| Plan Review Stops For Permit 15080008 |
| Review Stop |
AIPP |
ART IN PUBLIC PLACES |
| Rev No |
1 |
Status |
P |
Date |
2015-12-21 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2015-12-21 |
Time |
13:03 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2015-12-21 |
Time |
13:02 |
Sent To |
|
|
| Notes |
| 2015-12-21 13:05:25 | PER SYBILLE WELTER, ART IN PUBLIC PLACES (AIPP) | | | COORDINATOR, THE THE DEVELOPER HAS SUBMITTED THE | | | REQUIRED ART ASSESSMENT APPLICATION INCLUDING ESCROWED | | | FUNDS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2015-09-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-09-25 |
Time |
17:16 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-09-25 |
Time |
17:16 |
Sent To |
|
|
| Notes |
| 2015-09-25 17:03:16 | ****PROVISOS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | PROVISO, FLOOR PLANS NOT REVIEWED AT THIS TIME. WHEN | | | SUBMITTING FULL BUILDING PLANS, LIFE SAFETY PLANS TO | | | INCLUDE COMPLIANCE WITH FBC 5TH ED. ACCESSIBILITY | | | SECTION 207. | | | | | | PROVISO, PERMIT IS ISSUED AT CONTRACTOR'S RISK (PHASED | | | CONSTRUCTION FBC 105.13). | | | | | | PROVISO, SEPARATE PERMITS REQUIRED FOR LANDSCAPING, | | | PARKING LOT STRIPING AND LIGHTING, SIGNS, SEPARATE | | | STRUCTURES. | | | | | | PROVISO, ON THE PLAN, REFERENCE IS MADE TO EIFS AND | | | POLYSTYRENE. NOTE THAT THIS IS A TYPE II NONCOMBUSTIBLE | | | BUILDING AND ALL MATERIALS WILL BE IN COMPLIANCE WITH | | | FBC 602.2, 603. ANY EXCEPTIONS SHOULD BE INCORPORATED | | | INTO THE PLAN (WHEN BUILDING PLANS ARE SUBMITTED). | | | | | | PROVISO, STAIRS NOT INCLUDED IN SCOPE. STRUCTURAL | | | SHEETS WERE SUBMITTED 2ND REVIEW BUT DIMENSIONS TO SHOW | | | COMPLIANCE WITH FBC 1009 WERE NOT PROVIDED. CONTRACTOR | | | MAY SUBMIT A REVISION TO INCORPORATE THIS INTO SCOPE. | | | | | | PROVISO, POLYSTYRENE IS SPECIFIED (SEE DETAIL 7 S415 | | | AND OTHER LOCATIONS). PER ARCHITECT, THIS IS NOT | | | INCLUDED IN THE SCOPE OF THIS PERMIT. FBC 602, 603 | | | PROVIDE PRODUCT DATA REGARDING COMBUSTIBILITY WHEN | | | SUBMITTING THE FULL BUILDING PERMIT. | | | | | | PROVISO, SPECIFICATION PACKAGE NOT REVIEWED. PLANS ARE | | | TO DEMONSTRATE CODE COMPLIANCE INDEPENDENTLY OF THIS | | | DOCUMENT. | | | | | | PROVISO, BUILDING TYPE IIA REQUIRES 1 HR STRUCTURAL | | | FRAME; COMPLIANCE WITH FBC 704 REQUIRED. | | | | | | ADVISORY ONLY, PRODUCT APPROVALS WILL BE REQUIRED FOR | | | COMPONENTS AND CLADDING. THEY ARE REQUIRED TO BE | | | SUBMITTED, AFTER DESIGNER OF RECORD REVIEW, PRIOR TO | | | INSTALLATION. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2015-09-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-09-22 |
Time |
17:47 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-09-22 |
Time |
17:47 |
Sent To |
|
|
| Notes |
| 2015-09-22 17:48:08 | ****PROVISOS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | PROVISO, FLOOR PLANS NOT REVIEWED AT THIS TIME. | | | | | | PROVISO, PERMIT IS ISSUED AT CONTRACTOR'S RISK (PHASED | | | CONSTRUCTION FBC 105.13). | | | | | | PROVISO, SEPARATE PERMITS REQUIRED FOR LANDSCAPING, | | | PARKING LOT STRIPING AND LIGHTING, SIGNS, SEPARATE | | | STRUCTURES. | | | | | | PROVISO, ON THE PLAN, REFERENCE IS MADE TO EIFS AND | | | POLYSTYRENE. NOTE THAT THIS IS A TYPE II NONCOMBUSTIBLE | | | BUILDING AND ALL MATERIALS WILL BE IN COMPLIANCE WITH | | | FBC 602.2, 603. ANY EXCEPTIONS SHOULD BE INCORPORATED | | | INTO THE PLAN (WHEN BUILDING PLANS ARE SUBMITTED). | | | | | | PROVISO, STAIRS NOT INCLUDED IN SCOPE. STRUCTURAL | | | SHEETS WERE SUBMITTED 2ND REVIEW BUT DIMENSIONS TO SHOW | | | COMPLIANCE WITH FBC 1009 WERE NOT PROVIDED. SUBMIT A | | | REVISION TO INCORPORATE THIS INTO SCOPE. | | | | | | PROVISO, POLYSTYRENE IS SPECIFIED (SEE DETAIL 7 S415 | | | AND OTHER LOCATIONS). PER ARCHITECT, THIS IS NOT | | | INCLUDED IN THE SCOPE OF THIS PERMIT. FBC 602, 603 | | | PROVIDE PRODUCT DATA REGARDING COMBUSTIBILITY WHEN | | | SUBMITTING THE FULL BUILDING PERMIT. | | | | | | PROVISO, SPECIFICATION PACKAGE NOT REVIEWED. PLANS ARE | | | TO DEMONSTRATE CODE COMPLIANCE INDEPENDENTLY OF THIS | | | DOCUMENT. | | | | | | ADVISORY ONLY, PRODUCT APPROVALS WILL BE REQUIRED FOR | | | COMPONENTS AND CLADDING. THEY ARE REQUIRED TO BE | | | SUBMITTED, AFTER DESIGNER OF RECORD REVIEW, PRIOR TO | | | INSTALLATION. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-08-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-08-19 |
Time |
10:40 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-08-18 |
Time |
07:09 |
Sent To |
|
|
| Notes |
| 2015-08-19 09:33:14 | ****CORRECTIONS**** | | | REVISED 8/28/15 | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. SEE THRESHOLD REVIEW. THRESHOLD INSPECTION PLAN AND | | | OTHER REQUESTED DOCUMENTS ARE TO BE APPROVED PRIOR TO | | | PERMIT ISSUANCE. | | | | | | ALL PLANS PROVIDED BY ARCHITECT AND ENGINEER(S) ARE TO | | | INCLUDE THE STATEMENT PER FLORIDA STATUTE 553.79(7)(D): | | | | | | THRESHOLD BLDG, REQUIRED STATEMENT: W.P.B. AMENDMENT | | | 110.3.7.4.4 ALL PLANS FOR THE BUILDING WHICH ARE | | | REQUIRED TO BE SIGNED AND SEALED BY THE ARCHITECT OR | | | ENGINEER OF RECORD CONTAIN A STATEMENT CONSISTENT WITH | | | THE FLORIDA STATUTE REQUIREMENT FS 553.79(7)(D): | | | ALL PLANS FOR THE BUILDING WHICH ARE REQUIRED TO BE | | | SIGNED AND SEALED BY THE ARCHITECT OR ENGINEER OF | | | RECORD CONTAIN A STATEMENT THAT, TO THE BEST OF THE | | | ARCHITECT'S OR ENGINEER'S KNOWLEDGE, THE PLANS AND | | | SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM | | | BUILDING CODES AND THE APPLICABLE FIRESAFETY STANDARDS | | | AS DETERMINED BY THE LOCAL AUTHORITY IN ACCORDANCE WITH | | | THIS CHAPTER AND CHAPTER 633. | | | | | | 2. SEE IMPACT REVIEW. BEFORE A PERMIT TO CONSTRUCT MAY | | | BE ISSUED, AN IMPACT FEE ASSESSMENT BY PALM BEACH | | | COUNTY IS REQUIRED. THE ACTUAL PERMIT SET OF PLANS MUST | | | BE STAMPED BY THAT OFFICE, AND A COPY OF THE PAID | | | PROVIDED. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 3. SEE FS471, FS 481. A CERTIFICATE OF AUTHORIZATION IS | | | REQUIRED TO PRACTICE ARCHITECTURE OR ENGINEERING | | | THROUGH A COMPANY. | | | | | | COMMENT FOR ALL DESIGN PROFESSIONALS EXCEPT KIMLEY HORN | | | AND CODE CONSULTANTS; THE CERTIFICATE OF AUTHORIZATION | | | IS TO BE ON EACH SHEET (INCORPORATED INTO THE TITLE | | | BLOCK), FAC61G15 23.002, FS471, FS481. | | | | | | COMMENT FOR HOBBS & BLACK; SEND LICENSE NUMBER WHEN | | | AVAILABLE (SEE PROVISO). | | | | | | COMMENT FOR E&S CONSTRUCTION ENGINEERING (PLUMBING | | | ENGINEER), SEND LICENSE NUMBER WHEN AVAILABLE (SEE | | | PROVISO). | | | | | | THIS COMMENT WAS SENT TO WHITING TURNER AND RH VIA | | | EMAIL ON 8.19.15. | | | | | | 4. AT THE LOCATION OF THE SEAL, ALL SHEETS, THIS AREA | | | IS NOTED ON THE PLAN AS A CONSULTANT. PLEASE REMOVE | | | THIS LANGUAGE AS IT APPEARS THAT THE PLANS PROVIDED | | | HAVE BEEN DESIGNED BY THE DESIGN PROFESSIONALS TAKING | | | RESPONSIBILITY FOR THE PLANS, FS471, FS481. OR, CLARIFY | | | USE OF THE WORD CONSULTANT ON THE PLANS AS APPLICABLE | | | TO THIS STRUCTURE. | | | | | | 5. GOVERNING CODE CHANGED TO FLORIDA BUILDING CODE 5TH | | | EDITION (OR FBC 2014) ON JUNE 31, 2015; REVISE BUILDING | | | CODE DATA (SHEET A003), STRUCTURAL CALCS, S002, AND | | | OTHER SHEETS AS APPLICABLE. SHEET S102, NOTES INCLUDES | | | REFERENCES TO FBC 2012, PLEASE REVISE. | | | | | | 6. FOR A FOUNDATION PERMIT, ENOUGH INFORMATION TO | | | DEMONSTRATE CODE COMPLIANCE REGARDING THE PROPOSED | | | BUILDING IS REQUIRED. A003 IS NOTED FOR REFERENCE ONLY, | | | BUT THIS SHEET IS REQUIRED, FBC TABLE 503. A050 SHOWS | | | THE LOCATION OF THE PROPOSED CONSTRUCTION IN RELATION | | | TO THE LOT LINES, FBC TABLE 602. THESE TWO SHEETS ARE | | | REQUIRED FOR A FOUNDATION AND STRUCTURE PERMIT. | | | | | | 7. SEE STRUCTURAL CALCS. THIS DOCUMENT REFERENCES ACI | | | 318 08; THE STANDARD SHOULD BE ACI 318 11. AISC 360 | | | SHOULD REFERENCE 2010 (NOT 2005), SEE FBC CHAPTER 35. | | | REVISE ANY OTHER STANDARDS AS APPLICABLE. | | | | | | 8. REVISED TO BE A PROVISO ITEM (POLYSTYRENE NOT | | | INCLUDED IN SCOPE OF THIS PERMIT). | | | | | | PROVISO ITEMS (INFORMATIONAL OR TO BE ADDRESSED AT A | | | FUTURE DATE) | | | | | | PROVISO, FLOOR PLANS NOT REVIEWED AT THIS TIME. | | | | | | PROVISO, PERMIT IS ISSUED AT CONTRACTOR'S RISK (PHASED | | | CONSTRUCTION FBC 105.13). | | | | | | PROVISO, SEPARATE PERMITS REQUIRED FOR LANDSCAPING, | | | PARKING LOT STRIPING AND LIGHTING, SIGNS, SEPARATE | | | STRUCTURES. | | | | | | PROVISO, ON THE PLAN, REFERENCE IS MADE TO EIFS AND | | | POLYSTYRENE. NOTE THAT THIS IS A TYPE II NONCOMBUSTIBLE | | | BUILDING AND ALL MATERIALS WILL BE IN COMPLIANCE WITH | | | FBC 602.2, 603. ANY EXCEPTIONS SHOULD BE INCORPORATED | | | INTO THE PLAN (WHEN BUILDING PLANS ARE SUBMITTED). | | | | | | PROVISO, PROVIDE ARCHITECT BUSINESS LICENSE NUMBER WHEN | | | AVAILABLE; ISSUED AT CONTRACTOR'S RISK AND REQUIRED | | | PRIOR TO C.O. | | | PROVISO, PROVIDE PLUMBING ENGINEER'S BUSINESS LICENSE | | | NUMBER WHEN AVAILABLE; ISSUED AT CONTRACTOR'S RISK AND | | | REQUIRED PRIOR TO C.O. | | | | | | PROVISO, POLYSTYRENE IS SPECIFIED (SEE DETAIL 7 S415 | | | AND OTHER LOCATIONS). PER ARCHITECT, THIS IS NOT | | | INCLUDED IN THE SCOPE OF THIS PERMIT. FBC 602, 603 | | | PROVIDE PRODUCT DATA REGARDING COMBUSTIBILITY WHEN | | | SUBMITTING THE FULL BUILDING PERMIT. | | | | | | ADVISORY ONLY, PRODUCT APPROVALS WILL BE REQUIRED FOR | | | COMPONENTS AND CLADDING. THEY ARE REQUIRED TO BE | | | SUBMITTED, AFTER DESIGNER OF RECORD REVIEW, PRIOR TO | | | INSTALLATION. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2015-09-21 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-09-21 |
Time |
13:07 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-09-21 |
Time |
13:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2015-09-01 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-09-01 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-09-01 |
Time |
15:34 |
Sent To |
|
|
| Notes |
| 2015-09-01 15:37:35 | CODE: 2011 EDITION OF THE NEC, 2014/5TH EDITION OF THE | | | FBC | | | 1ST ELECTRICAL PLAN REVIEW FOUNDATION ONLY | | | ACTION: DENIED | | | | | | THERE ARE INSUFFICIENT ELECTRICAL PLANS OR | | | SPECIFICATIONS INCLUDED WITH THIS SUBMITTAL. REVISE | | | YOUR PLANS IN RESPONSE TO THE FOLLOWING REVIEW | | | COMMENTS: | | | | | | 1) AS A FOUNDATION ONLY REVIEW THE MINIMUM PLAN REVIEW | | | CRITERIA SHALL INCLUDE BUT NOT BE LIMITED TO AN | | | ELECTRICAL GOUNDING ELECTRODE SYSTEM DESIGN DETAIL PER | | | THE NEC ARTICLE 250. SEE NEC 250.30(7) AND 250.50 AND | | | 250.52 | | | | | | STEVEN KENNEDY, CBO | | | CHIEF PLANS EXAMINER | | | (561) 805-6710 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2015-09-02 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
2015-09-02 |
Time |
09:49 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
2015-09-02 |
Time |
09:22 |
Sent To |
|
|
| Notes |
| 2015-09-02 09:49:31 | LAND STABILIZATION AND EROSION CONTROL BONDS RECEIVED | | | AND IN EDS SAFE. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2015-08-12 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2015-08-12 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2015-08-12 |
Time |
13:24 |
Sent To |
|
|
| Notes |
| 2015-08-12 13:52:12 | 560 OKEECHOBEE BOULEVARD | | | PERMIT #15080008 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | **PERMIT FOR STRUCTURAL SHELL ONLY - SEPARATE PERMIT | | | NEEDED FOR INTERIOR DESIGN** | | | | | | | | | SHEET C3.00: RELOCATE THE NEW FIRE HYDRANT AND FIRE | | | DEPARTMENT CONNECTION TO THE NEW FIRE LANE EAST OF THE | | | BUILDING. | | | | | | SHEET C5.00 & FP-101: PER NFPA 24 SECTION 6.2.1, ALL | | | CONNECTIONS TO PRIVATE FIRE SERVICE MAINS FOR FIRE | | | PROTECTION SYSTEMS SHALL BE ARRANGED IN ACCORDANCE WITH | | | ONE OF THE FOLLOWING SO THAT THEY CAN BE ISOLATED: | | | (1)A POST INDICATOR VALVE INSTALLED NOT LESS THAN 40 | | | FEET FROM THE BUILDING. | | | (A) FOR BUILDINGS LESS THAN 40 FEET IN HEIGHT, A POST | | | INDICATOR VALVE SHALL BE PERMITTED TO BE INSTALLED | | | CLOSER THAN 40 FEET BUT AT LEAST AS FAR FROM THE | | | BUILDING AS THE HEIGHT OF THE WALL FACING THE POST | | | INDICATOR VALVE. | | | (2) A WALL POST INDICATOR VALVE | | | (3) AN INDICATING VALVE IN A PIT, INSTALLED IN | | | ACCORDANCE WITH SECTION 6.4 | | | (4) A BACKFLOW PREVENTER WITH AT LEAST ONE INDICATING | | | VALVE NOT LESS THAN 40 FEET FROM THE BUILDING. | | | (A) FOR BUILDINGS LESS THAN 40 FEET IN HEIGHT, A | | | BACKFLOW PREVENTER WITH AT LEAST ONE INDICATING VALVE | | | SHALL BE PERMITTED TO BE INSTALLED CLOSER THAN 40 FEET | | | BUT AT LEAST AS FAR FROM THE BUILDING AS THE HEIGHT OF | | | THE WALL FACING THE BACKFLOW PREVENTER. | | | (5) CONTROL VALVES INSTALLED IN A FIRE-RATED ROOM | | | ACCESSIBLE FROM THE EXTERIOR | | | (6) CONTROL VALVES IN A FIRE-RATED STAIR ENCLOSURE | | | ACCESSIBLE FROM THE EXTERIOR AS PERMITTED BY THE | | | AUTHORITY HAVING JURISDICTION | | | | | | CONSTRUCTION TRAILERS: TEMPORARY CONSTRUCTION TRAILERS | | | OR MODULAR BUILDINGS WILL REQUIRE A PERMIT AND | | | COMPLIANCE WITH THE FOLLOWING: | | | PER NFPA 241- STANDARD FOR SAFEGUARDING CONSTRUCTION, | | | ALTERATION, AND DEMOLITION OPERATIONS, SECTION 4.2: | | | TEMPORARY OFFICES, TRAILERS, AND OTHER FACILITIES OF | | | COMBUSTIBLE CONSTRUCTION OR HOUSING COMBUSTIBLE | | | CONTENTS SHALL BE SEPARATED FROM ADJACENT BUILDINGS, | | | TRAILERS OR STRUCTURES IN ACCORDANCE WITH TABLE 4.2.1. | | | PER TABLE 4.2.1: | | | 1) 20 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 30 FEET | | | 2) 30 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 35 FEET | | | 3) 40 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 40 FEET | | | 4) 50 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 45 FEET | | | 5) 60 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 50 FEET | | | 6) GREATER THAN 60 FEET EXPOSED LENGTH SHALL BE | | | SEPARATED FROM ADJACENT STRUCTURES BY AT LEAST 60 FEET | | | **A 75 PERCENT REDUCTION IN SEPARATION DISTANCES SHALL | | | BE PERMITTED TO BE APPLIED, PROVIDED AUTOMATIC | | | SPRINKLER PROTECTION IS USED IN THE EXPOSING STRUCTURE. | | | | | | DISCLAIMER: REVIEW AND APPROVAL BY THE AHJ SHALL NOT | | | RELIEVE THE OWNER, CONTRACTOR, ETC. OF THE | | | RESPONSIBILITY OF COMPLIANCE WITH CODE (NFPA 1, SECTION | | | 1.14.4). FBC SECTION 105.4.1 PERMIT INTENT: A PERMIT | | | ISSUED SHALL BE CONSTRUED TO BE A LICENSE TO PROCEED | | | WITH THE WORK AND NOT AS AUTHORITY TO VIOLATE, CANCEL, | | | ALTER OR SET ASIDE ANY OF THE PROVISIONS OF THE | | | TECHNICAL CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT | | | THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING A | | | CORRECTION OF ERRORS IN PLANS, CONSTRUCTION OR | | | VIOLATIONS OF THIS CODE. | | | | | | WESLEY JOLIN | | | ASSISTANT FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 805-6730 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-09-29 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2015-09-29 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2015-09-17 |
Time |
13:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-09-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-09-08 |
Time |
07:43 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-08-07 |
Time |
15:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
P |
Date |
2015-10-01 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-10-01 |
Time |
11:54 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-10-01 |
Time |
11:54 |
Sent To |
|
|
| Notes |
| 2015-10-01 11:55:31 | MU 201519031 PAID 51,593 SF | | | PLAN HAS BEEN REVISED TO 52,300 SF. PER WILLIE SWOPE, | | | THE IMPACT FEE RE-ASSESSMENT CAN BE DONE PRIOR TO | | | ISSUANCE OF BUILDING PERMIT. OK TO ISSUE | | | FOUNDATION/SUPERSTRUCTURE PERMIT AT THIS TIME | | | | | | PER EMAIL 10/1/15 | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2015-09-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-09-22 |
Time |
12:14 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-09-09 |
Time |
09:20 |
Sent To |
|
|
| Notes |
| 2015-09-22 12:14:33 | MU-2015-019031-0000 | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2015-08-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-08-19 |
Time |
10:39 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-08-19 |
Time |
10:39 |
Sent To |
|
|
| Notes |
| 2015-08-19 10:40:19 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | BEFORE A PERMIT TO CONSTRUCT MAY BE ISSUED, AN IMPACT | | | FEE ASSESSMENT BY PALM BEACH COUNTY IS REQUIRED. THE | | | ACTUAL PERMIT SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID PROVIDED. PLEASE CALL | | | (561)233-5025 FOR MORE INFORMATION. | | | | | | THIS CAN BE DONE AT ANY POINT IN THE PLAN REVIEW | | | PROCESS. | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2015-09-29 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-09-29 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-09-29 |
Time |
04:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2015-08-26 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-08-26 |
Time |
06:49 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-08-19 |
Time |
05:01 |
Sent To |
|
|
| Notes |
| 2015-08-24 09:27:11 | 1) SHT. 003 A-003 - SUBMIT THE OCCUPANT LOAD FOR EACH | | | FLOOR IN ACCORDANCE WITH TABLE 1004.1.2 OF THE 2014 | | | FBC-BUILDING. | | | 2) SHT.003 A-003 - APPLICABLE CODES BOX - THE PLAN | | | REFERS TO THE 2010 FBC AND OTHER CODE REFERENCES (2009 | | | PLUMBING CODE, 2008 NEC, ETC.). THIS PLAN FALLS UNDER | | | THE 2014 (5TH EDITION) OF THE FBC. REVISE THE NOTES TO | | | REFLECT THE CURRENT CODE APPLICABLE TTO THIS PROJECT. | | | 3) SHT.008 A-050 - THE FOUNTAINS SHALL BE UNDER A | | | SEPARATE PERMIT. A SEPARATE PERMIT APPLICATION AND | | | PLANS SHALL BE SUBMITTED FOR REVIEW AND APPROVAL. WPB | | | AMEND. TO FBC SEC. 105.1. | | | 4) THERE ARE SHEETS IN THIS SUBMITTAL PACKAGE THAT ARE | | | MARKED "FOR REFERENCE ONLY" AND ALSO "NOT FOR | | | CONSTRUCTION". CLARIFY. | | | 5) THE PLANS SHOW SANITARY FACILITIES LOCATED ON THE | | | FIRST AND FOURTH LEVELS. THIS DOES NOT COMPLY WITH 2014 | | | FBC-PLUMBING SEC.403.3.3.THE REQUIRED PUBLIC AND | | | EMPLOYEE TOILET FACILITIES SHALL BE LOCATED NOT MORE | | | THAN ONE STORY ABOVE OR BELOW THE SPACE REQUIRED TO BE | | | PROVIDED WITH TOILET FACILITIES, AND THE PATH OF TRAVEL | | | TO SUCH FACILITIES SHALL NOT EXCEED A DISTANCE OF 500 | | | FEET. | | | 6) SHT.013 A-105 - SUBMIT A ROOF DRAINAGE RISER DIAGRAM | | | AND STORM DRAINAGE CALCULATIONS. THE CALCULATIONS SHALL | | | INCLUDE ONE-HALF THE AREA OF ANY VERTICAL WALL THAT | | | DIVERTS RAINWATER TO THE ROOF AND ALSO ANY SLOPED ROOF | | | THAT DIVERTS RAINWATER TO A FLAT ROOF. 2014 | | | FBC-PLUMBING SEC.1106.4.ALSO, SUBMIT A SECTION DETAIL | | | OF THE ROOF GUTTER. GUTTERS SHALL BE SIZED PER TABLE | | | 1106.6. | | | 7) SHT.012 A-104 - SUBMIT A DETAIL FOR THE ROOF DRAINS | | | AND THE OVERFLOW DRAINS WPB AMEND. TO FBC SEC. 107.2.1. | | | 8) SHT.161 P-100 - 5" HORIZONTAL STORM DRAIN AT GRID | | | LINE B-3 IS SHOWN AS DRAINING AN AREA OF 2780 SQ. | | | FT.THE MAXIMUM SQUARE FOOTAGE THAT CAN BE DRAINED BY A | | | 5" HORIZONTAL LINE IS 2672 SQ. FT. COMPLY WITH TABLE | | | 1106.3. | | | 9) SHT.161 P-100 - 4" STORMWATER RISER NEAR GRID LINE | | | B-5 IS SHOWN DRAINING 4090 SQ. FT.AND THE MAXIMUM | | | SQUARE FOOTAGE PER TABLE 1106.2 (1) IS 3680 FOR A 4" | | | VERTICAL CONDUCTOR. | | | 10) SHT.161 P-100 - 4" STORMWATER RISER NEAR GRID LINE | | | "D" BETWEEN 5 & 6 - IS DRAINING 3770 SQ. FT. - THE | | | MAXIMUM SQUARE FOOTAGE THAT CAN BE DRAINED BY A 4" | | | VERTICAL LINE IS 3680 SQ. FT.PER TABLE 1106.2 (1). | | | 11) SHT.161 P-100 - THE PLAN SHOWS A 6" SANITARY LINE | | | WITH NO CONTINUATION POINT. SEE GRID LINE "E" BETWEEN 5 | | | & 6. SEE ALSO 6" LINE BETWEEN GRID LINES D & E AND 5-6. | | | 12) THE DISCHARGE FROM THE SUMP PUMP SHALL BE | | | INDIRECTLY CONNECTED TO THE PLUMBING SYSTEM PER THE | | | 2014 FBC-PLUMBING AND ALSO COMPLY WITH FPC SEC.1003.4. | | | 13) SHOW THE LOCATION OF THE GREASE TRAPS ON THE | | | ARCHITECTURAL SITE PLAN.WPB AMEND. TO FBC SEC. 107.2.1. | | | 14) SUBMIT GREASE TRAP CALCULATIONS IN ACCORDANCE WITH | | | 2014 FBC-PLUMBING SEC.1003.3.4. | | | 15) INDICATE CONTINUATION POINT OF 14" SW & 6" SANITARY | | | AT GRIDLINE "E" BETWEEN 4-5. | | | 16) DETAILS ON REMOTE ALARM TO BE SUBMITTED IN BUILDOUT | | | PLANS. | | | | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2015-09-29 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2015-09-29 |
Time |
14:35 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2015-09-29 |
Time |
14:35 |
Sent To |
|
|
| Notes |
| 2015-09-29 14:35:35 | DIGITAL SIGNATURES APPROVED PER SKENNEDY, PLANS | | | DIGITALLY SIGNED AND SEALED. |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
3 |
Status |
P |
Date |
2015-09-28 |
|
|
Cont ID |
|
| Sent By |
kconrad |
Date |
2015-09-28 |
Time |
11:43 |
Rev Time |
0.00 |
| Received By |
kconrad |
Date |
2015-09-28 |
Time |
11:43 |
Sent To |
I |
|
| Notes |
| 2015-09-28 11:45:43 | PROVISO: | | | | | | | | | PLEASE SUBMIT RESUME AND SIGNED SPECIAL INSPECTOR | | | AGREEMENT FOR A SECONDARY BUILDING INSPECTOR FOR THE | | | PROJECT. |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
2 |
Status |
P |
Date |
2015-09-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-09-29 |
Time |
10:12 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-09-19 |
Time |
14:41 |
Sent To |
|
|
| Notes |
| 2015-09-29 10:14:22 | OK W/PROVISO | | | PER KEN CONRAD | | | AT LEAST ONE ADDITIONAL INSPECTOR REQUIRED IN THE EVENT | | | THAT THE PRIMARY INSPECTOR IS UNAVAILABLE | | | SUBMIT FOR APPROVAL | | | | | | | | | | | 2015-09-19 14:54:55 | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | PENDING APPROVAL FROM KEN CONRAD | | | | | | TWO SETS OF THE THRESHOLD DOCUMENTS HAVE BEEN ROUTED TO | | | KEN CONRAD FOR FINAL APPROVAL. | | | ONE SET ON SH DESK | | | | | | | | | |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
1 |
Status |
F |
Date |
2015-08-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-08-19 |
Time |
09:03 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-08-19 |
Time |
09:03 |
Sent To |
|
|
| Notes |
| 2015-08-19 09:18:34 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. A COPY OF THE SPECIAL INSPECTOR AGREEMENT AND POLICY | | | WERE SENT VIA EMAIL TO JUSTIN MENENDEZ AND HENRY SHAWAH | | | AT WHITING-TURNER. | | | | | | 1A) THRESHOLD INSPECTION PLAN HAS BEEN FORWARDED TO KEN | | | CONRAD FOR REVIEW. 109.3.6.1 THE ENFORCING AGENCY SHALL | | | REQUIRE A SPECIAL INSPECTOR TO PERFORM STRUCTURAL | | | INSPECTIONS ON A THRESHOLD BUILDING PURSUANT TO A | | | (WRITTEN/ TYPED) STRUCTURAL INSPECTION PLAN PREPARED BY | | | THE ENGINEER OF RECORD. THE STRUCTURAL INSPECTION PLAN | | | MUST BE SUBMITTED TO THE ENFORCING AGENCY PRIOR TO THE | | | ISSUANCE OF A BUILDING PERMIT FOR THE CONSTRUCTION OF A | | | THRESHOLD BUILDING. THE PURPOSE OF THE STRUCTURAL | | | INSPECTION PLAN IS TO PROVIDE SPECIFIC INSPECTION | | | PROCEDURES AND SCHEDULES SO THAT THE BUILDING CAN BE | | | ADEQUATELY INSPECTED FOR COMPLIANCE WITH THE PERMITTED | | | DOCUMENTS. | | | | | | 1B) THRESHOLD INSPECTOR: WPB AMENDMENT 109.3.6.2 W.P.B. | | | CONSTRUCTION SERVICES DEPARTMENT REQUEST FOR THRESHOLD | | | BUILDINGS A SPECIAL INSPECTOR AS REQUIRED BY FL S S | | | 553.79(5) FLORIDA STATUTES TO THE MINIMUM INSPECTIONS | | | REQUIRED BY THIS CODE. THE INSPECTION COMPANY & | | | THRESHOLD INSPECTOR WILL NEED TO FILL OUT THE SPECIAL | | | INSPECTOR AGREEMENT FORMS AND RESUBMIT TO THE CITY FOR | | | REVIEW PRIOR TO PERMIT ISSUANCE. CONTACT KEN CONRAD | | | MANAGER OF THE SPECIAL INSPECTOR PROGRAM AT | | | (561)805-6666 FOR FURTHER INFORMATION | | | | | | PLEASE SUBMIT THE SPECIAL INSPECTOR AGREEMENT WITH ALL | | | APPLICABLE NOTARIZED SIGNATURES. | | | | | | 1C) THRESHOLD BLDG, REQUIRED STATEMENT: W.P.B. | | | AMENDMENT 110.3.7.4.4 ALL PLANS FOR THE BUILDING WHICH | | | ARE REQUIRED TO BE SIGNED AND SEALED BY THE ARCHITECT | | | OR ENGINEER OF RECORD CONTAIN A STATEMENT CONSISTENT | | | WITH THE FLORIDA STATUTE REQUIREMENT FS 553.79(7)(D): | | | | | | ALL PLANS FOR THE BUILDING WHICH ARE REQUIRED TO BE | | | SIGNED AND SEALED BY THE ARCHITECT OR ENGINEER OF | | | RECORD CONTAIN A STATEMENT THAT, TO THE BEST OF THE | | | ARCHITECT?S OR ENGINEER?S KNOWLEDGE, THE PLANS AND | | | SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM | | | BUILDING CODES AND THE APPLICABLE FIRESAFETY STANDARDS | | | AS DETERMINED BY THE LOCAL AUTHORITY IN ACCORDANCE WITH | | | THIS CHAPTER AND CHAPTER 633. | | | | | | THIS STATEMENT IS NOT INCLUDED ON ANY SHEETS WHICH WERE | | | SPOT CHECKED (VARIOUS A AND S SHEETS). | | | | | | 1D) FOR THE SPECIAL INSPECTOR PLEASE PROVIDE A RESUME' | | | OF INSPECTION EXPERIENCE ON PREVIOUS PROJECT. THE | | | RESUME' MUST BE ACCOMPANIED BY ALL CERTIFICATES AS | | | SPECIFIED HEREIN. THE BUILDING OFFICIAL OR HIS DESIGNEE | | | WILL REVIEW THE RESUME'. AFTER THE RESUME' IS REVIEWED, | | | AN INTERVIEW WILL BE SCHEDULED. UNDER NO CIRCUMSTANCES | | | WILL AN INSPECTOR BE INTERVIEWED FOR WORK WITHOUT FIRST | | | MEETING THE ABOVE CRITERIA. | | | CONTACT KEN CONRAD | | | TEL: 561-805-6666 | | | E-MAIL: [email protected] | | | | | | 1E) THE CONTRACTOR WILL PRODUCE A JOB SUMMARY OR | | | HISTORY FOR THIS TYPE OF CONSTRUCTION. THIS MAY BE | | | SUBMITTED TO KEN CONRAD BY E-MAIL. KEN CONRAD: | | | [email protected] | | | | | | 2. DOCUMENTS PREPARED BY AN ENGINEER ARE TO INCLUDE THE | | | CERTIFICATE OF AUTHORIZATION FOR THE ENGINEERING | | | COMPANY (29684), FS471, FAC61G15-23.002. | | | | | | YOU MAY ALSO SEE THIS REQUIREMENT AT WWW.FBPE.ORG | | | (LEGAL, LAWS AND RULES). | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2015-09-25 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2015-09-25 |
Time |
15:38 |
Rev Time |
2.00 |
| Received By |
eschneid |
Date |
2015-09-23 |
Time |
09:53 |
Sent To |
|
|
| Notes |
| 2015-09-23 10:04:02 | PASSED | | | | | | 1. THE DETAILS FOR THE FOLLOWING ITEMS HAVE BEEN | | | REVIEWED BY PLANNING STAFF FOR COMPLIANCE WITH RES. NO. | | | 206-15 AND HAVE BEEN ADDRESSED IN A SATISFACTORY MANNER | | | TO ISSUE THIS PERMIT. A FINAL FULL REVIEW WILL BE | | | CONDUCTED WHEN THE PLANS ARE SUBMITTED FOR THE INTERIOR | | | BUILDOUT AND THEY SHALL CONFORM TO THE DRAWINGS | | | SUBMITTED TO PLANNING STAFF FOR PERLIMINARY REVIEW. | | | A. PROVIDE AT LEAST ONE SHOWER AND CHANGING FACILITY | | | WITHIN THE BUILDING MEETING BOTH BUILDING CODE AND | | | PLANNING DIVISION REQUIREMENTS. NOTE: A SEAT FOR | | | CHANGING USE SHALL BE ADDED. | | | B. SHOW MERCHANDISE WINDOW DISPLAYS IN AS MANY OF THE | | | GROUND LEVEL GLAZED OPENINGS AS POSSIBLE. | | | | | | 2. SEPARATE PERMITS WITH PLANS ARE REQUIRED FOR THE | | | FOLLOWING ITEMS THAT ARE EXTERIOR TO THE BUILDING: | | | | | | A. AWNINGS | | | B. PARKING LOT STRIPING | | | C. LANDSCAPE | | | D. FOUNTAINS | | | E. SITE LIGHTING | | | F. HARDSCAPE | | | G. BICYCLE RACKS | | | H. WALLS AND GATES | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2015-08-20 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2015-08-20 |
Time |
08:42 |
Rev Time |
6.00 |
| Received By |
eschneid |
Date |
2015-08-19 |
Time |
13:31 |
Sent To |
|
|
| Notes |
| 2015-08-19 15:46:45 | FAILED | | | | | | PLEASE PROVIDE WRITTEN RESPONSES: | | | | | | 1. THE STEEL SUPERSTRUCTURE IS VERTICAL CONSTRUCTION, | | | SO IT TRIGGERS CONDITION NO. 1 OF RESOLUTION NO. 206-15 | | | LISTED BELOW: | | | | | | 1) PRIOR TO THE APPROVAL OF A BUILDING PERMIT FOR | | | VERTICAL CONSTRUCTION OF THE RESTORATION HARDWARE | | | GALLERY, THE APPLICANT SHALL: | | | | | | A. PROVIDE AT LEAST ONE SHOWER AND CHANGING FACILITY | | | WITHIN THE BUILDING MEETING BOTH BUILDING CODE AND | | | PLANNING DIVISION REQUIREMENTS. | | | B. SHOW MERCHANDISE WINDOW DISPLAYS IN AS MANY OF THE | | | GROUND LEVEL GLAZED OPENINGS AS POSSIBLE. | | | | | | 2. THE PLANS PROVIDED (FOR REFERENCE ONLY) DO NOT | | | INCLUDE INFORMATION ON THE SHOWER AND CHANGING | | | FACILITIES. THE CURRENT LAYOUT WITH NO SPECIFIC | | | INFORMATION WAS NOT APPROVED AS MEETING THE REQUIREMENT | | | BY THE PLANNING DIVISION DURING THE SITE PLAN APPROVAL | | | PROCESS. | | | | | | 3. THERE IS NO GLAZING SPECIFIC INFORMATION PROVIDED ON | | | THE GLAZING OF THE WINDOWS ON THE GROUND LEVEL FOR | | | STAFF TO VERIFY THE INTENT OF 1)B. | | | | | | 4. THE BUILDING CONTAINS MORE SQUARE FOOTAGE THAN WAS | | | APPROVED BY RESOLUTION NO. 206-15. A MINOR PLANNED | | | DEVELOPMENT AMENDMENT TO REFLECT THE NEW SQUARE FOOTAGE | | | IS REQUIRED PRIOR TO THE APPROVAL OF THE VERTICAL | | | CONSTRUCTION. THE MINOR PLANNED DEVELOPMENT AMENDMENT | | | SHALL SHOW WHERE THE BUILDING HAS GOTTEN LARGER AND THE | | | IMPACT ON THE SITE LAYOUT, TO INCLUDE THE SETBACKS, THE | | | LANDSCAPE, THE PARKING, ETC. | | | | | | 5. THE ARCHITECTURE IS DIFFERENT THAN THE ONE APPROVED | | | BY RESOLUTION NO. 206-15. A MINOR PLANNED DEVELOPMENT | | | AMENDMENT TO REFLECT THE NEW ELEVATIONS IS REQUIRED. | | | | | | 6. IN LIGHT OF THE TIMING TO ADDRESS THE COMMENTS | | | ABOVE, IT MAY BE ADVANTAGEOUS TO REVISE THE SCOPE OF | | | THIS PERMIT TO BE JUST FOR THE FOUNDATION TO GIVE | | | YOURSELVES MORE TIME TO ADDRESS THE COMMENTS RELATED TO | | | THE VERTICAL CONSTRUCTION. | | | | | | 7. SEPARATE PERMITS WITH PLANS ARE REQUIRED FOR THE | | | FOLLOWING: | | | | | | A. AWNINGS | | | B. PARKING LOT STRIPING | | | C. LANDSCAPE | | | D. FOUNTAINS | | | E. SITE LIGHTING | | | F. HARDSCAPE | | | G. BICYCLE RACKS | | | H. WALLS AND GATES | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | | | | 2015-08-17 11:17:02 | 8/17/15 |
|
|