Plan Review Details - Permit 15081103
Plan Review Stops For Permit 15081103
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-10-28 Cont ID  
Sent By jwitmer Date 2015-10-28 Time 08:01 Rev Time 0.00
Received By jwitmer Date 2015-10-28 Time 07:30 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-09-26 Cont ID  
Sent By jwitmer Date 2015-09-26 Time 15:31 Rev Time  
Received By jwitmer Date 2015-09-26 Time 14:16 Sent To  
Notes
2015-09-26 14:48:00BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15081103
 ADD: 1641 WORTHINGTON RD. SUITE # ?????
 CONT: TBD
 TEL: (954)993-4742 / STEVE MORIN
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W * 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION,
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3. COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: SAT. SEPT. 26/ 2015
 ACTION: DENIED
  
 1) NEITHER THE PERMIT APPLICATION NOR THE PLANS PROVIDE
 WHAT THE SUITE NUMBER IS GOING TO BE FOR THIS TENANT.
 2014 FLORIDA BUILDING CODE W * 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION, 107.2.1. CONSTRUCTION DOCUMENTS SHALL
 BE OF SUFFICIENT CLARITY TO INDICATE THE LOCATION,
 WHERE WORK IS TO BE PREFORMED.
 2014 FBC-B 501.2 ADDRESS IDENTIFICATION.
  
 2) PLEASE PROVIDE THE TOTAL SQUARE FOOTAGE OF THE LARGE
 MEETING ROOM 03K06, THE HUDDLE ROOM 03K09, MEDIUM
 MEETING ROOM 03K09,
 THE BOARD ROOM 03E13 AND THE PANTRY ROOM NUMBER 03B13.
 IT APPEARS ALL OF THESE ROOMS ARE MEETING ROOMS AND THE
 COMBINED SQUARE FOOTAGE THEY WOULD BE CLASSIFIED AS
 ASSEMBLY. THIS MAY BE CONSIDERED A MIXED OCCUPANCY
 BETWEEN A3 ASSEMBLY AND BUSINESS OCCUPANCY. PLEASE
 PROVIDE THE TOTAL SQ. FOOTAGE FOR THIS FLOOR NOT TENANT
 SPACE, IF THE ASSEMBLY OCCUPANCY SQUARE FOOTAGE IS MORE
 THAN 10 PER CENT OF THE FLOOR AREA FOR THE BUILDING
 INCLUSIVE OF ALL ASSEMBLY AREAS ON THIS FLOOR, THEN IT
 IS A MIXED OCCUPANCY AND THE DESIGNER OF RECORD WILL
 NEED TO INDICATE COMPLIANCE WITH EITHER 508.3
 NONSEPARATED OCCUPANCIES OR 508.4 SEPARATION OF
 OCCUPANCIES.
  
 3) SHEET M01.01 NOTE # 8 INDICATES NEW REFRIGARANT
 LINES ARE GOING TO BE INSTALLED UP THROUGH THE ROOF.
 WHAT THIS PLAN DOES NOT PROVIDE IS HOW THESE LINES ARE
 GOING TO BE RUN. SHEET A02.03 INDICATES THE WALL TYPE
 AS DB3. ON SHEET A12.00 THIS IS NOT A RATED WALL THE
 ACTUAL RATED STAIR ENCLOSURE WALL IS A SEPARATE AND
 SHOWING AS RATED. THE UNKNOWN IS THIS A SHAFT WALL,
 CHASE PLEASE PROVIDE MORE DETAIL IN THIS AREA HOW CODE
 COMPLIANCE WILL BE MET. IS THERE ANOTHER FLOOR ON TOP
 OF THIS FLOOR IF SO HOW WILL THE PENETRATION BE SEALED.
 2014 FBC-B 717.6.1 THROUGH PENETRATIONS.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2015-11-09 Cont ID  
Sent By albarran Date 2015-11-09 Time 15:55 Rev Time 0.00
Received By albarran Date 2015-11-09 Time 15:37 Sent To I
Notes
2015-11-09 15:56:24ALL PREVIOUSLY MENTIONED DEFICIENCIES HAVE BEEN
 SATISFACTORILY ADDRESSED.

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2015-10-29 Cont ID  
Sent By albarran Date 2015-10-29 Time 13:30 Rev Time 0.00
Received By albarran Date 2015-10-29 Time 13:02 Sent To I
Notes
2015-10-29 13:40:54THE PLANS FOR THE ABOVE MENTIONED PERMIT APPLICATION
 HAVE BEEN REVIEWED FOR COMPLIANCE WITH THE 2011 EDITION
 OF THE NEC, (NATIONAL ELECTRICAL CODE); THE 5TH EDITION
 OF THE FBC, (FLORIDA BUILDING CODE) AS APPLICABLE AND
 BELOW ARE THE DEFICIENCIES NOTED.
  
 THOUGH THE PREVIOUSLY MENTIONED DEFICIENCIES HAVE BEEN
 ADDRESSED, THE NEW PLANS HAVE A COUPLE OF ITEMS NEEDING
 CORRECTION:
 1. PANEL H3 DOES NOT APPEAR ON THE RISER DIAGRAM AS
 SUCH, IT IS MISLABELED AS HP3. CORRECT TO MATCH.
 2. THE RISER DIAGRAM REFLECTS A PANEL L3C, BUT THERE IS
 NOT PANEL SCHEDULE FOR IT ON THE NEW PLANS.
  
 THE PLANS SHALL BE REVISED TO ADDRESS THE HEREIN
 MENTIONED ITEMS; ONCE CORRECTED SHALL BE RESUBMITTED
 FOR ANOTHER REVIEW.
  
 WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR
 RE-SUBMITTAL, YOU ARE REQUIRED TO PROVIDE A RESPONSE
 LETTER (NARRATIVE) ADDRESSING EACH ITEM ALONG WITH THE
 STANDARD CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE
 INSERT CORRECTED PAGES INTO THE SUBMITTAL AND LEAVE THE
 PREVIOUSLY REVIEWED SHEETS FOR COMPARISON.
 CLOUDING THE CHANGES WILL BE GREATLY APPRECIATED.
  
 IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO
 CONTACT ME DIRECTLY.
  
 THANK YOU,
 MIKE ALBARRAN
 ELECTRICAL PLANS EXAMINER
 .
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2015-10-02 Cont ID  
Sent By albarran Date 2015-10-02 Time 12:15 Rev Time 0.00
Received By albarran Date 2015-10-02 Time 11:34 Sent To I
Notes
2015-10-02 12:14:58PLEASE NOTE THAT I, MIKE ALBARRAN, ELECTRICAL PLANS
 EXAMINER HAVE COMPLETED THE SECOND ELECTRICAL REVIEW OF
 THE ABOVE MENTIONED JOB. BELOW ARE THE COMMENTS WITH
 REGARDS TO THE REQUIRED CORRECTIONS. THE PLANS SHALL BE
 REVISED TO ADDRESS FOLLOWING ITEMS; ONCE CORRECTED
 SHALL BE RESUBMITTED FOR ANOTHER REVIEW.
 1. FIRE ALARM WORK SHALL BE PERFORMED UNDER SEPARATE
 PERMIT.
 2. MISSING EXIT LIGHT ON OPPOSITE SIDE OF THE OPEN AREA
 CORRIDOR.
 3. CORRECT FIXTURE SCHEDULE TO C-EM TYPE TO INCLUDE THE
 BATTERY PACK.
 4. PROVIDE CIRCUIT DIRECTORY FOR THE ODD SIDE OF PANEL
 L3A.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND LEAVE THE
 PREVIOUSLY REVIEWED SHEETS.
  
 IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO
 CONTACT ME DIRECTLY.
  
 THANK YOU
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2015-09-02 Cont ID  
Sent By pleduc Date 2015-09-02 Time   Rev Time 0.00
Received By pleduc Date 2015-08-31 Time 16:15 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2015-11-09 Cont ID  
Sent By albarran Date 2015-11-09 Time 15:58 Rev Time 0.00
Received By albarran Date 2015-11-05 Time 12:21 Sent To M
Notes
2015-11-09 16:00:0811/9/15 PASSED ELECTRICAL REVIEW. STEVE MORON NOTIFIED
 VIA EMAIL. SENT TO LARGE READY BIN "T". MA

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-10-29 Cont ID  
Sent By albarran Date 2015-10-29 Time 13:45 Rev Time 0.00
Received By albarran Date 2015-10-19 Time 17:46 Sent To  
Notes
2015-10-29 13:51:0910/29/15 FAILED ELECTRICAL REVIEW AS NOTED. CONTRACTOR
 NOTIFIED VIA EMAIL. SENT TO LARGE DENIED BIN "T". MA
2015-10-19 17:47:35C31

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-10-02 Cont ID  
Sent By albarran Date 2015-10-02 Time 12:15 Rev Time 0.00
Received By albarran Date 2015-08-28 Time 11:19 Sent To  
Notes
2015-10-02 12:19:4310/2/15 FAILED ELECTRICAL REVIEW. STEVE MORIN NOTIFIED
 VIA EMAIL. SENT TO LARGE DENIED BIN "TBD". MA
2015-08-28 11:19:16C32

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2015-11-09 Cont ID  
Sent By albarran Date 2015-11-09 Time 16:00 Rev Time 0.00
Received By ccole Date 2015-11-09 Time 13:51 Sent To E
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2015-10-27 Cont ID  
Sent By ccole Date 2015-10-27 Time 15:17 Rev Time 0.00
Received By ccole Date 2015-10-27 Time 15:17 Sent To  
Notes
2015-10-27 15:19:262ND REVIEW: FBC 2014 MECHANICAL
 PERMIT #15081103
 10/27/15
  
 1) THE REQUESTED SIZING CALCULATIONS FOR THE DAIKIN AC
 SYSTEM WERE NOT PROVIDED. IN RESPONSE TO THE COMMENT,
 THE DESIGN PROFESSSION IS INDICATING EQUIPMENT CUT
 SHEETS WERE USED TO ESTABLISH THE HEAT LOAD- PLEASE
 PROVIDE THE CUT SHEETS AS INDICATED.
 2) SHEET M02.00: REMOVE OR REVISE THE UNDERFLOOR
 EQUIPMENT SCHEDULE. THE UNDERFLOOR HEATERS HAVE BEEN
 REPLACED WITH ABOVE CEILING UNITS.
 3) PROVIDE SIZING CALCULATIONS FOR THE NEW ABOVE
 CEILING HEATERS IN COMPLIANCE WITH SECTION C403.2.1
 FBC-14 ENERGY CONSERVATION.
 4) PROVIDE SUPPORT AND CONNECTION DETAILS FOR
 INSTALLATION OF THE ABOVE CEILING HEATERS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2015-09-04 Cont ID  
Sent By ccole Date 2015-09-04 Time 15:09 Rev Time 0.00
Received By ccole Date 2015-09-04 Time 15:09 Sent To  
Notes
2015-09-04 15:58:221ST REVIEW: FBC 2014 MECHANICAL
 PERMIT #15081103
 9/4/15
  
 1) PROVIDE AC COOLING AND HEATING CALCULATIONS FOR THE
 NEW DAIKIN SPLIT SYSTEM. REFER TO SECTION C403.2.1
 FBC-14 ENERGY CONSERVATION- CALCULATION OF HEATING AND
 COOLING LOADS.
 DESIGN LOADS SHALL BE DETERMINED IN ACCORDANCE WITH THE
 PROCEDURES DESCRIBED IN THE ASHRAE/ACCA STANDARD 183 OR
 ACCA MANUAL N AND SHALL BE ATTACHED TO THE CODE
 COMPLIANCE FORM SUBMITTED TO THE BUILDING DEPARTMENT
 WHEN THE BUILDING IS PERMITTED OR, IN THE EVENT THE
 MECHANICAL PERMIT IS OBTAINED AT A LATER TIME, THE
 SIZING CALCULATION SHALL BE SUBMITTED WITH THE
 APPLICATION FOR THE MECHANICAL PERMIT. HEATING AND
 COOLING LOADS SHALL BE ADJUSTED TO ACCOUNT FOR LOAD
 REDUCTIONS THAT ARE ACHIEVED WHEN ENERGY RECOVERY
 SYSTEMS ARE UTILIZED IN THE HVAC SYSTEM IN ACCORDANCE
 WITH THE ASHRAEHVAC SYSTEMS AND EQUIPMENT HANDBOOK.
 ALTERNATIVELY, DESIGN LOADS SHALL BE DETERMINED BY AN
 APPROVED EQUIVALENT COMPUTATION PROCEDURE, USING THE
 DESIGN PARAMETERS SPECIFIED IN CHAPTER 3.
 2) SHEET M0.1: PLEASE REVIEW AND UPDATE THE OUTDATED
 ASHRAE 62.1 REFERENCE AND CALCULATIONS TO BE IN
 COMPLIANCE WITH THE 2010 STANDARD AS LISTED IN THE
 FBC-14 MECHANICAL.
 3) REFER TO SECTION 301.15 FBC-14 MECHANICAL AND
 PROVIDE THE WIND LOAD DESIGN CRITERIA, AND DETAILS FOR
 TIE DOWN OF THE NEW ROOF TOP CONDENSER: WIND
 RESISTANCE.
 MECHANICAL EQUIPMENT, APPLIANCES AND SUPPORTS THAT ARE
 EXPOSED TO WIND SHALL BE DESIGNED AND INSTALLED TO
 RESIST THE WIND PRESSURES DETERMINED IN ACCORDANCE WITH
 THE FLORIDA BUILDING CODE, BUILDING.
 4) INDICATE HOW ACCESS FOR SERVICING OF THE UNDER FLOOR
 HEATERS IS BEING PROVIDED- REFER TO SECTION 306.4
 APPLIANCES UNDER FLOORS.
 UNDERFLOOR SPACES CONTAINING APPLIANCES SHALL BE
 PROVIDED WITH AN ACCESS OPENING AND UNOBSTRUCTED
 PASSAGEWAY LARGE ENOUGH TO REMOVE THE LARGEST
 APPLIANCE. THE PASSAGEWAY SHALL NOT BE LESS THAN 30
 INCHES (762 MM) HIGH AND 22 INCHES (559 MM) WIDE, NOR
 MORE THAN 20 FEET (6096 MM) IN LENGTH MEASURED ALONG
 THE CENTERLINE OF THE PASSAGEWAY FROM THE OPENING TO
 THE APPLIANCE. A LEVEL SERVICE SPACE NOT LESS THAN 30
 INCHES (762 MM) DEEP AND 30 INCHES (762 MM) WIDE SHALL
 BE PRESENT AT THE FRONT OR SERVICE SIDE OF THE
 APPLIANCE. IF THE DEPTH OF THE PASSAGEWAY OR THE
 SERVICE SPACE EXCEEDS 12 INCHES (305 MM) BELOW THE
 ADJOINING GRADE, THE WALLS OF THE PASSAGEWAY SHALL BE
 LINED WITH CONCRETE OR MASONRY. SUCH CONCRETE OR
 MASONRY SHALL EXTEND A MINIMUM OF 4 INCHES (102 MM)
 ABOVE THE ADJOINING GRADE AND SHALL HAVE SUFFICIENT
 LATERAL-BEARING CAPACITY TO RESIST COLLAPSE. THE CLEAR
 ACCESS OPENING DIMENSIONS SHALL BE A MINIMUM OF 22
 INCHES BY 30 INCHES (559 MM BY 762 MM), AND LARGE
 ENOUGH TO ALLOW REMOVAL OF THE LARGEST APPLIANCE.
 EXCEPTIONS:
 1. THE PASSAGEWAY IS NOT REQUIRED WHERE THE LEVEL
 SERVICE SPACE IS PRESENT WHEN THE ACCESS IS OPEN AND
 THE APPLIANCE IS CAPABLE OF BEING SERVICED AND REMOVED
 THROUGH THE REQUIRED OPENING.
 2. WHERE THE PASSAGEWAY IS UNOBSTRUCTED AND NOT LESS
 THAN 6 FEET HIGH (1929 MM) AND 22 INCHES (559 MM) WIDE
 FOR ITS ENTIRE LENGTH, THE PASSAGEWAY SHALL NOT BE
 LIMITED IN LENGTH.
  
 5) REFER TO SECTION 603 AND PROVIDE AN UNDERFLOOR DUCT
 LAYOUT PLAN. INDICATE THE TYPES AND SIZES OF DUCTS, AND
 DUCT SUPPORT AND CONNECTION DETAILS.
 6) REFER TO SECTION 603.18 AND PROVIDE EVIDENCE OR DATA
 ON THE PLAN VERIFYING COMPLIANCE: REGISTERS, GRILLES
 AND DIFFUSERS.
 DUCT REGISTERS, GRILLES AND DIFFUSERS SHALL BE
 INSTALLED IN ACCORDANCE WITH THE MANUFACTURER?S
 INSTALLATION INSTRUCTIONS. VOLUME DAMPERS OR OTHER
 MEANS OF SUPPLY AIR ADJUSTMENT SHALL BE PROVIDED IN THE
 BRANCH DUCTS OR AT EACH INDIVIDUAL DUCT REGISTER,
 GRILLE OR DIFFUSER. EACH VOLUME DAMPER OR OTHER MEANS
 OF SUPPLY AIR ADJUSTMENT USED IN BALANCING SHALL BE
 PROVIDED WITH ACCESS.
 7) PROVIDE A UL TESTED AND APPROVED THROUGH PENETRATION
 FIRE STOPPING SYSTEM FOR THE REFRIGERANT PIPES
 PENETRATING THE FIRE-RATED STAIRWELL WALLS- REFER TO
 SECTION 714 FBC-14 BUILDING.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2015-09-09 Cont ID  
Sent By gjohnson Date 2015-09-09 Time 13:42 Rev Time 0.00
Received By gjohnson Date 2015-09-09 Time 15:51 Sent To  
Notes
***NONE***