Plan Review Details - Permit 15080937
Plan Review Stops For Permit 15080937
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2015-09-10 Cont ID  
Sent By jwitmer Date 2015-09-10 Time 13:53 Rev Time 0.00
Received By jwitmer Date 2015-09-10 Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2015-09-04 Cont ID  
Sent By jwitmer Date 2015-09-04 Time 11:10 Rev Time 0.00
Received By jwitmer Date 2015-09-04 Time 11:05 Sent To  
Notes
2015-09-04 11:10:51BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15080937
 ADD: 3640 WHITEHALL UNIT # 401
 CONT: SEC CONSTRUCTION & DEV.
 TEL: (561)797-6007
 E-MAIL: [email protected]
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 3RD REVIEW
 DATE: FRI. SEPT. 04/2015
 ACTION: DENIED
  
 THE SUBMITTED TEST REPORT SUPER SAM 125 TESTED TO ASTM
 E2179 IS NOT A TEST THE CODE RECONIZES, THE (3) TEST
 LISTED BELOW AND ASSOCIATED ASTM NUMBERS ARE THE TEST
 THAT THE FLOOR INSULATION UNDERLAYMENT MUST MEET.
  
  
 BLDG TYPE: TYPE I/ TYPE II FLOOR INSULATION (FBC-B
 2014)
  
 1A) FBC-B 2014 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
 1B) FBC-B 2014 1207.2 AIR-BORNE SOUND.
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
  
 2) TYPE I / II CONSTRUCTION:
 FLAME SPREAD- FBC-B 2014 603.1. EXCEPTION 2. INSULATION
 INSTALLED BETWEEN A FINISHED FLOOR AND SOLID DECKING
 WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED TO HAVE A
 FLAME SPREAD INDEX OF NOT MORE THAN 200.
  
 FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS
 A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL
 MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A
 MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2015-08-31 Cont ID  
Sent By jwitmer Date 2015-08-31 Time 14:28 Rev Time 0.00
Received By jwitmer Date 2015-08-31 Time 14:28 Sent To  
Notes
2015-08-31 14:33:54BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15080937
 ADD: 3640 WHITEHALL UNIT # 401
 CONT: SEC CONSTRUCTION & DEV.
 TEL: (561)797-6007
 E-MAIL: [email protected]
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: MON. AUGUST 31/2015
 ACTION: DENIED
  
 SUBMIT THE ACTUAL TEST. SAM 90 HAS NOT PASSED THE SOUND
 TEST LISTED BELOW WITHOUT A DROPPED CEILING. ALL
 TESTING TO DATE HAS A DROPPED CEILING. SAM 90 DOES MEET
 THE FLAME SPREAD REQUIREMENTS BUT NOT THE ASTM E492 FOR
 STURTURE BORNE SOUND NOR ASTM E90 FOR AIR BORNE SOUND.
  
 BLDG TYPE: TYPE I/ TYPE II FLOOR INSULATION (FBC-B
 2014)
  
 1A) FBC-B 2014 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
 1B) FBC-B 2014 1207.2 AIR-BORNE SOUND.
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
  
 2) TYPE I / II CONSTRUCTION:
 FLAME SPREAD- FBC-B 2014 603.1. EXCEPTION 2. INSULATION
 INSTALLED BETWEEN A FINISHED FLOOR AND SOLID DECKING
 WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED TO HAVE A
 FLAME SPREAD INDEX OF NOT MORE THAN 200.
  
 FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS
 A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL
 MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A
 MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-08-27 Cont ID  
Sent By jwitmer Date 2015-08-27 Time 06:29 Rev Time 0.00
Received By jwitmer Date 2015-08-27 Time 06:00 Sent To  
Notes
2015-08-27 06:29:54BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15080937
 ADD: 3640 WHITEHALL UNIT # 401
 CONT: SEC CONSTRUCTION & DEV.
 TEL: (561)797-6007
 E-MAIL: [email protected]
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: THURS. AUGUST 27/2015
 ACTION: DENIED
  
 THE MINIMUM BUILDING TYPE IS NOT IDENTIFIED, IF FIRE
 SPRINKLERED WITH NFPA 13 OR 13R NOR IS HOW MANY STORIES
 I THE BUILDING IS IN HEIGHT.
 THESE ARE ALL FACTORS IN THIS REVIEW
 BLDG TYPE: TYPE I/ TYPE II FLOOR INSULATION (FBC-B
 2014)
  
 1A) FBC-B 2014 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
 1B) FBC-B 2014 1207.2 AIR-BORNE SOUND.
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
  
 2) TYPE I / II CONSTRUCTION:
 FLAME SPREAD- FBC-B 2014 603.1. EXCEPTION 2. INSULATION
 INSTALLED BETWEEN A FINISHED FLOOR AND SOLID DECKING
 WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED TO HAVE A
 FLAME SPREAD INDEX OF NOT MORE THAN 200.
 OR
 TYPE III-TYPE V CONSTRUCTION:
 FBC-B-2014 719.2 CONCEALED INSTALLATION.
 INSULATING MATERIALS, WHERE CONCEALED AS INSTALLED IN
 BUILDINGS OF ANY TYPE OF CONSTRUCTION, SHALL HAVE A
 FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A
 SMOKE-DEVELOPED INDEX OF NOT MORE THAN 450.
  
 FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS
 A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL
 MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A
 MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2015-09-10 Cont ID  
Sent By jwitmer Date 2015-09-10 Time 13:53 Rev Time 0.00
Received By jwitmer Date 2015-09-08 Time 09:25 Sent To  
Notes
2015-09-09 09:26:07RESUB ROUTED TO JWITMER

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2015-09-04 Cont ID  
Sent By jwitmer Date 2015-09-04 Time 11:11 Rev Time 0.00
Received By jwitmer Date 2015-09-01 Time 15:16 Sent To  
Notes
2015-09-01 15:16:49RESUB ROUTED TO JWITMER

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-08-31 Cont ID  
Sent By jwitmer Date 2015-08-31 Time 14:28 Rev Time 0.00
Received By jwitmer Date 2015-08-28 Time 14:59 Sent To  
Notes
2015-08-28 14:59:47RESUB ROUTED TO JWITMER

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-08-27 Cont ID  
Sent By jwitmer Date 2015-08-27 Time 06:30 Rev Time 0.00
Received By jwitmer Date 2015-08-25 Time 15:39 Sent To  
Notes
2015-08-25 15:39:42ROUTED TO PLUMBING INBOX

Review Stop P PLUMBING
Rev No 1 Status P Date 2015-08-26 Cont ID  
Sent By tklarge Date 2015-08-26 Time 10:11 Rev Time 0.00
Received By tklarge Date 2015-08-26 Time 10:11 Sent To  
Notes
***NONE***