PLANS | | | SUBMITTED. | | | | | | 10A) 2ND REQUEST. SEE MECHANICAL RESPONSE AS TO | | | LOCATION OF EXHAUST FROM KITCHEN HOOD, THERE MAYBE | | | STILL ISSUES AS TO WHERE THE FINAL LOCATION OF THE HOOD | | | EXHAUST. SHEET S3 ROOF FRAMING PLAN DOES NOT PROVIDE A | | | SECTION FOR THE ROOF FRAMING AND HEADER FOR THE NEW | | | EXHAUST VENT THAT WILL GO THROUGH THE ROOF FRAMING AND | | | SHEATHING. NOTE THERE IS ALSO NO ROOF TOP CURB DETAIL, | | | HOW IT IS TO BE ANCHORED TO THE ROOF FRAMING. | | | 1609.6.4.4.1 COMPONENTS & CLADDING. | | | | | | 10B) MAY STILL HAVE ISSUES DEPENDING ON THE HOOD | | | EXHAUST LOCATION. WITH THE LOCATION OF THE EXHAUST FAN | | | NOT PROVIDED NOR THE HEIGHT OF THE PARAPET PLEASE SHOW | | | COMPLIANCE WITH 2014 FBC-B 1013.6 MECHANICAL EQUIPMENT. | | | GUARDS SHALL BE PROVIDED WHERE APPLIANCES, EQUIPMENT, | | | FANS, ROOF HATCH OPENINGS OR OTHER COMPONENTS THAT | | | REQUIRE SERVICE ARE LOCATED WITHIN 10 FEET (3048 MM) OF | | | A ROOF EDGE OR OPEN SIDE OF A WALKING SURFACE AND SUCH | | | EDGE OR OPEN SIDE IS LOCATED MORE THAN 30 INCHES (762 | | | MM) ABOVE THE FLOOR, ROOF OR GRADE BELOW. THE GUARD | | | SHALL BE CONSTRUCTED SO AS TO PREVENT THE PASSAGE OF A | | | SPHERE 21 INCHES (533 MM) IN DIAMETER. THE GUARD SHALL | | | EXTEND NOT LESS THAN 30 INCHES (762 MM) BEYOND EACH END | | | OF SUCH APPLIANCE, EQUIPMENT, FAN OR COMPONENT. | | | | | | COMPLIED. 1013.7 ROOF ACCESS. GUARDS SHALL BE PROVIDED | | | WHERE THE ROOF HATCH OPENING IS LOCATED WITHIN 10 FEET | | | (3048 MM) OF A ROOF EDGE OR OPEN SIDE OF A WALKING | | | SURFACE AND SUCH EDGE OR OPEN SIDE IS LOCATED MORE THAN | | | 30 INCHES (762 MM) ABOVE THE FLOOR, ROOF OR GRADE | | | BELOW. THE GUARD SHALL BE CONSTRUCTED SO AS TO PREVENT | | | THE PASSAGE OF A SPHERE 21 INCHES (533 MM) IN DIAMETER. | | | | | | 10C) MAY STILL HAVE ISSUES DEPENDING ON THE HOOD | | | EXHAUST LOCATION. PLEASE REVIEW THE REQUIREMENTS FOR | | | SCREENS FOR MECHANICAL EQUIPMENT. 1509.6 MECHANICAL | | | EQUIPMENT SCREENS. MECHANICAL EQUIPMENT SCREENS SHALL | | | BE CONSTRUCTED OF THE MATERIALS SPECIFIED FOR THE | | | EXTERIOR WALLS IN ACCORDANCE WITH THE TYPE OF | | | CONSTRUCTION OF THE BUILDING. WHERE THE FIRE SEPARATION | | | DISTANCE IS GREATER THAN 5 FEET (1524 MM), MECHANICAL | | | EQUIPMENT SCREENS SHALL NOT BE REQUIRED TO COMPLY WITH | | | THE FIRE-RESISTANCE RATING REQUIREMENTS. | | | | | | 11)2ND REQUEST. SHEET L1 & L2 SHOWS A 1 HOUR WALL AND | | | INTERIOR PARTITION FILE NUMBER GA FILE WP 1072. | | | THERE ARE NO CUT SECTIONS THROUGH THE STAIRWELL | | | PROVIDING HOW THE WOOD FRAMING MEMBERS FOR THE 2ND | | | FLOOR SYSTEM AND ROOF SYSTEM ARE TO BE INCORPORATED | | | INTO THE SHAFT WALL CONSTRUCTION. 2010 FBC-B 713.8 | | | PENETRATIONS. STRUCTURAL ELEMENTS, SUCH AS BEAMS OR | | | JOIST WHERE PROTECTED IN ACCORDANCE WITH 714 SHALL BE | | | PERMITTED TO PENETRATE A SHAFT ENCLOSURE. PLEASE | | | PROVIDE ADDITIONAL INFORMATION FOR CODE COMPLIANCE. | | | | | | 11B) SHEET S6 EAST STAIR 2/S6. THIS STAIR SHOWS A RISER | | | # 24 THAT IS ABOVE THE FINISH FLOOR LEVEL. RISER # 24 | | | IS ALSO A THIRD LARGER THAN THE REST OF THE RISERS | | | 1009.7.4 DIMENSIONAL UNIFORMITY. | | | THIS SAME DETAIL SHOWS A 18X18 RATED DAMPER FOR THE | | | SECOND FLOOR CEILING AND DIRECTED TO THE FLOOR. THE | | | PLANS ALSO SHOW A 12X12 RAG NO DAMPER. | | | | | | 11C) BOTH THE EAST AND WEST STAIR SHOW ON M2 SUPPLY | | | DUCTS INTO BOTH STAIRWELLS. 2014 FBC-B 1022.5 | | | PENETRATIONS . PENETRATIONS ARE PROHIBITED EXCEPT FOR | | | REQUIRED EXIT DOORS, EQUIPMENT AND DUCTWORK NECESSARY | | | FOR INDEPENDENT VENTILATION OR PRESSURIZATION OF THE | | | STAIRWELL. | | | | | | 11D) SHEET L2 EAST STAIRWELL THE 2ND FLOOR LANDING | | | SHOWS A DOOR IN THE STAIRWELL THAT OPENS INTO A | | | MECHANICAL ROOM. 2014 FBC-B 1022.5 PENETRATIONS . | | | PENETRATIONS ARE PROHIBITED EXCEPT FOR REQUIRED EXIT | | | DOORS. DOORS THAT LED INTO STAIRWELLS HAVE TO BE FROM | | | HABITABLE SPACES, EGRESS DOORS ONLY! | | | | | | 11E) SHEET S6 BOTH THE EAST AND WEST STAIR ENCLOSURE | | | ONLY SHOW A HANDRAIL ONLY ON ONE SIDE. 2014 FBC-B | | | 1009.15. HAND RAILS ARE REQUIRED ON BOTH SIDES. | | | | | | COMMENT 1ST REVIEW. SHEET L1 & L2 WHAT APPEARS TO BE | | | FIRE RATED VERTICAL EXIT STAIRS NEITHER LIFE SAFETY | | | SHEET DO NOT PROVIDE WALL IDENTIFICATION TAGS SHOWING | | | THE TYPE OF WALL OR IF FIRE RATINGS, MISSING UL LISTING | | | OF STAIR ENCLOSURE. 2014 FBC-B 1023.3 CONSTRUCTION. | | | 1023.6 PENETRATIONS. GUARDS | | | | | | 12 IN REVIEWING THE PROPOSED USE OF THIS STRUCTURE AND | | | THE LETTER FROM BETH DEWOODY STATING THE USE WOULD BE | | | FOR STORAGE PRIVATE DISPLAY FACILITY FOR PERSONAL ART | | | AND FURNITURE COLLECTION THAT WILL NOT BE OPEN TO THE | | | PUBLIC. THE DESIGNER OF RECORD HAS NOT GIVEN A PROPOSED | | | OCCUPANT LOAD. HE HAS GIVEN US THE FORMULAS IN THE CODE | | | FOR A BUSINESS OCCUPANCY. NOT THE RESTRICTED OCCUPANCY | | | THAT MS. DEWOODY HAS INDICATED WITHIN THE LETTER | | | PROVIDED TO STAFF. IT APPEARS NOT ONLY IS THERE A | | | UNKNOWN OCCUPANT LOAD FOR THE BUILDING, BUT THE A/C | | | EQUIPMENT FOUND IN THE EQUIPMENT SCHEDULE SHEET M1 | | | EXCEEDS THE CALCULATED LOADS IN THE CALCULATIONS | | | SUBMITTED FROM KO ENERGY DESIGN A DIFFERENCE OF 21.94 | | | TONS. WE ARE VERY CONCERNED THAT THIS MAY BECOME AN A3 | | | ART GALLERY VERY QUICKLY. WE WILL NEED A DATED LETTER | | | FROM MS. DEWOODY PROVIDING THE EXPLICIT USAGE OF THIS | | | SITE WILL BE IF THERE WILL EVER BE ART VIEWINGS TO THE | | | PUBLIC, FOR BY INVITATION ONLY, GALAS OR PARTIES TO | | | OCCUR AT THIS LOCATION. THE OWNER HAS ELECTED NOT TO | | | OPEN THE BUILDING TO THE PUBLIC. ON THE CERTIFICATE OF | | | COMPLETION THERE WILL BE A VERY RESTRICTIVE CLAUSE AS | | | TO USE. | | | | | | 1ST COMMENTS. SHEET L1 & L2 THERE IS NO DOOR SCHEDULE | | | TO BE ABLE TO IDENTIFY DOOR OPENINGS. 107.2.1.3 | | | ADDITIONAL INFORMATION IS REQUIRED. 107.3.5.1.1 MINIMUM | | | PLAN REVIEW CRITERIA FOR COMMERCIAL BUILDINGS. | | | | | | OCCUPANCY LOAD/EGRESS REQUIREMENTS SHALL INCLUDE: | | | OCCUPANCY LOAD | | | GROSS | | | NET | | | MEANS OF EGRESS | | | EXIT ACCESS | | | EXIT | | | EXIT DISCHARGE | | | STAIRS CONSTRUCTION/GEOMETRY AND PROTECTION | | | DOORS | | | EMERGENCY LIGHTING AND EXIT SIGNS | | | CONSTRUCTION REQUIREMENTS | | | | | | 13) 2ND REQUEST. THE 2ND REVIEW THERE 2 SHEETS | | | SUBMITTED FP1 & FP2 WHICH ARE DETAILS SHOWING | | | ACCESSIBLE ELEMENTS. NONE OF THESE ELEMENTS ARE | | | DIMENSIONED TO SHOW CODE COMPLIANCE. THERE ARE NO | | | DETAILS FOR VERTICAL ACCESSIBILITY/ ELEVATOR | | | REQUIREMENTS AND SIGNAGE. | | | | | | PLEASE PROVIDE DETAILS FOR THE ACCESSIBLE RESTROOMS | | | SHOW COMPLIANCE WITH 107.3.5.1.1 MINIMUM PLAN REVIEW | | | CRITERIA FOR COMMERCIAL BUILDINGS. ACCESSIBILITY | | | REQUIREMENTS SHALL INCLUDE THE FOLLOWING: | | | VERTICAL ACCESSIBILITY 2014 FL ACCESS CODE SECTION 407 | | | ELEVATOR | | | TOILET AND BATHING FACILITIES 2014 FL ACCESS CODE | | | CHAPTER 6 | | | DRINKING FOUNTAINS 2014 FL ACCESS CODE 602 | | | SINKS -BREAK ROOM AREAS. 2014 FL ACCESS CODE 606.(1-5). | | | KITCHENS AND KITCHENETTES 2014 FL ACCESS CODE 804 | | | | | | 14) 2ND REQUEST. SHEET LS2 INDICATES A THEATER IN ROOM | | | 210 PLEASE PROVIDE ADDITIONAL DETAILS, SEAT LAYOUT. | | | THIS REVIEW THERE IS A SEATING LAYOUT BUT NO THOUGHT | | | WAS GIVEN TO 2014 FL. ACCESS. CODE FOR COMPANION | | | SEATING. 802.3. | | | | | | 15) SHEET S6 SHOWS THE USE OF SPRAYED IN ICYNENE ROOF | | | INSULATION TO A VALUE OF R-20. THE PLANS APPEAR NOT TO | | | HAVE A CEILING BUT A OPEN RAFTER CONCEPT. PLEASE | | | PROVIDE COMPLIANCE WITH 2014 FBC-B 2603.4 THERMAL | | | BARRIER OR AN EXCEPTION. THE PLEASE PROVIDE THE TESTING | | | FOR ICYNENE FOR USE AND LIMITATIONS. | | | | | | 16) THE ENERGY CALCULATIONS ALSO SHOW THE USE OF ? INCH | | | ISO BETWEEN FURRING STRIPS @ 24 INCHES ON CENTER AND | | | USE OF 5/8 GYPSUM, PLEASE PROVIDE THE SHEET AND DETAIL | | | WHERE THIS INSTALLATION CAN BE FOUND IN THE PLANS. | | | | | | 17) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES | | | AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A | | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | | THIS REVIEW. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-09-09 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2015-09-09 |
Time |
12:28 |
Rev Time |
|
| Received By |
|
Date |
2015-09-09 |
Time |
08:25 |
Sent To |
|
|
| Notes |
| 2015-09-09 08:25:28 | BUILDING PLAN REVIEW | | | W.P.B. PERMIT:15081109- MASTER | | | W. P. B. PERMIT: 15081111-FOUNDATION | | | ADD: 444 BUNKER RANCH RD. | | | CONT: CURY BUILDING & DESIGN | | | TEL: (561)718-1398 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W * 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION, | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: WED. SEPT. 09/2015 | | | ACTION: DENIED | | | | | | CONTRACTOR TO BIND ALL PLANS INTO A SET, CIVIL, SURVEY | | | AND CIVIL, ARCHITECTURAL, STRUCTURAL, MECHANICAL, | | | ELECTRICAL & PLUMBING COMBINED TO MAKE ONE SET. AS | | | SUBMITTED IT LOOKS LIKE 4 SETS OF CIVIL WERE SUBMITTED. | | | AS PLAN REVIEWERS WE USUALLY LOOK ONLY AT ONESET OF | | | PLANS. WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES | | | AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | 1) SHEET S07 CODE REFERENCE SHEET. LIST THE 2014, 5TH | | | EDITION OF THE FLORIDA BUILDING CODE. THE PLANS ARE | | | SILENT TO WHAT DESIGN THE PLANS WERE DESIGN TO UNDER | | | THE 2014 FBC-EXISTING BUILDING CODE, 301.1. | | | | | | 2) SHEET S07 STUCTURAL NOTES UNDER THE HEADING OF | | | MATERIALS THE STRENGTH OF CONCRETE IS DECLARED FOR | | | SLABS, COLUMNS AND BEAMS, SHEET S02 THE COLUMN SCHEDULE | | | UNIT C6 IS FILLED CELL MASONRY THE PLANS INDICATE THE | | | USE OF 3000 PSI CONCRETE, IN FILED CELL MASONRY | | | SHOULDN'T THE USE OF GROUT BE USED INSTEAD OF CONCRETE. | | | ACI 530 1.16.1. & TABLE 1.16.1 GROUTING MINIMUM SPACES. | | | | | | 3) SHEET S2 FOOTING SCHEDULE FOOTING F2-F6 INDICATES | | | THE WIDTH & LENGTH OF THE FOOTING BUT NOT THE HEIGTH. | | | 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 4) SHEET S2 FOOTING SCHEDULE F4 DOES NOT PROVIDE AT | | | WHAT CENTER TO CENTER IN INCHES WHAT THE STEEL MATS ARE | | | TO BE INSTALLED. 107.2.1.3 ADDITIONAL INFORMATION | | | REQUIRED. | | | | | | 5) SHEET S-7 INDICATES THE PLANS WERE DESIGNED TO THE | | | 2014 FBC-B AND ASCE 7-10. THE WIND DESIGN CRITERIA IS | | | NOT PROVIDED. 2014 FBC-B 1603.1.4 WIND DESIGN DATA. | | | THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL | | | BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE | | | DESIGN OF THE LATERAL FORCERESISTING SYSTEM OF THE | | | STRUCTURE: | | | | | | 5.1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST), | | | MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED, | | | VASD, AS DETERMINED IN ACCORDANCE WITH SECTION | | | 1609.3.1. | | | 5.2. RISK CATEGORY. | | | 5.3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE | | | THAN ONE WIND EXPOSURE IS UTILIZED. | | | 5.4. APPLICABLE INTERNAL PRESSURE COEFFICIENT. | | | 5.5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR | | | COMPONENT AND CLADDING MATERIALS NOT SPECIFICALLY | | | DESIGNED BY THE REGISTERED DESIGN | | | PROFESSIONAL RESPONSIBLE FOR THE DESIGN OF THE | | | STRUCTURE, PSF (KN/M2). | | | | | | 6) SHEET S7 & S1. PROVIDE THE MEAN ROOF HEIGTH AND | | | SECTION THROUGH THE ROOF WITH ELEVATION OF ROOF AND OF | | | THE PARAPET. THE MEAN ROOF HEIGHT CAN NOT BE DETERMINED | | | , NOR CAN THE PRESSURES FOR WINDOWS AND DOORS . 2014 | | | FBC-B TABLE 1609.7(2) ADJUSTMENT FACTORS FOR BUILDING | | | HEIGHT AND EXPOSURE. | | | | | | 7) SHEET S7 & S4. PROVIDE THE MEAN ROOF HEIGTH AND | | | SECTION THROUGH THE ROOF WITH ELEVATION OF ROOF AND OF | | | THE PARAPET. THE MEAN ROOF HEIGHT CAN NOT BE DETERMINED | | | , NOR CAN THE PRESSURES FOR ROOF ZONES, NOTE THE | | | PRESSURES ARE ASSUMED TO BE VASD? 2014 FBC-B TABLE | | | 1609.7(2) ADJUSTMENT FACTORS FOR BUILDING HEIGHT AND | | | EXPOSURE. | | | | | | 8) MISSING PRODUCT APPROVALS: 2010 FBC-B 1609.1.2 | | | PROTECTION OF OPENINGS, 1609.6.4.4.1 COMPONENTS & | | | CLADDING. FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE | | | 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR | | | CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT | | | APPROVALS: | | | (31)(A) EXTERIOR DOORS. | | | (B) WINDOWS | | | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL | | | LOUVERS, EFIS SYSTEMS, | | | (D) ROOFING PRODUCTS AND ASSEMBLIES, CURBS FOR EXHAUST | | | FANS AND A/C ROOF TOP DOWN UNITS | | | (E) SHUTTERS | | | (F) SKYLIGHTS | | | (G) EXTERIOR COOLER, FREEZERS & PRE-ENGINEERED A/C | | | STANDS | | | | | | 9A) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE | | | PRODUCTS WHICH ARE REGULATED BY THE DCA RULE 9N-03 | | | SHALL BE REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. | | | | | | 9B) EITHER THE CONTRACTOR OR DESIGN PROFESSIONAL CAN | | | ELECT TO DEFER THE PRODUCT APPROVALS TO AFTER PERMIT | | | ISSUANCE, IF SO PLEASE PROVIDE A WRITTEN RESPONSE. | | | 107.3.4.2 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS | | | SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE | | | PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE | | | TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO | | | THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. | | | DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR | | | APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED | | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST | | | THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS | | | FOR REVIEW BY THE BUILDING OFFICIAL. DOCUMENTS FOR | | | DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE | | | REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE | | | WHO SHALL REVIEW THEM AND FORWARD THEM TO THE BUILDING | | | OFFICIAL WITH A NOTATION INDICATING THAT THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED AND FOUND TO BE | | | IN GENERAL CONFORMANCE TO THE DESIGN OF THE BUILDING. | | | THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED | | | UNTIL THE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN | | | APPROVED BY THE BUILDING OFFICIAL. | | | | | | 10) THERE ARE NO A SHEETS, MECHANICAL NO FP SHEETS | | | SHOWING THE ROOF DECK, THE M2 SHEET SHOWS A COMMERCIAL | | | GAS STOVE AND S4 INDICATES THE KITCHEN HOOD EXHAUST BY | | | OTHER. SHEET S6 DETAIL # 4 SHOWS A NEW ROOF TOP ACCESS | | | WITH ROOF TOP DOOR. | | | | | | 10A) SHEET S3 ROOF FRAMING PLANDOES NOT PROVIDE A | | | SECTION FOR THE ROOF FRAMNG AND HEADER FOR THE NEW | | | EXHAUST VENT THAT WILL GO THROUGH THE ROOF FRAMING AND | | | SHEATHING. NOTE THERE IS ALSO NO ROOF TOP CURB DETAIL, | | | HOW IT IS TO BE ANCHORED TO THE ROOF FRAMING. | | | 1609.6.4.4.1 COMPONENTS & CLADDING. | | | | | | 10B) WITH THE LOCATION OF THE EXHAUST FAN NOT PROVIDED | | | NOR THE HEIGHT OF THE PARAPET PLEASE SHOW COMPLIANCE | | | WITH 2014 FBC-B 1013.6 MECHANICAL EQUIPMENT. GUARDS | | | SHALL BE PROVIDED WHERE APPLIANCES, EQUIPMENT, FANS, | | | ROOF HATCH OPENINGS OR OTHER COMPONENTS THAT REQUIRE | | | SERVICE ARE LOCATED WITHIN 10 FEET (3048 MM) OF A ROOF | | | EDGE OR OPEN SIDE OF A WALKING SURFACE AND SUCH EDGE OR | | | OPEN SIDE IS LOCATED MORE THAN 30 INCHES (762 MM) ABOVE | | | THE FLOOR, ROOF OR GRADE BELOW. THE GUARD SHALL BE | | | CONSTRUCTED SO AS TO PREVENT THE PASSAGE OF A SPHERE 21 | | | INCHES (533 MM) IN DIAMETER. THE GUARD SHALL EXTEND NOT | | | LESS THAN 30 INCHES (762 MM) BEYOND EACH END OF SUCH | | | APPLIANCE, EQUIPMENT, FAN OR COMPONENT. | | | | | | 1013.7 ROOF ACCESS. GUARDS SHALL BE PROVIDED WHERE THE | | | ROOF HATCH OPENING IS LOCATED WITHIN 10 FEET (3048 MM) | | | OF A ROOF EDGE OR OPEN SIDE OF A WALKING SURFACE AND | | | SUCH EDGE OR OPEN SIDE IS LOCATED MORE THAN 30 INCHES | | | (762 MM) ABOVE THE FLOOR, ROOF OR GRADE BELOW. THE | | | GUARD SHALL BE CONSTRUCTED SO AS TO PREVENT THE PASSAGE | | | OF A SPHERE 21 INCHES (533 MM) IN DIAMETER. | | | | | | 10C) PLEASE REVIEW THE REQUIREMENTS FOR SCREENS FOR | | | MECHANICAL EQUIPMENT. 1509.6 MECHANICAL EQUIPMENT | | | SCREENS. MECHANICAL EQUIPMENT SCREENS SHALL BE | | | CONSTRUCTED OF THE MATERIALS SPECIFIED FOR THE EXTERIOR | | | WALLS IN ACCORDANCE WITH THE TYPE OF CONSTRUCTION OF | | | THE BUILDING. WHERE THE FIRE SEPARATION DISTANCE IS | | | GREATER THAN 5 FEET (1524 MM), MECHANICAL EQUIPMENT | | | SCREENS SHALL NOT BE REQUIRED TO COMPLY WITH THE | | | FIRE-RESISTANCE RATING REQUIREMENTS. | | | | | | 11) SHEET L1 & L2 WHAT APPEARS TO BE FIRE RATED | | | VERTICAL EXIT STAIRS NEITHER LIFE SAFETY SHEET DO NOT | | | PROVIDE WALL IDENTIFICATION TAGS SHOWING THE TYPE OF | | | WALL OR IF FIRE RATINGS, MISSING UL LISTING OF STAIR | | | ENCLOSUE. 2014 FBC-B 1023.3 CONSTRUCTION. 1023.6 | | | PENETRATIONS. GAURDS | | | | | | 12) SHEET L1 & L2 THERE IS NO DOOR SCHEDULE TO BE ABLE | | | TO IDENTIFY DOOR OPENINGS. 107.2.1.3 ADDITIONAL | | | INFORMATION IS REQUIRED. 107.3.5.1.1 MINIMUM PLAN | | | REVIEW CRITERIA FOR COMMERCIAL BUILDINGS. | | | | | | OCCUPANCY LOAD/EGRESS REQUIREMENTS SHALL INCLUDE: | | | OCCUPANCY LOAD | | | GROSS | | | NET | | | MEANS OF EGRESS | | | EXIT ACCESS | | | EXIT | | | EXIT DISCHARGE | | | STAIRS CONSTRUCTION/GEOMETRY AND PROTECTION | | | DOORS | | | EMERGENCY LIGHTING AND EXIT SIGNS | | | CONSTRUCTION REQUIREMENTS | | | | | | 13) PLEASE PROVIDE DETAILS FOR THE ACCESSIBLE RESTROOMS | | | SHOW COMPLIANCE WITH 107.3.5.1.1 MINIMUM PLAN REVIEW | | | CRITERIA FOR COMMERCIAL BUILDINGS. ACCESSIBILITY | | | REQUIREMENTS SHALL INCLUDE THE FOLLOWING: | | | VERTICAL ACCESSIBILITY 2014 FL ACCESS CODE SECTION 407 | | | ELEVATOR | | | TOILET AND BATHING FACILITIES 2014 FL ACCESS CODE | | | CHAPTER 6 | | | DRINKING FOUNTAINS 2014 FL ACCESS CODE 602 | | | SINKS -BREAK ROOM AREAS. 2014 FL ACCESS CODE 606.(1-5). | | | | | | 14) SHEET LS2 INDICATES A THEATER IN ROOM 210 PLEASE | | | PROVIDE ADDITIONAL DETAILS, SEAT LAYOUT, STADIUM STYE | | | RAISED TIERS? ADDITIONAL INFORMATION IS REQUIRED FOR | | | CODE COMPLIANCE. | | | | | | 15) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES | | | AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A | | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | | THIS REVIEW. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2016-02-04 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2016-02-04 |
Time |
08:56 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2016-02-04 |
Time |
08:56 |
Sent To |
|
|
| Notes |
| 2016-02-04 09:03:38 | THE ADDITIONAL ELECTRICAL SUBMITTAL IS RELATIVE TO SITE | | | LIGHTING. SITE LIGHTING IS NOT PART OF THIS REVIEW AND | | | SHALL REQUIRE A SEPARATE SUBMITTAL TO INCLUDING THE | | | SITE ELECTRICAL PAGE, AND ADDITIONALL INFORMATION ON | | | LUMINARES, AND POLES WITH WIND ANALYSIS. ADDITIONALLY, | | | PHOTOMETRICS IS REQUIRED. IT SHOULD BE SUBMITTED AS AN | | | ELECTRICAL PERMIT REQUESTED TO BE SENT TO DANIELLE | | | KITTREDGE IN THE PLANNING & ZONING DIVISION. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2016-01-25 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2016-01-25 |
Time |
19:49 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2016-01-25 |
Time |
19:06 |
Sent To |
|
|
| Notes |
| 2016-01-25 19:50:36 | ALL PREVIOUSLY ADDRESSED DEFICIENCIES HAVE BEEN | | | SATISFACTORILY ADDRESSED. FILE SENT BACK TO "C31" FOR | | | FURTHER REVIEWS. MA |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2016-01-04 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2016-01-04 |
Time |
15:41 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2016-01-04 |
Time |
14:05 |
Sent To |
I |
|
| Notes |
| 2016-01-04 15:43:20 | I DISCUSSED THE LABELING CORRECTIONS W/MR/ S.SINCLAIR. | | | WAITING FOR NEW SHEETS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2015-12-03 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-12-03 |
Time |
17:22 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-12-03 |
Time |
15:21 |
Sent To |
I |
|
| Notes |
| 2015-12-03 17:23:28 | THE PLANS FOR THE ABOVE MENTIONED PERMIT APPLICATION | | | HAVE BEEN REVIEWED FOR COMPLIANCE WITH THE EDITION OF | | | THE NEC, (NATIONAL ELECTRICAL CODE) AND THE FBC, | | | (FLORIDA BUILDING CODE) AS WELL AS THE CITY OF WEST | | | PALM BEACH AMENDMENTS IN EFFECT AT THE TIME OF | | | SUBMITTAL. BELOW IS A LIST OF THE DEFICIENCIES NOTED. | | | | | | 1. NEC 600.5 REQUIRED BRANCH CIRCUIT. EACH COMMERCIAL | | | BUILDING AND EACH COMMERCIAL OCCUPANCY ACCESSIBLE TO | | | PEDESTRIANS SHALL BE PROVIDED WITH AT LEAST ONE 20 AMP | | | DEDICATED OUTLET IN AN ACCESSIBLE LOCATION AT EACH | | | ENTRANCE TO EACH TENANT SPACE FOR SIGN OR OUTLINE | | | LIGHTING. SERVICE HALLWAYS OR CORRIDORS SHALL NOT BE | | | CONSIDERED ACCESSIBLE TO PEDESTRIANS. | | | 2. NEC 210.62 SHOW WINDOWS. AT LEAST ONE RECEPTACLE | | | OUTLET SHALL BE INSTALLED WITHIN 18? OF THE TOP OF A | | | SHOW WINDOW FOR EVERY 12 LINEAR FT. OR MAJOR PORTION | | | THEREOF AREA MEASURED HORIZONTALLY. | | | 3. NEC 210.8 GROUND FAULT CIRCUIT-INTERRUPTER | | | PROTECTION. (B) OTHER THAN DWELLING UNITS. ALL OUTLETS | | | IN A KITCHEN SHALL BE GFCI PROTECTED. | | | 4. NEC 406.9(B) RECEPTACLES IN WET LOCATIONS. 15 AND 20 | | | AMPERE, 125 AND 250 VOLT RECEPTACLES INSTALLED IN A WET | | | LOCATION SHALL HAVE AN ENCLOSURE THAT IS WEATHERPROOF | | | WHETHER OR NOT THE ATTACHMENT PLUG CAP IS INSERTED. ALL | | | 15- AND 20-AMPERE, 125- AND 250-VOLT NONLOCKING | | | RECEPTACLES SHALL BE LISTED WEATHER-RESISTANT TYPE | | | ?WR?. | | | 5. FBC-E C402.4.8 RECESSED LIGHTING. RECESSED LIGHTING | | | INSTALLED IN THE BUILDING THERMAL ENVELOPE SHALL BE IC | | | RATED AND BE SEALED TO LIMIT AIR LEAKAGE BETWEEN | | | CONDITIONED & UNCONDITIONED SPACES. | | | 6. FBC-E C405 REVISE YOUR DRAWINGS TO COMPLY WITH THE | | | MANDATORY LIGHTING AND SWITCHING REQUIREMENTS OF THIS | | | CODE. | | | | | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | | RE-SUBMITTAL, YOU ARE REQUIRED TO PROVIDE A RESPONSE | | | LETTER (NARRATIVE) ADDRESSING EACH ITEM ALONG WITH THE | | | STANDARD CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE | | | INSERT CORRECTED PAGES INTO THE SUBMITTAL AND LEAVE THE | | | PREVIOUSLY REVIEWED SHEETS FOR COMPARISON. | | | CLOUDING THE CHANGES WILL BE GREATLY APPRECIATED. | | | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | | CONTACT ME DIRECTLY. | | | | | | THANK YOU, | | | MIKE ALBARRAN | | | ELECTRICAL PLANS EXAMINER | | | PH: 561-805-6746 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2015-09-23 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-09-23 |
Time |
18:50 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-09-23 |
Time |
17:38 |
Sent To |
|
|
| Notes |
| 2015-09-23 18:49:41 | PLEASE NOTE THAT I, MIKE ALBARRAN, ELECTRICAL PLANS | | | EXAMINER HAVE COMPLETED THE REVIEW OF THE ABOVE | | | MENTIONED JOB. BELOW ARE THE COMMENTS WITH REGARDS TO | | | THE REQUIRED CORRECTIONS. THE FOLLOWING ITEMS SHALL BE | | | CORRECTED AND THE PLANS RESUBMITTED FOR ANOTHER REVIEW. | | | PG. E.1 | | | 1. YOU ARE MISSING EMERGENCY LIGHTING IN: THE | | | ELECTRICAL ROOM, THE REST ROOMS MECHANICAL ROOM, | | | GALLERY STAIRS AND ART WAREHOUSE. | | | 2. THERE IS A MISSING EXIT LIGHT IN ROOM 211 TOWARDS | | | THE REAR STAIRS. | | | PG. E.2 | | | 1. YOU SHALL ADHERE TO THE MANDATORY LIGHTING CONTROL | | | REQUIREMENTS OF THE 2014 FBC-ENERGY SECTION 505 | | | | | | IF THE GENERATOR IS TO BE A PART OF THIS PERMIT, SPEC | | | SHEETS ON THE GENERATOR SHALL BE SUBMITTED ACCOMPANIED | | | BY LOAD CALCS FOR THE GENERATOR CONNECTED LOADS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND LEAVE THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | | CONTACT ME DIRECTLY. | | | | | | THANK YOU | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
P |
Date |
2016-01-29 |
|
|
Cont ID |
|
| Sent By |
Mgonzale |
Date |
2016-01-29 |
Time |
|
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
2016-01-29 |
Time |
|
Sent To |
I |
|
| Notes |
| 2016-01-29 19:12:55 | PROVISOS: | | | PASSED WITH PROVISOS: | | | | | | #1 NO ROW WORK WILL BEGIN WITHOUT ENGINEERING | | | DEPARTMENT APPROVAL. | | | | | | #2 CONTRACTOR MUST HAVE SWPPP ACTIVE AT ALL TIMES. | | | | | | MANUEL JULIAN GONZALEZ | | | ENGINEERING PROJECT COORDINATOR | | | PUBLIC WORKS DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1085 | | | FAX: (561) 494-1116 | | | EMAIL: [email protected] | | | | | | | | | IMPORTANT MESSAGE: AS OF DECEMBER 20, 2015 THE CITY OF | | | WEST PALM BEACH | | | CROSS-CONNECTION CONTROL MANUAL HAS BEEN REVISED, | | | MAKING KNOWN THAT "ALL BACKFLOW DEVICES MUST BE LEAD | | | FREE." | | | FOR MORE INFORMATION REFER TO THE LINK BELOW: | | | HTTP://WPB.ORG/DEPARTMENTS/PUBLIC-UTILITIES/FORMS-PUBLI | | | CATIONS/BACKFLOW-CROSS-CONNECTION-CONTROL-MANUAL | | | | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2015-12-02 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
2015-12-02 |
Time |
07:39 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
2015-12-01 |
Time |
14:44 |
Sent To |
|
|
| Notes |
| 2015-12-02 07:39:24 | ENGINEERING DEVELOPMENT APPLICATION E15110026 WAS | | | SUBMITTED ON NOVEMBER 25, 2015. WATER, SEWER, GRADING, | | | AND DRAINAGE TECHNICAL REVIEW WILL BE UNDER THAT | | | APPLICATION. | | | | | | NO CONSTRUCTION ACTIVITIES MAY BEGIN UNTIL LAND | | | STABILIZATION AND EROSION CONTROL BONDS HAVE BEEN | | | RECEIVED BY THE CITY. BONDS ARE TO BE SUBMITTED TO THE | | | CITY'S PUBLIC WORKS DEPARTMENT, ENGINEERING DIVISION. | | | THE BOND(S) WILL BE RELEASED UPON APPROVED INSPECTION | | | OF TIE-BEAMS OR SIMILAR VERTICAL CONSTRUCTION. (CITY | | | CODE SECTION 94-450) | | | | | | KELLY CRANFORD, P.E. | | | CAPITAL IMPROVEMENT PLAN MANAGER | | | PUBLIC WORKS DEPARTMENT | | | CITY OF WEST PALM BEACH | | | [email protected] | | | 561-494-1098 (OFFICE) | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2015-09-28 |
|
|
Cont ID |
|
| Sent By |
Mgonzale |
Date |
2015-09-28 |
Time |
|
Rev Time |
0.50 |
| Received By |
mgonzale |
Date |
2015-09-28 |
Time |
|
Sent To |
I |
|
| Notes |
| 2015-09-28 15:04:59 | A SEPARATE SUBMITTAL TO ENGINEERING DEPARTMENT IS | | | REQUIRED. | | | SEE ENGINEERING DEVELOPMENT PERMIT | | | HTTP://WPB.ORG/ENGINEERING/FORMS-AND-PUBLICATIONS/ | | | | | | MANUEL JULIAN GONZALEZ | | | ENGINEERING PROJECT COORDINATOR | | | PUBLIC WORKS DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1085 | | | FAX: (561) 494-1116 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
P |
Date |
2016-01-28 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2016-01-28 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2016-01-28 |
Time |
14:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2016-01-15 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2016-01-15 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2016-01-15 |
Time |
14:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2015-12-16 |
|
|
Cont ID |
|
| Sent By |
rlindow |
Date |
2015-12-16 |
Time |
|
Rev Time |
0.00 |
| Received By |
rlindow |
Date |
2015-12-16 |
Time |
|
Sent To |
|
|
| Notes |
| 2015-12-16 09:34:52 | SHEETS L1 AND L2 | | | FURTHER DEFINE USE OS SPACE. | | | PLANS PROPOSE WAREHOUSE USE, APPEARS TO BE ASSEMBL USE. | | | | | | FIRE PROTECTION FOR COOKING ON SECOND FLOOR TO BE IN | | | ACCORDANCE WITH NFPA 96. THIS IS TO INCLUDE REQUIRED | | | VENTILATION. | | | LINDOW 12/16/15 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2015-11-05 |
|
|
Cont ID |
|
| Sent By |
rlindow |
Date |
2015-11-05 |
Time |
07:48 |
Rev Time |
0.00 |
| Received By |
rlindow |
Date |
2015-11-05 |
Time |
|
Sent To |
|
|
| Notes |
| 2015-11-05 07:53:23 | 11/5/15, LINDOW | | | | | | PROVIDE ENGINEER OF RECORD STAMP FOR FIRE SPRINKLER | | | DRAWINGS. | | | SHOP DRAWINGS REQURED FOR FIRE SPRINKLER. | | | FIRE SPRINKLER DRAWINGS SHOW WRONG EDITION OF THE CODE, | | | SHOULD BE 2010. | | | FIRE ALARM SYSTEM REQUIRED TO MONITOR FIRE SPRINKLER. | | | PROVIDE PROTECTION TO COMPLY WITH NFPA 96 FOR STOVE IN | | | KITCHEN. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2015-08-31 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2015-08-31 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2015-08-31 |
Time |
16:01 |
Sent To |
|
|
| Notes |
| 2015-08-31 16:11:43 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) SHEETS L1 & L2, THERE IS NO REFERENCE TO THE FLORIDA | | | FIRE PREVENTION CODE, 5TH EDITION; PLEASE ADD NOTE AND | | | ENSURE COMPLAINCE. | | | THE PROPOSED PROJECT SHALL MEET THE REQUIREMENTS OF THE | | | 5TH EDITION OF FLORIDA FIRE PREVENTION CODE INCLUDING | | | THE 2012 EDITION OF NFPA 1 AND NFPA 101 AND ALL OTHER | | | APPLICABLE CODES OR STANDARDS. | | | FIRE SPRINKLER WORK SHALL COMPLY WITH THE REQUIREMENTS | | | OF NFPA 13, 2010 EDITION. | | | FIRE ALARM WORK SHALL COMPLY WITH THE REQUIREMENTS OF | | | NFPA 72, 2010 EDITION. | | | CONSTRUCTION WORK SHALL COMPLY WITH THE REQUIREMENTS OF | | | NFPA 241, 2009 EDITION. | | | FIRE EXTINGUISHERS SHALL COMPLY WITH THE REQUIREMENTS | | | OF NFPA 10, 2010 EDITION. | | | ELECTRIC WORK SHALL COMPLY WITH NFPA 70, 2011 EDITION. | | | | | | | | | 2) SHEET S 1, . PER FLORIDA 69A-60.0081; NOTICE SIGNAGE | | | IS REQUIRED FOR STRUCTURES WITH LIGHT-FRAME TRUSS-TYPE | | | CONSTRUCTION. ANY COMMERCIAL, INDUSTRIAL, OR ANY | | | MULTIUNIT RESIDENTIAL STRUCTURE OF THREE UNITS OR MORE | | | WHICH USES HORIZONTAL OR VERTICAL LIGHT-FRAME | | | TRUSS-TYPE CONSTRUCTION IN ANY PORTION SHALL BE MARKED | | | WITH A MALTESE CROSS SIGN MEASURING 8 INCHES | | | HORIZONTALLY AND 8 INCHES VERTICALLY, OF A BRIGHT RED | | | REFLECTIVE COLOR. THE APPROVED SYMBOL SHALL BE PLACED | | | WITHIN 24 INCHES TO THE LEFT OF THE MAIN ENTRY DOOR. | | | 1. STRUCTURES WITH LIGHT-FRAME TRUSS ROOFS SHALL BE | | | MARKED WITH THE LETTER "R". | | | 2. STRUCTURES WITH LIGHT-FRAME TRUSS FLOOR SYSTEMS | | | SHALL BE MARKED WITH THE LETTER "F". | | | 3. STRUCTURES WITH LIGHT-FRAME TRUSS FLOOR AND ROOF | | | SYSTEMS SHALL BE MARKED WITH THE LETTERS "R/F". | | | | | | 3) SHEET S 6, NO STAIR RAILING DETAIL IS INDICATED. | | | STAIR DETAIL SHALL BE PER NFPA 101, CHAPTER 7. | | | | | | 4) SHEET S 1, THERE IS REFERENCE TO ONLY THE EXTERIOR | | | DOOR SCHEDULE AND NO HARDWARE. PROVIDE AN INTERIOR DOOR | | | SCHEDULE INCLUDING ALL HARDWARE. PANIC HARDWARE SHALL | | | BE INSTALLED ON ALL REQUIRED EXIT DOORS. | | | DOORS SHALL BE ARRANGED TO BE OPENED READILY FROM THE | | | EGRESS SIDE WHENEVER THE BUILDING IS OCCUPIED. LOCKS, | | | IF PROVIDED, SHALL NOT REQUIRE THE USE OF A KEY, TOOL, | | | OR SPECIAL KNOWLEDGE OR EFFORT FOR OPERATION FROM THE | | | EGRESS SIDE. | | | | | | INDICATE IF THE DOORS WILL BE EQUIPPED WITH ANY | | | LOCK/LATCH. IF THE DOORS WILL BE EQUIPPED WITH A | | | LOCK/LATCH, INDICATE HOW THE LOCK/LATCH WILL BE | | | RELEASED FROM THE EGRESS SIDE OF THE DOOR. | | | | | | PER SECTION 7.2.1.5.9, THE LOCK/LATCH RELEASING | | | MECHANISM ON ALL DOORS SHALL OPEN THE DOOR WITH NOT | | | MORE THAN ONE RELEASING OPERATION. THE RELEASING | | | MECHANISM SHALL HAVE AN OBVIOUS METHOD OF OPERATION | | | THAT IS READILY OPERATED UNDER ALL LIGHTING CONDITIONS. | | | THE RELEASING DEVICE SHOULD BE CAPABLE OF BEING | | | OPERATED WITH ONE HAND AND SHOULD NOT REQUIRE TIGHT | | | GRASPING, TIGHT PINCHING OR TWISTING OF THE WRIST TO | | | OPERATE. | | | | | | A THUMB TURN LOCK IS NOT PERMITTED ON THE MAIN ENTRY | | | DOOR(S). IN LIEU OF PANIC HARDWARE, THE MAIN ENTRY IS | | | PERMITTED TO BE EQUIPPED WITH A KEYED LOCK WITH | | | LOCK/UNLOCK INDICATOR WINDOW AND SIGNAGE STATING THE | | | DOOR IS TO REMAIN UNLOCKED DURING BUSINESS HOURS. NO | | | OTHER LOCKING OR LATCHING MECHANISMS ARE PERMITTED. | | | | | | THUMB-TURN LOCK TO BE EQUIPPED WITH AN ?OPEN/LOCKED? | | | INDICATOR WINDOW (SUCH AS ADAMS RITE 4089 OR SIMILAR). | | | | | | FOR ASSEMBLY AND EDUCATIONAL OCCUPANCIES WITH AN | | | OCCUPANT LOAD OF 100 OR MORE PERSONS (50 PERSONS PER | | | THE FLORIDA BUILDING CODE), PANIC HARDWARE SHALL BE | | | PROVIDED ON DOORS TO RELEASE THE LOCK/LATCH. NO OTHER | | | LOCKS OR LATCHES ARE PERMITTED THAT WOULD NOT BE | | | RELEASED BY THE PANIC HARDWARE. AS A SUBSTITUTE FOR | | | PANIC HARDWARE, THE MAIN ENTRANCE IS PERMITTED TO HAVE | | | AN INTERIOR KEYED DOOR LOCK (AND NO LATCH) WITH A | | | READILY VISIBLE SIGN STATING THIS DOOR TO REMAIN | | | UNLOCKED WHEN THE BUILDING IS OCCUPIED. SIGN LETTERS | | | SHALL BE AT LEAST 1 INCH IN HEIGHT. KEYED LOCK TO BE | | | EQUIPPED WITH AN ?OPEN/LOCKED? INDICATOR WINDOW (SUCH | | | AS ADAMS RITE 4089 OR SIMILAR). A THUMB TURN STYLE LOCK | | | IS NOT PERMITTED TO BE SUBSTITUTED FOR A KEYED LOCK. | | | | | | 5) PROVIDE PRELIMINARY FIRE ALARM SYSTEM DRAWINGS. | | | | | | 6) PROVIDE PRELINMIARY FIRE SPRINKLER SYSTEM DRAWINGS. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
4 |
Status |
P |
Date |
2016-02-02 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-02-01 |
Time |
15:21 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-02-01 |
Time |
15:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
F |
Date |
2016-01-16 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-01-16 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-01-16 |
Time |
10:23 |
Sent To |
|
|
| Notes |
| 2016-01-16 10:24:38 | 3RD REVIEW: FBC 2014 | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | 2NDREQUEST ON COMMENTS 1-4 / 3RDREQUEST ON COMMENT 5 | | | | | | 1. SHOW LINE PRESSURE UPSTREAM AND DOWN STREAM OF | | | STEPDOWN REGULATORS. PER WPB AMEND.TO FBC SEC 107.2.1 | | | 2. 25 EHD IS UNDERSIZED ON GENERATOR PER TABLE402.4(15) | | | 3.18 EHD IS UNDERSIZED ON SIX BURNER RANGE PER TABLE | | | 402.(15) | | | 4. SIZE PIPE ON DOWN STREAM SIDE OF STEPDOWN REGULATORS | | | ON ALL APPLIANCES.PER WPB AMEND.TO FBC SEC 107.2.1 | | | 5. 1ST REVIEW REFERENCES COMBUSTION AIR BUT I DID NOT | | | SEE ANY CALCS PLEASE CLARIFY. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2015-12-17 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2015-12-17 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2015-12-17 |
Time |
11:26 |
Sent To |
|
|
| Notes |
| 2015-12-17 11:40:05 | REVIEW: FBC 2014 | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | 1. SHOW LINE PRESSURE UPSTREAM AND DOWN STREAM OF | | | STEPDOWN REGULATORS. PER WPB AMEND.TO FBC SEC 107.2.1 | | | 2. 25 EHD IS UNDERSIZED ON GENERATOR PER TABLE402.4(15) | | | 3.18 EHD IS UNDERSIZED ON SIX BURNER RANGE PER TABLE | | | 402.(15) | | | 4. SIZE PIPE ON DOWN STREAM SIDE OF STEPDOWN REGULATORS | | | ON ALL APPLIANCES.PER WPB AMEND.TO FBC SEC 107.2.1 | | | 5. 1ST REVIEW REFERENCES COMBUSTION AIR BUT I DID NOT | | | SEE ANY CALCS PLEASE CLARIFY. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2015-11-12 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-11-12 |
Time |
11:55 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-11-12 |
Time |
11:21 |
Sent To |
|
|
| Notes |
| 2015-11-12 09:34:51 | 1) SHT. P-3 - SUBMIT 2 COPIES OF THE MANUFACTURER'S | | | SPECIFICATIONS FOR ALL GAS APPLIANCES/EQUIPMENT. | | | APPLIANCES/EQUIPMENT SHALL BE LISTED AND LABELED PER | | | 2014 FBC-GAS CODE, SEC.301.3. | | | 2) THE GAS GENERATOR SHALL COMPLY WITH NFPA 37 AND | | | COMPLY WITH UL 2200. 2010 FGC SEC.616.1. SUBMIT | | | DOCUMENTATION THAT SHOWS COMPLIANCE. | | | 3) SHT. P-3 - THE GAS RISER INDICATES GALVANIZED PIPE | | | UNDERGROUND. GALVANIZED PIPING IS NOT PERMITTED | | | UNDERGROUND UNLESS FACTORY APPLIED COATINGS OR | | | WRAPPINGS ARE INSTALLED ON THE PIPING. ZINC COATINGS | | | ARE NOT DEEMED ADEQUATE PROTECTION FOR GAS PIPING | | | UNDERGROUND. 2014 FBC-FUEL GAS SEC.404.11, 404.11.1, | | | 404.11.2. | | | 4) INDICATE ON THE PLANS THE NUMBER OF THE SPECIFIC GAS | | | TABLE(S) THAT IS /ARE BEING USED IN THE SIZING OF THE | | | GAS SYSTEM. 2014 FGC SEC.402.3, 402.4. | | | 5) INDICATE ON THE PLAN THE DISTANCE FROM THE METER TO | | | THE MOST REMOTE OUTLET AND FROM EACH STEP DOWN | | | REGULATOR TO THE MOST REMOTE OUTLET ON THAT PIPE | | | SECTION. 2014 FGC SEC.402.4.1. | | | 6) SHOW THE BTU LOAD OF THE GENERATOR ON THE GAS | | | DRAWING. WPB AMEND. TO FBC SEC. 107.3.5.1.3. | | | 7) SHOW THE LOCATION OF ALL STEP DOWN REGULATORS ON THE | | | PLANS. WPB AMEND. TO FBC SEC. 107.3.5.1.3. | | | 8) SHOW THE PSI OF THE GAS DOWNSTREAM FROM THE METER | | | AND FROM THE STEP DOWN REGULATORS. | | | 9) THE GAS RISER SHOWS AN EHD OF 13 ON SOME SECTIONS OF | | | THE CSST ON THE GAS RISER. THIS IS EQUIVALENT TO 3/8" | | | TUBING. IS THIS CORRECT? CLARIFY. | | | 10) PLEASE EXPLAIN HOW YOU ARRIVED AT THE AMOUNT OF | | | REQUIRED COMBUSTION AIR. I AM NOT VERY FAMILIAR WITH | | | THE EQUATION FROM SEC.304.9 OF THE FUEL GAS CODE. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2016-02-04 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-02-04 |
Time |
07:30 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-01-27 |
Time |
13:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2016-01-27 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2016-01-27 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2016-01-12 |
Time |
09:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2016-01-04 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2016-01-04 |
Time |
16:10 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-12-09 |
Time |
10:42 |
Sent To |
|
|
| Notes |
| 2016-01-04 16:11:40 | 1/4/16 FAILED ELECTRICAL REVIEW AS WELL AS OTHER | | | TRADES. SPOKE W/STEPHEN SINCLAIR WHO WILL SUBMIT | | | CORRECTED SHEETS. SENT TO LARGE DENIED BIN "C". MA | | 2015-12-10 10:42:42 | C35 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-12-03 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-12-03 |
Time |
17:23 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-10-27 |
Time |
14:33 |
Sent To |
|
|
| Notes |
| 2015-12-03 17:25:25 | 12/3/15 FAILED ELECTRICAL REVIEW AS WELL AS ALL OTHER | | | TRADES. RUNNER NOTIFIED VIA EMAIL. SENT TO LARGE DENIED | | | BIN "C". MA | | 2015-10-27 14:34:19 | C26 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-09-29 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2015-09-29 |
Time |
16:07 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2015-08-28 |
Time |
13:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2016-02-04 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-02-04 |
Time |
07:30 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-02-04 |
Time |
06:48 |
Sent To |
E |
|
| Notes |
| 2016-02-04 07:34:22 | MECHANICAL PROVISOS | | | PERMIT #15011109 | | | 2/4/16 | | | | | | 1) MANUFACTURER'S SPECIFICATIONS FOR ALL AC EQUIPMENT, | | | COOKING APPLIANCES, EXHAUST HOODS, FIRE DAMPERS, O/A | | | DAMPERS, DUCT SMOKE DETECTORS, AND C02 DETECTORS SHALL | | | BE ON-SITE AT TIME OF INSPECTION. | | | 2) SEPARATE PERMITS REQUIRED FOR TYPE-1 GREASE HOOD AND | | | FIRE SUPPRESSION. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
F |
Date |
2016-01-20 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-01-20 |
Time |
15:36 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-01-20 |
Time |
15:36 |
Sent To |
|
|
| Notes |
| 2016-01-20 15:49:53 | 5TH REVIEW: FBC 2014 MECHANICAL | | | PERMIT #15081109 | | | 01/20/16 | | | | | | 1) THE PLANS ARE INDICATING COMBUSTIBLE WOOD DOORS FOR | | | ALL OF THE AC CLOSETS AND MECHANICAL ROOMS. PLEASE | | | REFER TO SECTION C403.2.7.2 FBC-14 ENERGY CONSERVATION, | | | AND SECTION 606.2 FBC-14 MECHANICAL AND PROVIDE | | | NON-COMBUSTIBLE DOORS. | | | 2) THE C02 SENSORS ARE NOT UL LISTED AND LABELED. | | | PROVIDE A UL LISTED DEVICE. | | | 3) THE RETURN DUCT FROM THE EMPLOYEE LOUNGE INTO THE | | | MECHANICAL ROOM IS UNDERSIZED PER SECTION 601.5 FBC-14 | | | MECHANICAL. DUCT MUST HAVE A CROSS-SECTION AREA OF 225 | | | SQ. INCHES. | | | 4) THE ENERGY CALCULATION FORM 506-2014 MUST BE REVISED | | | TO SHOW THE CHANGE TO THE SMALLER CAPACITY HEAT PUMPS. | | | 5) PLEASE CLARIFY WHY THE AIR HANDLER CAPACITIES HAVE | | | NOT BEEN REDUCED TO MATCH THE REDUCED HEAT PUMP | | | CAPACITIES. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2015-12-18 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-12-18 |
Time |
07:06 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-12-18 |
Time |
07:06 |
Sent To |
|
|
| Notes |
| 2015-12-18 07:24:19 | 3RD REVIEW 2014 MECHANICAL | | | PERMIT #15081109 | | | 12/18/15 | | | | | | 1) AS PREVIOUSLY NOTED IN THE 2ND REVIEW, THE AC | | | SYSTEMS CANNOT BE SIZED LARGER THAN THE CALCULATED | | | LOADS. THE TOTAL LOAD CALCULATED BY KO DESIGN FOR | | | COOLING IS 31.56 TONS, HOWEVER THE TOTAL LOAD SHOWN IN | | | THE AC SCHEDULE ON SHEET M1 IS 51.66. PLEASE SEE | | | SECTION C403.2.2 FBC-14 ENERGY CONSERVATION. | | | 2) THE LOCATIONS OF THE DUCT SMOKE DETECTORS SHOWN ON | | | THE REVISED PLANS ARE NOT IN COMPLIANCE WITH 606.2.1 | | | FBC-14 MECHANICAL: THE DEVICES SHALL BE UPSTREAM OF THE | | | O/A DUCT CONNECTIONS INTO THE RETURN AIR PLENUMS. | | | 3) THE FLEX DUCTS CANNOT BE USED FOR OUTSIDE AIR DUCTS | | | BECAUSE THEY ARE NOT MOISTURE RESISTANT- PROVIDE METAL | | | DUCTING. | | | 4) THE SUBMITTED MANUFACTURER'S SPECIFICATIONS FOR THE | | | COOKTOP DO NOT INDICATE THE PRODUCT IS LISTED AND | | | LABELED IN ACCORDANCE WITH UL 197 FOR COMMERCIAL USE. - | | | SEE SECTION 917.1 FBC-14 MECHANICAL AND PROVIDE | | | DOCUMENTION VERIFYING COMPLIANCE. | | | 5) PLEASE SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE | | | CO2 SENSORS REVIEWED AND APPROVED BY THE ENGINEER OF | | | RECORD. | | | 6) PLACE NOTE ON THE PLAN THE KITCHEN GAS RANGE, | | | ELECTRIC COOKTOP AND HOOD WILL BE DONE UNDER SEPARATE | | | PERMIT. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2015-12-17 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-12-17 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-12-17 |
Time |
12:43 |
Sent To |
|
|
| Notes |
| 2015-12-17 16:48:30 | 2ND REVIEW 2014 MECHANICAL | | | PERMIT #15081109 | | | 12/17/15 | | | | | | 1) | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2015-11-12 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-11-12 |
Time |
17:26 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-11-12 |
Time |
17:25 |
Sent To |
|
|
| Notes |
| 2015-11-12 17:39:27 | 2ND REVIEW: FBC 2014 MECHANICAL | | | PERMIT #15081109 | | | 11/12/15 | | | | | | 1) REFER TO SECTION C403.2.2 FBC-14 ENERGY | | | CONSERVATION: THE OUTPUT CAPACITIES OF THE AC SYSTEMS | | | IN THE EQUIPMENT SCHEDULE ON SHEET M1 ARE EXCEEDING THE | | | CALCULATED LOADS SHOWN IN THE CALCULATION SUBMITTAL | | | FROM K.O. ENERGY DESIGN. A) SYSTEM 1 CALCULATIONS | | | INDICATE 12.82 TONS COOLING , SYSTEM 1 SCHEDULE | | | INDICATES 21.5 TONS. B) SYSTEM 2 CALCS- 7.97 TONS, | | | SCHEDULE- 12.5 TONS. C) SYSTEM 3 CALCS- 10.78, | | | SCHEDULE- 19.5 TONS. TOTAL COOLING CALCULATION- 31.56 | | | TONS, TOTAL COOLING SHOWN ON SCHEDULE- 53.5 TONS. | | | PLEASE NOTE THAT THE CALCS SHOW 0 BTUH FOR HEATING | | | REQUIRED, HOWEVER HEATING IS REQUIRED PER SECTION 309.1 | | | FBC-14 MECHANICAL. | | | 2) SHEET M1 & M2: REFER TO TABLE 404.4 FBC-14 | | | MECHANICAL- THE OUTSIDE AIR CALCULATIONS MUST BE | | | REVISED TO INCLUDE THE GALLERY AREAS AT 7.5 CFM PER | | | PERSON AND THE THEATER AREA AT 10 CFM PER PERSON. | | | FURTHER REVISION MAY BE REQUIRED PENDING OCCUPANCY | | | CLASSIFICATION CHANGES. | | | 3) M1: THE FIRST FLOOR STUDIO BATHS INDICATES A SHOWER | | | WHICH REQUIRES 50 CFM EXHAUST IN ADDITION TO THE 50 CFM | | | FOR THE TOILET- TABLE 403.3. | | | 4) M1: INDICATE HOW THE RETURN AIR SYSTEM IS | | | FUNCTIONING FOR AHU #7. | | | 5) M1: PROVIDE ADDITIONAL DETAILS TO CLARIFY HOW | | | OUTSIDE AIR IS BEING SUPPLIED FOR AHU'S 3, 4, 5, 6, 7, | | | 14, AND 15. PROVIDE THE SIZES OF THE W.P. WALL JACKS, | | | SHOW THE REQUIRED MOTORIZED DAMPERS FOR THE INTAKES, | | | AND INDICATE THE AMOUNT OF O/A BEING SUPPLIED. REFER TO | | | SECTION 401.4 AND 401.5 FOR AIR INTAKE COMPLIANCES- | | | PLEASE NOTE THAT THE OPENINGS SHALL BE LOCATED A | | | MINIMUM OF 10' | | | HORIZONTALLY FROM ALLEYS UNLESS THEY ARE 25' ABOVE | | | GRADE. | | | 6) M1: REFER TO SECTION 3006.2 FBC-14 BUILDING AND | | | CLARIFY IF THE ELEVATOR ROOM CONTAINS SOLID STATE | | | EQUIPMENT WHICH REQUIRES AN INDEPENDENT AC SYSTEM. SEE | | | ALSO SECTION 3006.4 FOR FIRE BARRIER ENCLOSURE- NOTE: | | | FIRE DAMPERS MAY BE REQUIRED FOR THE DUCTS PENETRATING | | | THE ELEVATOR ROOM CEILING. | | | 7) M1: PROVIDE A DETAIL FOR FIRE DAMPERS IN THE | | | STAIRWELL CEILINGS- SEE SECTION 717.6.2: A SHAFT | | | ENCLOSURES OR CEILING RADIATION DAMPERS ARE REQUIRED. | | | REFER TO SECTION 1022.5 & 1022.6 FBC-14 BUILDING: | | | INDEPENDENT VENTILATION SYSTEMS FOR INTERIOR EXIT | | | STAIRWAYS ARE REQUIRED- THE SUPPLY DUCTS PENETRATING | | | INTO THE STAIRWELLS ARE NOT PERMITTED. | | | 8) M1 & M2: SHOW THE LOCATIONS OF THE REQUIRED DUCT | | | SMOKE DETECTORS IN THE AHU RETURN AIR SYSTEMS- SECTION | | | 606.2.1. | | | 9) M2: INDICATE HOW THE RETURN AIR SYSTEM IS | | | FUNCTIONING FOR AHU-13. NO ACCESS FOR RETURN AIR INTO | | | THE MECHANICAL ROOM IS SHOWN ON THE PLAN. | | | 10) THE LOCATION OF THE HOOD EXHAUST TERNINATION IS | | | REQUIRED TO BE 10' ABOVE GRADE AND 10' FROM THE | | | PROPERTY LINE- SECTION 501.3.1 FBC-14 MECHANICAL: THE | | | PLAN DOES NOT CLEARLY INDICATE COMPLIANCE. SUBMIT | | | MANUFACTURER'S SPECS FOR THE GAS GRILL IN THE KITCHEN. | | | PLEASE NOTE A GREASE HOOD AND FIRE SUPPRESSION MAY BE | | | REQUIRED. | | | 11) AS PREVIOUSLY REQUESTED IN THE 1ST REVIEW PROVIDE | | | AN AIR BALANCE CALCULATION ON THE PLAN. | | | 12) AS PREVIOUSLY NOTED IN THE 1ST REVIEW, DEMAND | | | CONTROLLED VENTILATION IS REQUIRED FOR THE PROPOSED | | | OCCUPANCY PER SECTION C403.2/.5.1 FBC-14 ENERGY | | | CONSERVATION- SEE SECTION 202 DEFINITIONS AND PROVIDE A | | | SYSTEM CAPABILITY ON THE PLANS. NOTE: TYPICALLY THIS IS | | | ACCOMPLISHED THROUGH THE USE OF SENSORS AND PROGRAMMING | | | OF THE SYSTEMS | | | 13) DEFERRED SUBMITTALS: FOR THE PURPOSES OF THIS | | | SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE | | | PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE | | | TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO | | | THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. | | | DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR | | | APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED | | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST | | | THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS | | | FOR REVIEW BY THE BUILDING OFFICIAL. SUBMITTALS SHALL | | | INCLUDE THE FIRE DAMPERS, DUCT SMOKE DETECTORS, AIR | | | INTAKE AND EXHAUST LOUVERS, WALL AND ROOF JACKS, DCV | | | SENSORS, AND AC SYSTEMS. | | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | | THE DESIGN OF THE BUILDING. | | | A) PRODUCT APPROVALS. THOSE PRODUCTS WHICH ARE | | | REGULATED BY THE DCA RULE 9N-03 SHALL BE REVIEWED AND | | | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO | | | SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2015-09-10 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-09-10 |
Time |
08:45 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-09-10 |
Time |
08:41 |
Sent To |
|
|
| Notes |
| 2015-09-10 09:13:18 | 1ST REVIEW: FBC 2014 MECHANICAL | | | PERMIT #15081109 | | | 9/10/15 | | | | | | 1) PROVIDE AC COOLING AND HEATING LOAD CALCULATIONS- | | | REFER TO SECTION C403.2.1 FBC-14 ENERGY CONSERVATION-- | | | CALCULATION OF HEATING AND COOLING LOADS. | | | DESIGN LOADS SHALL BE DETERMINED IN ACCORDANCE WITH THE | | | PROCEDURES DESCRIBED IN THE ASHRAE/ACCA STANDARD 183 OR | | | ACCA MANUAL N AND SHALL BE ATTACHED TO THE CODE | | | COMPLIANCE FORM SUBMITTED TO THE BUILDING DEPARTMENT | | | WHEN THE BUILDING IS PERMITTED OR, IN THE EVENT THE | | | MECHANICAL PERMIT IS OBTAINED AT A LATER TIME, THE | | | SIZING CALCULATION SHALL BE SUBMITTED WITH THE | | | APPLICATION FOR THE MECHANICAL PERMIT. HEATING AND | | | COOLING LOADS SHALL BE ADJUSTED TO ACCOUNT FOR LOAD | | | REDUCTIONS THAT ARE ACHIEVED WHEN ENERGY RECOVERY | | | SYSTEMS ARE UTILIZED IN THE HVAC SYSTEM IN ACCORDANCE | | | WITH THE ASHRAEHVAC SYSTEMS AND EQUIPMENT HANDBOOK. | | | ALTERNATIVELY, DESIGN LOADS SHALL BE DETERMINED BY AN | | | APPROVED EQUIVALENT COMPUTATION PROCEDURE, USING THE | | | DESIGN PARAMETERS SPECIFIED IN CHAPTER 3. | | | 2) PROVIDE ENERGY CALCULATIONS PER SECTION C401.2 | | | FBC-14 ENERGY CONSERVATION: C401.2 APPLICATION. | | | COMMERCIAL BUILDINGS SHALL COMPLY WITH ONE OF THE | | | FOLLOWING: | | | 1. THE REQUIREMENTS OF ANSI/ASHRAE/IESNA 90.1. | | | 2. THE REQUIREMENTS OF SECTIONS C402, C403, C404 AND | | | C405. IN ADDITION, COMMERCIAL BUILDINGS SHALL COMPLY | | | WITH EITHER SECTION C406.2, C406.3 OR C406.4. | | | 3. THE REQUIREMENTS OF SECTION C407, C402.4, C403.2, | | | C404, C405.2, C405.3, C405.4, C405.6 AND C405.7. THE | | | BUILDING ENERGY COST SHALL BE EQUAL TO OR LESS THAN 85 | | | PERCENT OF THE STANDARD REFERENCE DESIGN BUILDING. | | | 2A) REFER TO SECTION C101.5.1.1 ALTERATIONS, | | | RENOVATIONS AND BUILDING SYSTEMS. ALTERATIONS, | | | RENOVATIONS AND BUILDING SYSTEMS MAY UTILIZE FORM C402. | | | FORM C402 CAN BE FOUND IN APPENDIX C. | | | 3) REFER TO SECTION 809.1 FBC-14 EXISTING BUILDING CODE | | | AND PROVIDE VENTILATION CALCULATIONS FOR ALL ROOMS, | | | SPACES, AND AREAS SHOWN ON THE PLANS- SEE TABLE 403.3 | | | FBC-14 MECHANICAL AND PROVIDE A SCHEDULE ON THE PLAN | | | INDICATING THE TOTAL CFM'S OF O/A CFM'S OR EXHAUST | | | REQUIRED, AND THE AMOUNTS PROVIDED. PLEASE INCLUDE AN | | | AIR BALANCE CALCULATION. | | | 4) SHEETS M1 & M2: THE PLANS ARE OF INSUFFICIENT | | | CLARITY FOR REVIEW AND FOR COMPUTER SCANNING AND | | | FILING. THE PRINT ON THE AC EQUIPMENT SCHEDULES, AND | | | ALL THE PRINTED NOTES, DETAILS, AND TAGS SHOWN IN THE | | | HVAC PLANS ARE EITHER TOO SMALL OR TOO FAINT TO READ- | | | REFER TO SECTION 107.2.1 WPB AMENDMENTS TO THE FBC-14 | | | BUILDING CODE AND ENLARGE AND EMBOLDEN THE PRINT TO | | | EXPEDITE THE REVIEW OF THIS PROJECT. | | | 5) M1 & M2: THE AIR HANDLERS ARE SHOWN IN PLENUM RATED | | | CLOSETS WITH DOUBLE DOORS, HOWEVER THERE ARE NO | | | ARCHITECTURAL FINISH DETAILS OR A DOOR SCHEDULE ON THE | | | PLANS TO VERIFY THE MATERIALS USED ARE PLENUM-RATED: | | | REFER TO SECTION 602 FBC-14 MECHANICAL. | | | 6) M1 & M2: REFER TO SECTION 603.1.1 FBC-14 MECHANICAL | | | AND PROVIDE DETAILS AND DIMENSIONS ON THE PLANS TO | | | VERIFY COMPLIANCE- 603.1.1 SPACE PROVIDED. | | | SUFFICIENT SPACE SHALL BE PROVIDED ADJACENT TO ALL | | | MECHANICAL COMPONENTS LOCATED IN OR FORMING A PART OF | | | THE AIR DISTRIBUTION SYSTEM TO ASSURE ADEQUATE ACCESS | | | FOR (1) CONSTRUCTION AND SEALING IN ACCORDANCE WITH THE | | | REQUIREMENTS OF SECTION 603.1 OF THIS CODE; (2) | | | INSPECTION; AND (3) CLEANING AND MAINTENANCE. A MINIMUM | | | OF 4 INCHES (102 MM) IS CONSIDERED SUFFICIENT SPACE | | | AROUND AIR HANDLING UNITS. | | | 7) PROVIDE AN AIR DISTRIBUTION SCHEDULE LISTING THE | | | MAKES, MODELS, AND SIZES OF ALL AC SUPPLY DIFFUSERS AND | | | RETURN AIR GRILLS. | | | 8) INDICATE THE TYPE(S) OF SUPPLY AND RETURN DUCTWORK | | | TO BE USED, AND PROVIDE DUCT CONNECTION, HANGING AND | | | SUPPORT DETAILS- REFER TO TABLE C403.2.7.2 FBC-14 | | | ENERGY CONSERVATION. | | | 9) BATH AND TOILET ROOM EXHAUST: ENLARGE THE DETAILS TO | | | CLEARLY SHOW THE EXHAUST FANS, THE TYPES AND SIZES OF | | | EXHAUST DUCTS, THE DUCT RUNS, AND TERMINATION | | | LOCATIONS. PROVIDE EXHAUST FAN EQUIPMENT SCHEDULES ON | | | THE PLANS LISTING THE MAKES AND MODELS, AND EXHAUST CFM | | | CAPACITIES. | | | 10) THE PLAN IS INDICATING A KITCHEN AND A KITCHEN | | | EXHAUST HOOD- PLEASE PLACE A NOTE INDICATING THE | | | KITCHEN HOOD, EXHAUST, AND FIRE SUPPRESSION SYSTEM WILL | | | BE DONE UNDER SEPARATE PERMITS, HOWEVER PLEASE INCLUDE | | | THE HOOD MAKEUP SUPPLY AND EXHAUST CFM'S IN THE AIR | | | BALANCE CALCULATIONS. | | | 11) PROVIDE A ROOF PLAN INDICATING THE LOCATIONS OF AND | | | CLEARANCE DISTANCES FOR THE KITCHEN EXHAUST FAN, AND | | | THE MAKEUP AIR INTAKE FAN. REFER TO SECTION 304.11 | | | GUARDS AND PROVIDE DETAILS IF APPLICABLE. | | | 12) PROVIDE PRIMARY AND SECONDARY CONDENSATE DISPOSAL | | | PLANS FOR THE AIR HANDLERS- SEE SECTION 307. | | | 13) PROVIDE AHRI CERTIFICATES FOR THE NEW HP SYSTEMS. | | | 14) REFER TO SECTION 301.15 FBC-14 MECHANICAL AND | | | PROVIDE TIE-DOWN ENGINEERING FOR THE EXTERIOR | | | CONDENSERS. PLEASE INCLUDE THE WIND LOAD DESIGN | | | CRITERIA AND WIND PRESSURES ON THE PLAN IN ACCORDANCE | | | WITH SECTION 1609 FBC-14 BUILDING- 301.15 WIND | | | RESISTANCE. | | | MECHANICAL EQUIPMENT, APPLIANCES AND SUPPORTS THAT ARE | | | EXPOSED TO WIND SHALL BE DESIGNED AND INSTALLED TO | | | RESIST THE WIND PRESSURES DETERMINED IN ACCORDANCE WITH | | | THE FLORIDA BUILDING CODE. | | | 15) REFER TO SECTION C403.2.4.4 FBC-14 ENERGY | | | CONSERVATION AND SHOW COMPLIANCE- SHUTOFF DAMPER | | | CONTROLS. | | | 16) PROVIDE A DETAIL FOR INSTALLATION OF THE FIRE | | | DAMPER FOR THE FLEX DUCT PENETRATING THE FLOOR/CEILING | | | ASSEMBLY AT THE STAIRWELL/LIBRARY. | | | BOTH OUTDOOR AIR SUPPLY AND EXHAUST DUCTS SHALL BE | | | EQUIPPED WITH MOTORIZED DAMPERS THAT WILL AUTOMATICALLY | | | SHUT WHEN THE SYSTEMS OR SPACES SERVED ARE NOT IN USE. | | | EXCEPTIONS: | | | 1. GRAVITY DAMPERS SHALL BE PERMITTED IN BUILDINGS LESS | | | THAN THREE STORIES IN HEIGHT. | | | 2. GRAVITY DAMPERS SHALL BE PERMITTED FOR BUILDINGS OF | | | ANY HEIGHT LOCATED IN CLIMATE ZONES 1, 2 AND 3. GRAVITY | | | DAMPERS SHALL BE PERMITTED FOR OUTSIDE AIR INTAKE OR | | | EXHAUST AIRFLOWS OF 300 CFM (0.14 M3/S) OR LESS. | | | 17) REFER TO SECTION C403.2.5.1 AND SHOW COMPLIANCE- | | | C403.2.5.1 DEMAND CONTROLLED VENTILATION. | | | DEMAND CONTROL VENTILATION (DCV) SHALL BE PROVIDED FOR | | | SPACES LARGER THAN 500 SQUARE FEET (50 M2) AND WITH AN | | | AVERAGE OCCUPANT LOAD OF 25 PEOPLE PER 1000 SQUARE FEET | | | (93 M2) OF FLOOR AREA (AS ESTABLISHED IN TABLE 403.3 OF | | | THEFLORIDA BUILDING CODE, MECHANICAL) AND SERVED BY | | | SYSTEMS WITH ONE OR MORE OF THE FOLLOWING: | | | 1. AN AIR-SIDE ECONOMIZER; | | | 2. AUTOMATIC MODULATING CONTROL OF THE OUTDOOR AIR | | | DAMPER; OR | | | 3. A DESIGN OUTDOOR AIRFLOW GREATER THAN 3,000 CFM | | | (1400 L/S). | | | EXCEPTION: DEMAND CONTROL VENTILATION IS NOT REQUIRED | | | FOR SYSTEMS AND SPACES AS FOLLOWS: | | | 1. SYSTEMS WITH ENERGY RECOVERY COMPLYING WITH SECTION | | | C403.2.6. | | | 2. MULTIPLE-ZONE SYSTEMS WITHOUT DIRECT DIGITAL CONTROL | | | OF INDIVIDUAL ZONES COMMUNICATING WITH A CENTRAL | | | CONTROL PANEL. | | | 3. SYSTEM WITH A DESIGN OUTDOOR AIRFLOW LESS THAN 1,200 | | | CFM (600 L/S). | | | 4. SPACES WHERE THE SUPPLY AIRFLOW RATE MINUS ANY | | | MAKEUP OR OUTGOING TRANSFER AIR REQUIREMENT IS LESS | | | THAN 1,200 CFM (600 L/S). | | | 5. VENTILATION PROVIDED FOR PROCESS LOADS ONLY. | | | 18) PROVIDE TWO COPIES OF A FL. PRODUCT APPROVAL OR | | | MIAMI-DADE NOA FOR THE OUTSIDE AIR INTAKE LOUVERS. | | | 19) PLEASE NOTE THAT FURTHER COMMENTS MAY FOLLOW | | | RE-SUBMITTAL OF RESPONSES AND PLAN REVISIONS FOR ALL | | | BUILDING DEPARTMENT REVIEW COMMENTS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2016-02-03 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-02-03 |
Time |
12:19 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-02-03 |
Time |
12:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2016-01-16 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-01-16 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-01-16 |
Time |
10:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2015-12-17 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2015-12-17 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2015-12-17 |
Time |
10:20 |
Sent To |
|
|
| Notes |
| 2015-12-17 10:55:43 | 3RD REVIEW: FBC 2014 | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | 1.IN BATHROOMS 104-122-225 TOILETS MUST COMPLY WITH FBC | | | ACC. SEC 604 | | | (A)-604.2 LOCATION. | | | THE WATER CLOSET SHALL BE POSITIONED WITH A WALL OR | | | PARTITION TO THE REAR AND TO ONE SIDE. THE CENTERLINE | | | OF THE WATER CLOSET SHALL BE 16 INCHES (405 MM) MINIMUM | | | TO 18 INCHES (455 MM) MAXIMUM FROM THE SIDE WALL OR | | | PARTITION | | | (B) 604.3.1 SIZE. | | | CLEARANCE AROUND A WATER CLOSET SHALL BE 60 INCHES | | | (1525 MM) MINIMUM MEASURED PERPENDICULAR FROM THE SIDE | | | WALL AND 56 INCHES (1420 MM) MINIMUM MEASURED | | | PERPENDICULAR FROM THE REAR WALL. | | | (C)604.3.2 OVERLAP. | | | THE REQUIRED CLEARANCE AROUND THE WATER CLOSET SHALL BE | | | PERMITTED TO OVERLAP THE WATER CLOSET, ASSOCIATED GRAB | | | BARS, DISPENSERS, SANITARY NAPKIN DISPOSAL UNITS, COAT | | | HOOKS, SHELVES, ACCESSIBLE ROUTES, CLEAR FLOOR SPACE | | | AND CLEARANCES REQUIRED AT OTHER FIXTURES, AND THE | | | TURNING SPACE. NO OTHER FIXTURES OR OBSTRUCTIONS SHALL | | | BE LOCATED WITHIN THE REQUIRED WATER CLOSET CLEARANCE. | | | (D)LAVATORY ARE NOT ALLOWED TO BE IN THE CLEARANCE | | | SPACE FOR THE TOILET IN COMMERCIAL BUILDINGS. | | | | | | 2. SHOW COMPLIANCE FBC ACC. SEC 604.7 DISPENSERS. | | | TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND | | | SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 INCHES (230 | | | MM) MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO | | | THE CENTERLINE OF THE DISPENSER. THE OUTLET OF THE | | | DISPENSER SHALL BE 15 INCHES (380 MM) MINIMUM AND 48 | | | INCHES (1220 MM) MAXIMUM ABOVE THE FINISH FLOOR AND | | | SHALL NOT BE LOCATED BEHIND GRAB BARS. DISPENSERS SHALL | | | NOT BE OF A TYPE THAT CONTROLS DELIVERY OR THAT DOES | | | NOT ALLOW CONTINUOUS PAPER FLOW. | | | 3. SHOW COMPLIANCE FBC ACC. SEC 603.3 MIRRORS. | | | MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL | | | BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING | | | SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FINISH | | | FLOOR OR GROUND. MIRRORS NOT LOCATED ABOVE LAVATORIES | | | OR COUNTERTOPS SHALL BE INSTALLED WITH THE BOTTOM EDGE | | | OF THE REFLECTING SURFACE 35 INCHES (890 MM) MAXIMUM | | | ABOVE THE FINISH FLOOR OR GROUND. | | | 4. SHOW COMPLIANCE SHOWER SEATS FBC ACC. SEC 610.3.1 | | | RECTANGULAR SEATS. | | | THE REAR EDGE OF A RECTANGULAR SEAT SHALL BE 2 1/2 | | | INCHES (64 MM) MAXIMUM AND THE FRONT EDGE 15 INCHES | | | (380 MM) MINIMUM AND 16 INCHES (405 MM) MAXIMUM FROM | | | THE SEAT WALL. THE SIDE EDGE OF THE SEAT SHALL BE 11/2 | | | INCHES (38 MM) MAXIMUM FROM THE ADJACENT WALL. | | | 610.3.2 L-SHAPED SEATS. | | | THE REAR EDGE OF AN L-SHAPED SEAT SHALL BE 2 1/2 INCHES | | | (64 MM) MAXIMUM AND THE FRONT EDGE 15 INCHES (380 MM) | | | MINIMUM AND 16 INCHES (405 MM) MAXIMUM FROM THE SEAT | | | WALL. THE REAR EDGE OF THE ?L? PORTION OF THE SEAT | | | SHALL BE 11/2 INCHES (38 MM) MAXIMUM FROM THE WALL AND | | | THE FRONT EDGE SHALL BE 14 INCHES (355 MM) MINIMUM AND | | | 15 INCHES (380 MM) MAXIMUM FROM THE WALL. THE END OF | | | THE ?L? SHALL BE 22 INCHES (560 MM) MINIMUM AND 23 | | | INCHES MAXIMUM (585 MM) FROM THE MAIN SEAT WALL. | | | 5. SHOW COMPLIANCE FBC ACC. SEC 602 DRINKING FOUNTAINS | | | | | | 602.1 GENERAL. | | | DRINKING FOUNTAINS SHALL COMPLY WITH 307 AND 602. | | | | | | 602.2 CLEAR FLOOR SPACE. | | | UNITS SHALL HAVE A CLEAR FLOOR OR GROUND SPACE | | | COMPLYING WITH 305 POSITIONED FOR A FORWARD APPROACH | | | AND CENTERED ON THE UNIT. KNEE AND TOE CLEARANCE | | | COMPLYING WITH 306 SHALL BE PROVIDED. | | | | | | 307.2 PROTRUSION LIMITS. | | | OBJECTS WITH LEADING EDGES MORE THAN 27 INCHES (685 MM) | | | AND NOT MORE THAN 80 INCHES (2030 MM) ABOVE THE FINISH | | | FLOOR OR GROUND SHALL PROTRUDE 4 INCHES (100 MM) | | | MAXIMUM HORIZONTALLY INTO THE CIRCULATION PATH. | | | 306.3.1 GENERAL. | | | SPACE UNDER AN ELEMENT BETWEEN 9 INCHES (230 MM) AND 27 | | | INCHES (685 MM) ABOVE THE FINISH FLOOR OR GROUND SHALL | | | BE CONSIDERED KNEE CLEARANCE AND SHALL COMPLY WITH | | | 306.3. | | | | | | 306.3.2 MAXIMUM DEPTH. | | | KNEE CLEARANCE SHALL EXTEND 25 INCHES (635 MM) MAXIMUM | | | UNDER AN ELEMENT AT 9 INCHES (230 MM) ABOVE THE FINISH | | | FLOOR OR GROUND. | | | | | | 306.3.3 MINIMUM REQUIRED DEPTH. | | | WHERE KNEE CLEARANCE IS REQUIRED UNDER AN ELEMENT AS | | | PART OF A CLEAR FLOOR SPACE, THE KNEE CLEARANCE SHALL | | | BE 11 INCHES (280 MM) DEEP MINIMUM AT 9 INCHES (230 MM) | | | ABOVE THE FINISH FLOOR OR GROUND, AND 8 INCHES (205 MM) | | | DEEP MINIMUM AT 27 INCHES (685 MM) ABOVE THE FINISH | | | FLOOR OR GROUND. | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2015-11-12 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-11-12 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-11-07 |
Time |
07:33 |
Sent To |
|
|
| Notes |
| 2015-11-06 11:24:17 | 1) SHT. FP-1 - THE BREAK ROOM SINK SHALL COMPLY WITH | | | 2014 FBC-ACCESSIBILITY SECS. 212, 212.3, 804. SHOW | | | COMPLIANCE ON THE PLANS. THERE ARE NO HEIGHT | | | MEASUREMENTS SHOWN ON THE ELEVATION DETAILS SO | | | COMPLIANCE WITH THE FL. ACCESSIBILITY CODE COULD NOT BE | | | CONFIRMED. ALSO, SHOW THE CLEAR FLOOR SPACES AT | | | APPLIANCES AND FIXTURES PER THE FBC-ACCESSIBILITY SECS. | | | 305 & 306.THE MAXIMUM COUNTER HEIGHT SHALL BE 34 INCHES | | | PER FAC SEC. 606.3. THE DRYER SHALL COMPLY WITH SEC.611 | | | OF THE FBC-ACCESSIBILITY. | | | 2) THE RANGE IN THE BREAKROOM SHALL COMPLY WITH 2014 | | | FBC-ACCESSIBILITY SECS. 305, 804.6.4 -804.6.5.3. SHOW | | | COMPLIANCE ON THE PLANS.THE MAXIMUM COUNTER HEIGHT | | | SHALL BE 34 INCHES. | | | 3) A SERVICE SINK IS REQUIRED PER 2014 FBC-PLUMBING | | | TABLE 403.1. SHOW THE LOCATION OF THE SERVICE SINK ON | | | THE FLOOR PLAN AND THE SANITARY AND WATER RISERS. WPB | | | AMEND. TO FBC SEC. 107.2.1. | | | 4) SUBMIT AN ENLARGED FLOOR PLAN OF THE TOILET ROOMS | | | AND SHOW THE CLEAR INSIDE DIMENSIONS OF THE TOILET | | | ROOMS, SHOWER, FIXTURE CLEARANCES, ETC. ALL TOILET | | | ROOMS & BATHING ROOMS SHALL COMPLY WITH 2014 | | | FBC-ACCESSIBILITY SEC.213.604, 606, 608.THE MINIMUM | | | WIDTH OF A SINGLE USER TOILET ROOM SHALL BE 85 INCHES | | | IF BUILT PERFECT; 86 INCHES ALLOWS FOR TOLERANCES. SEE | | | TOILET ROOMS # 104 & 105. | | | 5) SUBMIT ELEVATION DETAILS FOR ALL HANDICAP ACCESSIBLE | | | FIXTURES, GRAB BARS, SHOWER CONTROLS, ETC.SHOW ALL | | | MEASUREMENTS FROM THE FINISHED FLOOR TO THE TOP OF THE | | | GRAB BARS, THE DISTANCE FROM ADJACENT WALLS, | | | ETC.FBC-ACCESS SECS.604.2,609. | | | 6)THE FIRST FLOOR SANITARY SYSTEM DESIGN FOR TOILET | | | ROOMS #104, 105 AND THE SECOND FLOOR DOES NOT COMPLY | | | WITH SEC. 912.1 FOR WET VENTING. WET VENTED FIXTURES IN | | | BATHROOM GROUPS SHALL BE LOCATED ON THE SAME FLOOR. AS | | | DRAWN, THERE ARE WATER CLOSETS ON THE FIRST FLOOR BEING | | | WET VENTED BY FIXTURES ON THE SECOND FLOOR AND THE | | | DRINKING FOUNTAINS ARE INSTALLED ON THE WET VENT WHICH | | | IS NOT PERMITTED. | | | 7) THE HIGH UNIT OF THE DRINKING FOUNTAINS WILL | | | PROBABLY REQUIRE A CANE TOUCH SKIRT TO COMPLY WITH | | | FBC-ACCESSIBILITY SEC.307.2 FOR THE PROTRUDING OBJECTS | | | GUIDELINES. | | | 8) THE SHOWER IN THE STUDIO BATHROOM #116 C SHALL | | | COMPLY WITH THE FBC- ACCESSIBILITY SECS.213.3.6 & | | | 608.2.1.THE SHOWER DIMENSIONS SHALL BE 36" X 36" FOR A | | | TRANSFER TYPE SHOWER.THESE DIMENSIONS ARE ABSOLUTE AND | | | ARE NOT MINIMUMS. | | | 9) SHT. P-3 - THE WET VENT FOR THE WATER CLOSET IN ROOM | | | # 116 C AND ROOM #122 DOES NOT COMPLY WITH 2014 | | | FBC-PLUMBING SEC.912 FOR A HORIZONTAL WET VENT.THE | | | DRINKING FOUNTAINS IN THE BATHROOM LOBBY AND THE STUDIO | | | KITCHEN SINK SHALL CONNECT TO THE HORIZONTAL DRAIN | | | DOWNSTREAM OF THE WET VENT. | | | | | | PLEASE CALL ME TO SET UP AN APPOINTMENT TO REVIEW THE | | | COMMENTS. | | | | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2015-09-03 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-09-03 |
Time |
06:23 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-09-01 |
Time |
05:37 |
Sent To |
|
|
| Notes |
| 2015-09-01 10:13:57 | 1) SHT. FP-1 - THE BREAK ROOM SINK SHALL COMPLY WITH | | | 2014 FBC-ACCESSIBILITY SECS. 212, 212.3, 804. SHOW | | | COMPLIANCE ON THE PLANS. | | | 2) THE RANGE IN THE BREAKROOM SHALL COMPLY WITH 2014 | | | FBC-ACCESSIBILITY SEC.804.6.4 -804.6.5.3. SHOW | | | COMPLIANCE ON THE PLANS. | | | 3) A DRINKING FOUNTAIN IS REQUIRED IN A BUSINESS | | | OCCUPANCY PER THE 2014 FBC-PLUMBIING TABLE 403.1.THIS | | | IS NOT A RESTAURANT AND THE EXCEPTION FOR NOT PROVIDING | | | A DRINKING FOUNTAIN IS FOR RESTAURANTS ONLY PER 2014 | | | FBC -PLUMBING SEC.410.3. A MINIMUM OF TWO DRINKING | | | FOUNTAINS ARE REQUIRED PER 2014 FPC TABLE 403.1, | | | FOOTNOTE # (E) & 2014 FAC SEC.211.2. | | | 4) A MINIMUM OF 3 WATER CLOSETS FOR THE MALES AND 3 | | | WATER CLOSETS FOR THE FEMALES ARE REQUIRED FOR AN | | | OCCUPANT LOAD OF 200 PER THE 2014 FBC-PLUMBING TABLE | | | 403.1. | | | 5) A SERVICE SINK IS REQUIRED PER 2014 FBC-PLUMBING | | | TABLE 403.1. SHOW THE LOCATION OF THE SERVICE SINK ON | | | THE FLOOR PLAN AND THE SANITARY AND WATER RISERS. WPB | | | AMEND. TO FBC SEC. 107.2.1. | | | 6) SUBMIT AN ENLARGED FLOOR PLAN OF THE TOILET ROOMS | | | AND SHOW THE CLEAR INSIDE DIMENSIONS OF THE TOILET | | | ROOMS, SHOWER, FIXTURE CLEARANCES, ETC. ALL TOILET | | | ROOMS & BATHING ROOMS SHALL COMPLY WITH 2014 | | | FBC-ACCESSIBILITY SEC.213.604, 606, 608. | | | 7) SUBMIT ELEVATION DETAILS FOR ALL HANDICAP ACCESSIBLE | | | FIXTURES, GRAB BARS, SHOWER CONTROLS, ETC.SHOW ALL | | | MEASUREMETS FROM FINISH FLOOR.WPB AMEND. TO 2014 FBC | | | SEC. 107.2.1. | | | 8) SHT. P-2 SHOWS 2 WATER LINES TO A WATER METER. | | | INDDICATE ON THE PLANS IF THERE ARE TTWO SEPARATE WATER | | | METERS SERVING THIS PROPERTY OR IF THESE TWO LINES ARE | | | INTERCONNECTED AND CONTINUE TO CONNECT TO ONE METER. IF | | | THEY ARE INTERCONNECTED, SHOW ALL THE PIPING TO THE | | | POINT OF INTERCONNECTION.WPB AMEND TO FBC SEC. 107.2.1. | | | 9) THE FIRST FLOOR SANITARY SYSTEM DESIGN FOR TOILET | | | ROOMS #104, 105 AND THE SECOND FLOOR DOES NOT COMPLY | | | WITH SEC. 912.1 FOR WET VENTING. WET VENTED FIXTURES IN | | | BATHROOM GROUPS SHALL BE LOCATED ON THE SAME FLOOR. AS | | | DRAWN, THERE ARE WATER CLOSETS ON THE FIRST FLOOR BEING | | | WET VENTED BY FIXTURES ON THE SECOND FLOOR. | | | 10) THE DISHWASHER SHALL BE INSTALLED IN ACCORDANCE | | | WITH THE 2014 FBC-PLUMBING SEC.802.1.6. | | | 11) SHT. P-3 - SUBMIT 2 COPIES OF THE MANUFACTURER'S | | | SPECIFICATIONS FOR ALL GAS | | | APPLIANCES/EQUIPMENT.APPLIANCES/EQUIPMENT SHALL BE | | | LISTED AND LABELED PER 2014 FBC-GAS CODE, SEC.301.3. | | | 12) THE GAS GENERATOR SHALL COMPLY WITH NFPA 37 AND | | | COMPLY WITH UL 2200. 2010 FGC SEC.616.1. | | | 13) SUBMIT AN ISOMETRIC DRAWING THAT CLEARLY SHOWS THE | | | LENGTH OF ALL CUT SECTIONS OF PIPE PER FBC-2014 FUEL | | | GAS, SECS. 402.4.1, 402.4.2. | | | 14) SHOW TYPE OF PIPING MATERIAL BEING INSTALLED, ALL | | | PIPE SIZES, AND THE EHD NUMBER OF CORRUGATED STAINLESS | | | STEEL TUBING FOR EACH PIPE SIZE IF BEING USED. WPB | | | AMENDMENTS TO FBC SEC. 107.2.1. | | | 15) SHOW THE BTU LOAD OF EACH APPLIANCE AND THE TOTAL | | | BTU LOAD ON THE SYSTEM. REFER TO THE FBC-2014 FUEL GAS | | | SECS. 401.8 THRU 402.6.1 AND TABLES 402.4(1) THRU | | | 402.4(37). | | | 16) SHOW THE DISTANCE FROM THE POINT OF DELIVERY, | | | (METER), TO THE MOST REMOTE OUTLET IN THE BUILDING | | | AND/OR SYSTEM PER THE FBC-2014 FUEL GAS APPENDIX A ? | | | USE OF CAPACITY SECTION A.3.1(4) & 2014 FUEL GAS CODE | | | SEC. 402.4.1. | | | 17) SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE | | | FBC-2014 FUEL GAS CODE SEC. 304. | | | 18) INDICATE THE DELIVERY PRESSURE (PSI) PER FBC-2014 | | | FUEL GAS SEC. 402.2. IF NATURAL GAS SPECIFY .5 PSI OR 2 | | | PSI. | | | 19) SUBMIT A DETAIL SHOWING THE TYPE, LOCATION, SIZE | | | AND TERMINATION OF THE GAS VENTS PER FBC-2014 FUEL GAS | | | CODE SEC. 502 THRU 505. | | | 20) SHT. P-4 - OVERFLOW SCUPPERS SHALL BE LOCATED NO | | | LESS THAN 2 INCHES NOR MORE THAN 4 INCHES ABOVE THE | | | FINISHED ROOF SURFACE PER 2014 FBC SEC. 1503.4.2.1.THE | | | SCUPPER DETAIL SHOWS THE BOTTOM OF THE SCUPPER LEVEL | | | WITH THE ROOF. | | | 21) INDICATE ON THE PLAN THAT THE ROOF DRAINAGE AREA | | | INCLUDES 1/2 OF THE AREA OF ALL VERTICAL WALLS THAT | | | DIVERT RAINWATER TO THE ROOF. 2014 FBC-P SEC.1106.4. | | | 22) CLEANOUTS ARE REQUIRED IN THE BASE OF THE RAINWATER | | | LEADERS. FBC-P SEC. 1101.8. | | | 23) AN OIL SEPARATOR SHALL BE INSTALLED FOR THE | | | ELEVATOR PIT IN ACCORDANCE WITH 20144 FPC SEC.1003.4. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
P |
Date |
2016-02-02 |
|
|
Cont ID |
|
| Sent By |
dkittred |
Date |
2016-02-03 |
Time |
09:20 |
Rev Time |
0.00 |
| Received By |
dkittred |
Date |
2016-02-02 |
Time |
09:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
F |
Date |
2016-01-21 |
|
|
Cont ID |
|
| Sent By |
dkittred |
Date |
2016-01-21 |
Time |
12:14 |
Rev Time |
0.00 |
| Received By |
dkittred |
Date |
2016-01-14 |
Time |
13:35 |
Sent To |
|
|
| Notes |
| 2016-01-21 12:19:49 | PLANNING AND ZONING COMMENTS: ***FAILED*** | | | | | | 1/21/16 | | | | | | [NOTE: REVISED PLANS CONTAIN ONLY THE BUILDING | | | IMPROVMENTS AND COMMENTS BELOW ARE REFLECTIVE OF THE | | | INFORMATION SUBMITTED. SEPARATE PERMIT(S) REQUIRED FOR | | | PAVING/STRIPING, SITE LIGHTING, LANDSCAPING, ETC.] | | | | | | 1. SITE PLAN ON THE COVERSHEET IS NOT UP TO DATE. | | | PLEASE PROVIDE UP TO DATE SITE PLAN CONFIGURATION ON | | | THE COVER SHEET | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT: | | | | | | DANIELLE J. KITTREDGE, AICP | | | SENIOR PLANNER | | | PLANNING & ZONING DIVISION | | | PHONE: (561)-822-1443 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2015-12-31 |
|
|
Cont ID |
|
| Sent By |
dkittred |
Date |
2015-12-31 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
dkittred |
Date |
2015-12-30 |
Time |
11:53 |
Sent To |
|
|
| Notes |
| 2015-12-31 11:19:09 | PLANNING AND ZONING COMMENTS: | | | | | | ALL PREVIOUS COMMENTS ADDRESSED WITH EXCEPTION OF THE | | | FOLLOWING: | | | | | | 1. [ORIGINAL COMMENT #19 - EASEMENT CONSENT FORM FROM | | | UTILITY PROVIDERS WILL BE REQUIRED FOR WORK WITHIN THE | | | PROPOSED 10 FOOT EASEMENT AREA. | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UP | | | LOADS/SITES/33/2013/09/EASEMENT-CONSENT-FORM.PDF] - | | | RESPONSE INDICATED THIS REQUIREMENT WAS 'TO BE PROVIDED | | | BY APPLICANT'. THERE WERE NO FORMS PROVIDED. PLEASE | | | SUBMIT FORMS AND I WILL UPDATE MY COMMENT TO PASSED. | | | | | | 2. PLEASE ALSO NOTE THAT WHILE SHEET C OF 15 HAS A | | | CORRECT SITE PLAN SHOWN FOR THE SITE, SHEET C OF 31 HAS | | | THE OLD SITE PLAN DEPICTED. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT: | | | | | | DANIELLE J. KITTREDGE, AICP | | | SENIOR PLANNER | | | PLANNING & ZONING DIVISION | | | PHONE: (561)-822-1443 | | | EMAIL: [email protected] | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2015-10-30 |
|
|
Cont ID |
|
| Sent By |
dkittred |
Date |
2015-10-30 |
Time |
10:10 |
Rev Time |
0.00 |
| Received By |
dkittred |
Date |
2015-10-28 |
Time |
09:22 |
Sent To |
|
|
| Notes |
| 2015-10-30 10:10:33 | PLANNING AND ZONING COMMENTS: ***FAILED*** | | | | | | 10/30/15 | | | | | | [ORIGINAL COMMENT #1] - STILL WAITING FOR RECORDED | | | DISCLAIMER FOR THE ABANDONMENT (NO ACTION REQUIRED BY | | | THE APPLICANT, CITY IS PROCESSING). UTILITY EASEMENT | | | DOCUMENT HAS BEEN RECORDED AND COPY ADDED TO THE FILE. | | | | | | [ORIGINAL COMMENT #13 - SHEET SE1 INCLUDE A NOTE "THIS | | | SHEET PROVIDED FOR SITE LIGHTING ELECTRICAL CONNECTIONS | | | ONLY, PHOTOMETRICS BY OTHERS". PLAN INCLUDES | | | PHOTOMETRIC NUMBERS. EITHER ADJUST STATEMENT OR PROVIDE | | | SEPARATE DOCUMENT PROVIDING PHOTOMETRICS FOR THE SITE.] | | | - RESPONSE LETTER INDICTED THIS WOULD BE ADDRESSED IN | | | THE BUILDING PLANS, HOWEVER, THERE WAS NO SHEET | | | INCLUDED. IF SITE LIGHTING IS REQUIRED TO BE A SEPARATE | | | PERMIT THIS ITEM CAN BE ADDRESSED WHEN SUBMITTING FOR | | | THE SEPARATE SITE LIGHTING PERMIT, OTHERWISE, PLEASE | | | ADDRESS. | | | | | | [ORIGINAL COMMENT #16 - SHEET S1 - INCLUDE ELEVATOR | | | SHAFT ON ELEVATIONS AND DIMENSION HEIGHT FOR REVIEW.] - | | | RESPONSE LETTER INDICATED THIS WOULD BE ADDRESSED IN | | | THE BUILDING PLANS, HOWEVER, THERE WAS NO REVISION TO | | | THE ELEVATION TO SHOW HEIGHT OF ELEVATOR SHAFT | | | ADDITION. PLEASE REVISE. | | | | | | [ORIGINAL COMMENT #19 - EASEMENT CONSENT FORM FROM | | | UTILITY PROVIDERS WILL BE REQUIRED FOR WORK WITHIN THE | | | PROPOSED 10 FOOT EASEMENT AREA. | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UP | | | LOADS/SITES/33/2013/09/EASEMENT-CONSENT-FORM.PDF] - | | | RESPONSE INDICATED THIS REQUIREMENT WAS 'NOTED', | | | HOWEVER, IN ORDER TO BE GRANTED A PERMIT FOR ANY WORK | | | SHOWN WITHIN THE UTILITY EASEMENT, THESE FORMS NEED TO | | | BE SUBMITTED. | | | | | | [NEW COMMENT #1] - PLAN NEEDS TO INDICATE COMPLIANCE | | | WITH ZLDR SEC. 94-305(E) REGARDING VISIBILITY AT | | | INTERSECTIONS WHICH WOULD BE APPLICABLE TO THE WEBSTER | | | AVENUE AND BUNKER ROAD INTERSECTION CORNERS. | | | | | | [NEW COMMENT #2] - INCLUDE DETAIL FOR BICYCLE PARKING. | | | INCLUDE RACK STYLE ('WAVE'-STYLE IS NOT PERMITTED) AND | | | PAD MINIMUM PAD/PLACEMENT DIMENSIONS. PLEASE CONTACT ME | | | FOR HANDOUT SHEETS ON THE MINIMUM REQUIREMENTS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT: | | | | | | DANIELLE J. KITTREDGE, AICP | | | SENIOR PLANNER | | | PLANNING & ZONING DIVISION | | | PHONE: (561)-822-1443 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2015-09-21 |
|
|
Cont ID |
|
| Sent By |
dkittred |
Date |
2015-09-21 |
Time |
17:46 |
Rev Time |
0.00 |
| Received By |
dkittred |
Date |
2015-09-17 |
Time |
11:55 |
Sent To |
|
|
| Notes |
| 2015-09-21 17:45:00 | PLANNING AND ZONING COMMENTS: ***FAILED*** | | | | | | 9/21/15 | | | | | | 1. ALLEY ABANDONMENT ON PROPOSED SITE PLAN IS PENDING | | | SUBMITTAL OF FINAL SIGNED EASEMENT DOCUMENT AND | | | SUBSEQUENT RECORDING OF BOTH THE EASEMENT DOCUMENT AND | | | DISCLAIMER OF INTEREST IN THE ALLEY. RECORDING OF THESE | | | DOCUMENTS IS REQUIRED PRIOR TO ZONING APPROVAL OF THESE | | | PLANS. | | | | | | 2. NO GATES OR DOORS ARE PERMITTED TO OPEN OVER A | | | PROPERTY LINE INTO A RIGHT-OF-WAY. THIS INCLUDES | | | DUMPSTER GATE AND ADA ACCESS GATE IN THE WEST PARKING | | | LOT. PLEASE REVISE PLAN. | | | | | | 3. DUMPSTER LOCATION/ORIENTATION IS NOT RECOMMENDED AND | | | ENGINEERING/SANITATION REVIEW IS REQUIRED FOR FINAL | | | PLACEMENT. EXISTING CONFIGURATION WILL REQUIRE THE | | | TRUCK TO BLOCK/OBSTRUCT BOTH LANES OF TRAFFIC ON BUNKER | | | ROAD FOR PICK-UP. CONSIDER A DUMPSTER PICK-UP | | | ORIENTATION INTERNAL TO THE PARKING LOT OR LOCATING THE | | | DUMPSTER WITHIN THE PROPOSED SOUTHEAST PARKING SPACES | | | ON THE NORTH SIDE OF THE BUILDING. | | | | | | 4. SHEET C-2 - PROVIDE PARKING ANGLE FOR THE ANGLED | | | PARKING SPACES. | | | | | | 5. SHEET C-3 - CORRECT ADA SPACE STRIPING DETAIL TO | | | SHOW DOUBLE LINES CONNECTED AT THE BOTTOM; 4? WHITE | | | STRIP FOR AISLE HATCHING; AND ACCESSIBILITY SYMBOL TO | | | BE PAINTED IN WHITE. | | | | | | 6. PROVIDE A NOTATION ON THE PLAN INDICATING EXISTING | | | NUMBER OF PARKING SPACES AND PROPOSED NUMBER OF PARKING | | | SPACES. | | | | | | 7. INCLUDE A CHART OF DATA INDICATING PERCENT OF OPEN | | | SPACE (INCLUDES ANY AREA WITHOUT A VERTICAL STRUCTURE), | | | LANDSCAPE AREA, IMPERVIOUS SURFACE, AND BUILDING | | | COVERAGE. | | | | | | 8. PROVIDE BICYCLE PARKING AT A RATE OF 1 BICYCLE | | | PARKING SPACE PER 20 VEHICLE PARKING SPACES. | | | | | | 9. AS PART OF THE ALLEY ABANDONMENT, A 10' UTILITY | | | EASEMENT IS BEING RESERVED ALONG THE SOUTH SIDE OF THE | | | PROPERTY. PLEASE REVISE PLAN TO SHOW LOCATION OF THE | | | UTILITY EASEMENT. | | | | | | 10. 1 FOOT RESERVED STRIP ALONG THE SOUTH SIDE OF THE | | | EASTERN PROPERTY IS NOT INCLUDED WITHIN THE SUBJECT | | | PROPERTY. PLEASE MODIFY DRAWINGS TO DEPICT THIS AREA | | | OUTSIDE OF THE SITE. | | | | | | 11. PROPOSED CHAIN LINK FENCE ALONG THE SOUTH SIDE OF | | | THE PROPERTY IS SHOWN BEYOND THE PROPERTY LINE. PLEASE | | | LOCATED FENCE ON OR WITHIN THE PROPERTY LINE. | | | | | | 12.INDICATE IF LIGHT POLES ON THE PROJECT SITE ARE NEW | | | OR EXISTING. PROVIDE SETBACK FOR FREESTANDING LIGHT | | | POLES. NEW LIGHT POLES MUST BE A MINIMUM OF 5 FEET FROM | | | THE PROPERTY LINE (GC ZONING DISTRICT). | | | | | | 13. SHEET SE1 INCLUDE A NOTE "THIS SHEET PROVIDED FOR | | | SITE LIGHTING ELECTRICAL CONNECTIONS ONLY, PHOTOMETRICS | | | BY OTHERS". PLAN INCLUDES PHOTOMETRIC NUMBERS. EITHER | | | ADJUST STATEMENT OR PROVIDE SEPARATE DOCUMENT PROVIDING | | | PHOTOMETRICS FOR THE SITE. | | | | | | 14. SCREENING REQUIRED AROUND MECHANICAL EQUIPMENT | | | (I.E. PROPOSED GENERATOR, AC UNITS) LOCATED ON THE EAST | | | SIDE OF THE BUILDING. PLEASE INDICATE ON PLAN HOW THIS | | | AREA WILL BE SCREENED IN ACCORDANCE WITH ZLDR SEC. | | | 94-444(B). | | | | | | 15. INCLUDE SETBACK OF NEW CONCRETE PAD ON THE EAST | | | SIDE OF THE BUILDING AND SETBACK OF NEW PAVER AREAS ON | | | THE SOUTH SIDE OF THE BUILDING. | | | | | | 16. SHEET S1 - INCLUDE ELEVATOR SHAFT ON ELEVATIONS AND | | | DIMENSION HEIGHT FOR REVIEW. | | | | | | 17. SHEET C-1 - REMOVE OR MODIFY THE NOTATION "PORTION | | | OF EXISTING BUILDING TO BE REMOVED AND RECONSTRUCTED | | | ONE FOOT SOUTH OF THE PROPERTY LINE". THE PORTION OF | | | THE BUILDING EXTENDING INTO THE ALLEY BEING ABANDONED | | | HAS BEEN REMOVED AND ZONING CODE WOULD NOT PERMIT FOR | | | RECONSTRUCTION OF THIS PORTION OF THE BUILDING BACK | | | WITH A ONE FOOT SETBACK. | | | | | | 18. THE VALUE OF THE CONSTRUCTION ($1.1 MILLION) | | | EXCEEDS 50% OF THE STRUCTURE'S VALUE ($447,449) | | | ACCORDING TO THE P.B.C. PROPERTY APPRAISER'S OFFICE; | | | THEREFORE, PURSUANT TO SECTION 94-441(C)(2) OF THE | | | ZONING AND LAND DEVELOPMENT REGULATIONS (ZLDR), THE | | | LANDSCAPE ON THE SITE SHALL BE IN COMPLIANCE WITH ALL | | | APPLICABLE REGULATIONS FOUND IN ARTICLE XIV OF THE | | | ZLDR. PRIOR TO ZONING APPROVAL A SEPARATE PERMIT IS TO | | | BE SUBMITTED FOR LANDSCAPING AND IRRIGATION. A TREE | | | ALTERATION PERMIT IS REQUIRED THROUGH THE PLANNING | | | DIVISION FOR REMOVAL OR RELOCATION OF ANY TREES. HTTP:/ | | | /WPB.ORG/PLANNING/WP-CONTENT/UPLOADS/SITES/37/2013/04/T | | | REE-ALTERATION-PERMIT-APPLICATION-REVISED-05.21.2015.PD | | | F | | | | | | 19. EASEMENT CONSENT FORM FROM UTILITY PROVIDERS WILL | | | BE REQUIRED FOR WORK WITHIN THE PROPOSED 10 FOOT | | | EASEMENT AREA. HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UP | | | LOADS/SITES/33/2013/09/EASEMENT-CONSENT-FORM.PDF | | | | | | 20. A CURBCUT ON THE NORTHEAST CORNER OF PROPERTY IS | | | BEING CLOSED OFF, BUT CURBCUT IS BEING LEFT IN THE | | | RIGHT-OF-WAY. REVISE PLANS TO RESTORE AREA TO SIDEWALK, | | | GRASS STRIP, AND CURB. | | | | | | 21. SHEET C-4 - SECTION E-E DEPICTS ROLL GATES/FENCING | | | LOCATED OUTSIDE OF THE PROPERTY LINE. PLEASE REVISE TO | | | SHOW GATES/FENCING LOCATED ON THE SUBJECT PROPERTY. | | | | | | | | | RECOMMENDATIONS FOR CONSIDERATION: | | | | | | A. INSTALL FENCING ON THE INSIDE OF THE LANDSCAPE | | | BUFFER ALONG STREET FRONTAGES. | | | | | | B. SCREENING ON FENCING ALONG RIGHT-OF-WAYS IS NOT | | | RECOMMENDED ESPECIALLY ON THE FENCING AROUND THE MAIN | | | BUILDING. | | | | | | C. IF UTILIZING CHAIN LINK FENCING CONSIDER BLACK | | | COATED VINYL. PLEASE CORRESPOND APPROPRIATE TYPE | | | FENCING ADJACENT TO RESIDENTIAL USES IN ACCORDANCE WITH | | | ZLDR SEC. 94-443 SCREENING AND BUFFERING REQUIREMENTS | | | THAT WILL BE REVIEWED AS PART OF THE LANDSCAPE PERMIT. | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT: | | | | | | DANIELLE J. KITTREDGE, AICP | | | SENIOR PLANNER | | | PLANNING & ZONING DIVISION | | | PHONE: (561)-822-1443 | | | EMAIL: [email protected] | | | | | 2015-09-04 16:15:17 | 9/4/15 - RETURNED PLANS OT C25, WILL PICK UP NEXT WEEK | | | TO COMPLETE REVIEW. DK | | 2015-08-31 11:07:34 | 8/31/15 |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |