| 2015-08-14 07:26:25 | BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 15080079 |
| | ADD: 5402 EAST AVENUE |
| | CONT: STUART & SHELBY |
| | TEL: (561)637-7902 |
| | E-MAIL:[email protected] |
| | |
| | 2014 FLORIDA BUILDING CODE W * 2014 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION, |
| | |
| | 2014 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: FRI. AUGUST 14/ 2015 |
| | ACTION: DENIED |
| | |
| | 1) ARCHITECTURAL PLANS BY RICHARD WENSING ARCHITECT ARE |
| | COPIES AND REDUCED IN SIZE. PLANS ARE COPYERIGHTED. |
| | |
| | 1A)PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS |
| | PREPARED BY THE DESIGN PROFESSIONAL AND BEING FILED FOR |
| | PUBLIC RECORD SHALL HAVE THE SIGNATURE AND SEAL OF THE |
| | DESIGN PROFESSIONAL AFFIXED TO THE DOCUMENT. FL ADMIN |
| | CODE 61G16.003 ARCHITECTS. |
| | |
| | 1B) 107.2.1.4 QUALITY OF BUILDING PLANS. BUILDING PLANS |
| | SHALL BE DRAWN TO A MINIMUM 1/8 INCH SCALE UPON |
| | SUBSTANTIAL PAPER. THE BUILDING OFFICIAL MAY ESTABLISH |
| | THROUGH DEPARTMENTAL POLICY, OTHER STANDARDS FOR PLANS |
| | AND SPECIFICATIONS, IN ORDER TO PROVIDE CONFORMITY TO |
| | ITS RECORD RETENTION PROGRAM. THIS POLICY MAY INCLUDE |
| | SUCH THINGS AS MINIMUM SIZE, SHAPE, CONTRAST, CLARITY, |
| | OR OTHER ITEMS RELATED TO RECORDS MANAGEMENT. |
| | ELECTRONIC MEDIA MUST BE COMPATIBLE WITH THE ARCHIVE |
| | REQUIREMENTS OF FLORIDA STATUTES. |
| | |
| | 2)107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS: |
| | OCCUPANCY TYPE |
| | MINIMUM BUILDING TYPE |
| | FIRE SPREINKLERED OR NOT |
| | FIRE-RESISTANT PROTECTION FOR TYPE OF CONSTRUCTION |
| | PROTECTION OF OPENINGS AND PENETRATIONS OF RATED WALLS |
| | AND OR CEILINGS MORE THAN 1STORY? |
| | |
| | 3) NOTE # 3 SCOPE OF WORK NOTE # 3 INDICATES THE |
| | REMOVAL OF ACOUSTICAL CEILINGS AND THEN FRAMING IN NEW |
| | AND HANGING DRYWALL CEILINGS AS REQUIRED BY CODE. NO |
| | PLANS WERE SUPPLIED TO BE ABLE TO COMPLETE A REVIEW |
| | WITH. NO MATERIALS, SPANS, NO INFORMATION. 107.3.5.1.1 |
| | MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. 2014 FBC-B |
| | TABLE 2508.1 ASTM C754; ASTM C1007, GA 216 & ASTM C840. |
| | PLANS WILL NEED TO IDENTIFY THE DEFLECTION LIMITATION, |
| | ALLOWABLE CEILING SPAN FOR TYPE OF FRAMING MEMBER, |
| | IDENTIFY FRAMING MEMBERS, WILL THEY NEED STIFF BACKS, |
| | GAUGE OF FRAMING MEMBERS, CENTERS OF FRAMING MEMBERS, |
| | THE THICKNESS OF DRYWALL, ATTACHMENT, TYPE OF FASTENER, |
| | SPACING, GAUGE OF FASTENER AND LENGTH OF FASTENER. |
| | |
| | NOTE DEPENDING ON THE A/C DUCTWORK LAYOUT, MAY REQUIRE |
| | FIRE DAMPERS AND ACCESSIBLE PANELS. |
| | |
| | 4) NOTE # 4 ADD ADDITIONAL STUDS TO SHOWER AREAS AS |
| | REQUIRED BY CODE. PLEASE PROVIDE THE SPACING OF STUDS, |
| | TYPE OF MATERIALS USED, FOR TYPE OF BUILDING, |
| | AND COMPLIANCE WITH 2014 FBC-B 2509.2 BASE FOR TILE. |
| | NOTE: 2014 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, SUCH |
| | INFORMATION SHALL BE SPECIFIC, |
| | AND THE TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE |
| | OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS |
| | EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC |
| | INFORMATION. |
| | |
| | 5) NOTE # 5. HHANG DEN-SHIED OR EQUAL. 2014 WEST PALM |
| | BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER |
| | 1, ADMINISTRATION, SUCH INFORMATION SHALL BE SPECIFIC, |
| | AND THE TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE |
| | OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS |
| | EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC |
| | INFORMATION. |
| | |
| | 6) NOTE # 9 INDICATES INSULATE FRAMED CEILING SPACES OF |
| | GUEST ROOMS WITH R-30 BATT MATERIALS. PLEASE SHOW |
| | COMPLIANCE WITH 2014 FBC-ENERGY C402.4.9.2 UNVENTED |
| | DROPPED CEILING CAVITIES. |
| | WHERE UNVENTED DROPPED CEILING CAVITIES OCCUR OVER |
| | CONDITIONED SPACES THAT DO NOT HAVE AN AIR BARRIER |
| | BETWEEN THE CONDITIONED AND UNCONDITIONED SPACE (SUCH |
| | AS T-BAR CEILINGS), THEY SHALL BE COMPLETELY SEALED |
| | FROM THE EXTERIOR ENVIRONMENT (AT THE ROOF PLANE) AND |
| | ADJACENT SPACES BY A CONTINUOUS AIR BARRIER THAT IS |
| | ALSO SEALED TO THE AIR BARRIER OF THE WALLS. IN THAT |
| | CASE, THE ROOF ASSEMBLY SHALL CONSTITUTE BOTH THE UPPER |
| | THERMAL ENVELOPE AND PRESSURE ENVELOPE OF THE BUILDING. |
| | |
| | |
| | 6) NOTE # 12 INDICATE TO INSTALL EXIT AND EMERGENCY |
| | LIGHTING AS REQUIRED. PLEASE PROVIDE A LIFE SAFETY |
| | PLAN. |
| | 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS: |
| | OCCUPANCY TYPE |
| | MINIMUM BUILDING TYPE |
| | FIRE SPREINKLERED OR NOT |
| | OCCUPANCY LOAD |
| | GROSS |
| | NET |
| | MEANS OF EGRESS |
| | EXIT ACCESS |
| | EXIT |
| | EXIT DISCHARGE |
| | EMERGENCY LIGHTING |
| | DERECTIONAL EXIT LIGHTS |
| | EXIT LIGHTS |
| | |
| | 7) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A |
| | RESULT OF THE ADDITIONAL INFORMATION REQUESTED |
| | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF |
| | THIS REVIEW. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |