| Plan Review Stops For Permit 15080889 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2015-10-20 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-10-20 |
Time |
13:34 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-10-20 |
Time |
10:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-10-05 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-10-05 |
Time |
11:40 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-10-03 |
Time |
09:12 |
Sent To |
|
|
| Notes |
| 2015-10-05 11:40:04 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE ENERGY COMPLIANCE FORM IS REQUIRED TO BE SIGNED | | | AND DATED BY THE OWNER/AGENT. FBC ENERGY CONSERVATION - | | | SECT. R103.1.1.2 CODE COMPLIANCE CERTIFICATION. | | | | | | 2) FBC 107.3.4 - THE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY DCA RULE 9N-3 ARE | | | REQUIRED TO BE REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD. | | | | | | 3) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS | | | FOR THE STRUCTURAL WINDOW MULLIONS AS REQUIRED BY DCA | | | RULE 9N-3 THAT HAVE BEEN REVIEWED AND APPROVED IN | | | WRITING BY THE DESIGNER OF RECORD. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2015-10-20 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-10-20 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-10-20 |
Time |
10:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2015-10-05 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-10-05 |
Time |
11:25 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-10-05 |
Time |
09:05 |
Sent To |
|
|
| Notes |
| 2015-10-05 11:06:36 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) / 2011 NEC | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY ELECTRICAL | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) NEC 240.24(A) - (F) PANELS SHALL BE READILY | | | ACCESSIBLE. SPECIFY THE LOCATION OF THE PANEL ON THE | | | ELECTRICAL FLOOR PLAN. | | | | | | 2) NEC 110.26 SUFFICIENT ACCESS AND WORKING SPACE SHALL | | | BE PROVIDED AND MAINTAINED ABOUT ALL ELECTRICAL | | | EQUIPMENT TO PERMIT READY AND SAFE OPERATION AND | | | MAINTENANCE OF SUCH EQUIPMENT. SPECIFY THE LOCATION OF | | | THE SERVICE (METER) ON THE ELECTRICAL FLOOR PLAN. | | | | | | 3) NEC 440.11 & 440.14 SHOW THE LOCATION OF THE | | | REQUIRED A/C EQUIPMENT DISCONNECTING MEANS ON THE | | | PLANS. | | | | | | 4) NEC 210.11 (C) (3) AT LEAST ONE 20 - AMP BRANCH | | | CIRCUIT SHALL BE PROVIDED TO SUPPLY BATHROOM RECEPTACLE | | | OUTLETS. | | | | | | 5) THE ELECTRICAL DESIGN CODE NOTE INCORRECTLY | | | REFERENCES THE 2008 NEC. THE FIFTH EDITION 2014 FBC | | | REFERENCES THE 2011 NEC. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-10-20 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-10-20 |
Time |
13:35 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-10-09 |
Time |
13:32 |
Sent To |
|
|
| Notes |
| 2015-10-09 13:32:38 | RMCDOUGAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-10-05 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-10-05 |
Time |
11:40 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-08-24 |
Time |
08:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2015-10-20 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-10-20 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-10-20 |
Time |
10:34 |
Sent To |
|
|
| Notes |
| 2015-10-20 10:40:40 | MU2015-23915, PAID $180.65 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2015-10-03 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-10-03 |
Time |
09:12 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-10-03 |
Time |
09:12 |
Sent To |
|
|
| Notes |
| 2015-10-03 09:13:32 | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES | | | MUST BE PAID TO PALM BEACH COUNTY. UPON CITY APPROVAL, | | | ONE SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO | | | PALM BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS | | | WITH THE IMPACT FEE STAMP AND A COPY OF THE PAID | | | RECEIPT MUST BE RETURNED TO THE CITY BUILDING | | | DEPARTMENT BEFORE THE BUILDING PERMIT CAN BE ISSUED. | | | FOR INFORMATION CALL PALM BEACH COUNTY IMPACT FEES AT | | | (561) 233-5025. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2015-10-20 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-10-20 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-10-20 |
Time |
10:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2015-10-05 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-10-05 |
Time |
10:07 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-10-05 |
Time |
09:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2015-09-01 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-09-01 |
Time |
03:53 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-09-01 |
Time |
03:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2015-09-02 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2015-09-02 |
Time |
07:52 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
2015-09-02 |
Time |
07:52 |
Sent To |
|
|
| Notes |
| 2015-08-31 11:15:24 | 8/31/15 |
|
|