Plan Review Details - Permit 15080547
| Plan Review Stops For Permit 15080547 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2015-09-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-09-26 |
Time |
10:14 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-09-26 |
Time |
09:17 |
Sent To |
|
|
| Notes |
| 2015-09-26 09:24:18 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 15080547 | | | ADD: 550 S. ROSEMARY AVE. #160 | | | CONT: DC GREEN, LLC | | | TEL: (772)919-1412 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W * 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION, | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: SAT. SEPT. 26/2015 | | | ACTION: PROVISO/ RED LINED | | | | | | 1A) S HEET A130.1 EXTERIOR WALLS SHOW A WALL TAG # 1. | | | WALL IDENTIFICATION TAGS FOUND ON SHEET A020.1 AND | | | REFERENCES DETAILS 3 & 4 SHEET A400.2. PLEASE NOTE | | | THERE ARE 2 ISSUES WITH THIS DETAIL. THE BUILDING IS | | | CLASSIFIED AS A BUILDING TYPE IB WHICH DOES NOT ALLOW | | | EXTERIOR PLYWOOD. PLEASE REVIEW 2014 FBC-B 603.1.1.3. | | | FIRE RETARDANT TREATED WOOD CAN BE USED IN NON-BEARING | | | EXTERIOR WALLS. | | | | | | 1B) DETAILS 3 & 4 ON SHEET A400.2 INDICATE THE USE OF | | | 30 LB. FELT. PLEASE SEE 2014 FBC-B SECTION 2510.6 WHERE | | | APPLIED OVER WOOD-BASED SHEATHING, SHALL INCLUDE A | | | WATER RESISTIVE VAPOR-PERMEABLE BARRIER WITH A | | | PERFORMANCE AT LEAST EQUIVALENT TO TWO LAYERS OF GRADE | | | D PAPER. THE INDIVIDUAL LAYERS SHALL BE INSTALLED | | | INDEPENDENTLY SUCH THAT EACH LAYER PROVIDES A SEPARATE | | | CONTINUOUS PLANE AND ANY FLASHING (INSTALLED IN | | | ACCORDANCE WITH SECTION 1405.4) INTENDED TO DRAIN TO | | | THE WATER-RESISTIVE BARRIER IS DIRECTED BETWEEN THE | | | LAYERS. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2015-09-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-09-23 |
Time |
15:36 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-09-23 |
Time |
12:01 |
Sent To |
|
|
| Notes |
| 2015-09-23 15:36:42 | | | | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 15080547 | | | ADD: 550 S. ROSEMARY AVE. #160 | | | CONT: DC GREEN, LLC | | | TEL: (772)919-1412 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W * 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION, | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: WED. SEPT. 23/2015 | | | ACTION: DENIED | | | | | | 1) COMPLIED. PLANS WERE NOT STAMPED REVIEWED BY CITY | | | PLACE MANAGEMENT THEY WERE REVIEWED AND APPROVED. | | | 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 2) COMPLIED. PERMIT # 15051261 INTERIOR- DEMO. THERE IS | | | NO DEMOLISION PLANS INDICATING WHAT IS BEING DEMOED OR | | | CHANGED, IS EVERYTHING TO BE CONSIDERED NEW? | | | 107.3.5.1.1 MINIMUM PLAN REVIEW CRITERIA FOR COMMERCIAL | | | BUILDINGS. FROM THE LAST KNOWN PERMIT 13010420 THERE IS | | | ALOT OF INTERIOR CHANGES FROM THE LAST KNOWN USE AS FAR | | | AS LAY OUT AND LIFE SAFETY PLAN. A THOROUGH REVIEW | | | CANNOT BE MADE AT THIS TIME, AS A RESULT OF THE | | | ADDITIONAL INFORMATION REQUESTED ADDITIONAL COMMENTS | | | MAY APPEAR THAT WERE NOT PART OF THIS REVIEW. | | | | | | 3) FOR THE AMOUNT OF CHANGES SEEN FROM THE LAST PERMIT | | | (13010420) AND THE PROPOSED LAYOUT THE PERMIT VALUE | | | ASSOCIATED WITH THIS DESIGN IS CONSIDERABLY | | | LOW,EXTREMELY LOW. PERMIT FEES/ PLAN REVIEW: | | | W P B ADMINISTRATIVE CODE 108.2 SCHEDULE OF PERMIT | | | FEES. ON BUILDINGS, STRUCTURES, ELECTRICAL, GAS, | | | MECHANICAL AND PLUMBING SYSTEMS OR ALTERATIONS | | | REQUIRING A PERMIT, A FEE FOR EACH PERMIT SHALL BE PAID | | | AS REQUIRED, IN ACCORDANCE WITH THE SCHEDULE | | | ESTABLISHED BY THE APPLICABLE GOVERNING AUTHORITY. | | | | | | 108.3* BUILDING PERMIT VALUATION. | | | IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE | | | CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE, | | | ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS | | | APPEARS TO BE UNDER ESTIMATED ON THE APPLICATION, THE | | | PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES, | | | VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL | | | REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND | | | SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE | | | STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR | | | FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR | | | BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING | | | COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | | DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES | | | (MARSHALL-SWIFT, MEANS, ETC.) WITH REGIONAL ADJUSTMENTS | | | FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE | | | CONGRESS. | | | | | | 4) 2ND REQUEST. SHEET A120.1THE MENS RESTROOM APPEARS | | | TO HAVE BEEN RENOVATED WITH THE RELOCATION OF THE ENTRY | | | WALL OF THE RESTROOM. THE NEW PLANS SHOW THE SAME | | | ORIGINAL 4 LAVATORIES AND A LONGER COUNTER TOP. NO WALL | | | TAG IDENTIFYING THE WALL TYPE IS PROVIDED ON THE PLANS. | | | 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 5-6) COMPLIED. | | | | | | 6A) 2ND REQUEST. RESPONSE INDICATES AREA TO BE | | | REWORKED. PLEASE NOTE ON SHEET A130.1 EXTERIOR WALLS | | | SHOW A WALL TAG # 1. WALL IDENTIFICATION TAGS FOUND ON | | | SHEET A020.1 AND REFERENCES DETAILS 3 & 4 SHEET A400.2. | | | PLEASE NOTE THERE ARE 2 ISSUES WITH THIS DETAIL. THE | | | BUILDING IS CLASSIFIED AS A BUILDING TYPE IB WHICH DOES | | | NOT ALLOW EXTERIOR PLYWOOD. PLEASE REVIEW 2014 FBC-B | | | 603.1.1.3. FIRE RETARDANT TREATED WOOD CAN BE USED IN | | | NON-BEARING EXTERIOR WALLS. | | | | | | 6B) DETAILS 3 & 4 ON SHEET A400.2 INDICATE THE US OF 30 | | | LB. FELT. PLEASE SEE 2014 FBC-B SECTION 2510.6 WHERE | | | APPLIED OVER WOOD-BASED SHEATHING, SHALL INCLUDE A | | | WATERRESISTIVE VAPOR-PERMEABLE BARRIER WITH A | | | PERFORMANCE AT LEAST EQUIVALENT TO TWO LAYERS OF GRADE | | | D PAPER. THE INDIVIDUAL LAYERS SHALL BE INSTALLED | | | INDEPENDENTLY SUCH THAT EACH LAYER PROVIDES A SEPARATE | | | CONTINUOUS PLANE AND ANY FLASHING (INSTALLED IN | | | ACCORDANCE WITH SECTION 1405.4) INTENDED TO DRAIN TO | | | THE WATER-RESISTIVE BARRIER IS DIRECTED BETWEEN THE | | | LAYERS. | | | | | | 1ST REVIEW COMMENT. PLEASE NOTE SHEET A120.1 THE | | | PROPOSED PLANS SHOW WORK ON THE EAST AND SOUTH OUTSIDE | | | DINING AREA WITH WALLS MOVED, DOORS OPENINGS BEING | | | MODIFIED, A NEW OUTSIDE LOUNGE AREA WALLS REMOVED, THE | | | KITCHEN NEW COOLERS, OLD ONES MOVED BAR LOCATIONS AND | | | WALLS MOVED ETC.... | | | | | | 7) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A | | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | | THIS REVIEW. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2015-08-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-08-26 |
Time |
14:10 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-08-26 |
Time |
06:32 |
Sent To |
|
|
| Notes |
| 2015-08-26 07:21:51 | | | | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 15080547 | | | ADD: 550 S. ROSEMARY AVE. #160 | | | CONT: DC GREEN, LLC | | | TEL: (772)919-1412 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W * 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION, | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: WED. AUGUST 26/2015 | | | ACTION: DENIED | | | | | | 1) PLANS WERE NOT STAMPED REVIEWED BY CITY PLACE | | | MANAGEMENT THEY WERE REVIEWED AND APPROVED. 107.2.1.3 | | | ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 2) THERE IS NO DEMOLISION PLANS INDICATING WHAT IS | | | BEING DEMOED OR CHANGED, IS EVERYTHING TO BE CONSIDERED | | | NEW? 107.3.5.1.1 MINIMUM PLAN REVIEW CRITERIA FOR | | | COMMERCIAL BUILDINGS. FROM THE LAST KNOWN PERMIT | | | 13010420 THERE IS ALOT OF INTERIOR CHANGES FROM THE | | | LAST KNOWN USE AS FAR AS LAY OUT AND LIFE SAFETY PLAN. | | | A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A | | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | | THIS REVIEW. | | | | | | 3) FOR THE AMOUNT OF CHANGES SEEN FROM THE LAST PERMIT | | | (13010420) AND THE PROPOSED LAYOUT THE PERMIT VALUE | | | ASSOCIATED WITH THIS DESIGN IS CONSIDERABLY | | | LOW,EXTREMELY LOW. PERMIT FEES/ PLAN REVIEW: | | | W P B ADMINISTRATIVE CODE 108.2 SCHEDULE OF PERMIT | | | FEES. ON BUILDINGS, STRUCTURES, ELECTRICAL, GAS, | | | MECHANICAL AND PLUMBING SYSTEMS OR ALTERATIONS | | | REQUIRING A PERMIT, A FEE FOR EACH PERMIT SHALL BE PAID | | | AS REQUIRED, IN ACCORDANCE WITH THE SCHEDULE | | | ESTABLISHED BY THE APPLICABLE GOVERNING AUTHORITY. | | | | | | 108.3* BUILDING PERMIT VALUATION. | | | IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE | | | CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE, | | | ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS | | | APPEARS TO BE UNDER ESTIMATED ON THE APPLICATION, THE | | | PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES, | | | VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL | | | REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND | | | SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE | | | STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR | | | FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR | | | BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING | | | COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | | DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES | | | (MARSHALL-SWIFT, MEANS, ETC.) WITH REGIONAL ADJUSTMENTS | | | FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE | | | CONGRESS. | | | | | | 4) SHEET A120.1THE MENS RESTROOM APPEARS TO HAVE BEEN | | | RENOVATED WITH THE ADDITION OF A NEW LAV. THE ENTRY | | | WALL HAS BEEN MOVED WITH THE ENTRY DOOR IN CONFLICT | | | WITH THE UNISEX TOLIET ROOM NOT THE EXISTING STAFF | | | RESTROOM. NOTE THE UNISEX TOLIET ROOM CAN HAVE A | | | INSWING DOOR SO IT DOESN'T BLOCK THE MENS RESTROOM | | | DOOR. | | | 2014 FBC-ACCESSIBILITY CODE 603.2.3 EXCEP. # 2. DOOR | | | SWING. | | | 2014 FBC-P 403.5 UNISEX RESTROOMS SEE PLUMBING | | | COMMENTS. | | | | | | 5) SHEET A120.1 EXISTING BEER COOLER 121 HAS BEEN | | | EXSPANDED THERE WAS A HALL 111 THAT LEAD TO THE BACK OF | | | HOUSE EXIT PASSAGEWAY WITH RATED DOOR. THIS DOOR HAS | | | BEEN ELIMINATED, THE PLANS DO NOT SHOW HOW THE FIRE | | | RATING OF THE EXIT PASSAGEWAY WAS MAINTAINED. 2014 | | | FBC-B 1023.3. | | | | | | 6) SHEET A120.1 LUMINARIES LOUNGE SHOWS A RAISED | | | PLATFORM, UNDER PERMIT 13010420 THIS WAS A STAGE, IT | | | APPEARS THERE IS NEW KNEE WALLS AND WHAT APPEARS TO BE | | | STEPS. PLEASE PROVIDE AT WHAT ELEVATION THE PLATFORM IS | | | ABOVE FINISH FLOOR. 107.2.1.3 ADDITIONAL INFORMATION IS | | | REQUIRED. | | | | | | 6A) SHEET A120.1 THE PROPOSED PLANS SHOW WORK ON THE | | | EAST AND SOUTH OUTSIDE DINING AREA WITH WALLS MOVED, | | | DOORS OPENINGS BEING MODIFIED, A NEW OUTSIDE LOUNGE | | | AREA WALLS REMOVED, THE KITCHEN NEW COOLERS, OLD ONES | | | MOVED BAR LOCATIONS AND WALLS MOVED ETC.... | | | | | | 7) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A | | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | | THIS REVIEW. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-08-24 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2015-08-24 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2015-08-24 |
Time |
15:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2015-10-07 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-10-07 |
Time |
18:05 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-10-07 |
Time |
17:39 |
Sent To |
I |
|
| Notes |
| 2015-10-07 18:07:03 | ALL PREVIOUSLY MENTIONED COMMENTS HAVE BEEN | | | SATISFACTORILY ADDRESSED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2015-09-29 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-09-29 |
Time |
16:10 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-09-29 |
Time |
15:25 |
Sent To |
|
|
| Notes |
| 2015-09-29 16:11:41 | TWO OF THE FOUR COMMENTS HAVE NOT BEEN PROPERLY | | | ADDRESSED. I PLACED A CALL IN TO THE ARCHITECT. AFTER I | | | TALK TO HIM I MAY APPROVE W/PROVISO. FILE IS ON MY DESK | | | IN THE MEANTIME. | | | | | | 1. ALL THAT WAS DONE WAS A TYPOGRAPHICAL CORRECTION TO | | | NOTE 29, BUT NOTHING WAS CHANGED IN THE WORDING TO | | | ADDRESS THE MATTER AT HAND. | | | 2. A NOTE AS TO THE SIGN CHANGEOUT WAS MADE. MY COMMENT | | | HAS NOTHING TO DO WITH WHATEVER SIGNAGE IS THER NOW, | | | BUT WITH THE SIGN OUTLETS REQUIRED BY CODE FOR THE NEW | | | LOCATION. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2015-08-26 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-08-26 |
Time |
17:36 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-08-26 |
Time |
16:30 |
Sent To |
Z |
|
| Notes |
| 2015-08-26 17:44:49 | PLEASE NOTE THAT I, MIKE ALBARRAN, ELECTRICAL PLANS | | | EXAMINER HAVE COMPLETED THE REVIEW OF THE ABOVE | | | MENTIONED JOB. BELOW ARE THE COMMENTS WITH REGARDS TO | | | THE REQUIRED CORRECTIONS. THE FOLLOWING ITEMS SHALL BE | | | CORRECTED AND THE PLANS RESUBMITTED FOR ANOTHER REVIEW. | | | | | | 1. PAGE A400.2 DETAILS INDICATE THAT COMMUNICATING | | | PARTITIONS ARE BEING USED, THEREFORE EVERY ELECTRICAL | | | OUTLET BOX IN A FIRE RATED WALL SHALL BE PROTECTED WITH | | | AN APPROVED FIRE STOPPING MATERIAL. | | | 2. PAGE E100 NOTE 29 SHALL BE CORRECTED TO ADDRESS THE | | | ABOVE COMMENTS. THE WAY NOTE 29 IS STATED ONLY APPLIES | | | WHEN USING NON-COMMUNICATING PARTITIONS. | | | 3. PAGE E120 REVISIT THE EMERGENCY LIGHTING ARRANGEMENT | | | TO PROVIDE PROPER ILLUMINATION THROUGH OUT UNDER | | | EMERGENCY CONDITIONS. WALK-IN COOLER & FREEZER SHOULD | | | HAVE AN EMERGENCY LIGHT INSIDE AS WELL. | | | 4. PAGE E120 NEC 600.5(A) REQUIRES THAT THERE BE A | | | DEDICATED SIGN OUTLET ADJACENT TO EVERY PEDESTRIAN | | | DOOR. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND LEAVE THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | | CONTACT ME DIRECTLY. | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2015-09-14 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2015-09-14 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2015-09-14 |
Time |
14:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2015-08-20 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2015-08-20 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2015-08-20 |
Time |
10:33 |
Sent To |
|
|
| Notes |
| 2015-08-20 11:05:46 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | 1) SHEET A 200.1, THERE IS AN INCORRECT REFERENCE TO | | | THE FIRE CODE, FFPC (2010). THE CORRECT CODE REFERENCE | | | IS 2012. | | | | | | 2) SHEET A120.1, THE DOOR FROM ROOM 116 (BY THE OFFICE | | | 114) SHALL SWING IN THE PATH OF EXIT TRAVEL PER NFPA | | | 101, CHAPTER 7. THE OCCUPANCY OF THE ROOM 116 IS | | | GREATER THAN 50. | | | | | | 3) SHEET A 200.1, A LIGHTWEIGHT ROOF AND FLOOR TRUSS | | | SIGN SHALL BE INSTALLED PER FL STATUTUE. | | | | | | PER FLORIDA 69A-60.0081; NOTICE SIGNAGE IS REQUIRED FOR | | | STRUCTURES WITH LIGHT-FRAME TRUSS-TYPE CONSTRUCTION. | | | ANY COMMERCIAL, INDUSTRIAL, OR ANY MULTIUNIT | | | RESIDENTIAL STRUCTURE OF THREE UNITS OR MORE WHICH USES | | | HORIZONTAL OR VERTICAL LIGHT-FRAME TRUSS-TYPE | | | CONSTRUCTION IN ANY PORTION SHALL BE MARKED WITH A | | | MALTESE CROSS SIGN MEASURING 8 INCHES HORIZONTALLY AND | | | 8 INCHES VERTICALLY, OF A BRIGHT RED REFLECTIVE COLOR. | | | THE APPROVED SYMBOL SHALL BE PLACED WITHIN 24 INCHES TO | | | THE LEFT OF THE MAIN ENTRY DOOR. | | | 1. STRUCTURES WITH LIGHT-FRAME TRUSS ROOFS SHALL BE | | | MARKED WITH THE LETTER "R". | | | 2. STRUCTURES WITH LIGHT-FRAME TRUSS FLOOR SYSTEMS | | | SHALL BE MARKED WITH THE LETTER "F". | | | 3. STRUCTURES WITH LIGHT-FRAME TRUSS FLOOR AND ROOF | | | SYSTEMS SHALL BE MARKED WITH THE LETTERS "R/F". | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2015-10-08 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2015-10-07 |
Time |
15:13 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-10-07 |
Time |
15:12 |
Sent To |
|
|
| Notes |
| 2015-10-07 15:20:53 | 1ST REVIEW: FBC 2014 | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | | | | | | | GAS PROVISO: SEPARATE PERMIT REQUIRED. | | | | | | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT CLEARLY SHOWS ALL | | | CUT SECTIONS OF PIPE AND CORRESPONDING LENGTHS PER | | | FBC-2014 FUEL GAS, SECS. 402.4.1, 402.4.2. | | | | | | 2. SHOW TYPE OF PIPING MATERIAL BEING INSTALLED, ALL | | | PIPE SIZES, AND THE EHD NUMBER OF CORRUGATED STAINLESS | | | STEEL TUBING FOR EACH PIPE SIZE IF BEING USED. WPB | | | AMENDMENTS TO FBC SEC. 107.2.1. | | | | | | 3. TYPE OF GAS, (LP OR NATURAL). | | | | | | 4. BTU LOAD OF EACH APPLIANCE AND THE TOTAL BTU LOAD ON | | | THE SYSTEM. REFER TO THE FBC-2014 FUEL GAS SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU 402.4(37). | | | | | | 5. SHOW THE DISTANCE FROM THE POINT OF DELIVERY, | | | (METER), TO THE MOST REMOTE OUTLET IN THE BUILDING | | | AND/OR SYSTEM PER THE FBC-2014 FUEL GAS APPENDIX A ? | | | USE OF CAPACITY SECTION A.3.1(4) & 2014 FUEL GAS CODE | | | SEC. 402.4.1. | | | | | | 6. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE | | | FBC-2014 FUEL GAS CODE SEC. 304. | | | | | | 7. INDICATE THE DELIVERY PRESSURE (PSI) PER FBC-2014 | | | FUEL GAS SEC. 402.2. IF NATURAL GAS SPECIFY .5 PSI OR 2 | | | PSI. | | | | | | 8. SUBMIT A DETAIL SHOWING THE TYPE, LOCATION, SIZE AND | | | TERMINATION OF THE GAS VENTS PER FBC-2014 FUEL GAS CODE | | | SEC. 502 THRU 505. | | | | | | 9. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS FOR ALL | | | GAS EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA | | | 54, NFPA 58, AND FBC-2014 FUEL GAS SEC. 402.2 | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2015-10-07 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-10-07 |
Time |
18:35 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-10-06 |
Time |
16:21 |
Sent To |
|
|
| Notes |
| 2015-10-07 18:37:08 | 10/7/15 PASSED ELECTRICAL REVIEW. SEPARATE PERMIT IS | | | REQUIRED FOR GAS, BUT AN F WAS ENTERED INSTEAD OF AN N. | | | CONTRACTOR NOTIFIED VIA EMAIL. SENT TO LARGE DENIED BIN | | | "D". MA |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
|
Date |
2015-10-06 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2015-09-29 |
Time |
16:20 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2015-09-09 |
Time |
10:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-08-28 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-08-26 |
Time |
17:45 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2015-08-14 |
Time |
14:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2015-09-15 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-09-15 |
Time |
17:09 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-09-15 |
Time |
17:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2015-08-18 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-08-18 |
Time |
15:30 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-08-18 |
Time |
15:29 |
Sent To |
|
|
| Notes |
| 2015-08-18 15:44:19 | 1ST REVIEW: FBC 2014 MECHANICAL | | | PERMIT #15080547 | | | 8/18/15 | | | | | | 1) REFER TO SECTION 809.1 FBC-14 EXISTING BUILDING CODE | | | AND PROVIDE VENTILATION CALCULATIONS FOR ALL ROOMS AND | | | SPACES IN ACCORDANCE WITH TABLE 403.3 FBC-14 | | | MECHANICAL. INDICATE THE REQUIRED O/A CFM'S AND THE | | | AMOUNT OF CFM'S BEING PROVIDED BY THE EXISTING | | | SYSTEM(S). | | | 2) THE CITY OF WEST PALM BEACH DEVELOPMENT SERVICES | | | DEPARTMENT REQUIRES SEPARATE PERMITS FOR ALL KITCHEN | | | HOOD, AND WALK-IN COOLER AND FREEZER INSTALLATIONS- THE | | | PLAN IS INDICATING BOTH. PLEASE PLACE NOTES ON THE | | | PLANS ACCORDINGLY. | | | IN REFERENCE TO THIS PERMIT SET OF PLANS IT IS | | | NECESSARY TO INDICATE HOW MAKE-UP AIR IS BEING PROVIDED | | | FOR THE NEW EXHAUST HOOD TO VERIFY PROPER AIR BALANCING | | | WITHIN THE ALTERED SPACE- REFER TO SECTION 508 FBC-14 | | | MECHANICAL. | | | 508.1 MAKEUP AIR. | | | MAKEUP AIR SHALL BE SUPPLIED DURING THE OPERATION OF | | | COMMERCIAL KITCHEN EXHAUST SYSTEMS THAT ARE PROVIDED | | | FOR COMMERCIAL COOKING APPLIANCES. THE AMOUNT OF MAKEUP | | | AIR SUPPLIED TO THE BUILDING FROM ALL SOURCES SHALL BE | | | APPROXIMATELY EQUAL TO THE AMOUNT OF EXHAUST AIR FOR | | | ALL EXHAUST SYSTEMS FOR THE BUILDING. THE MAKEUP AIR | | | SHALL NOT REDUCE THE EFFECTIVENESS OF THE EXHAUST | | | SYSTEM. MAKEUP AIR SHALL BE PROVIDED BY GRAVITY OR | | | MECHANICAL MEANS OR BOTH. MECHANICAL MAKEUP AIR SYSTEMS | | | SHALL BE AUTOMATICALLY CONTROLLED TO START AND OPERATE | | | SIMULTANEOUSLY WITH THE EXHAUST SYSTEM. MAKEUP AIR | | | INTAKE OPENING LOCATIONS SHALL COMPLY WITH SECTION | | | 401.4. | | | 508.1.1 MAKEUP AIR TEMPERATURE. | | | THE TEMPERATURE DIFFERENTIAL BETWEEN MAKEUP AIR AND THE | | | AIR IN THE CONDITIONED SPACE SHALL NOT EXCEED 10 | | | DEGREES F (6 DEGREES C) EXCEPT WHERE THE ADDED HEATING | | | AND COOLING LOADS OF THE MAKEUP AIR DO NOT EXCEED THE | | | CAPACITY OF THE HVAC SYSTEM. | | | 3) SHEET FS500.1: PLEASE PROVIDE DETQILS ON THE PLANS | | | THAT CORRELATE WITH MECHANICAL NOTE 2. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2015-10-07 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2015-10-07 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2015-10-07 |
Time |
15:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2015-09-11 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2015-09-11 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2015-09-11 |
Time |
16:18 |
Sent To |
|
|
| Notes |
| 2015-09-11 16:41:18 | PLUMBING COMMENTS: | | | | | | | | | 1. SHOW THE DISTANCE FROM THE POINT OF DELIVERY, | | | (METER), TO THE MOST REMOTE OUTLET IN THE BUILDING | | | AND/OR SYSTEM PER THE FBC-2014 FUEL GAS APPENDIX A ? | | | USE OF CAPACITY SECTION A.3.1(4) & 2014 FUEL GAS CODE | | | SEC. 402.4.1 | | | 1ST REVIEW: FBC 2014 | | | 2.PLEASE PROVIDE SPEC SHEETS FOR WATER HEATER AND ALL | | | KITCHEN EQUIPMENT. | | | WPB AMEND . SEC. 107.2.1 | | | 3.SHEET P220 KITCHEN EQUPMENT SCHDULE IS CALLING FOR | | | 140* HOT WATER FOR PRE RINSE FAUCETS1.1 -4.1 IT DOES | | | NOT SHOW THAT ON WATER RISER DIAGRAM PLEASE SHOW. | | | WPB AMEND . SEC. 107.2.1 | | | 4.SHEET P222 ON THE WATER RISER THE FIXTURES ARE NOT | | | LABALLED AND THERE IS NO STUB. FOR DISWASHER PLEASE | | | CORRECT. | | | WPB AMEND . SEC. 107.2.1 | | | 5.SHEET P222 WATER RISER PIPING FOR THE PRE RINSE | | | FAUCETS AND DISHWASHER APPEAR SMALL. SHOW FLOW RATE FOR | | | ALL FAUCETS AND DISHWASHER. | | | WPB AMEND . SEC. 107.2.1 | | | 6.SHOW CALC. COMBUSTION AIR FOR GAS EQUIPMENT. | | | WPB AMEND . SEC. 107.2.1 | | | | | | | | | | | | | | | | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2015-08-26 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2015-08-26 |
Time |
06:50 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2015-08-26 |
Time |
06:50 |
Sent To |
|
|
| Notes |
| 2015-08-26 06:50:22 | 1ST REVIEW: FBC 2014 | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | 561-805-6711 | | | [email protected] | | | | | | | | | COMMENTS: | | | | | | 1. SCOPE OF WORK UNCLEAR PLEASE CLARIFY. ARE BATHROOMS | | | EXISTING WITH NO CHANGES.IS THER ANY CHANGES TO GAS | | | PIPING. ETC. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | 2. SHOW CALCULATIONS FOR GREASE TRAP TO DETERMINE IF | | | EXISTING SIZE IS ADEQUATE FOR NEW FIXTURE DRAINAGE. | | | PER WPB AMEND. TO FBC SEC. 107.2.1.,3 | | | 3.SHEET INDEX SHOWS P222 AS PLUMBING ISOMETRICS SHEET | | | P222 IS MISSING PLEASE PROVIDE, PLUMBING ISOMETRIC | | | DRAWINGS. | | | PER WPB AMEND. TO FBC SEC. 107.3.5.1.3(13) |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2015-09-14 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2015-09-14 |
Time |
16:26 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2015-09-14 |
Time |
16:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2015-08-27 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2015-08-27 |
Time |
14:50 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2015-08-27 |
Time |
14:50 |
Sent To |
|
|
| Notes |
| 2015-08-27 15:13:38 | FAILED | | | | | | 1) THE CITYPLACE MANAGEMENT APPROVAL STAMP IS REQUIRED | | | ON THE PLANS. | | | | | | 2) PLEASE VERIFY THAT A MINIMUM 60 INCH (5 FOOT) WIDE | | | PEDESTRIAN PATH REMAINS THROUGH THE OUTDOOR DINING AREA | | | UNDER THE COVERED ARCADE. THIS DIMENSION SHALL BE SHOWN | | | ON THE PLANS. | | | | | | 3) THE LIFE SAFETY PLAN SHOWS TABLES AND CHAIRS | | | EXTENDING PAST THE OUTDOOR DINING AREA. THIS IS THE | | | PUBLIC RIGHT-OF-WAY AND MAY NOT INCLUDE TABLES AND | | | CHAIRS WITHOUT THE APPROVAL OF A SIDEWALK CAFE PERMIT. | | | | | | 4) THE RAILING SHOWN ALONG GARDENIA STREET REQUIRES A | | | SEPARATE FENCE PERMIT, WITH PLANS. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | 2015-08-17 11:36:40 | 8/17/15 |
|
|
|