Plan Review Details - Permit 15080379
Plan Review Stops For Permit 15080379
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-10-28 Cont ID  
Sent By jgomez Date 2015-10-28 Time 09:24 Rev Time 0.00
Received By jgomez Date 2015-10-28 Time 09:24 Sent To  
Notes
2015-10-28 09:24:43 
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-09-28 Cont ID  
Sent By jgomez Date 2015-09-25 Time 11:01 Rev Time 0.00
Received By jgomez Date 2015-09-25 Time 10:28 Sent To  
Notes
2015-09-25 11:25:32SINGLE FAMILY RESIDENCE (R3) BUILDING REVIEW COMMENTS.
 CODE: FBC 5TH EDITION (2014).
  
 1- ARCHITECT TO UPDATE ALL PLANS AND NOTES. THE CODE IN
 EFFECT IS THE 2014 CODE NOT THE 2010. REVISE AS
 REQUIRED. CHAPTER 553 F.S.
  
 2- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH
 COUNTY (2300 N. JOG RD) FOR IMPACT FEES ASSESSMENT.
 BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID
 RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF
 THE UNIFIED LAND DEVELOPMENT CODE.
  
 3- EXTERIOR WALL SECTION ON SHEET 2 OF 2:
 A) SPECIFY VENTILATION AS REQUIRED BY SEC. R806 OF
 FBC-RESIDENTIAL, 5TH EDITION (2014). SPECIFY SIZE AND
 SPACING OF VENTS.
 NOTE: KEEP IN CONSIDERATION RIGID VENT PRODUCT APPROVAL
 SUBMITTED.
  
 B) SPECIFY THE 6 INCHES HEIGHT ABOVE THE FINISHED GRADE
 AS REQUIRED BY SEC. R404.1.6 OF FBC-RESIDENTIAL, 5TH
 EDITION (2014).
 NOTE: KEEP IN CONSIDERATION THE 3/4" RECESS AND THE
 SIZE OF FOOTING SPECIFIED. ALSO REMEMBER THAT 12" IS
 REQUIRED TO BE BELOW THE FINISH GRADE.
  
 C) PROVIDE ROOF SHEATHING NAILING SPECIFICATIONS.
 SPECIFY NAIL TYPE (8D RING SHANK MIN.) AND SPACING AS
 REQUIRED BY SEC. R803.2.3.1 OF FBC-RESIDENTIAL, 5TH
 EDITION (2014).
  
 D) SPECIFY THE STUCCO THICKNESS AS REQUIRED BY TABLE
 R702.1(1) OF FBC-RESIDENTIAL, 5TH EDITION (2014).
  
 E) SPECIFY WALL SHEATHING NAIL TYPE AND SPACING. SEC.
 R301 OF FBC-RESIDENTIAL, 5TH EDITION (2014)
  
 4- DOOR #8 SHOWN ON FLOOR PLAN AND WEST ELEVATION DON'T
 MATCH DOOR SPECIFIED ON THE DOOR SCHEDULE ON SHEET 1 OF
 2. SEE NUMBER OF PANELS AND REVISE AS REQUIRED TO
 MATCH. SEC. 107.2.1 CITY AMENDMENTS.
  
 5- SPECIFY THE DIMENSION FOR THE ROOF OVERHANG AND
 PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE
 FIRE RATING OVERHANG AS REQUIRED BY TABLE R302.1(1) OF
 FBC-RESIDENTIAL, 5TH EDITION (2014).
  
 6- PROVIDE COMPLETE FRAMING DETAILS AND SPECIFICATIONS
 FOR ALL NEW WINDOWS AND DOORS OPENINGS. SPECIFY ALL
 FRAMING MEMBERS AND FASTENERS. SEC. R301 OF
 FBC-RESIDENTIAL, 5TH EDITION (2014).
  
 7- PROVIDE THE DESIGN PRESSURES FOR ALL EXTERIOR DOORS.
 ONLY THE WINDOWS DESIGN PRESSURES WERE GIVEN. SEC. R301
 OF FBC-RESIDENTIAL, 5TH EDITION (2014).
  
 8- ROOF FRAMING PLAN. SPECIFY ALL TRUSS CONNECTORS,
 INCLUDING THE CONNECTORS TO TRUSSES RESTING ON EXISTING
 ROOF SHEATHING. SEC. R301 OF FBC-RESIDENTIAL, 5TH
 EDITION (2014).
  
 9- ENERGY CALCULATIONS SUBMITTED TO HAVE THE
 OWNER/AGENT CERTIFICATION AND DATE AT THE BOTTOM OF THE
 FORM AS REQUIRED BY SEC. R103.1.1.2 OF FBC-ENERGY
 CONSERVATION, 5TH EDITION (2014).
 IMPORTANT: WINDOWS AND DOORS LABELS WITH U-FACTOR AND
 SHGC FACTOR SPECIFIED ON THIS ENERGY CALCULATIONS WILL
 BE REQUIRED.
  
 10- THERE ARE TWO DIFFERENT PRODUCT APPROVALS SUBMITTED
 FOR THE EXTERIOR SWING DOORS. FL15227.5 AND FL15446-R3.
 PROVIDE ONLY ONE PRODUCT APPROVAL THAT MATCHES DOOR AS
 SPECIFIED ON THE DOOR SCHEDULE. SEC. 107.2.1 CITY
 AMENDMENTS.
 NOTE: CLEARLY MARK ON PRODUCT APPROVAL ENTRY DOOR,
 MASTER BEDROOM DOOR, ETC.
  
 11- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.002(33) FOR:
 A) SLIDING GLASS DOOR #8 AS SHOWN ON PLANS AND DOOR
 SCHEDULE. NOTE: SEE NUMBER OF PANELS.
  
 B) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON ROOF
 FRAMING PLANS AND DETAILS. PROVIDE ONLY THE FLORIDA
 PRODUCT APPROVAL COVER PAGE AND PAGE SHOWING THE
 SPECIFIED CONNECTOR. OR DESIGN PROFESSIONAL TO LIST THE
 FLORIDA PRODUCT APPROVAL NEXT TO THE SPECIFIED
 CONNECTOR.
  
 12- DESIGNER OF RECORD TO APPROVE IN WRITING ALL
 PRODUCT APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY
 AMENDMENTS.
  
 13- ARCHITECT TO CLARIFY BEDROOMS CASEMENT WINDOWS.
 ARCHITECT'S EXTERIOR ELEVATIONS SHOW DOUBLE CASEMENT
 WINDOWS ON EACH OPENING. DOUBLE CASEMENT WINDOWS DON'T
 COMPLY WITH THE EGRESS REQUIREMENTS (SEC. R310) BECAUSE
 A MULLION IS REQUIRED IN THE MIDDLE TO RESIST THE WIND
 LOADS.
 ON THE OTHER HAND CASEMENT WINDOWS NOA 14-0506.01
 SUBMITTED IS FOR SINGLE CASEMENT WINDOWS ONLY. REVISE
 AS REQUIRED TO COMPLY WITH EGRESS AND PRODUCT APPROVAL
 SUBMITTED.
  
 *** PLEASE PROVIDE A RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2015-10-31 Cont ID  
Sent By skennedy Date 2015-10-31 Time 09:25 Rev Time 0.00
Received By skennedy Date 2015-10-31 Time 09:25 Sent To  
Notes
2015-10-28 13:40:44NEW DRAWING SUBMITTED. JG.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2015-09-29 Cont ID  
Sent By skennedy Date 2015-09-29 Time 17:42 Rev Time 0.00
Received By skennedy Date 2015-09-29 Time 17:42 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2015-10-26 Cont ID  
Sent By fmittner Date 2015-10-26 Time 10:04 Rev Time 0.00
Received By fmittner Date 2015-10-26 Time 10:04 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2015-08-21 Cont ID  
Sent By fmittner Date 2015-08-21 Time 16:44 Rev Time 0.00
Received By fmittner Date 2015-08-21 Time 16:44 Sent To  
Notes
2015-08-21 16:47:01SIGNIFICANT ADDITIONS IN HISTORIC DISTRICTS REQUIRES
 APPROVAL BY HPB. LEFT MESSAGE WITH DAN. QUESTIONS
 CONTACT FRIEDERIKE MITTNER AT 822-1457.
2015-08-17 11:27:268/17/15

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-10-28 Cont ID  
Sent By jgomez Date 2015-10-28 Time 13:30 Rev Time 0.00
Received By jgomez Date 2015-10-21 Time 09:47 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-09-29 Cont ID  
Sent By skennedy Date 2015-09-29 Time 17:43 Rev Time 0.00
Received By skennedy Date 2015-08-11 Time 16:18 Sent To  
Notes
2015-08-11 16:18:56R29

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status P Date 2015-11-03 Cont ID  
Sent By ndaniels Date 2015-11-03 Time 13:19 Rev Time 0.00
Received By ndaniels Date   Time   Sent To  
Notes
2015-11-03 13:19:28PER SAK, OKAY TO PASS IMPACT REVIEW

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2015-10-28 Cont ID  
Sent By jgomez Date 2015-10-28 Time 09:39 Rev Time 0.00
Received By jgomez Date 2015-10-28 Time 09:39 Sent To  
Notes
2015-10-28 09:40:20PROVIDE COPY OF PAID IMPACT FEES. $180.65.
 MU-2015-25026.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2015-09-25 Cont ID  
Sent By jgomez Date 2015-09-25 Time 16:47 Rev Time 0.00
Received By jgomez Date 2015-09-25 Time 16:47 Sent To  
Notes
2015-09-25 16:47:591- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH
 COUNTY (2300 N. JOG RD) FOR IMPACT FEES ASSESSMENT.
 BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID
 RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF
 THE UNIFIED LAND DEVELOPMENT CODE.
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2015-10-28 Cont ID  
Sent By jgomez Date 2015-10-28 Time 12:21 Rev Time 0.00
Received By jgomez Date 2015-10-28 Time 12:21 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2015-09-28 Cont ID  
Sent By jgomez Date 2015-09-28 Time 18:58 Rev Time 0.00
Received By jgomez Date 2015-09-28 Time 18:58 Sent To  
Notes
2015-09-28 19:03:29NEW SINGLE FAMILY RESIDENCE (R3) MECHANICAL REVIEW
 COMMENTS.
 CODE: FBC 5TH EDITION (2014).
  
 1- EQUIPMENT SIZING CALCULATIONS NEED TO BE DONE TO THE
 ACTUAL BUILDING ORIENTATION AS REQUIRED BY SEC. R403.61
 OF FBC-ENERGY CONSERVATION, 5TH EDITION (2014).
 ACCORDING TO CALCULATIONS SUBMITTED THE ENTRY DOOR IS
 FACING NORTH. THIS I S NOT CORRECT. REVISE CALCULATIONS
 AS REQUIRED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]

Review Stop P PLUMBING
Rev No 2 Status P Date 2015-10-28 Cont ID  
Sent By gjohnson Date 2015-10-28 Time 15:27 Rev Time 0.00
Received By gjohnson Date 2015-10-28 Time 15:27 Sent To  
Notes
2015-10-28 13:40:53NEW DRAWING SUBMITTED. JG.

Review Stop P PLUMBING
Rev No 1 Status P Date 2015-08-26 Cont ID  
Sent By gjohnson Date 2015-08-26 Time 15:48 Rev Time 0.00
Received By gjohnson Date 2015-08-26 Time 15:48 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2015-09-28 Cont ID  
Sent By jgomez Date 2015-09-28 Time 19:08 Rev Time 0.00
Received By jgomez Date 2015-09-28 Time 19:08 Sent To  
Notes
2015-09-28 19:10:071- SHINGLES NOA 14-1022.20.
  
 2- RIGID VENT NOA 14-1022.11.
  
 3- UNDERLAYMENT NOA 13-1104.11.
  

Review Stop Z ZONING
Rev No 2 Status P Date 2015-10-26 Cont ID  
Sent By fmittner Date 2015-10-26 Time 10:04 Rev Time 0.00
Received By fmittner Date 2015-10-26 Time 10:04 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2015-09-29 Cont ID  
Sent By fmittner Date 2015-08-21 Time 16:47 Rev Time 0.00
Received By fmittner Date 2015-09-29 Time 17:42 Sent To  
Notes
***NONE***