| Plan Review Stops For Permit 15080832 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2016-02-25 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-02-25 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-02-25 |
Time |
13:54 |
Sent To |
|
|
| Notes |
| 2016-02-25 14:01:40 | RESIDENTIAL (R3) ADDITION/ALTERATION, THIRD BUILDING | | | REVIEW CHECKLIST. | | | CODE: FBC-5TH EDITION (2014). | | | | | | 1- FOOTPRINT SIZE OF THE GARAGE SHOWN ON SURVEY AND | | | PLANS SUBMITTED DON'T MATCH THE FOOTPRINT OF THE CITY | | | RECORDS AND THE PROPERTY APPRAISER RECORDS. THE | | | ORIGINAL FOOTPRINT SHOWN ON CITY RECORDS AND PROPERTY | | | APPRAISER SHOW A GARAGE FOOTPRINT OF 12'-0" BY 20'-0". | | | SURVEY AND PLANS SHOW A BUILDING DOUBLE THE SIZE. THERE | | | ARE NO PERMITS FOR THE ENLARGEMENT OF THE GARAGE. | | | REVISE PLANS AND SURVEY AS REQUIRED AS REQUIRED. | | | CLEARLY IDENTIFY WHAT'S EXISTING AND WHAT'S NEW. . SEC. | | | 107.2.1 CITY AMENDMENTS. | | | NOTE: OLD PLANS SUBMITTED ON PREVIOUS REVIEWS SHOW THE | | | CORRECT SIZE OF THE GARAGE. | | | | | | 2- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | FAC 61G20-3.002(33) FOR: | | | A) EXTERIOR DOOR. PROVIDE THE FLORIDA PRODUCT APPROVAL | | | COVER PAGE THAT CORRESPONDS TO DOOR DRAWINGS SUBMITTED. | | | NOTE: NEED FLORIDA PRODUCT APPROVAL COVER PAGE FOR 2014 | | | CODE. (NOTE: IF THERE IS NOT CURRENT FLORIDA PRODUCT | | | APPROVAL, THEN THE MANUFACTURER MAY APPLY FOR LOCAL | | | PRODUCT APPROVAL. COMPLETE SIGNED AND SEALED PRODUCT | | | APPROVAL PACKAGE WILL NEED TO BE SUBMITTED FOR BUILDING | | | OFFICIAL APPROVAL). | | | RESPONSE: PRODUCT APPROVAL INFORMATION SUBMITTED | | | DOESN'T HAVE A FLORIDA PRODUCT APPROVAL COVER PAGE OR | | | FLORIDA PRODUCT APPROVAL NUMBER THAT CORRESPONDS TO | | | DRAWINGS SUBMITTED. | | | | | | B) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON ALL | | | DETAILS. PROVIDE FLORIDA PRODUCT APPROVAL COVER PAGE | | | AND PAGE SHOWING THE SPECIFIED CONNECTOR OR ENGINEER TO | | | LIST THE 2014 FLORIDA PRODUCT APPROVAL NUMBER NEXT TO | | | EACH SPECIFIED CONNECTOR. | | | RESPONSE: (REPEAT COMMENT). FLORIDA PRODUCT APPROVAL | | | #10865 SHOWN ON WALL SECTION "A" DOESN'T SHOW THE | | | SPECIFIED CONNECTORS. REVISE AS REQUIRED. CLEARLY | | | SPECIFY FLORIDA PRODUCT APPROVAL NUMBER FOR EACH | | | CONNECTOR SPECIFIED ON THE WALL SECTION "A" , INCLUDING | | | THE SIMPSON 5P2 . | | | | | | 3- ENGINEER OF RECORD TO APPROVE IN WRITING ALL PRODUCT | | | APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY | | | AMENDMENTS. | | | | | | 4- GENERAL NOTE # 15 OF SURVEY SUBMITTED STATES THAT | | | THIS SURVEY CAN NOT BE USED FOR CONSTRUCTION OR | | | PERMITTING PURPOSES WITHOUT WRITTEN CONSENT FROM MIGUEL | | | ESPINOZA. PROVIDE SURVEY WITH SURVEYOR'S ORIGINAL SEAL | | | AND SIGNATURE THAT CAN BE USED FOR PERMITTING AND | | | CONSTRUCTION. CHAPTER 472 FLORIDA STATUTE. | | | | | | *** PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | | COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2015-12-07 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-12-07 |
Time |
17:46 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-12-07 |
Time |
17:46 |
Sent To |
E |
|
| Notes |
| 2015-12-07 17:46:59 | RESIDENTIAL (R3) ADDITION/ALTERATION, SECOND BUILDING | | | REVIEW CHECKLIST. | | | CODE: FBC-5TH EDITION (2014). | | | | | | NOTE: | | | SEE ZONING COMMENTS REGARDING BUILDING SETBACKS. IN | | | ADDITION, SEE COMMENTS BELOW. | | | | | | 1- BASED ON SURVEY SUBMITTED, THE ADDITION IS LOCATED | | | LESS THAN 3'-0" FROM THE PROPERTY LINE. NEED TO COMPLY | | | WITH THE FOLLOWING: | | | A) NO OPENINGS ALLOWED. SEC. R302.1 AND TABLE R302.1(1) | | | OF FBC-RESIDENTIAL, 5TH EDITION (2014). | | | | | | B) NEED TO SPECIFY 1 HR FIRE RATED EXTERIOR WALL | | | ASSEMBLY. SPECIFY PUBLISHED ASSEMBLY NUMBER. ASSEMBLY | | | SPECIFIED TO BE TESTED IN ACCORDANCE WITH ASTM E 119 OR | | | UL 263 WITH EXPOSURE ON BOTH SIDES. SEC. R302.1 AND | | | TABLE R302.1(1) OF FBC-RESIDENTIAL, 5TH EDITION (2014). | | | | | | C) SPECIFY 1 HR FIRE RATED ASSEMBLY FOR THE UNDERSIDE | | | OF THE ROOF PROJECTION AS REQUIRED BY SEC. R302.1 AND | | | TABLE R302.1(1) OF FBC-RESIDENTIAL, 5TH EDITION (2014). | | | | | | D) WALL PENETRATIONS NEED TO COMPLY WITH SEC. R302.1 | | | AND TABLE R302.1(1) OF FBC-RESIDENTIAL, 5TH EDITION | | | (2014). | | | | | | 2- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | FAC 61G20-3.002(33) FOR: | | | A) EXTERIOR DOOR. PROVIDE THE FLORIDA PRODUCT APPROVAL | | | COVER PAGE THAT CORRESPONDS TO DOOR DRAWINGS SUBMITTED. | | | NOTE: NEED FLORIDA PRODUCT APPROVAL COVER PAGE FOR 2014 | | | CODE. | | | RESPONSE: PRODUCT APPROVAL INFORMATION SUBMITTED | | | DOESN'T HAVE A FLORIDA PRODUCT APPROVAL COVER PAGE OR | | | FLORIDA PRODUCT APPROVAL NUMBER THAT CORRESPONDS TO | | | DRAWINGS SUBMITTED. AND, DRAWINGS SUBMITTED DON'T MATCH | | | TYPE OF DOOR SHOWN ON PLANS. | | | | | | B) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON ALL | | | DETAILS. PROVIDE FLORIDA PRODUCT APPROVAL COVER PAGE | | | AND PAGE SHOWING THE SPECIFIED CONNECTOR OR ENGINEER TO | | | LIST THE 2014 FLORIDA PRODUCT APPROVAL NUMBER NEXT TO | | | EACH SPECIFIED CONNECTOR. | | | RESPONSE: CLEARLY SPECIFY FLORIDA PRODUCT APPROVAL | | | NUMBER FOR EACH CONNECTOR SPECIFIED ON THE WALL SECTION | | | "A" , INCLUDING THE SIMPSON 5P2 . ALSO, THERE ARE OTHER | | | CONNECTORS LIKE THE SIMPSON HTU28 THAT ARE NOT COVERED | | | UNDER THE FLORIDA PRODUCT APPROVAL FL10865. REVISE AS | | | REQUIRED. | | | | | | 3- ENGINEER OF RECORD TO APPROVE IN WRITING ALL PRODUCT | | | APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY | | | AMENDMENTS. | | | RESPONSE: DOOR PRODUCT APPROVAL APPROVED BY THE | | | ENGINEER DOESN'T MATCH PLANS. | | | | | | 4- THERE ARE TWO DIFFERENT SURVEYS SUBMITTED. PLANS AND | | | SURVEY SUBMITTED DON'T MATCH. REVISE AS REQUIRED. | | | PROVIDE CLEAR DRAWINGS SHOWN WHAT'S EXISTING AND WHAT'S | | | PROPOSED. SEC. 107.2.1 CITY AMENDMENTS. | | | | | | *** PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | | COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-10-02 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-10-02 |
Time |
17:20 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-10-02 |
Time |
15:33 |
Sent To |
E |
|
| Notes |
| 2015-10-02 17:29:10 | RESIDENTIAL (R3) ADDITION/ALTERATION, BUILDING REVIEW | | | COMMENTS. | | | CODE: FBC-5TH EDITION (2014). | | | | | | 1- PROVIDE SITE PLAN OR SURVEY WITH COMPLETE DIMENSIONS | | | SHOWING LOCATION OF NEW ADDITION AND EXISTING HOUSE. | | | SEC. 107.3.5.3(1). CITY AMENDMENTS. | | | | | | 2- IDENTIFY THE NAME OF THE ROOM OF PROPOSED ADDITION. | | | WHAT'S THE ROOM GOING TO BE USED FOR?. NEED TO IDENTIFY | | | ROOM FOR PROPER PLAN REVIEW. IS THIS ROOM GOING TO BE | | | USED FOR LIVING PURPOSES?. CLARIFY WHY THERE IS NOT A | | | DOOR BETWEEN THE STORAGE ROOM AND THE NEW ADDITION. | | | CLARIFY WHY IS THERE A BATHROOM IN THE NEW ROOM | | | ADJACENT TO THE STORAGE ROOM. SEC. 107.2.1 CITY | | | AMENDMENTS. | | | | | | 3- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | | LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS, | | | CONTRACTOR'S OVERHEAD AND PROFIT AND ALL DESIGN | | | PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY | | | AMENDMENTS. VALUATION WAS UPDATED TO $15,000. THE | | | PERMIT FEE BALANCE IS $1453.60. | | | | | | 4- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH | | | COUNTY (2300 N. JOG RD.) FOR IMPACT FEES ASSESSMENT. | | | THEN, BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID | | | RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF | | | THE UNIFIED LAND DEVELOPMENT CODE. | | | | | | 5- SPECIFY THE ROOF PITCH OF THE NEW ADDITION TO VERIFY | | | COMPLIANCE WITH SHINGLES INSTALLATION ON THE PROPOSED | | | SLOPE. SEC. R905.2.2 OF FBC-RESIDENTIAL , 5TH EDITION | | | (2014). | | | | | | 6- LETTERING ON THE "TYP. HEADERS IN DR. & WINDOW | | | FRAMING" DETAIL ON SHEET 2 OF 2 IS TO SMALL AND IS NOT | | | LEGIBLE. REVISE AS REQUIRED. PROVIDE BIGGER AND CLEAR | | | LETTERING. SEC. 107.2.1.4 CITY AMENDMENTS. | | | | | | 7- WALL SECTION "A" ON SHEET 2 OF 2: | | | A) SPECIFY ROOF CROSS VENTILATION AS REQUIRED BY SEC. | | | R806 OF FBC-RESIDENTIAL , 5TH EDITION (2014). | | | | | | B) SPECIFY FOOTING SIZE. SEC. R301 OF FBC-RESIDENTIAL , | | | 5TH EDITION (2014). | | | NOTE: COORDINATE WITH ITEM #7(C) AND #7(D) BELOW. | | | | | | C) SPECIFY THE 6" CLEARANCE FROM GRADE TO FINISH FLOOR | | | AS REQUIRED BY SEC. R404.1.6 OF FBC-RESIDENTIAL , 5TH | | | EDITION (2014). | | | | | | D) SPECIFY FOOTING TO BE 12" BELOW FINISHED GRADE AS | | | REQUIRED BY SEC. R403.1.4 OF FBC-RESIDENTIAL , 5TH | | | EDITION (2014). | | | | | | E) LENGTH OF RED HEAD ANCHOR SPECIFIED TO CONNECT THE | | | BOTTOM PLATE TO THE CONCRETE SLAB IS NOT CLEAR. REVISE | | | AS REQUIRED. SEC. 107.2.1.4 CITY AMENDMENTS. | | | | | | F) SPECIFY STUCCO THICKNESS AS REQUIRED BY TABLE | | | R702.1(1) OF FBC-RESIDENTIAL , 5TH EDITION (2014). | | | | | | 8-PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | FAC 61G20-3.002(33) FOR: | | | A) EXTERIOR DOOR. PROVIDE THE FLORIDA PRODUCT APPROVAL | | | COVER PAGE THAT CORRESPONDS TO DOOR DRAWINGS SUBMITTED. | | | NOTE: NEED FLORIDA PRODUCT APPROVAL COVER PAGE FOR 2014 | | | CODE. | | | | | | B) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON ALL | | | DETAILS. PROVIDE FLORIDA PRODUCT APPROVAL COVER PAGE | | | AND PAGE SHOWING THE SPECIFIED CONNECTOR OR ENGINEER TO | | | LIST THE 2014 FLORIDA PRODUCT APPROVAL NUMBER NEXT TO | | | EACH SPECIFIED CONNECTOR. | | | | | | 9- ENGINEER OF RECORD TO APPROVE IN WRITING ALL PRODUCT | | | APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY | | | AMENDMENTS. | | | | | | *** PLEASE PROVIDE ENGINEER RESPONSE LETTER ADDRESSING | | | EACH COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2016-03-09 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-03-09 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-03-09 |
Time |
10:34 |
Sent To |
|
|
| Notes |
| 2016-03-09 10:38:47 | REVIEW 2014 5TH FBC ED. NEC 2011 | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 516-805-6713 | | | [email protected] | | | | | | | | | - NEC 210.8 A2 ALL GARAGES AND BATHROOMS OUTLETS SHALL | | | BE GFCI PROTECTED. | | | | | | - NEC 212.52 SINCE CONVERTING GARAGE TO LIVABLE SPACE | | | RECEPTACLES MUST SPACED 6FT IN BETWEEN EACH OTHER ON | | | THE FLOOR PLANS. FURTHER MORE ANY SPACE 2FT OR MORE | | | UNBROKEN BY OPENINGS SHALL HAVE A RECEPTACLE ON FLOOR | | | PLANS. | | | | | | - NEC 210.70 2B A LIGHT IS REQUIRED OUTSIDE EVERY DOOR | | | FOR SECURITY ILLUMINATION PURPOSES. | | | | | | PLEASE ADDRESS THESE COMMENTS ACCORDINGLY TO AVOID A 4X | | | THE REVIEW FEE PENALTY. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2015-12-10 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-12-10 |
Time |
13:19 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2015-12-10 |
Time |
12:59 |
Sent To |
|
|
| Notes |
| 2015-12-10 13:29:58 | 1ST REVIEW: FBC 2014 5TH ED. NEC 2011/RESIDENTIAL | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 516-805-6700 | | | [email protected] | | | ALTERNATE CONTACT | | | PHIL PETTY | | | 561-805-6742 | | | [email protected] | | | | | | | | | (A) DWELLING UNITS. ALL 125-VOLT, SINGLE-PHASE, 15- AND | | | 20- | | | AMPERE RECEPTACLES INSTALLED IN THE LOCATIONS SPECIFIED | | | IN | | | 210.8(A)(1) THROUGH (8) SHALL HAVE GROUND-FAULT | | | CIRCUITINTERRUPTER | | | PROTECTION FOR PERSONNEL. | | | (1) BATHROOMS | | | (2) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT HAVE A | | | FLOOR | | | LOCATED AT OR BELOW GRADE LEVEL NOT INTENDED AS | | | HABITABLE | | | ROOMS AND LIMITED TO STORAGE AREAS, WORK AREAS, | | | AND AREAS OF SIMILAR USE | | | | | | (A) GENERAL PROVISIONS. IN EVERY KITCHEN, FAMILY ROOM, | | | DINING ROOM, LIVING ROOM, PARLOR, LIBRARY, DEN, | | | SUNROOM, | | | BEDROOM, RECREATION ROOM, OR SIMILAR ROOM OR AREA OF | | | DWELLING UNITS, RECEPTACLE OUTLETS SHALL BE INSTALLED | | | IN ACCORDANCE | | | WITH THE GENERAL PROVISIONS SPECIFIED IN 210.52(A)(1) | | | THROUGH (A)(3). | | | (1) SPACING. RECEPTACLES SHALL BE INSTALLED SUCH THAT | | | NO | | | POINT MEASURED HORIZONTALLY ALONG THE FLOOR LINE OF ANY | | | WALL | | | SPACE IS MORE THAN 1.8 M (6 FT) FROM A RECEPTACLE | | | OUTLET. | | | (2) WALL SPACE. AS USED IN THIS SECTION, A WALL SPACE | | | SHALL | | | INCLUDE THE FOLLOWING: | | | (1) ANY SPACE 600 MM (2 FT) OR MORE IN WIDTH (INCLUDING | | | SPACE MEASURED AROUND CORNERS) AND UNBROKEN ALONG | | | THE FLOOR LINE BY DOORWAYS AND SIMILAR OPENINGS, | | | FIREPLACES, | | | AND FIXED CABINETS | | | (2) THE SPACE OCCUPIED BY FIXED PANELS IN EXTERIOR | | | WALLS, | | | EXCLUDING SLIDING PANELS | | | (3) THE SPACE AFFORDED BY FIXED ROOM DIVIDERS, SUCH AS | | | FREESTANDING BAR-TYPE COUNTERS OR RAILINGS | | | | | | FOR DWELLING UNITS, ATTACHED GARAGES, AND DETACHED | | | GARAGES WITH ELECTRIC POWER, AT LEAST ONE WALL SWITCH? | | | CONTROLLED LIGHTING OUTLET SHALL BE INSTALLED TO | | | PROVIDE ILLUMINATION | | | ON THE EXTERIOR SIDE OF OUTDOOR ENTRANCES OR EXITS | | | WITH GRADE LEVEL ACCESS. A VEHICLE DOOR IN A GARAGE | | | SHALL NOT | | | BE CONSIDERED AS AN OUTDOOR ENTRANCE OR EXIT | | | | | | | | 2015-12-07 18:42:41 | NEW PLANS SUBMITTED. JG. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2015-10-05 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2015-10-05 |
Time |
11:27 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2015-10-05 |
Time |
11:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2016-03-09 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-03-09 |
Time |
11:04 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-02-16 |
Time |
13:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-12-10 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2015-12-10 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2015-11-18 |
Time |
12:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-10-05 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2015-10-05 |
Time |
11:27 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2015-08-21 |
Time |
16:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
F |
Date |
2016-02-25 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-02-25 |
Time |
18:57 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-02-25 |
Time |
18:56 |
Sent To |
|
|
| Notes |
| 2016-02-25 18:57:41 | 1- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD.) | | | FOR IMPACT FEES ASSESSMENT. THEN, BRING BACK COUNTY | | | STAMPED PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE. | | | COUNTY IMPACT FEE ORDINANCE OF THE UNIFIED LAND | | | DEVELOPMENT CODE. | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2015-12-07 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-12-07 |
Time |
18:41 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-12-07 |
Time |
18:41 |
Sent To |
|
|
| Notes |
| 2015-12-07 18:42:11 | 1- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH | | | COUNTY (2300 N. JOG RD.) FOR IMPACT FEES ASSESSMENT. | | | THEN, BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID | | | RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF | | | THE UNIFIED LAND DEVELOPMENT CODE. | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2015-10-02 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-10-02 |
Time |
18:14 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-10-02 |
Time |
18:14 |
Sent To |
|
|
| Notes |
| 2015-10-02 18:14:50 | 1- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH | | | COUNTY (2300 N. JOG RD.) FOR IMPACT FEES ASSESSMENT. | | | THEN, BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID | | | RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF | | | THE UNIFIED LAND DEVELOPMENT CODE. | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2016-02-24 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-02-24 |
Time |
16:12 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-02-24 |
Time |
16:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2015-11-23 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-11-23 |
Time |
05:03 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-11-23 |
Time |
04:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2015-09-01 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-09-01 |
Time |
04:07 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-09-01 |
Time |
03:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2016-02-25 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-02-25 |
Time |
18:57 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-02-25 |
Time |
18:57 |
Sent To |
|
|
| Notes |
| 2016-02-25 18:58:39 | SHINGLES NOA 14-1022.16 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2015-10-05 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-10-05 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-10-05 |
Time |
11:07 |
Sent To |
|
|
| Notes |
| 2015-10-05 11:07:56 | SHINGLES NOA 12-1127.03. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2016-03-07 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2016-03-07 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2016-03-07 |
Time |
13:30 |
Sent To |
E |
|
| Notes |
| 2016-03-07 13:31:54 | 3/7/16- FAILED SEE BUILDING COMMENT #1 | | | ANGELLA VANN, AICP | | | 561-822-1441 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2015-12-04 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2015-12-04 |
Time |
16:13 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2015-12-04 16:16:01 | 12/3/15 ZONING FAILED | | | | | | 1. THE ADDITION MUST 5' FEET FROM THE REAR PROPERTY AND | | | SIDE PROPERTY. | | | 2. THE ADDITION MUST BE USED ONLY AS STORAGE AND | | | EXERCISE ROOM ONLY, ROOM CAN NOT BE USED AS A SLEEPING | | | AREA. | | | 3. THE SITE PLAN AND THE PLANS DO NOT MATCH, SUBMIT | | | PLANS THE MATCH. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2015-08-25 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2015-08-25 |
Time |
08:29 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
2015-08-25 |
Time |
08:29 |
Sent To |
|
|
| Notes |
| 2015-08-25 08:30:43 | 8/25/15 ZONING FAILED | | | | | | 1. SUBMIT TWO COPIES OF UP TO DATE SURVEYS SHOWING | | | LOCATION OF THE ADDITION. | | 2015-08-24 11:11:39 | 8/24/15 |
|
|