| Plan Review Stops For Permit 15080304 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2016-05-13 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2016-05-13 |
Time |
17:01 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2016-05-13 |
Time |
17:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2015-12-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-12-29 |
Time |
09:21 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-12-29 |
Time |
09:18 |
Sent To |
|
|
| Notes |
| 2015-12-29 09:18:47 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT:15080304 | | | ADD: 2100 45TH ST. | | | CONT: TBD/ TO BE DETERMINED | | | TEL: (???)???-???? | | | E-MAIL:???????????????? | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION, | | | | | | 4TH REVIEW | | | DATE: TUES. DEC. 29/ 2015 | | | ACTION: DENIED | | | | | | | | | 1) 4TH REQUEST. THE UNDERGROUND STORAGE TANKS AND | | | INSTALATION OF UNDERGROUND PIPING AND 6 NEW DISPENSERS | | | WILL REQUIRE A PCP CONTRATOR SIGNED ON TO VERIFY | | | LICENSURE BEFORE PERMIT ISSUANCE. FL. S. 489.105(P) | | | ALSO SEE F. S. 376.303. UNLESS THE PCP CONTRACTOR HOLDS | | | A SECOND LICENSE FOR THE CANOPY, ANOTHER CONTRACTOR | | | WILL BE REQUIRED TO SIGN ONTO THE PERMIT APPLICATION. | | | | | | 2-7) COMPLIED. | | | | | | 8 ) 4TH REQUEST .BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY. | | | THE ACTUAL PERMIT SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE | | | PERMIT APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 9) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2015-11-10 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-11-10 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-11-10 |
Time |
15:26 |
Sent To |
|
|
| Notes |
| 2015-11-10 15:56:59 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT:15080304 | | | ADD: 2100 45TH ST. | | | CONT: TBD/ TO BE DETERMINED | | | TEL: (???)???-???? | | | E-MAIL:???????????????? | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION, | | | | | | 2ND REVIEW | | | DATE: FRI. OCT. 16/ 2015 | | | ACTION: DENIED | | | | | | ) NOTICE!!!!!!!!!!!!! CHAPTER 553.80(2)(B) FLORIDA | | | STATUTES STATES THAT A LOCAL GOVERNMENT SHALL IMPOSE A | | | FEE OF FOUR TIMES THE FEE FOR PLAN REVIEW, IF PLANS ARE | | | REJECTED (3) OR MORE TIMES FOR REPEATED FAILURE TO | | | CORRECT A CODE VIOLATION. | | | | | | 1)3RD REQUEST. THE UNDERGROUND STORAGE TANKS AND | | | INSTALATION OF UNDERGROUND PIPING AND 6 NEW DISPENSERS | | | WILL REQUIRE A PCP CONTRATOR SIGNED ON TO VERIFY | | | LICENSURE BEFORE PERMIT ISSUANCE. FL. S. 489.105(P) | | | ALSO SEE F. S. 376.303. UNLESS THE PCP CONTRACTOR HOLDS | | | A SECOND LICENSE FOR THE CANOPY, ANOTHER CONTRACTOR | | | WILL BE REQUIRED TO SIGN ONTO THE PERMIT APPLICATION. | | | | | | 2) COMPLIED. NOTE 2 PERMITS WERE APPIED FOR 15080304 | | | UNDERGOUND STORAGE TANKS AND 15080306 A 3,096 SQ. FT | | | CANOPY. NOTE ONLY 2 SETS OF PLANS WERE SUBMITTED. | | | PLEASE NOTE ONLY SHEET G8 SHOWS ELEVATION OF THE | | | CANOPY, NO DETAILS, STURTURAL SHEETS NOR WIND DESIGN | | | WAS INCLUDED. 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR | | | BUILDINGS. IF THE DETAILS FOR TTHE CANOPY ARE TO BE | | | INCORPORATED INTO ONE SET OF PLANS, THEN 4 SETS OF | | | PLANS WILL BE REQUIRED. 2 SETS FOR EACH PERMIT. | | | | | | 3-6) COMPLIED. | | | | | | 7) 3RD REQUEST. ONLY (1) SOILS REPORT SUBMITED, (2 ) | | | WILL BE REQUIRED FOR THE UNDERGROUND TANKS AND (2) FOR | | | THE CANOPY. THE SOILS REPORT INDICATES THERE TO BE | | | UNDER LAYING ORGANIC SOILS. THE SOILS REPORT IS | | | SUGESTIONSAND ALTERNATIVES IN DEALING WITH THIS MATTER. | | | THE DESIGNER OF RECORD HAS NOT RESPONDED AS TO HOW THE | | | ORGANIC SOILS ARE TO BE DELT WITH. | | | | | | THE (2) ISSUE IS THAT GROUND WATER WILL BE PRESENT | | | AROUND 7 FEET BELOW GRADE, PLEASE PROVIDE HOW THE | | | GROUND WATER WILL BE LOWERED TO BE ABLE TO WORK AT THE | | | REQUIRED DEEPER ELEVATION FROM GRADE. | | | | | | SHEET G1 INDICATES THE TANKS TO BE 10 FT. DIAMETER AND | | | APPROXIMATELY 15 FEET BELOW GRADE. TO DATE THERE HAS | | | BEEN NO SOILS REPORT SUBMITTED AS TO THE WATER TABLE | | | LEVEL, AND HOW OR IF DEWATERING WILL BE REQUIRED AT | | | THIS SITE SINCE THERE IS A CANAL JUST WEST OF THIS | | | PROPERTY. | | | 2014 FBC-B 1803.3 BASIS OF SOILS INVESTIGATION. | | | | | | 8 ) 3RD REQUEST) .BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY. | | | THE ACTUAL PERMIT SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE | | | PERMIT APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 9) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2015-10-16 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-10-16 |
Time |
12:45 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-10-16 |
Time |
12:01 |
Sent To |
|
|
| Notes |
| 2015-10-16 12:21:29 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT:15080304 | | | ADD: 2100 45TH ST. | | | CONT: TBD/ TO BE DETERMINED | | | TEL: (???)???-???? | | | E-MAIL:???????????????? | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION, | | | | | | 2ND REVIEW | | | DATE: FRI. OCT. 16/ 2015 | | | ACTION: DENIED | | | | | | ) NOTICE!!!!!!!!!!!!! CHAPTER 553.80(2)(B) FLORIDA | | | STATUTES STATES THAT A LOCAL GOVERNMENT SHALL IMPOSE A | | | FEE OF FOUR TIMES THE FEE FOR PLAN REVIEW, IF PLANS ARE | | | REJECTED (3) OR MORE TIMES FOR REPEATED FAILURE TO | | | CORRECT A CODE VIOLATION. | | | | | | 1)2ND REQUEST. THE UNDERGROUND STORAGE TANKS AND | | | INSTALATION OF UNDERGROUND PIPING AND 6 NEW DISPENSERS | | | WILL REQUIRE A PCP CONTRATOR SIGNED ON TO VERIFY | | | LICENSURE BEFORE PERMIT ISSUANCE. FL. S. 489.105(P) | | | ALSO SEE F. S. 376.303. UNLESS THE PCP CONTRACTOR HOLDS | | | A SECOND LICENSE FOR THE CANOPY, ANOTHER CONTRACTOR | | | WILL BE REQUIRED TO SIGN ONTO THE PERMIT APPLICATION. | | | | | | 2) COMPLIED. NOTE 2 PERMITS WERE APPIED FOR 15080304 | | | UNDERGOUND STORAGE TANKS AND 15080306 A 3,096 SQ. FT | | | CANOPY. NOTE ONLY 2 SETS OF PLANS WERE SUBMITTED. | | | PLEASE NOTE ONLY SHEET G8 SHOWS ELEVATION OF THE | | | CANOPY, NO DETAILS, STURTURAL SHEETS NOR WIND DESIGN | | | WAS INCLUDED. 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR | | | BUILDINGS. IF THE DETAILS FOR TTHE CANOPY ARE TO BE | | | INCORPORATED INTO ONE SET OF PLANS, THEN 4 SETS OF | | | PLANS WILL BE REQUIRED. 2 SETS FOR EACH PERMIT. | | | | | | 3) 2ND REQUEST. RESPONSE INDICATES THE PLANS WERE | | | SUBMITTED TO DERM ELECTRONICALLY PLEASE SHOW APPROVAL. | | | THE UNDERGROUND STORAGE TANKS WILL NEED TO BE REVIEWED | | | BY P. B. C. DEPARTMENT OF ENVIROMENTAL RESOURSES | | | MANAGEMENT FOR REVIEW AND APPROVAL, PLANS STAMPED BY | | | THE AGENCY AND RETURNED FOR REVIEW BY THE CITY BUILDING | | | DEPARTMENT. 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR | | | BUILDINGS.12. ENVIROMENTAL REQUIREMENTS. | | | | | | 4) COMPLIED. THE LISTED FAMILY OF CODES LIST THE 2010 | | | FBC AS THE CODE THE DOCUMENTS WERE DESIGNED TOO. PLEASE | | | UPDATE THE PLANS TO THE 2014 5TH EDITION OF THE FLORIDA | | | BUILDING CODE, ADOPTED STATWIDE ON JUNE 30/ 2015. | | | | | | 5) COMPLIED. | | | | | | 6) COMPLIED | | | | | | 7) 2ND REQUEST. ONLY (1) SOILS REPORT SUBMITED, (2 ) | | | WILL BE REQUIRED FOR THE UNDERGROUND TANKS AND (2) FOR | | | THE CANOPY. THE SOILS REPORT INDICATES THERE TO BE | | | UNDER LAYING ORGANIC SOILS. THE SOILS REPORT IS | | | SUGESTIONSAND ALTERNATIVES IN DEALING WITH THIS MATTER. | | | THE DESIGNER OF RECORD HAS NOT RESPONDED AS TO HOW THE | | | ORGANIC SOILS ARE TO BE DELT WITH. | | | | | | THE (2) ISSUE IS THAT GROUND WATER WILL BE PRESENT | | | AROUND 7 FEET BELOW GRADE, PLEASE PROVIDE HOW THE | | | GROUND WATER WILL BE LOWERED TO BE ABLE TO WORK AT THE | | | REQUIRED DEEPER ELEVATION FROM GRADE. | | | | | | SHEET G1 INDICATES THE TANKS TO BE 10 FT. DIAMETER AND | | | APPROXIMATELY 15 FEET BELOW GRADE. TO DATE THERE HAS | | | BEEN NO SOILS REPORT SUBMITTED AS TO THE WATER TABLE | | | LEVEL, AND HOW OR IF DEWATERING WILL BE REQUIRED AT | | | THIS SITE SINCE THERE IS A CANAL JUST WEST OF THIS | | | PROPERTY. | | | 2014 FBC-B 1803.3 BASIS OF SOILS INVESTIGATION. | | | | | | 8 ) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 9) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A | | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | | THIS REVIEW. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-08-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-08-24 |
Time |
09:34 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-08-24 |
Time |
07:30 |
Sent To |
|
|
| Notes |
| 2015-08-24 08:21:54 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT:15080304 | | | ADD: 2100 45TH ST. | | | CONT: TBD/ TO BE DETERMINED | | | TEL: (???)???-???? | | | E-MAIL:???????????????? | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION, | | | | | | 1ST REVIEW | | | DATE: MON. AUGUST 24/ 2015 | | | ACTION: DENIED | | | | | | 1) THE UNDERGROUND STORAGE TANKS AND INSTALATION OF | | | UNDERGROUND PIPING AND 6 NEW DISPENSERS WILL REQUIRE A | | | PCP CONTRATOR SIGNED ON TO VERIFY LICENSURE BEFORE | | | PERMIT ISSUANCE. FL. S. 489.105(P) ALSO SEE F. S. | | | 376.303. UNLESS THE PCP CONTRACTOR HOLDS A SECOND | | | LICENSE FOR THE CANOPY, ANOTHER CONTRACTOR WILL BE | | | REQUIRED TO SIGN ONTO THE PERMIT APPLICATION. | | | | | | 2) NOTE 2 PERMITS WERE APPIED FOR 15080304 UNDERGOUND | | | STORAGE TANKS AND 15080306 A 3,096 SQ. FT CANOPY. NOTE | | | ONLY 2 SETS OF PLANS WERE SUBMITTED. PLEASE NOTE ONLY | | | SHEET G8 SHOWS ELEVATION OF THE CANOPY, NO DETAILS, | | | STURTURAL SHEETS NOR WIND DESIGN WAS INCLUDED. 107.3.5 | | | MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. IF THE | | | DETAILS FOR TTHE CANOPY ARE TO BE INCORPORATED INTO ONE | | | SET OF PLANS, THEN 4 SETS OF PLANS WILL BE REQUIRED. 2 | | | SETS FOR EACH PERMIT. | | | | | | 3) THE UNDERGROUND STORAGE TANKS WILL NEED TO BE | | | REVIEWED BY P. B. C. DEPARTMENT OF ENVIROMENTAL | | | RESOURSES MANAGEMENT FOR REVIEW AND APPROVAL, PLANS | | | STAMPED BY THE AGENCY AND RETURNED FOR REVIEW BY THE | | | CITY BUILDING DEPARTMENT. 107.3.5 MINIMUM PLAN REVIEW | | | CRITERIA FOR BUILDINGS.12. ENVIROMENTAL REQUIREMENTS. | | | | | | 4) THE LISTED FAMILY OF CODES LIST THE 2010 FBC AS THE | | | CODE THE DOCUMENTS WERE DESIGNED TOO. PLEASE UPDATE THE | | | PLANS TO THE 2014 5TH EDITION OF THE FLORIDA BUILDING | | | CODE, ADOPTED STATWIDE ON JUNE 30/ 2015. | | | | | | 5) SHEET G1 PROVIDES THE DEAD WEIGHT DESIGN FOR THE USE | | | OF THE DEAD MEN FOR EACH TANK, THE CENTER DEAD MAN CAN | | | NOT BE SHARED AS DEPICTED. THE DESIGN OF THE DEADMAN IS | | | 18 INCHES WIDE, 8.75 INCHES IN HEIGHT AND 36 FEET LONG. | | | PLEASE PROVIDE IF THIS IS A PRECAST UNIT OR IS THIS | | | POURED IN PLACE? IF PRE-CAST IS THERE STEEL REBAR | | | ENCASED ? IF POURED IS THERE TO BE STEEL | | | RE-INFORCEMENT? IS THERE ANCHOR PROTRUDING FROM THE | | | DEADMEN? 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 6) SHEET G3 NOTE # 4 INDICATES THE USE OF MOH STRAP | | | ANCHOR SYSTEM TO BE SUPPLIED BY THE TANK MANUFACTURER | | | AND THE DEAD MEN ARE TO BE PLACED PER THE MANUFACTURERS | | | INSTALLATION INSTRUCTION, PLEASE SUBMIT BOTH THE MOH | | | STRAP ANCHOR SYSTEM AS WELL AS THE DEAD MEN INSTALATION | | | INSTRUCTIONS. THE MOH SYSTEM WILL NEED TO INDICATE THE | | | TYPE OF STRAPS, CENTER TO CENTER PLACEMENT AND HOW THEY | | | ARE ATTACHED TO THE DEADMEN. 107.3.5 MINIMUM PLAN | | | REVIEW CRITERIA FOR BUILDINGS. .12. ENVIROMENTAL | | | REQUIREMENTS. | | | | | | 7) SHEET G1 INDICATES THE TANKS TO BE 10 FT. DIAMETER | | | AND APPROXIMATELY 15 FEET BELOW GRADE. TO DATE THERE | | | HAS BEEN NO SOILS REPORT SUBMITTED AS TO THE WATER | | | TABLE LEVEL, AND HOW OR IF DEWATERING WILL BE REQUIRED | | | AT THIS SITE SINCE THERE IS A CANAL JUST WEST OF THIS | | | PROPERTY. | | | 2014 FBC-B 1803.3 BASIS OF SOILS INVESTIGATION. | | | | | | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 9) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A | | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | | THIS REVIEW. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2016-02-25 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2016-02-25 |
Time |
18:03 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2016-02-25 |
Time |
17:31 |
Sent To |
I |
|
| Notes |
| 2016-02-25 18:05:21 | THIS WAS ALREADY REVIEWED AND APPROVED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2015-10-19 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-10-19 |
Time |
17:46 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-10-19 |
Time |
17:04 |
Sent To |
I |
|
| Notes |
| 2015-10-19 17:51:14 | THE SCOPE OF THIS REVIEW IS LIMITED ONLY TO THE | | | ELECTRIC FOR THE DISPENSING STATIONS AND NOT ANY PART | | | OF THE STORE. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2015-12-10 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2015-12-10 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2015-12-10 |
Time |
16:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2015-10-08 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2015-10-08 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2015-10-08 |
Time |
15:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2015-08-18 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2015-08-18 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2015-08-18 |
Time |
16:38 |
Sent To |
|
|
| Notes |
| 2015-08-18 17:05:02 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | 1) SHEET GO, THERE ARE INCORRECT REFERENCES TO THE FIRE | | | CODE. | | | | | | THE PROPOSED PROJECT SHALL MEET THE REQUIREMENTS OF THE | | | 5TH EDITION OF FLORIDA FIRE PREVENTION CODE INCLUDING | | | THE 2012 EDITION OF NFPA 1 AND NFPA 101 AND ALL OTHER | | | APPLICABLE CODES OR STANDARDS. | | | FLAMMABLE AND COMBUSTIBLE LIQUIDS SHALL COMPLY WITH | | | NFPA 30, 2012 EDITION | | | MOTOR FUEL DISPENSING FACILITIES AND REPAIR GARAGES | | | SHALL COMPLY WITH NFPA 30 A, 2012 EDITION | | | CONSTRUCTION WORK SHALL COMPLY WITH THE REQUIREMENTS OF | | | NFPA 241, 2009 EDITION. | | | FIRE EXTINGUISHERS SHALL COMPLY WITH THE REQUIREMENTS | | | OF NFPA 10, 2010 EDITION. | | | ELECTRIC WORK SHALL COMPLY WITH NFPA 70, 2011 EDITION. | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2016-06-06 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2016-06-06 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2016-05-03 |
Time |
09:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2016-02-26 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2016-02-26 |
Time |
08:27 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2015-12-08 |
Time |
14:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2015-11-17 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-11-17 |
Time |
12:54 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-11-02 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-10-19 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-10-19 |
Time |
17:48 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-09-28 |
Time |
08:26 |
Sent To |
|
|
| Notes |
| 2015-10-19 17:50:10 | 10/19/15 PASSED ELECTRICAL & FIRE REVIEWS BUT FAILED | | | EVERY OTHER. CONTACT NOTIFIED VIA PHONE CALL. SENT TO | | | LARGE DENIED BIN "TBD". MA |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-08-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-08-24 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-08-10 |
Time |
14:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
6 |
Status |
P |
Date |
2016-06-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-06-20 |
Time |
06:42 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-06-20 |
Time |
06:21 |
Sent To |
|
|
| Notes |
| 2016-06-20 06:42:46 | 6/20/2016 | | | PALM BEACH COUNTY IMPACT FEES | | | UNDER GROUND STORAGE TANKS & 12 FUELING PUMPS | | | MU-2016-14118 | | | $121,342.76 | | 2016-06-17 12:37:50 | JWITMER'S DESK |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
5 |
Status |
F |
Date |
2016-05-18 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-05-18 |
Time |
12:49 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-05-18 |
Time |
12:49 |
Sent To |
|
|
| Notes |
| 2016-05-18 12:50:13 | IMPACT FEES | | | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
4 |
Status |
F |
Date |
2015-12-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-12-29 |
Time |
09:20 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-12-29 |
Time |
09:20 |
Sent To |
|
|
| Notes |
| 2015-12-29 09:21:31 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
F |
Date |
2015-11-10 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-11-10 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-11-10 |
Time |
15:57 |
Sent To |
|
|
| Notes |
| 2015-11-10 15:58:14 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2015-10-16 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-10-16 |
Time |
12:05 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-10-16 |
Time |
12:05 |
Sent To |
|
|
| Notes |
| 2015-10-16 12:05:53 | IMPACT FEES | | | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2015-08-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-08-24 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-08-24 |
Time |
09:59 |
Sent To |
|
|
| Notes |
| 2015-08-24 10:00:04 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2016-05-11 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-05-10 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-05-10 |
Time |
09:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2015-12-29 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-12-29 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-12-29 |
Time |
11:33 |
Sent To |
|
|
| Notes |
| 2015-12-29 11:34:15 | 3RD REVIEW: FBC 2014 MECHANICAL | | | PERMIT #15080304 | | | 12/29/15 | | | | | | 1) 3RD REQUEST FOR PLANS REVIEWED AND APPROVED BY THE | | | PALM BEACH COUNTY DEPARTMENT OF ENVIRONMENTAL RESOURCES | | | MANAGEMENT. PROVIDE TWO SETS OF PLANS STAMPED AND | | | SIGNED OFF BY THE DEPARTMENT. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2015-11-16 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-11-16 |
Time |
13:34 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-11-16 |
Time |
13:34 |
Sent To |
|
|
| Notes |
| 2015-11-16 13:50:29 | PROVISOS | | | PERMIT #15080304 | | | 11/16/15 | | | | | | 1) A PERMIT APPLICATION MUST BE SUBMIITTED BY A FLORIDA | | | LICENSED POLLUTION CONTROL CONTRACTOR FOR INSTALLATION | | | OF THE UNDERGROUND TANKS AND FUEL DISPENSER SYSTEM. | | | 2) A DEWATERING PLAN MUST BE SUBMITTED PRIOR TO PERMIT | | | ISSUANCE. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2015-10-16 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-10-16 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-10-16 |
Time |
14:26 |
Sent To |
|
|
| Notes |
| 2015-10-16 14:35:01 | 2ND REVIEW: FBC 2014 MECHANICAL | | | PERMIT #15080304 | | | 10/16/15 | | | | | | 1) 2ND REQUEST FOR PLANS REVIEWED AND APPROVED BY THE | | | PALM BEACH COUNTY DEPARTMENT OF ENVIRONMENTAL RESOURCES | | | MANAGEMENT. PROVIDE TWO SETS OF PLANS STAMPED AND | | | SIGNED OFF BY THE DEPARTMENT. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2015-08-19 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-08-19 |
Time |
16:16 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-08-19 |
Time |
16:16 |
Sent To |
|
|
| Notes |
| 2015-08-19 17:03:26 | 1ST REVIEW: FBC 2014 MECHANICAL | | | PERMIT #15080304 | | | 8/19/15 | | | | | | 1) SHEET G0: THE FLORIDA CODES LISTED UNDER PROJECT | | | DATA ARE OUTDATED. THE FLORIDA BUILDING CODE FIFTH | | | EDITION 2014 WENT INTO EFFECT ON JUNE 30, 2015. PLEASE | | | REVIEW AND UPDATE THE REFERENCES. | | | 2) THE PLANS AND SPECIFICATIONS MUST BE REVIEWED AND | | | APPROVED BY THE PALM BEACH COUNTY DEPARTMENT OF | | | ENVIRONMENTAL RESOURCES MANAGEMENT AGENCY. PLEASE RE- | | | SUBMIT PLANS WITH DEPARTMENT APPROVAL STAMPS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
N |
Date |
2016-05-11 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-05-11 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-05-11 |
Time |
10:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2015-12-19 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-12-19 |
Time |
08:28 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-12-19 |
Time |
07:58 |
Sent To |
|
|
| Notes |
| 2015-12-19 08:24:08 | THIS PROJECT WILL REQUIRE APPROVAL FROM THE PALM BEACH | | | COUNTY DEPARTMENT OF ENVIRONMENTAL RESOURCE MANAGEMENT. | | | SUBMIT VERIFICATION THAT THE PLANS HAVE BEEN REVIEWED | | | AND APPROVED BY THAT DEPARTMENT. WPB AMEND. TO FBC SEC. | | | 107.2.1. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2015-11-17 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-11-17 |
Time |
12:54 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-11-17 |
Time |
12:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2015-10-05 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-10-05 |
Time |
10:56 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-10-05 |
Time |
05:45 |
Sent To |
|
|
| Notes |
| 2015-10-05 10:48:57 | 1) SHT. CS2- DETAIL A - SEC. 1108.3 OF THE 2014 | | | FBC-PLUMBING NOTES "SCUPPERS SHALL NOT HAVE AN OPENING | | | LESS THAN 4 INCHES." THE DETAIL SHOWS THE SCUPPER WITH | | | A DIMENSION OF 2 1/2 INCHES. | | | 2) THIS PROJECT WILL REQUIRE APPROVAL FROM THE PALM | | | BEACH COUNTY DEPARTMENT OF ENVIRONMENTAL RESOURCE | | | MANAGEMENT. SUBMIT VERIFICATION THAT THE PLANS HAVE | | | BEEN REVIEWED AND APPROVED BY THAT DEPARTMENT. WPB | | | AMEND. TO FBC SEC. 107.2.1. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2015-08-24 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-08-24 |
Time |
04:37 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-08-24 |
Time |
03:23 |
Sent To |
|
|
| Notes |
| 2015-08-24 04:37:07 | 1) THIS PROJECT WILL REQUIRE APPROVAL FROM THE PALM | | | BEACH COUNTY DEPARTMENT OF ENVIRONMENTAL RESOURCE | | | MANAGEMENT. SUBMIT VERIFICATION THAT THE PLANS HAVE | | | BEEN REVIEWED AND APPROVED BY THAT DEPARTMENT. WPB | | | AMEND. TO FBC SEC. 107.2.1. | | | 2) SHT. G0 REFERS TO THE 2010 FLORIDA BUILDING CODES. | | | THIS PROJECT FALLS UNDER THE 2014 (5TH EDITION) FLORIDA | | | BUILDING CODES. REVISE THE REFERENCE NOTES. | | | 3) SHT. G0 REFERS TO CANOPY DRAWINGS CS1 & CS 2. THESE | | | DRAWINGS ARE NOT IN THE PLANS. SUBMIT THESE DRAWINGS | | | FOR REVIEW. | | | 4) SUBMIT THE SIZE OF THE DOWNSPOUT FOR THE CANOPY | | | ROOFS.SUBMIT PLANS FOR THE CANOPIES THAT SHOW LOCATION | | | OF THE CANOPY ROOF DRAINS AND THE SQUARE FOOTAGE | | | DRAINED BY EACH DRAIN. THE SIZING OF THE ROOF DRAINS | | | AND PIPING SHALL COMPLY WITH THE 2014 | | | FBC-PLUMBING,TABLES 1106.2 (1), 1106.3. IF THE | | | DOWNSPOUT CONNECTS TO A GUTTER SYSTEM, THEN TABLE | | | 1106.6 WILL ALSO APPLY. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
P |
Date |
2016-06-06 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2016-06-06 |
Time |
14:41 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2016-06-06 |
Time |
14:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
F |
Date |
2016-01-20 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2016-01-20 |
Time |
10:13 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2016-01-20 |
Time |
10:13 |
Sent To |
|
|
| Notes |
| 2016-01-20 10:13:57 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 01.20.2016 | | | PERMIT NO.: 15080304 / 15080306 | | | ADDRESS: 2100 45TH STREET | | | CONTRACTOR/CONTACT: | | | TELEPHONE NO.: | | | SCOPE OF REVIEW: UNDERGROUND STORAGE TANKS AND FUEL | | | DISPENSERS (15080304) AND CANOPY (15080306). | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. PURSUANT TO RESOLUTION NO. 189-15, PRIOR TO THE | | | ISSUANCE OF A BUILDING PERMIT, THE DEVELOPER SHALL | | | OBTAIN WRITTEN APPROVAL FROM PERINI LAND AND | | | DEVELOPMENT COMPANY, OR ITS SUCCESSORS OR ASSIGNS, IN | | | ACCORDANCE WITH THAT COVENANT AND CONDITION DISCLOSED | | | BY WARRANTY DEED RECORDED IN OFFICIAL RECORDS BOOK | | | 4469, PAGE 541 OF THE PUBLIC RECORDS OF PALM BEACH | | | COUNTY, FLORIDA. PERINI LAND AND DEVELOPMENT COMPANY IS | | | NOT THE PROPERTY OWNER; THEREFORE, THE LEASE AGREEMENT | | | IS NOT SUFFICIENT INFORMATION TO ADDRESS THIS COMMENT. | | | PLEASE CONTACT MYSELF, OR THE PROPERTY OWNER'S LEGAL | | | REPRESENTATIVE (GUNSTER) FOR MORE INFORMATION REGARDING | | | THIS. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | WWW.WPB.ORG | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2015-11-17 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2015-11-17 |
Time |
07:59 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2015-11-17 |
Time |
07:59 |
Sent To |
|
|
| Notes |
| 2015-11-17 07:59:37 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 11.17.2015 | | | PERMIT NO.: 15080304 / 15080306 | | | ADDRESS: 2100 45TH STREET | | | CONTRACTOR/CONTACT: | | | TELEPHONE NO.: | | | SCOPE OF REVIEW: UNDERGROUND STORAGE TANKS AND FUEL | | | DISPENSERS (15080304) AND CANOPY (15080306). | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. TWO (2) COPIES OF A CURRENT AND ACCURATE SURVEY | | | SHALL BE PROVIDED. SOMETHING IS WRONG WITH THE SURVEY | | | PROVIDED; ALL OF THE LABLES ARE BLACKED OUT. PLEASE | | | PROVIDE A CORRECT SURVEY. | | | | | | 2. PURSUANT TO RESOLUTION NO. 189-15, PRIOR TO THE | | | ISSUANCE OF A BUILDING PERMIT, THE DEVELOPER SHALL | | | OBTAIN WRITTEN APPROVAL FROM PERINI LAND AND | | | DEVELOPMENT COMPANY, OR ITS SUCCESSORS OR ASSIGNS, IN | | | ACCORDANCE WITH THAT COVENANT AND CONDITION DISCLOSED | | | BY WARRANTY DEED RECORDED IN OFFICIAL RECORDS BOOK | | | 4469, PAGE 541 OF THE PUBLIC RECORDS OF PALM BEACH | | | COUNTY, FLORIDA. PERINI LAND AND DEVELOPMENT COMPANY IS | | | NOT THE PROPERTY; THEREFORE, THE LEASE AGREEMENT IS NOT | | | SUFFICIENT INFORMATION TO ADDRESS THIS COMMENT. PLEASE | | | CONTACT MYSELF, OR THE PROPERTY OWNER'S LEGAL | | | REPRESENTATIVE (GUNSTER) FOR MORE INFORMATION REGARDING | | | THIS. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | WWW.WPB.ORG | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2015-10-07 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2015-10-07 |
Time |
13:47 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2015-10-07 |
Time |
13:47 |
Sent To |
|
|
| Notes |
| 2015-10-07 13:52:18 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 10.07.2015 | | | PERMIT NO.: 15080304 / 15080306 | | | ADDRESS: 2100 45TH STREET | | | CONTRACTOR/CONTACT: | | | TELEPHONE NO.: | | | SCOPE OF REVIEW: UNDERGROUND STORAGE TANKS AND FUEL | | | DISPENSERS (15080304) AND CANOPY (15080306). | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. TWO (2) COPIES OF A CURRENT AND ACCURATE SURVEY | | | SHALL BE PROVIDED. SOMETHING IS WRONG WITH THE SURVEY | | | PROVIDED; ALL OF THE LABLES ARE BLACKED OUT. PLEASE | | | PROVIDE A CORRECT SURVEY. | | | | | | 2. PURSUANT TO RESOLUTION NO. 189-15, PRIOR TO THE | | | ISSUANCE OF A BUILDING PERMIT, THE DEVELOPER SHALL | | | OBTAIN WRITTEN APPROVAL FROM PERINI LAND AND | | | DEVELOPMENT COMPANY, OR ITS SUCCESSORS OR ASSIGNS, IN | | | ACCORDANCE WITH THAT COVENANT AND CONDITION DISCLOSED | | | BY WARRANTY DEED RECORDED IN OFFICIAL RECORDS BOOK | | | 4469, PAGE 541 OF THE PUBLIC RECORDS OF PALM BEACH | | | COUNTY, FLORIDA. PERINI LAND AND DEVELOPMENT COMPANY IS | | | NOT THE PROPERTY; THEREFORE, THE LEASE AGREEMENT IS NOT | | | SUFFICIENT INFORMATION TO ADDRESS THIS COMMENT. PLEASE | | | CONTACT MYSELF, OR THE PROPERTY OWNER'S LEGAL | | | REPRESENTATIVE (GUNSTER) FOR MORE INFORMATION REGARDING | | | THIS. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | WWW.WPB.ORG | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2015-08-21 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2015-08-21 |
Time |
11:41 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2015-08-20 |
Time |
14:04 |
Sent To |
|
|
| Notes |
| 2015-08-21 11:41:56 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 08.21.2015 | | | PERMIT NO.: 15080304 / 15080306 | | | ADDRESS: 2100 45TH STREET | | | CONTRACTOR/CONTACT: | | | TELEPHONE NO.: | | | SCOPE OF REVIEW: UNDERGROUND STORAGE TANKS AND FUEL | | | DISPENSERS (15080304) AND CANOPY (15080306). | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. TWO (2) COPIES OF A CURRENT AND ACCURATE SURVEY | | | SHALL BE PROVIDED. | | | | | | 2. THE SITE PLAN SHALL PROVIDE THE SETBACKS FROM THE | | | PROPERTY LINE TO EACH OF THE FUEL TANKS, CANOPY, ETC. | | | | | | 3. PURSUANT TO RESOLUTION NO. 189-15, PRIOR TO THE | | | ISSUANCE OF A BUILDING PERMIT, THE DEVELOPER SHALL | | | OBTAIN WRITTEN APPROVAL FROM PERINI LAND AND | | | DEVELOPMENT COMPANY, OR ITS SUCCESSORS OR ASSIGNS, IN | | | ACCORDANCE WITH THAT COVENANT AND CONDITION DISCLOSED | | | BY WARRANTY DEED RECORDED IN OFFICIAL RECORDS BOOK | | | 4469, PAGE 541 OF THE PUBLIC RECORDS OF PALM BEACH | | | COUNTY, FLORIDA. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | WWW.WPB.ORG | | | |
|
|