Plan Review Details - Permit 15080695
| Plan Review Stops For Permit 15080695 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2015-09-28 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-09-28 |
Time |
07:33 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-09-28 |
Time |
07:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2015-09-25 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-09-25 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-09-25 |
Time |
09:35 |
Sent To |
|
|
| Notes |
| 2015-09-25 11:58:20 | 2ND REVIEW: FBC 2014 5TH ED. | | | | | | THE RE-SUBMITTED TEST ARE FOR A CONDITION THAT MAY NOT | | | EXIST IN THE PROPOSED LOCATION. SHOW THAT THE EXISTING | | | CONDITION IS THE SAME AS DESCRIBED IN THE SOUND TESTS, | | | OR PROVIDE A PRODUCT WITH TESTING CONDITIONS EQUIVALENT | | | TO THE PROPOSED INSTALLATION. | | | | | | PLEASE SUBMIT PRODUCT TEST REPORTS TO DEMONSTRATE | | | COMPLIANCE WITH THE FOLLOWING: | | | | | | FBC 603.1 FLAME SPREAD | | | | | | FBC 1207.2 AIR-BORNE SOUND. | | | WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES | | | SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM | | | PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION | | | CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) | | | FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM | | | E 90. | | | | | | 1207.3 STRUCTURE-BORNE SOUND. | | | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR | | | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. | | | | | | FOR YOU CONVENIENCE, YOU MAY E-MAIL REPORTS TO ME. | | | | | | STEVEN KENNEDY, CBO | | | CHIEF PLANS EXAMINER | | | (561) 805-6710 | | | [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-09-09 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-09-09 |
Time |
16:10 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-09-09 |
Time |
16:10 |
Sent To |
|
|
| Notes |
| 2015-09-09 16:14:18 | 1ST REVIEW: FBC 2014 5TH ED. | | | | | | PLEASE SUBMIT PRODUCT TEST REPORTS TO DEMONSTRATE | | | COMPLIANCE WITH THE FOLLOWING: | | | | | | FBC 603.1 FLAME SPREAD | | | | | | FBC 1207.2 AIR-BORNE SOUND. | | | WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES | | | SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM | | | PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION | | | CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) | | | FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM | | | E 90. | | | | | | 1207.3 STRUCTURE-BORNE SOUND. | | | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR | | | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. | | | | | | FOR YOU CONVENIENCE, YOU MAY E-MAIL REPORTS TO ME. | | | | | | STEVEN KENNEDY, CBO | | | CHIEF PLANS EXAMINER | | | (561) 805-6710 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-09-25 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-09-25 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-09-23 |
Time |
10:01 |
Sent To |
|
|
| Notes |
| 2015-09-24 10:01:57 | ROUTED TO SKENNEDY |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-09-09 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-09-09 |
Time |
16:10 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-08-19 |
Time |
14:22 |
Sent To |
|
|
| Notes |
| 2015-08-19 14:23:02 | BLDG MISC 1 |
|
|
|