| 2015-08-27 10:47:22 | BUILDING PLAN REVIEW |
| | W. P. B. REVISION: 15080905 |
| | W. P. B. PERMIT: 15070711 |
| | ADD: 4912 S. DIXIE HWY |
| | CONT: LEIGHTON & MCGINN |
| | TEL: (561)951-0376 |
| | E-MAIL: ???????????? |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: THURS. AUGUST 27/ 2015 |
| | ACTION: DENIED |
| | |
| | 1) THE PLANS NOTE # 23 INDICATE THE REMOVAL OF THE |
| | FINISH ROOF, ROOF DECK INCLUDING THE STRUCTURAL FRAMING |
| | MEMBERS. THE PLANS DO NOT INDICATE HOW THE REMAINING |
| | EXTERIOR EXTERIOR WALLS ARE TO BE BRACED TO STAND |
| | AGAINST HURRICANE STRENGTH WINDS OF 170 VULT. 2014 |
| | FBC-EXISTING BUILDING CODE 807.6 A DANGEROUS CONDITION |
| | AS DEFINED IN THIS CODE IN THIS CODE IS NOT CREATED. |
| | |
| | 2) CURRENTLY THERE ARE NO PLANS SUBMITTED FOR THE |
| | INSTALATION OF A NEW ROOF SYSTEM SUBMITTED TO THE |
| | BUILDING DEPARTMENT. THE PLANS ALSO DO NOT INDICATE HOW |
| | THE INTERIOR WALLS ARE GOING TO BE PROTECTED FROM THE |
| | ELEMENTS? 2014 FBC-EXISTING BUILDING CODE 807.6 A |
| | DANGEROUS CONDITION AS DEFINED IN THIS CODE IN THIS |
| | CODE IS NOT CREATED. |
| | |
| | 3) NOTE # 17 INDICATES THE REMOVAL OF A CONCRETE |
| | CANOPY/ AWNING. THIS MAY BE OVER THE PROPERTY LINE |
| | REQUIRING A ENGINEERING REVIEW. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | |
| | |
| | |
| | |