| Plan Review Stops For Permit 15080415 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2016-02-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-02-24 |
Time |
17:23 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-02-18 |
Time |
19:01 |
Sent To |
|
|
| Notes |
| 2016-02-24 17:23:55 | APPROVED WITH EXCEPTIONS. | | | 1) A SEPARATE PERMIT APPLICATION, REVIEW AND PLANS ARE | | | REQUIRED FOR THE GENERATOR. | | | 2) ADDITIONAL INFORMATION AND DETAILS ARE REQUIRED TO | | | BE SUBMITTED FOR THE EXTERIOR MASONRY FIREPLACE AND | | | CHIMNEY. | | | 3) REVISION REQUIRED FOR SHEET S-7 TO CORRECT WEST | | | ELEVATION SO THAT IT CORRESPONDS WITH THE FLOOR PLANS. | | 2016-02-08 17:13:24 | SEE GENERATOR SUBMITTAL 16020245 TRAVELING WITH. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2016-01-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-01-22 |
Time |
16:50 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-01-22 |
Time |
06:57 |
Sent To |
|
|
| Notes |
| 2016-01-22 13:37:59 | PLAN | | | REVIEW COMMENTS | | | | | | 2ND REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) (NEW COMMENT) THE PERMIT APPLICATION IS MISSING FROM | | | THE RESUBMITTAL. IF THE ORIGINAL IS NOT LOCATED A | | | REPLACEMENT WILL BE REQUIRED. | | | | | | 2) (PREVIOUS COMMENT) THE ENERGY COMPLIANCE FORMS | | | SPECIFY R-20 CEILING INSULATION AND PLAN SHEET A-302 | | | HAS R-19 CEILING INSULATION. FBC 107.2.1 | | | | | | 3) (PREVIOUS COMMENT) THE REFERENCES TO THE STANDARDS | | | ON SHEET S-1 ARE INCORRECT. THEY SHOULD BE AS FOLLOWS: | | | ACI 318-11, ACI 530-11, ACI 530.1-11, ASCE 5-11, ASCE | | | 6-11, TMS 402-11 AND TMS 602-11. THE 2011 EDITIONS OF | | | THESE STANDARDS ARE THE ONES THAT ARE REFERENCED IN | | | CHAPTER 46 THE FBC FIFTH EDITION (2014). | | | | | | 4) (NEW COMMENT) THE COMPONENT AND CLADDING PRESSURES | | | FOR THE WALL AREAS ON SHEET S-1 ARE LOW FOR A TWO STORY | | | STRUCTURE (25' MEAN ROOF HEIGHT) LOCATED IN EXPOSURE C. | | | FBC-R301.2.1 | | | | | | 5) (PREVIOUS COMMENT) THE WEST ELEVATION DOES NOT MATCH | | | THE FLOOR PLANS. THE EXTERIOR DOOR (ED 109) TO THE | | | MASTER BATH IS SHOWN AS A WINDOW AND A WINDOW IS | | | MISSING. THE SECOND FLOOR PLAN HAS TWO WINDOWS AND THE | | | ELEVATION HAS THREE. FBC 107.2.1 SEE SHEETS A-100, | | | A-101, A-201 AND S-7 | | | | | | 6) (PREVIOUS COMMENT) ADDITIONAL INFORMATION IS | | | REQUIRED FOR THE MASONRY FIREPLACE AND CHIMNEY TO SHOW | | | THAT IT WILL COMPLY WITH FBC R1001. PROVIDE DIMENSIONS | | | AND DETAILS OF ALL PARTS AND COMPONENTS. FBC 107.2.1 | | | PROVIDE FIREBOX, DAMPER, SMOKE CHAMBER DIMENSIONS AND | | | FLUE DIMENSIONS. | | | | | | 7) (PREVIOUS COMMENT) FBC 107.3.4 - PROVIDE TWO SETS OF | | | PRODUCT APPROVALS FOR THOSE PRODUCTS WHICH ARE | | | REGULATED BY DCA RULE 9N-3 THAT HAVE BEEN REVIEWED AND | | | APPROVED IN WRITING BY THE DESIGNER OF RECORD. NO | | | PRODUCT APPROVALS WERE SUBMITTED FOR THE EXTERIOR DOORS | | | OR WINDOWS. THE NOA NUMBERS ON THE LETTER FROM THE | | | ARCHITECT DO NOT MATCH THE ONES THAT WERE SUBMITTED. | | | ALSO, LIST ALL OF THE PRODUCT APPROVALS ON ONE LETTER. | | | | | | 8) (PREVIOUS COMMENT) SUBMIT TWO SETS OF THE PRODUCT | | | EVALUATION REPORT AND INSTALLATION INSTRUCTIONS FOR THE | | | SPRAY FOAM INSULATION. FBC - R 316 SUBMIT THE PRODUCT | | | EVALUATION REPORT FOR THE ICYNENE SPRAY FOAM. | | | | | | 9) (PREVIOUS COMMENT) SUBMIT PRODUCT APPROVALS, | | | MANUFACTURES' SPECIFICATIONS WITH INSULATION | | | INSTRUCTIONS FOR THE COLONIAL AND BAHAMA SHUTTERS SHOWN | | | ON THE ELEVATION DRAWINGS. FBC 107.2.1 & R301.2.1 THE | | | PRODUCT APPROVAL FOR THE BAHAMA SHUTTERS IS EXPIRED AND | | | NOTHING WAS SUBMITTED FOR THE COLONIAL SHUTTERS. | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-10-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-10-01 |
Time |
18:23 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-09-28 |
Time |
17:59 |
Sent To |
|
|
| Notes |
| 2015-09-29 11:33:36 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE OWNER/AGENT IS REQUIRED TO SIGN THE ENERGY | | | COMPLIANCE FORMS. FBC ENERGY CONSERVATION R103.1.1.2 | | | | | | 2) THE ENERGY COMPLIANCE FORMS SPECIFY R-20 CEILING | | | INSULATION AND PLAN SHEET A-302 HAS R-19 CEILING | | | INSULATION. FBC 107.2.1 | | | | | | 3) SUBMIT A SITE DRAINAGE PLAN THAT SHOWS COMPLIANCE | | | WITH FBC - R401.3 SURFACE DRAINAGE SHALL BE DIVERTED TO | | | A STORM SEWER CONVEYANCE OR OTHER APPROVED POINT OF | | | COLLECTION THAT DOES NOT CREATE A HAZARD. LOTS SHALL BE | | | GRADED TO DRAIN SURFACE WATER AWAY FROM FOUNDATION | | | WALLS. THE GRADE SHALL FALL A MINIMUM OF 6 INCHES (152 | | | MM) WITHIN THE FIRST 10 FEET (3048 MM). | | | | | | 4) FBC - R302.5.1 REQUIRES A SELF-CLOSING DEVICE ON THE | | | DOOR FROM THE GARAGE TO THE HABITABLE SPACE. | | | | | | 5) GENERAL NOTE 1 ON SHEET A-100 INCORRECTLY REFERENCES | | | THE 2010 FBC. THE FBC FIFTH EDITION (2014) WENT INTO | | | EFFECT ON JUNE 30, 2015. ALL NEW PERMITS APPLIED FOR ON | | | OR AFTER THAT DATE ARE REQUIRED TO COMPLY WITH AND | | | REFERENCE THE FBC FIFTH EDITION. | | | | | | 6) THE STRUCTURAL DESIGN CRITERIA NOTES ON SHEET S-1 | | | REFERENCE THE 2010 FBC. THE FBC FIFTH EDITION (2014) | | | WENT INTO EFFECT ON JUNE 30, 2015. ALL NEW PERMITS | | | APPLIED FOR ON OR AFTER THAT DATE ARE REQUIRED TO | | | COMPLY WITH AND REFERENCE THE FBC FIFTH EDITION. | | | | | | 7) THE REFERENCES TO THE FOLLOWING STANDARDS ON SHEET | | | S-1 ARE INCORRECT, THEY SHOULD BE AS FOLLOWS: ACI | | | 318-11, ACI 530-11, ACI 530.1-11, ASCE 5-11, ASCE 6-11, | | | TMS 402-11 AND TMS 602-11. THE 2011 EDITIONS OF THESE | | | STANDARDS ARE THE ONES THAT ARE REFERENCED IN CHAPTER | | | 46 THE FBC FIFTH EDITION (2014). | | | | | | 8) ON THE LOW ROOF AND HIGH ROOF FRAMING PLANS ON SHEET | | | S-3, THE SECTION ID TAGS ARE INCORRECT. THEY DO NOT | | | CORRESPOND WITH THE CORRECT SECTION DETAILS ON S-5. FBC | | | 107.2.1 | | | | | | 9) SECTION DETAIL 4 0N S-5 IS BLANK , HOWEVER, THERE IS | | | A TAG FOR IT ON S-3. PLEASE CLARIFY. FBC 107.2.1 | | | | | | 10) THE WEST ELEVATION DOES NOT MATCH THE FLOOR PLANS. | | | THE EXTERIOR DOOR (ED 109) TO THE MASTER BATH IS NOT | | | SHOWN. THE SECOND FLOOR PLAN HAS TWO WINDOWS AND THE | | | ELEVATION HAS THREE. FBC 107.2.1 | | | | | | 11) ADDITIONAL INFORMATION IS REQUIRED FOR THE MASONRY | | | FIREPLACE AND CHIMNEY TO SHOW THAT IT WILL COMPLY WITH | | | FBC R1001. PROVIDE DIMENSIONS AND DETAILS OF ALL PARTS | | | AND COMPONENTS. FBC 107.2.1 | | | | | | 12) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS | | | FOR THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE 9N-3 | | | THAT HAVE BEEN REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD. | | | | | | 13) SPECIFY THE METHOD OF ATTACHMENT THAT WILL BE USED | | | TO INSTALL THE BORAL CEMENT ROOF TILE AND RESIST THE | | | REQUIRED OVERTURN MOMENT. IF AN ADHESIVE WILL BE USED | | | SUBMIT TWO SETS OF ITS PRODUCT APPROVAL. FBC - R | | | 301.2.1 | | | | | | 14) SUBMIT TWO SETS OF THE PRODUCT EVALUATION REPORT | | | AND INSTALLATION INSTRUCTIONS FOR THE SPRAY FOAM | | | INSULATION. FBC - R 316 | | | | | | 15) SUBMIT PRODUCT APPROVALS, MANUFACTURES' | | | SPECIFICATIONS WITH INSULATION INSTRUCTIONS FOR THE | | | COLONIAL AND BAHAMA SHUTTERS SHOWN ON THE ELEVATION | | | DRAWINGS. FBC 107.2.1 & R301.2.1 | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2016-02-19 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-02-19 |
Time |
18:15 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-02-18 |
Time |
19:01 |
Sent To |
|
|
| Notes |
| 2016-02-19 18:15:59 | APPROVED WITH EXCEPTIONS. REDLINE PLANS. | | | A SEPARATE PERMIT IS REQUIRED FOR THE GENERATOR. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2016-01-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-01-22 |
Time |
18:56 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-01-22 |
Time |
07:10 |
Sent To |
|
|
| Notes |
| 2016-01-22 18:25:40 | 2ND REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY ELECTRIC | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) FBC 107.2.1 - INFORMATION ON CONSTRUCTION DOCUMENTS. | | | ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND | | | ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE OF | | | THE PERSON RESPONSIBLE FOR THE DESIGN. THE LOAD | | | CALCULATIONS, RISER DIAGRAM AND PANEL SCHEDULE ARE | | | MISSING THIS. THE RISER DIAGRAM AND PANEL SCHEDULE ARE | | | MISSING FROM THE RE-SUBMITTAL. | | | | | | 2) SEPARATE PERMIT, APPLICATION AND REVIEW IS REQUIRED | | | FOR THE GENERATOR. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2015-10-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-10-01 |
Time |
18:53 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-10-01 |
Time |
18:53 |
Sent To |
|
|
| Notes |
| 2015-10-01 18:34:51 | 1ST REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY ELECTRIC | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) FBC 107.2.1 - INFORMATION ON CONSTRUCTION DOCUMENTS. | | | ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND | | | ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE OF | | | THE PERSON RESPONSIBLE FOR THE DESIGN. THE LOAD | | | CALCULALTIONS, RISER DIAGRAM AND PANEL SCHEDULE ARE | | | MISSING THIS. | | | | | | 2) NEC 210.52(A) - (H) OUTLET SPACING, IT APPEARS SOME | | | POINTS ALONG THE WALL SPACE EXCEED 6' FROM AN OUTLET IN | | | THE FAMILY ROOM AND MASTER BEDROOM. | | | | | | 3) NEC 210.52 (C) (1) - A RECEPTACLE OUTLET SHALL BE | | | INSTALLED AT EACH COUNTERTOP SPACE 12 INCHES OR WIDER | | | SO THAT NO POINT ALONG THE WALL LINE IS MORE THAN 2 | | | FEET MEASURED HORIZONTALLY FROM A RECEPTACLE OUTLET IN | | | THAT SPACE.ALSO THE KITCHEN COUNTER TOP APPEARS TO BE | | | MISSING A RECEPTACLE OUTLET. | | | | | | 4) NEC 406.11 - TAMPER-RESISTANT RECEPTACLES ARE | | | REQUIRED. | | | | | | 5) NEC 210.12 (B) - OUTLETS ARE REQUIRED TO BE AFCI | | | PROTECTED. | | | | | | 6) NEC 210.52 (E)(1) - AT LEAST ONE RECEPTACLE OUTLET | | | ACCESSIBLE WHILE STANDING AT GRADE LEVEL AND LOCATED | | | NOT MORE THAN 6.5 FT. ABOVE GRADE SHALL BE INSTALLED AT | | | THE FRONT AND BACK OF THE DWELLING. RECEPTACLE IS | | | REQUIRED AT FRONT. | | | | | | 7) NEC 250.94 - INTERSYSTEM BONDING TERMINATION SHALL | | | BE PROVIDED. | | | | | | 8) NEC 250.104(B) THE GAS PIPING IS REQUIRED TO BE | | | BONDED. | | | | | | 9) SEPARATE PERMIT, APPLICATION AND REVIEW IS REQUIRED | | | FOR THE GENERATOR. | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2016-02-16 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-02-16 |
Time |
06:48 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-02-16 |
Time |
06:17 |
Sent To |
|
|
| Notes |
| 2016-02-16 06:50:34 | SEPARATE PERMIT REQD. FOR GAS. | | | MANUFACTURER'S INSTALLATION MANUALS FOR ALL GAS | | | APPLIANCES/EQUIPMENT SHALL BE ONSITE FOR INSPECTION. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2016-01-13 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-01-13 |
Time |
12:14 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-01-13 |
Time |
09:12 |
Sent To |
|
|
| Notes |
| 2016-01-13 10:26:07 | 1) FYI - THE GAS PERMIT SHALL BE DONE UNDER A SEPARATE | | | PERMIT WITH A SEPARATE PERMIT APPLICATION.SINCE THE GAS | | | INFORMATION AND DRAWINGS HAVE BEEN SUBMITTED A REVIEW | | | WILL BE PERFORMED ON THE DOCUMENTS. | | | 2) THE ARCHITECTURAL PLAN A-100 SHOWS THE FIREPLACE AS | | | GAS BUT IT IS NOT SHOWN ON THE GAS RISER OR ON THE GAS | | | PLAN VIEW DRAWING. CLARIFY. | | | 3) SUBMIT MANUFACTURER'S SPECIFICATION SHEETS FOR ALL | | | GAS APPLIANCES. THE SPECIFICATION SHEETS SHALL CLEALY | | | SHOW THAT THE APPLIANCES ARE LISTED AND LABELED IN | | | ACCORDANCE WITH THE 2014 FBCR SEC.G2404.3. 2ND REQUEST. | | | 4) SHOW THE CORRESPONDING EHD FOR EACH SIZE OF CSST.THE | | | DIFFERENT EHD NUMBERS CARRY DIFFERENT BTU LOADS.2ND | | | REQUEST. | | | 5) SUBMIT COMBUSTION AIR CALCULATIONS FOR THE DRYERS | | | LOCATED IN THE LAUNDRY ROOMS. REFER TO 2014 | | | FBC-RESIDENTIAL SEC. G2407.1. NOTE: THERE IS AN E-MAIL | | | IN THE DOCUMENTS FROM A DANIEL DOLBEE THAT STATES THE | | | RANGE IS 154,00 BTU'S BUT THE GAS DRAWING SHOWS THE | | | RANGE AS 108,000 BTU'S .CLARIFY. | | | 6) THE 2 PSI LINE TO THE GENERATOR, POOL HEATER AND | | | TANKLESS WATER HEATER IS SHOWN AS PE PIPE ON THE PLAN | | | DRAWING AND AS CSST ON THE RISER DIAGRAM. WHICH IS IT? | | | IF CSST, IT IS UNDERSIZED. CLARIFY. | | | 7) SIZE THE GAS BRANCCH LINES TO THE GENERATOR,POOL | | | HEATER AND TANKLESS WATER HEATER. WPB AMEND. TO FBC | | | SEC. 107.3.5.3. | | | 8) SIZE ALL SECTIONS OF THE UNDERGROUND GAS PIPING | | | SYSTEM ON THE RISER DIAGRAM. | | | 9) IDENTIFY THE COOKTOP ON THE GAS RISER AND SHOW THE | | | BTU LOAD OF THE APPLIANCE.WPB AMEND. TO FBC SEC. | | | 107.3.5.3. | | | 10) SHOW THE LENGTH OF THE SECTION OF PIPE RISING UP | | | INTO THE CEILING. WPB AMEND. TO FBC SEC. 107.3.5.3. | | | 11) SHOW THE LENGTH OF ALL DROPS TO THE APPLIANCES AND | | | THE LENGTH OF THE SECTION OF PIPE TO THE 2ND FLOOR. IT | | | APPEARS LIKE THE TOTAL DEVELOPED LENGTH WILL EXCEED 100 | | | FEET. | | | 12) THE 1/2 PSI GALVANIZED PIPING UP TO THE CEILING IS | | | UNDERSIZED. | | | 13) SHOW THE LENGTH OF EACH CUT SECTION OF PIPE ON THE | | | RISER DIAGRAM. 2014 FBCR SEC. G2413.4. | | | 14) THE GREEN MARKER USED ON THE SIZING TABLE HAS MADE | | | THE NUMBERS ON THE TABLES ILLEGIBLE. SUBMIT CLEAN | | | SIZING TABLES. | | | 15) SHT. A-100 SHOWS THE TANKLESS WATER HEATER IN A | | | WEATHERPROOF ENCLOSURE. SUBMIT DETAILS ON THE WATER | | | HEATER AS TO HOW COMBUSTION AIR AND EXHAUST WILL | | | ADDRESSED. WILL BE PROVIDED. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2015-08-21 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-08-21 |
Time |
02:54 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-08-21 |
Time |
02:27 |
Sent To |
|
|
| Notes |
| 2015-08-21 02:54:06 | 1) IDENTIFY THE MODEL OF THE GENERATOR ON THE GENERAC | | | SPEC. SHEETS. WPB AMEND. TO FBC SEC. 107.2.1. | | | 2) SHOW THE LOCATION OF THE POOL HEATER AND GENERATOR | | | ON THE PLANS. WPB AMEND. TO FBC SEC. 107.2.1. | | | 3) THE GENERATOR IS NOT SHOWN ON THE GAS DRAWING OR | | | INCLUDED IN THE DESIGN LOAD OF THE GAS SYSTEM. | | | 4) THE GAS DRAWING SHOWS THE DRYER AS GAS BUT IT IS | | | SHOWN ON THE PLANS AND ON THE ELECTRICIAN'S LOAD CALCS | | | AS ELECTRIC. CLARIFY. WPB AMEND. TO FBC SEC. 107.2.1. | | | 5) SHOW THE LOCATION OF THE GAS WATER HEATERS ON THE | | | PLANS. WPB AMEND. TO FBC SEC. 107.2.1. | | | 6) SUBMIT MANUF. SPECS FOR ALL GAS APPLIANCES / | | | EQUIPMENT.APPLIANCES /EQUIPMENT SHALL BE LISTED AND | | | LABELED PER 2014 FBC-R SEC. G2404.3. | | | 7) SUBMIT A GAS PLAN SHOWING THE LOCATION OF THE PE | | | PIPE IN RELATION TO THE STRUCTURE. PE PIPE CAN ONLY BE | | | USED OUTSIDE UNDERGROUND. 2014 FBC-R SEC.G2415.17.1. | | | 8) SHOW THE LOCATION OF ALL THE MP | | | REGULATORS.REGULATORS SHALL COMPLY WITH 2014 FBC-R SEC. | | | G2421.2 (4) [ACCESSIBLE & VENTED TO EXTERIOR], G 2421.2 | | | (5) (6) [SUPPLIED WITH TEE FITTING FOR MEASURING | | | INSTRUMENT & SEDIMENT TRAP.] | | | 9) SUBMIT MANUF. SPECS FOR THE MP REGULATORS. WPB | | | AMEND. TO FBC SEC. 107.2.1. | | | 10) THE SIZING TABLE SUBMITTED FOR THE PE PIPE IS FROM | | | AN OUTDATED CODE STANDARD. THERE HAVE BEEN 2 CODE CYLE | | | CHANGES SINCE 2007. SUBMIT COPIES OR REFERNCE THE | | | CORRECT AND UPDATED SIZING TABLES USED FOR THE GAS | | | DESIGN. WPB AMEND. TO FBC SEC. 107.2.1. | | | 11) SHOW THE CORRESPONDING EHD FOR THE CSST PIPE. THE | | | DIFFERENT EHD NUMBER CARRIES DIFFERNT BTU LOADS. | | | 12) SUBMIT COMBUSTION AIR CALCULATIONS FOR THE | | | APPLIANCES. 2014 FBC-R SEC. G2407. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2016-02-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-02-24 |
Time |
17:53 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-02-08 |
Time |
13:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-01-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-01-22 |
Time |
18:56 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-01-08 |
Time |
16:42 |
Sent To |
|
|
| Notes |
| 2016-01-08 16:42:56 | TLARGE'S DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-10-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-10-01 |
Time |
18:53 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-08-12 |
Time |
13:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2016-01-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-01-22 |
Time |
07:53 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-01-22 |
Time |
07:53 |
Sent To |
|
|
| Notes |
| 2016-01-22 07:54:30 | MU 2015-17460 PAID $318.50 | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2015-09-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-09-28 |
Time |
17:57 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-09-28 |
Time |
17:57 |
Sent To |
|
|
| Notes |
| 2015-09-28 17:59:05 | SUBMIT A COPY OF THE PAID IMPACT FEE RECEIPT. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2016-01-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-01-22 |
Time |
17:38 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-01-22 |
Time |
07:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2015-09-29 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-09-29 |
Time |
11:31 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-09-29 |
Time |
07:29 |
Sent To |
|
|
| Notes |
| 2015-09-29 08:09:47 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY MECHANICAL | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) FBC 107.2.1 - INFORMATION ON CONSTRUCTION DOCUMENTS. | | | ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND | | | ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE OF | | | THE PERSON RESPONSIBLE FOR THE DESIGN. THE MECHANICAL | | | PLANS ARE REQUIRED TO HAVE THE NAME, SIGNATURE AND | | | LICENSE NUMBER OF THE PERSON RESPONSIBLE FOR THE | | | DESIGN. | | | | | | 2) THE MODEL NUMBERS AND SPECIFICATIONS FOR THE HEATING | | | AND COOLING EQUIPMENT FOR THE EQUIPMENT SCHEDULE ON THE | | | MECHANICAL PLAN DO NOT CORRESPOND WITH THE EQUIPMENT | | | SIZING CALCULATIONS FOR ZONES #1 AND #3. FBC 107.2.1 | | | | | | 3) THE OWNER/AGENT IS REQUIRED TO SIGN THE ENERGY | | | COMPLIANCE FORMS. FBC ENERGY CONSERVATION R103.1.1.2 | | | | | | 4) THE ENERGY COMPLIANCE FORMS SPECIFY R-20 CEILING | | | INSULATION AND PLAN SHEET A-302 HAS R-19 CEILING | | | INSULATION. FBC 107.2.1 | | | | | | 5) SPECIFY THE LOCATIONS OF THE THREE CONDENSING UNITS | | | ON THE PLANS. FBC 107.2.1 | | | | | | 6) THE LOCATIONS OF THE THREE AIR HANDLERS SHOWN ON | | | ARCHITECTURAL PLAN SHEET A-101 DO NOT MATCH THE | | | LOCATIONS SHOWN ON THE MECHANICAL PLANS. FBC 107.2.1 | | | | | | 7) FBC-R - M1305.1.3 APPLIANCES IN ATTICS. | | | ATTICS CONTAINING APPLIANCES SHALL BE PROVIDED WITH AN | | | OPENING AND A CLEAR AND UNOBSTRUCTED PASSAGEWAY LARGE | | | ENOUGH TO ALLOW REMOVAL OF THE LARGEST APPLIANCE, BUT | | | NOT LESS THAN 30 INCHES (762 MM) HIGH AND 22 INCHES | | | (559 MM) WIDE AND NOT MORE THAN 20 FEET (1829 MM) LONG | | | MEASURED ALONG THE CENTERLINE OF THE PASSAGEWAY FROM | | | THE OPENING TO THE APPLIANCE. THE PASSAGEWAY SHALL HAVE | | | CONTINUOUS SOLID FLOORING IN ACCORDANCE WITH CHAPTER 5 | | | NOT LESS THAN 24 INCHES (610 MM) WIDE. A LEVEL SERVICE | | | SPACE AT LEAST 30 INCHES (762 MM) DEEP AND 30 INCHES | | | (762 MM) WIDE SHALL BE PRESENT ALONG ALL SIDES OF THE | | | APPLIANCE WHERE ACCESS IS REQUIRED. THE CLEAR ACCESS | | | OPENING DIMENSIONS SHALL BE A MINIMUM OF 20 INCHES BY | | | 30 INCHES (508 MM BY 762 MM), AND LARGE ENOUGH TO ALLOW | | | REMOVAL OF THE LARGEST APPLIANCE. | | | | | | 8) FBC-R - M1305.1.3.2 AIR-HANDLING UNITS. | | | 2014 FBC ENERGY CONSERVATION R403.2.4 | | | AIR-HANDLING UNITS SHALL BE ALLOWED IN ATTICS IF THE | | | FOLLOWING CONDITIONS ARE MET: | | | 1. THE SERVICE PANEL OF THE EQUIPMENT IS LOCATED WITHIN | | | 6 FEET (1829 MM) OF AN ATTIC ACCESS. | | | 2. A DEVICE IS INSTALLED TO ALERT THE OWNER OR SHUT THE | | | UNIT DOWN WHEN THE CONDENSATION DRAIN IS NOT WORKING | | | PROPERLY. | | | 3. THE ATTIC ACCESS OPENING IS OF SUFFICIENT SIZE TO | | | REPLACE THE AIR HANDLER. | | | 4. A NOTICE IS POSTED ON THE ELECTRIC SERVICE PANEL | | | INDICATING TO THE HOMEOWNER THAT THE AIR HANDLER IS | | | LOCATED IN THE ATTIC. | | | | | | 9) FBC-R - M1305.1.3.1 ELECTRICAL REQUIREMENTS. | | | A LUMINAIRE CONTROLLED BY A SWITCH LOCATED AT THE | | | REQUIRED PASSAGEWAY OPENING AND A RECEPTACLE OUTLET | | | SHALL BE INSTALLED AT OR NEAR THE APPLIANCE LOCATION IN | | | ACCORDANCE WITH CHAPTER 34. | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2016-02-16 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-02-16 |
Time |
06:16 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-02-16 |
Time |
03:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2016-01-13 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-01-13 |
Time |
09:12 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-01-13 |
Time |
09:10 |
Sent To |
|
|
| Notes |
| 2016-01-13 09:12:12 | 1)SUBMIT A SANITARY RISER DIAGRAM FOR THE PLUMBING | | | SYSTEM FOR THE NEW STRUCTURE. WPB AMEND. TO FBC SEC. | | | 107.3.5.3. | | | 2) THE PLANS SHOW 4 AREA DRAINS. WHERE DO THEY | | | DISCARGE? IS THERE AN EXFILTRATION TRENCH? IF SO, | | | SUBMIT A DETAIL FOR THE EXFILTRATION TRENCH. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2015-08-21 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-08-21 |
Time |
02:27 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-08-21 |
Time |
01:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2015-08-25 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2015-08-25 |
Time |
08:55 |
Rev Time |
|
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2015-08-25 08:56:53 | 8/25/15 | | | | | | SEPARATE PERMITS AND PLANS REQUIRED FOR LANDSCAPING AND | | | DRIVEWAY. | | 2015-08-17 11:29:01 | 8/17/15 |
|
|