Plan Review Details - Permit 15080270
Plan Review Stops For Permit 15080270
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2015-12-01 Cont ID  
Sent By rmcdouga Date 2015-12-01 Time 13:12 Rev Time 0.00
Received By rmcdouga Date 2015-12-01 Time 07:33 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-10-27 Cont ID  
Sent By rmcdouga Date 2015-10-27 Time 07:51 Rev Time 0.00
Received By rmcdouga Date 2015-10-26 Time 10:24 Sent To  
Notes
2015-10-27 14:26:22APPROVED WITH EXCEPTION. THIS PLAN HAS BEEN APPROVED
 PROVISIONALLY. FAILURE TO CORRECT THE LISTED
 DEFICIENCIES IN THIS PLAN PRIOR TO INSPECTION WILL
 RESULT IN FAILED INSPECTION(S) AND ASSESSMENT OF
 RE-INSPECTION FEE(S).
 1) SUBMIT TWO SETS OF PRODUCT APPROVALS THAT HAVE BEEN
 REVIEWED AND APPROVED BY THE DESIGNER OF RECORD FOR THE
 3'-0" X 8'-8" ARCHED TOP FRONT DOOR AND THE 8'-6" X
 8'-0" OVERHEAD GARAGE DOORS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-09-28 Cont ID  
Sent By rmcdouga Date 2015-09-28 Time 15:05 Rev Time 0.00
Received By rmcdouga Date 2015-09-24 Time 08:43 Sent To  
Notes
2015-09-28 10:28:54PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) SUBMIT TWO SETS OF RESIDENTIAL BUILDING FORMS TO
 SHOW COMPLIANCE WITH 2014 FBC ENERGY CONSERVATION
 R101.5
  
 2) THE SIZES OF THE BEAMS SHOWN ON THE PLANS SUPPORTING
 THE SECOND FLOOR WALLS ARE DIFFERENT ON SHEETS A210 AND
 S-2. FBC 107.2.1
  
 3) ON SHEET S-3 THE MARKS FOR SECTIONS 1, 2, 3 AND 4
 REFER TO SHEET S-2 AND THE SECTIONS ARE ON SHEET S-6.
 FBC 107.2.1
  
 4) SPECIFY THE REQUIRED COMPONENT AND CLADDING DESIGN
 PRESSURES FOR THE EXTERIOR DOORS AND WINDOWS ON THE
 PLANS. FBC - R301.2.1
  
 5) SUBMIT TWO COPIES OF THE EVALUATION REPORTS WITH
 INSTALLATION INSTRUCTIONS FOR THE SPRAY FOAM
 INSULATION. FBC - R316
  
 6) SUBMIT TWO COPIES OF THE MANUFACTURER'S
 SPECIFICATIONS WITH INSTALLATION INSTRUCTIONS AND
 LISTING FOR THE IISOKERN FIREPLACE. FBC - R1001 & M1801
  
 7) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS
 FOR THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE 9N-3
 THAT HAVE BEEN REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD. PROVIDE TWO COMPLETE PRODUCT
 APPROVALS WITH FL OR NOA NUMBERS INCLUDING INSTALLATION
 INSTRUCTIONS AND MAXIMUM DESIGN PRESSURES FOR THE CLAY
 S-TILE ROOFING MATERIAL AND THE ARCH TOP FRONT DOOR.
  
 8) SPECIFY THE SPECIFIC METHOD OF ATTACHMENT THAT WILL
 BE USED TO INSTALL THE CLAY S-TILE AND RESIST THE
 REQUIRED OVERTURN MOMENT. IF AN ADHESIVE IS USED SUBMIT
 THE PRODUCT APPROVALS FOR IT. FBC - R905.3 & DCA RULE
 9N-3

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2015-10-27 Cont ID  
Sent By rmcdouga Date 2015-10-27 Time 13:19 Rev Time 0.00
Received By rmcdouga Date 2015-10-27 Time 07:51 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2015-09-25 Cont ID  
Sent By rmcdouga Date 2015-09-25 Time 16:37 Rev Time 0.00
Received By rmcdouga Date 2015-09-25 Time 16:37 Sent To  
Notes
2015-09-25 17:29:06PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY ELECTRICAL
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE FIRST FLOOR DEN/BEDROOM AND FIRST FLOOR LEVEL
 REQUIRE SMOKE ALARMS. FBC-R314.3 SMOKE ALARMS SHALL BE
 INSTALLED IN THE FOLLOWING LOCATIONS:
 1. IN EACH SLEEPING ROOM.
 2. OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE
 VICINITY OF THE BEDROOMS.
 3. ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDING
 BASEMENTS AND HABITABLE ATTICS BUT NOT INCLUDING CRAWL
 SPACES AND UNINHABITABLE ATTICS. IN DWELLINGS OR
 DWELLING UNITS WITH SPLIT LEVELS AND WITHOUT AN
 INTERVENING DOOR BETWEEN THE ADJACENT LEVELS, A SMOKE
 ALARM INSTALLED ON THE UPPER LEVEL SHALL SUFFICE FOR
 THE ADJACENT LOWER LEVEL PROVIDED THAT THE LOWER LEVEL
 IS LESS THAN ONE FULL STORY BELOW THE UPPER LEVEL.
 WHEN MORE THAN ONE SMOKE ALARM IS REQUIRED TO BE
 INSTALLED WITHIN AN INDIVIDUAL DWELLING UNIT THE ALARM
 DEVICES SHALL BE INTERCONNECTED IN SUCH A MANNER THAT
 THE ACTUATION OF ONE ALARM WILL ACTIVATE ALL OF THE
 ALARMS IN THE INDIVIDUAL UNIT.
  
 2) FBC-R 315.1 ? PROVIDE CARBON MONOXIDE ALARMS WITHIN
 10 FEET OF EACH SLEEPING ROOM.
  
 3) E3901.2.1 SPACING. RECEPTACLES SHALL BE INSTALLED SO
 THAT NO POINT MEASURED HORIZONTALLY ALONG THE FLOOR
 LINE OF ANY WALL SPACE IS MORE THAN 6 FEET (1829 MM),
 FROM A RECEPTACLE OUTLET. IT APPEARS THAT THE REQUIRED
 SPACING HAS BEEN EXCEEDED ON THE FIRST FLOOR. E3901.2.3
 FLOOR RECEPTACLES.
 RECEPTACLE OUTLETS IN FLOORS SHALL NOT BE COUNTED AS
 PART OF THE REQUIRED NUMBER OF RECEPTACLE OUTLETS
 EXCEPT WHERE LOCATED WITHIN 18 INCHES (457 MM) OF THE
 WALL.
  
 4) E3902.2 GARAGE AND ACCESSORY BUILDING RECEPTACLES.
 ALL 125-VOLT, SINGLE-PHASE, 15- OR 20-AMPERE
 RECEPTACLES INSTALLED IN GARAGES AND GRADE-LEVEL
 PORTIONS OF UNFINISHED ACCESSORY BUILDINGS USED FOR
 STORAGE OR WORK AREAS SHALL HAVE GROUND-FAULT
 CIRCUIT-INTERRUPTER PROTECTION FOR PERSONNEL. GARAGE
 DOOR RECEPTACLES ARE REQUIRED TO BE GFCI PROTECTED.
  
 5) E3609.3 BONDING FOR OTHER SYSTEMS.
 AN INTERSYSTEM BONDING TERMINATION FOR CONNECTING
 INTERSYSTEM BONDING CONDUCTORS REQUIRED FOR OTHER
 SYSTEMS SHALL BE PROVIDED EXTERNAL TO ENCLOSURES AT THE
 SERVICE EQUIPMENT OR METERING EQUIPMENT ENCLOSURE AND
 AT THE DISCONNECTING MEANS FOR ANY ADDITIONAL BUILDINGS
 OR STRUCTURES.
  
 6) E3609.7 BONDING OTHER METAL PIPING.
 WHERE INSTALLED IN OR ATTACHED TO A BUILDING OR
 STRUCTURE, METAL PIPING SYSTEMS, INCLUDING GAS PIPING,
 CAPABLE OF BECOMING ENERGIZED SHALL BE BONDED TO THE
 SERVICE EQUIPMENT ENCLOSURE, THE GROUNDED CONDUCTOR AT
 THE SERVICE, THE GROUNDING ELECTRODE CONDUCTOR WHERE OF
 SUFFICIENT SIZE, OR TO THE ONE OR MORE GROUNDING
 ELECTRODES USED.
  
 7) E3901.12 HVAC OUTLET. A 125-VOLT, SINGLE-PHASE, 15-
 OR 20- AMPERE-RATED RECEPTACLE OUTLET SHALL BE
 INSTALLED AT AN ACCESSIBLE LOCATION FOR THE SERVICING
 OF HEATING, AIR-CONDITIONING AND REFRIGERATION
 EQUIPMENT. THE RECEPTACLE SHALL BE LOCATED ON THE SAME
 LEVEL AND WITHIN 25 FEET (7620 MM) OF THE HEATING,
 AIR-CONDITIONING AND REFRIGERATION EQUIPMENT. THE
 RECEPTACLE OUTLET SHALL NOT BE CONNECTED TO THE LOAD
 SIDE OF THE HVAC EQUIPMENT DISCONNECTING MEANS.
  
 8) ELECTRICAL GENERAL NOTE 12 ON E101 REFERENCES THE
 2008 NEC AND SHOULD REFERENCE FBCR E3902.12.
  
 9) ELECTRICAL OUTLET NOTE 3 ON E101 REFERENCES THE 2011
 NEC 210.52 (WRONG SECTION FOR TAMPER RESISTANT
 RECEPTACLES) AND SHOULD REFERENCE FBCR E4002.14.
  
  
  
  

Review Stop G GAS REVIEW
Rev No 3 Status P Date 2015-11-12 Cont ID  
Sent By tklarge Date 2015-11-12 Time 09:06 Rev Time 0.00
Received By tklarge Date 2015-11-12 Time 05:50 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status F Date 2015-10-29 Cont ID  
Sent By tklarge Date 2015-10-29 Time 10:31 Rev Time 0.00
Received By tklarge Date 2015-10-29 Time 09:15 Sent To  
Notes
2015-10-29 09:22:341) SUBMIT CALCULATIONS FOR COMBUSTION AIR. 2ND REQUEST.
 2014 FBC-RES. SEC. G2407.
 2) THE TOTAL BTU LOAD I HAVE CALCULATED FOR THIS SYSTEM
 BASED ON THE BTU LOAD SHOWN IS 1,103,000 BTU'S. REVISE
 TOTAL BTU LOAD ON THE PLAN.
 3) BASED ON THE TOTAL BTU LOAD OF THE LOW PRESSURE
 SYSTEM AND THE DISTANCE TO THE MOST REMOTE OUTLET (114
 FT. ) THE GALVANIZED LINE FROM THE REGULATOR SHALL BE A
 MINIMUM OF 2 INCHES IN SIZE UP TO THE FIRST TRANSITION
 TO CSST PER TABLE G2413.4 (1) OF 2014 FBC-RES.
 4) THE 10 FOOT SECTION OF CSST SHALL BE 2", NOT 1 1/4"
 AS SHOWN PER TABLE G 2413.4 (5) OF 2014 FBC-RES.
 5) THE 60 FOOT SECTION OF CSST SHALL BE 2", NOT 1 1/4 "
 PER 2014 FBC-RES. GAS TABLE G 2413.4 (5) OF 2014
 FBC-RES.
 6) THE SIZE OF THE CSST TO THE TANKLESS WATER HEATER IN
 THE MASTER BATH SHALL BE 1 1/4" PER 2014 FBC-RES. TABLE
 G2413.4 (5) AND THE GALVANIZED SHALL BE 1 1/4" PER
 TABLE G2413.4 (1).
 7) THE SIZE OF THE GALVANIZED LINE TO THE POOL HEATER
 SHALL BE 1 1/2" PER 2014 FBC-RES.TABLE G2413.4 (1) AND
 THE CSST SHALL BE 2" PER TABLE G2413.4 (5).
 8) SUBMIT TWO COPIES OF OF MANUFACTURER'S
 SPECIFICATIONS FOR ALL GAS APPLIANCES. THE ONLY SPECS
 SUBMITTED WERE FOR THE FIREPLACE. APPLIANCES SHALL BE
 LISTED AND LABELED PER 2014 FBC-RES. SEC. G2404.3.
 9) SHOW THE CORRELATING EHD OF THE CSST TO ENSURE
 CORRECT SIZING.
  
 I SUGGEST YOU CALL TO MAKE AN APPOINTMENT TO GO OVER
 THE GAS DRAWING.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  
  
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2015-08-20 Cont ID  
Sent By tklarge Date 2015-08-20 Time 04:23 Rev Time 0.00
Received By tklarge Date 2015-08-20 Time 04:15 Sent To  
Notes
2015-08-20 04:19:121) SUBMIT A GAS RISER DIAGRAM FOR REVIEW. WPB AMEND. TO
 FBC SEC. 107.2.1., 107.3.5.3.
 2) SUBMIT TWO COPIES OF MANUF. SPECIFICATIONS FOR ALL
 GAS APPLIANCES. APPLIANCES SHALL BE LISTED AND LABELED.
 FBC-R SEC. G2404.3.
 3) INDICATE PSI OF THE SYSTEM, TYPE OF PIPE TO BE USED,
 DISTANCE FROM METER TO MOST REMOTE OUTLET, SIZING TABLE
 USED TO SUPPLY GAS. REFER TO FBC-FUEL GAS SEC.G2413.3.
 4) SUBMIT CALCULATIONS FOR CCOMBUSTION AIR FOR THE
 INTERIOR APPLIANCES. FBC-FUEL GAS SEC. G2407.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2015-08-26 Cont ID  
Sent By fmittner Date 2015-08-26 Time 15:14 Rev Time 0.00
Received By fmittner Date 2015-08-26 Time 15:14 Sent To  
Notes
2015-08-17 11:24:138/17/15

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2015-12-09 Cont ID  
Sent By rmcdouga Date 2015-12-09 Time 17:42 Rev Time 0.00
Received By rmcdouga Date 2015-12-08 Time 10:29 Sent To  
Notes
2015-12-09 10:29:51RMCDOUGAL'S DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2015-12-01 Cont ID  
Sent By rmcdouga Date 2015-12-01 Time 13:25 Rev Time 0.00
Received By rmcdouga Date 2015-11-09 Time 09:35 Sent To  
Notes
2015-11-10 09:35:43RESUB ROUTED TO RMCDOUGAL

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-11-06 Cont ID  
Sent By skennedy Date 2015-11-06 Time 10:17 Rev Time 0.00
Received By skennedy Date 2015-10-09 Time 09:30 Sent To  
Notes
2015-10-13 09:30:59RESUB ROUTED TO RMCDOUGAL

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-09-28 Cont ID  
Sent By rmcdouga Date 2015-09-28 Time 15:05 Rev Time 0.00
Received By rmcdouga Date 2015-08-07 Time 09:41 Sent To  
Notes
2015-08-10 09:41:42R18

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status P Date 2015-12-09 Cont ID  
Sent By rmcdouga Date 2015-12-09 Time 17:42 Rev Time 0.00
Received By rmcdouga Date 2015-12-09 Time 17:11 Sent To  
Notes
2015-12-09 17:41:58MU2015-28327, PAID $236.59 PLUS $5.91 INTERNET SERVICE
 CHARGE.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2015-10-27 Cont ID  
Sent By rmcdouga Date 2015-10-27 Time 15:28 Rev Time 0.00
Received By rmcdouga Date 2015-10-27 Time 15:28 Sent To  
Notes
2015-10-27 15:29:38BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES
 MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE
 SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM
 BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH
 THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT
 MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE
 THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2015-09-24 Cont ID  
Sent By rmcdouga Date 2015-09-24 Time 08:43 Rev Time 0.00
Received By rmcdouga Date 2015-09-24 Time 08:43 Sent To  
Notes
2015-09-24 08:44:00BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES
 MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE
 SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM
 BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH
 THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT
 MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE
 THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.

Review Stop L LANDSCAPING
Rev No 2 Status N Date 2015-12-01 Cont ID  
Sent By rmcdouga Date 2015-12-01 Time 13:23 Rev Time 0.00
Received By rmcdouga Date 2015-12-01 Time 13:23 Sent To  
Notes
2015-12-01 13:24:53A SEPARATE LANDSCAPE PERMIT IS REQUIRED PRIOR TO C.O.
 AND HAS BEEN APPLIED FOR UNDER PERMIT NUMBER 15111063.

Review Stop L LANDSCAPING
Rev No 1 Status F Date 2015-11-06 Cont ID  
Sent By rcaranci Date 2015-11-06 Time 09:25 Rev Time 0.00
Received By rcaranci Date 2015-11-06 Time 09:25 Sent To  
Notes
2015-11-06 09:45:06-NEED SEPARATE LANDSCAPE PERMIT
 -LANDSCAPE PLAN DOES NOT MEET CODE FOR REQUIRED NUMBER
 OF TREES.
 LOT SIZE 11914 MINUS BUILDING COVERAGE 3195 EQUALS 8719
 SQ FT OPEN SPACE.
 DIVIDE BY 1200 EQUALS 8 TREES REQUIRED. PALMS MAY BE
 SUBSTITUTED FOR NO MORE THAN 35% OF THE REQUIRED TREES.
 2 PALMS EQUAL ONE TREE.
 -LOCATIONS OF EXISTING TREES TO BE REMOVED ARE NOT
 SHOWN ON LANDSCAPE PLAN. A TREE ALTERATION PERMIT IS
 REQUIRED FOR TREE REMOVAL.
 - ADD CHART FOR FLORIDA FRIENDLY LANDSCAPING COMPLIANCE
 SECTION 94-446(G)

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2015-12-01 Cont ID  
Sent By rmcdouga Date 2015-12-01 Time 07:33 Rev Time 0.00
Received By rmcdouga Date 2015-12-01 Time 07:33 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2015-10-27 Cont ID  
Sent By rmcdouga Date 2015-10-27 Time 14:16 Rev Time 0.00
Received By rmcdouga Date 2015-10-26 Time 10:24 Sent To P
Notes
2015-10-27 14:07:12PLAN
 REVIEW COMMENTS
  
 2ND REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY MECHANICAL
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) FBC-R - M1401.3 SIZING. HEATING AND COOLING
 EQUIPMENT AND APPLIANCES SHALL BE SIZED BASED ON
 BUILDING LOADS CALCULATED IN ACCORDANCE WITH ACCA
 MANUAL J OR OTHER APPROVED HEATING AND COOLING
 CALCULATION METHODOLOGIES. THE EQUIPMENT SIZING
 CALCULATIONS THAT WERE SUBMITTED HAVE AN INFLATED
 OCCUPANT LOAD OF 32 FOR THE FIRST FLOOR AND 16 FOR THE
 SECOND FLOOR. PLEASE CORRECT.
  
 2) FBC ENERGY CONSERVATION SECTIONS R101.5.1.1.1 OR
 R101.5.1.1.2. THE ENERGY COMPLIANCE FORMS THAT WERE
 SUBMITTED HAVE THE WRONG ORIENTATION. THE 3' X 8'-8"
 FRONT DOOR FACES NORTH PER THE PLANS AND THE
 CALCULATIONS HAVE IT FACING EAST. THE OCCUPANT LOAD IS
 ALSO INCORRECT. THERE ARE 10 OCCUPANTS SPECIFIED FOR
 THE FIRST FLOOR AND 6 OCCUPANTS FOR THE SECOND FLOOR.
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2015-09-25 Cont ID  
Sent By rmcdouga Date 2015-09-25 Time 17:40 Rev Time 0.00
Received By rmcdouga Date 2015-09-25 Time 17:40 Sent To  
Notes
2015-09-25 18:09:56PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY MECHANICAL
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) FBC-R - M1401.3 SIZING. HEATING AND COOLING
 EQUIPMENT AND APPLIANCES SHALL BE SIZED BASED ON
 BUILDING LOADS CALCULATED IN ACCORDANCE WITH ACCA
 MANUAL J OR OTHER APPROVED HEATING AND COOLING
 CALCULATION METHODOLOGIES. PROVIDE TWO SETS OF
 EQUIPMENT SIZING CALCULATIONS.
  
 2) THE SUPPLY DUCT SIZES FOR THE LAUNDRY AND HER WALKIN
 CLOSET ON THE FIRST FLOOR ARE MISSING FROM THE PLANS.
 FBC 107.2.1
  
 3) SUBMIT TWO SETS OF ENERGY COMPLIANCE FORMS AS
 REQUIRED BY FBC ENERGY CONSERVATION SECTIONS
 R101.5.1.1.1 OR R101.5.1.1.2
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2015-11-02 Cont ID  
Sent By tklarge Date 2015-11-02 Time 13:46 Rev Time 0.00
Received By tklarge Date 2015-11-02 Time 13:46 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2015-10-29 Cont ID  
Sent By tklarge Date 2015-10-29 Time 09:15 Rev Time 0.00
Received By tklarge Date 2015-10-29 Time 08:37 Sent To  
Notes
2015-10-29 08:44:591) SUBMIT A PLUMBING RISER DIAGRAM THAT CORRELATES WITH
 THE FLOOR PLAN. THE ONE SUBMITTED IS NOT CLOSE TO
 MATCHING THE LOCATION OF THE PLUMBING FIXTURES ON THE
 FLOOR PLAN.WPB AMEND. TO FBC SEC. 107.3.5.3.
 2) THE LAVATORY IN BATHROOM # 5? SHALL BE STACKED AND
 VENTED. 2014 FBC RES. SEC.P3101.2.1, P3201.3.
 3) IDENTIFY THE BATHROOMS ON THE PLUMBING RISER
 DIAGRAM. .WPB AMEND. TO FBC SEC. 107.3.5.3.
  
 I SUGGEST SETTING UP A MEETING TO DISCUSS THE COMMENTS.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2015-08-20 Cont ID  
Sent By tklarge Date 2015-08-20 Time 04:14 Rev Time 0.00
Received By tklarge Date 2015-08-20 Time 03:24 Sent To  
Notes
2015-08-20 04:14:49THE SUBMITTED SANITARY RISER IS NOT TO CODE. THE
 FOLLOWING DEFICIENCIES ARE NOTED:
 1) THE SANITARY RISER AS DRAWN DOES NOT CORRELATE WITH
 THE FIRST AND SECOND FLOORS FIXTURE LOCATION LAYOUT.
 THE LAYOUT OF THE FIXTURES ON THE RISER SHALL CORRELATE
 WITH THE FLOOR PLAN.WPB AMEND. TO FBC SEC. 107.2.1.
 2) THE LAUNDRY SINK SHALL BE STACKED AND VENTED PER
 FBC-R SEC.P3101.2
 3) WASHING MACHINE NOT PERMITTED ON WET VENT (AS
 DRAWN).FBC-R SEC. P3108.1.
 4) THE NUMBER AND TYPE OF FIXTURES ALLOWED ON WET VENT
 ARE EXCEEDED.
  
 SUBMIT A REVISED SANITARY RISER THAT IS CODE COMPLIANT.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  
  
  
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2015-10-26 Cont ID  
Sent By rmcdouga Date 2015-10-26 Time 16:49 Rev Time 0.00
Received By rmcdouga Date 2015-10-26 Time 16:49 Sent To  
Notes
2015-10-26 16:50:24SANTEFE SPANISH "S" CLAY ROOF TILE - NOA NO.12-0210.01
 TILE BOND ROOF TILE ADHESIVE - NOA NO.11-0616.03
  

Review Stop Z ZONING
Rev No 1 Status P Date 2015-08-26 Cont ID  
Sent By fmittner Date 2015-08-26 Time 15:14 Rev Time 0.00
Received By fmittner Date 2015-08-26 Time 15:14 Sent To  
Notes
***NONE***