| Plan Review Stops For Permit 15080270 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2015-12-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-12-01 |
Time |
13:12 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-12-01 |
Time |
07:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2015-10-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-10-27 |
Time |
07:51 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-10-26 |
Time |
10:24 |
Sent To |
|
|
| Notes |
| 2015-10-27 14:26:22 | APPROVED WITH EXCEPTION. THIS PLAN HAS BEEN APPROVED | | | PROVISIONALLY. FAILURE TO CORRECT THE LISTED | | | DEFICIENCIES IN THIS PLAN PRIOR TO INSPECTION WILL | | | RESULT IN FAILED INSPECTION(S) AND ASSESSMENT OF | | | RE-INSPECTION FEE(S). | | | 1) SUBMIT TWO SETS OF PRODUCT APPROVALS THAT HAVE BEEN | | | REVIEWED AND APPROVED BY THE DESIGNER OF RECORD FOR THE | | | 3'-0" X 8'-8" ARCHED TOP FRONT DOOR AND THE 8'-6" X | | | 8'-0" OVERHEAD GARAGE DOORS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-09-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-09-28 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-09-24 |
Time |
08:43 |
Sent To |
|
|
| Notes |
| 2015-09-28 10:28:54 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) SUBMIT TWO SETS OF RESIDENTIAL BUILDING FORMS TO | | | SHOW COMPLIANCE WITH 2014 FBC ENERGY CONSERVATION | | | R101.5 | | | | | | 2) THE SIZES OF THE BEAMS SHOWN ON THE PLANS SUPPORTING | | | THE SECOND FLOOR WALLS ARE DIFFERENT ON SHEETS A210 AND | | | S-2. FBC 107.2.1 | | | | | | 3) ON SHEET S-3 THE MARKS FOR SECTIONS 1, 2, 3 AND 4 | | | REFER TO SHEET S-2 AND THE SECTIONS ARE ON SHEET S-6. | | | FBC 107.2.1 | | | | | | 4) SPECIFY THE REQUIRED COMPONENT AND CLADDING DESIGN | | | PRESSURES FOR THE EXTERIOR DOORS AND WINDOWS ON THE | | | PLANS. FBC - R301.2.1 | | | | | | 5) SUBMIT TWO COPIES OF THE EVALUATION REPORTS WITH | | | INSTALLATION INSTRUCTIONS FOR THE SPRAY FOAM | | | INSULATION. FBC - R316 | | | | | | 6) SUBMIT TWO COPIES OF THE MANUFACTURER'S | | | SPECIFICATIONS WITH INSTALLATION INSTRUCTIONS AND | | | LISTING FOR THE IISOKERN FIREPLACE. FBC - R1001 & M1801 | | | | | | 7) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS | | | FOR THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE 9N-3 | | | THAT HAVE BEEN REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD. PROVIDE TWO COMPLETE PRODUCT | | | APPROVALS WITH FL OR NOA NUMBERS INCLUDING INSTALLATION | | | INSTRUCTIONS AND MAXIMUM DESIGN PRESSURES FOR THE CLAY | | | S-TILE ROOFING MATERIAL AND THE ARCH TOP FRONT DOOR. | | | | | | 8) SPECIFY THE SPECIFIC METHOD OF ATTACHMENT THAT WILL | | | BE USED TO INSTALL THE CLAY S-TILE AND RESIST THE | | | REQUIRED OVERTURN MOMENT. IF AN ADHESIVE IS USED SUBMIT | | | THE PRODUCT APPROVALS FOR IT. FBC - R905.3 & DCA RULE | | | 9N-3 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2015-10-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-10-27 |
Time |
13:19 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-10-27 |
Time |
07:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2015-09-25 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-09-25 |
Time |
16:37 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-09-25 |
Time |
16:37 |
Sent To |
|
|
| Notes |
| 2015-09-25 17:29:06 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY ELECTRICAL | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE FIRST FLOOR DEN/BEDROOM AND FIRST FLOOR LEVEL | | | REQUIRE SMOKE ALARMS. FBC-R314.3 SMOKE ALARMS SHALL BE | | | INSTALLED IN THE FOLLOWING LOCATIONS: | | | 1. IN EACH SLEEPING ROOM. | | | 2. OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE | | | VICINITY OF THE BEDROOMS. | | | 3. ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDING | | | BASEMENTS AND HABITABLE ATTICS BUT NOT INCLUDING CRAWL | | | SPACES AND UNINHABITABLE ATTICS. IN DWELLINGS OR | | | DWELLING UNITS WITH SPLIT LEVELS AND WITHOUT AN | | | INTERVENING DOOR BETWEEN THE ADJACENT LEVELS, A SMOKE | | | ALARM INSTALLED ON THE UPPER LEVEL SHALL SUFFICE FOR | | | THE ADJACENT LOWER LEVEL PROVIDED THAT THE LOWER LEVEL | | | IS LESS THAN ONE FULL STORY BELOW THE UPPER LEVEL. | | | WHEN MORE THAN ONE SMOKE ALARM IS REQUIRED TO BE | | | INSTALLED WITHIN AN INDIVIDUAL DWELLING UNIT THE ALARM | | | DEVICES SHALL BE INTERCONNECTED IN SUCH A MANNER THAT | | | THE ACTUATION OF ONE ALARM WILL ACTIVATE ALL OF THE | | | ALARMS IN THE INDIVIDUAL UNIT. | | | | | | 2) FBC-R 315.1 ? PROVIDE CARBON MONOXIDE ALARMS WITHIN | | | 10 FEET OF EACH SLEEPING ROOM. | | | | | | 3) E3901.2.1 SPACING. RECEPTACLES SHALL BE INSTALLED SO | | | THAT NO POINT MEASURED HORIZONTALLY ALONG THE FLOOR | | | LINE OF ANY WALL SPACE IS MORE THAN 6 FEET (1829 MM), | | | FROM A RECEPTACLE OUTLET. IT APPEARS THAT THE REQUIRED | | | SPACING HAS BEEN EXCEEDED ON THE FIRST FLOOR. E3901.2.3 | | | FLOOR RECEPTACLES. | | | RECEPTACLE OUTLETS IN FLOORS SHALL NOT BE COUNTED AS | | | PART OF THE REQUIRED NUMBER OF RECEPTACLE OUTLETS | | | EXCEPT WHERE LOCATED WITHIN 18 INCHES (457 MM) OF THE | | | WALL. | | | | | | 4) E3902.2 GARAGE AND ACCESSORY BUILDING RECEPTACLES. | | | ALL 125-VOLT, SINGLE-PHASE, 15- OR 20-AMPERE | | | RECEPTACLES INSTALLED IN GARAGES AND GRADE-LEVEL | | | PORTIONS OF UNFINISHED ACCESSORY BUILDINGS USED FOR | | | STORAGE OR WORK AREAS SHALL HAVE GROUND-FAULT | | | CIRCUIT-INTERRUPTER PROTECTION FOR PERSONNEL. GARAGE | | | DOOR RECEPTACLES ARE REQUIRED TO BE GFCI PROTECTED. | | | | | | 5) E3609.3 BONDING FOR OTHER SYSTEMS. | | | AN INTERSYSTEM BONDING TERMINATION FOR CONNECTING | | | INTERSYSTEM BONDING CONDUCTORS REQUIRED FOR OTHER | | | SYSTEMS SHALL BE PROVIDED EXTERNAL TO ENCLOSURES AT THE | | | SERVICE EQUIPMENT OR METERING EQUIPMENT ENCLOSURE AND | | | AT THE DISCONNECTING MEANS FOR ANY ADDITIONAL BUILDINGS | | | OR STRUCTURES. | | | | | | 6) E3609.7 BONDING OTHER METAL PIPING. | | | WHERE INSTALLED IN OR ATTACHED TO A BUILDING OR | | | STRUCTURE, METAL PIPING SYSTEMS, INCLUDING GAS PIPING, | | | CAPABLE OF BECOMING ENERGIZED SHALL BE BONDED TO THE | | | SERVICE EQUIPMENT ENCLOSURE, THE GROUNDED CONDUCTOR AT | | | THE SERVICE, THE GROUNDING ELECTRODE CONDUCTOR WHERE OF | | | SUFFICIENT SIZE, OR TO THE ONE OR MORE GROUNDING | | | ELECTRODES USED. | | | | | | 7) E3901.12 HVAC OUTLET. A 125-VOLT, SINGLE-PHASE, 15- | | | OR 20- AMPERE-RATED RECEPTACLE OUTLET SHALL BE | | | INSTALLED AT AN ACCESSIBLE LOCATION FOR THE SERVICING | | | OF HEATING, AIR-CONDITIONING AND REFRIGERATION | | | EQUIPMENT. THE RECEPTACLE SHALL BE LOCATED ON THE SAME | | | LEVEL AND WITHIN 25 FEET (7620 MM) OF THE HEATING, | | | AIR-CONDITIONING AND REFRIGERATION EQUIPMENT. THE | | | RECEPTACLE OUTLET SHALL NOT BE CONNECTED TO THE LOAD | | | SIDE OF THE HVAC EQUIPMENT DISCONNECTING MEANS. | | | | | | 8) ELECTRICAL GENERAL NOTE 12 ON E101 REFERENCES THE | | | 2008 NEC AND SHOULD REFERENCE FBCR E3902.12. | | | | | | 9) ELECTRICAL OUTLET NOTE 3 ON E101 REFERENCES THE 2011 | | | NEC 210.52 (WRONG SECTION FOR TAMPER RESISTANT | | | RECEPTACLES) AND SHOULD REFERENCE FBCR E4002.14. | | | | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2015-11-12 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-11-12 |
Time |
09:06 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-11-12 |
Time |
05:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2015-10-29 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-10-29 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-10-29 |
Time |
09:15 |
Sent To |
|
|
| Notes |
| 2015-10-29 09:22:34 | 1) SUBMIT CALCULATIONS FOR COMBUSTION AIR. 2ND REQUEST. | | | 2014 FBC-RES. SEC. G2407. | | | 2) THE TOTAL BTU LOAD I HAVE CALCULATED FOR THIS SYSTEM | | | BASED ON THE BTU LOAD SHOWN IS 1,103,000 BTU'S. REVISE | | | TOTAL BTU LOAD ON THE PLAN. | | | 3) BASED ON THE TOTAL BTU LOAD OF THE LOW PRESSURE | | | SYSTEM AND THE DISTANCE TO THE MOST REMOTE OUTLET (114 | | | FT. ) THE GALVANIZED LINE FROM THE REGULATOR SHALL BE A | | | MINIMUM OF 2 INCHES IN SIZE UP TO THE FIRST TRANSITION | | | TO CSST PER TABLE G2413.4 (1) OF 2014 FBC-RES. | | | 4) THE 10 FOOT SECTION OF CSST SHALL BE 2", NOT 1 1/4" | | | AS SHOWN PER TABLE G 2413.4 (5) OF 2014 FBC-RES. | | | 5) THE 60 FOOT SECTION OF CSST SHALL BE 2", NOT 1 1/4 " | | | PER 2014 FBC-RES. GAS TABLE G 2413.4 (5) OF 2014 | | | FBC-RES. | | | 6) THE SIZE OF THE CSST TO THE TANKLESS WATER HEATER IN | | | THE MASTER BATH SHALL BE 1 1/4" PER 2014 FBC-RES. TABLE | | | G2413.4 (5) AND THE GALVANIZED SHALL BE 1 1/4" PER | | | TABLE G2413.4 (1). | | | 7) THE SIZE OF THE GALVANIZED LINE TO THE POOL HEATER | | | SHALL BE 1 1/2" PER 2014 FBC-RES.TABLE G2413.4 (1) AND | | | THE CSST SHALL BE 2" PER TABLE G2413.4 (5). | | | 8) SUBMIT TWO COPIES OF OF MANUFACTURER'S | | | SPECIFICATIONS FOR ALL GAS APPLIANCES. THE ONLY SPECS | | | SUBMITTED WERE FOR THE FIREPLACE. APPLIANCES SHALL BE | | | LISTED AND LABELED PER 2014 FBC-RES. SEC. G2404.3. | | | 9) SHOW THE CORRELATING EHD OF THE CSST TO ENSURE | | | CORRECT SIZING. | | | | | | I SUGGEST YOU CALL TO MAKE AN APPOINTMENT TO GO OVER | | | THE GAS DRAWING. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2015-08-20 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-08-20 |
Time |
04:23 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-08-20 |
Time |
04:15 |
Sent To |
|
|
| Notes |
| 2015-08-20 04:19:12 | 1) SUBMIT A GAS RISER DIAGRAM FOR REVIEW. WPB AMEND. TO | | | FBC SEC. 107.2.1., 107.3.5.3. | | | 2) SUBMIT TWO COPIES OF MANUF. SPECIFICATIONS FOR ALL | | | GAS APPLIANCES. APPLIANCES SHALL BE LISTED AND LABELED. | | | FBC-R SEC. G2404.3. | | | 3) INDICATE PSI OF THE SYSTEM, TYPE OF PIPE TO BE USED, | | | DISTANCE FROM METER TO MOST REMOTE OUTLET, SIZING TABLE | | | USED TO SUPPLY GAS. REFER TO FBC-FUEL GAS SEC.G2413.3. | | | 4) SUBMIT CALCULATIONS FOR CCOMBUSTION AIR FOR THE | | | INTERIOR APPLIANCES. FBC-FUEL GAS SEC. G2407. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2015-08-26 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2015-08-26 |
Time |
15:14 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2015-08-26 |
Time |
15:14 |
Sent To |
|
|
| Notes |
| 2015-08-17 11:24:13 | 8/17/15 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2015-12-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-12-09 |
Time |
17:42 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-12-08 |
Time |
10:29 |
Sent To |
|
|
| Notes |
| 2015-12-09 10:29:51 | RMCDOUGAL'S DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2015-12-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-12-01 |
Time |
13:25 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-11-09 |
Time |
09:35 |
Sent To |
|
|
| Notes |
| 2015-11-10 09:35:43 | RESUB ROUTED TO RMCDOUGAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-11-06 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-11-06 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-10-09 |
Time |
09:30 |
Sent To |
|
|
| Notes |
| 2015-10-13 09:30:59 | RESUB ROUTED TO RMCDOUGAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-09-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-09-28 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-08-07 |
Time |
09:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
P |
Date |
2015-12-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-12-09 |
Time |
17:42 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-12-09 |
Time |
17:11 |
Sent To |
|
|
| Notes |
| 2015-12-09 17:41:58 | MU2015-28327, PAID $236.59 PLUS $5.91 INTERNET SERVICE | | | CHARGE. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2015-10-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-10-27 |
Time |
15:28 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-10-27 |
Time |
15:28 |
Sent To |
|
|
| Notes |
| 2015-10-27 15:29:38 | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES | | | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE | | | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM | | | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH | | | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT | | | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE | | | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL | | | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2015-09-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-09-24 |
Time |
08:43 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-09-24 |
Time |
08:43 |
Sent To |
|
|
| Notes |
| 2015-09-24 08:44:00 | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES | | | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE | | | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM | | | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH | | | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT | | | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE | | | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL | | | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
N |
Date |
2015-12-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-12-01 |
Time |
13:23 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-12-01 |
Time |
13:23 |
Sent To |
|
|
| Notes |
| 2015-12-01 13:24:53 | A SEPARATE LANDSCAPE PERMIT IS REQUIRED PRIOR TO C.O. | | | AND HAS BEEN APPLIED FOR UNDER PERMIT NUMBER 15111063. |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
2015-11-06 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
2015-11-06 |
Time |
09:25 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
2015-11-06 |
Time |
09:25 |
Sent To |
|
|
| Notes |
| 2015-11-06 09:45:06 | -NEED SEPARATE LANDSCAPE PERMIT | | | -LANDSCAPE PLAN DOES NOT MEET CODE FOR REQUIRED NUMBER | | | OF TREES. | | | LOT SIZE 11914 MINUS BUILDING COVERAGE 3195 EQUALS 8719 | | | SQ FT OPEN SPACE. | | | DIVIDE BY 1200 EQUALS 8 TREES REQUIRED. PALMS MAY BE | | | SUBSTITUTED FOR NO MORE THAN 35% OF THE REQUIRED TREES. | | | 2 PALMS EQUAL ONE TREE. | | | -LOCATIONS OF EXISTING TREES TO BE REMOVED ARE NOT | | | SHOWN ON LANDSCAPE PLAN. A TREE ALTERATION PERMIT IS | | | REQUIRED FOR TREE REMOVAL. | | | - ADD CHART FOR FLORIDA FRIENDLY LANDSCAPING COMPLIANCE | | | SECTION 94-446(G) |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2015-12-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-12-01 |
Time |
07:33 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-12-01 |
Time |
07:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2015-10-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-10-27 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-10-26 |
Time |
10:24 |
Sent To |
P |
|
| Notes |
| 2015-10-27 14:07:12 | PLAN | | | REVIEW COMMENTS | | | | | | 2ND REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY MECHANICAL | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) FBC-R - M1401.3 SIZING. HEATING AND COOLING | | | EQUIPMENT AND APPLIANCES SHALL BE SIZED BASED ON | | | BUILDING LOADS CALCULATED IN ACCORDANCE WITH ACCA | | | MANUAL J OR OTHER APPROVED HEATING AND COOLING | | | CALCULATION METHODOLOGIES. THE EQUIPMENT SIZING | | | CALCULATIONS THAT WERE SUBMITTED HAVE AN INFLATED | | | OCCUPANT LOAD OF 32 FOR THE FIRST FLOOR AND 16 FOR THE | | | SECOND FLOOR. PLEASE CORRECT. | | | | | | 2) FBC ENERGY CONSERVATION SECTIONS R101.5.1.1.1 OR | | | R101.5.1.1.2. THE ENERGY COMPLIANCE FORMS THAT WERE | | | SUBMITTED HAVE THE WRONG ORIENTATION. THE 3' X 8'-8" | | | FRONT DOOR FACES NORTH PER THE PLANS AND THE | | | CALCULATIONS HAVE IT FACING EAST. THE OCCUPANT LOAD IS | | | ALSO INCORRECT. THERE ARE 10 OCCUPANTS SPECIFIED FOR | | | THE FIRST FLOOR AND 6 OCCUPANTS FOR THE SECOND FLOOR. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2015-09-25 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-09-25 |
Time |
17:40 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-09-25 |
Time |
17:40 |
Sent To |
|
|
| Notes |
| 2015-09-25 18:09:56 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY MECHANICAL | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) FBC-R - M1401.3 SIZING. HEATING AND COOLING | | | EQUIPMENT AND APPLIANCES SHALL BE SIZED BASED ON | | | BUILDING LOADS CALCULATED IN ACCORDANCE WITH ACCA | | | MANUAL J OR OTHER APPROVED HEATING AND COOLING | | | CALCULATION METHODOLOGIES. PROVIDE TWO SETS OF | | | EQUIPMENT SIZING CALCULATIONS. | | | | | | 2) THE SUPPLY DUCT SIZES FOR THE LAUNDRY AND HER WALKIN | | | CLOSET ON THE FIRST FLOOR ARE MISSING FROM THE PLANS. | | | FBC 107.2.1 | | | | | | 3) SUBMIT TWO SETS OF ENERGY COMPLIANCE FORMS AS | | | REQUIRED BY FBC ENERGY CONSERVATION SECTIONS | | | R101.5.1.1.1 OR R101.5.1.1.2 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2015-11-02 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-11-02 |
Time |
13:46 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-11-02 |
Time |
13:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2015-10-29 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-10-29 |
Time |
09:15 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-10-29 |
Time |
08:37 |
Sent To |
|
|
| Notes |
| 2015-10-29 08:44:59 | 1) SUBMIT A PLUMBING RISER DIAGRAM THAT CORRELATES WITH | | | THE FLOOR PLAN. THE ONE SUBMITTED IS NOT CLOSE TO | | | MATCHING THE LOCATION OF THE PLUMBING FIXTURES ON THE | | | FLOOR PLAN.WPB AMEND. TO FBC SEC. 107.3.5.3. | | | 2) THE LAVATORY IN BATHROOM # 5? SHALL BE STACKED AND | | | VENTED. 2014 FBC RES. SEC.P3101.2.1, P3201.3. | | | 3) IDENTIFY THE BATHROOMS ON THE PLUMBING RISER | | | DIAGRAM. .WPB AMEND. TO FBC SEC. 107.3.5.3. | | | | | | I SUGGEST SETTING UP A MEETING TO DISCUSS THE COMMENTS. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2015-08-20 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-08-20 |
Time |
04:14 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-08-20 |
Time |
03:24 |
Sent To |
|
|
| Notes |
| 2015-08-20 04:14:49 | THE SUBMITTED SANITARY RISER IS NOT TO CODE. THE | | | FOLLOWING DEFICIENCIES ARE NOTED: | | | 1) THE SANITARY RISER AS DRAWN DOES NOT CORRELATE WITH | | | THE FIRST AND SECOND FLOORS FIXTURE LOCATION LAYOUT. | | | THE LAYOUT OF THE FIXTURES ON THE RISER SHALL CORRELATE | | | WITH THE FLOOR PLAN.WPB AMEND. TO FBC SEC. 107.2.1. | | | 2) THE LAUNDRY SINK SHALL BE STACKED AND VENTED PER | | | FBC-R SEC.P3101.2 | | | 3) WASHING MACHINE NOT PERMITTED ON WET VENT (AS | | | DRAWN).FBC-R SEC. P3108.1. | | | 4) THE NUMBER AND TYPE OF FIXTURES ALLOWED ON WET VENT | | | ARE EXCEEDED. | | | | | | SUBMIT A REVISED SANITARY RISER THAT IS CODE COMPLIANT. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2015-10-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-10-26 |
Time |
16:49 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-10-26 |
Time |
16:49 |
Sent To |
|
|
| Notes |
| 2015-10-26 16:50:24 | SANTEFE SPANISH "S" CLAY ROOF TILE - NOA NO.12-0210.01 | | | TILE BOND ROOF TILE ADHESIVE - NOA NO.11-0616.03 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2015-08-26 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2015-08-26 |
Time |
15:14 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2015-08-26 |
Time |
15:14 |
Sent To |
|
|
| Notes |
|
|