| Plan Review Stops For Permit 15070950 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2016-01-19 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-01-15 |
Time |
18:16 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-01-15 |
Time |
18:15 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2015-11-10 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-11-10 |
Time |
09:08 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-11-10 |
Time |
09:06 |
Sent To |
E |
|
| Notes |
| 2015-11-10 09:22:33 | RESIDENTIAL (R3) ALTERATION, SECOND BUILDING REVIEW | | | CHECKLIST. (MAIN BUILDING). | | | CODE: FBC-5TH EDITION (2014). | | | | | | 1- CLEARLY SPECIFY THE TYPE AND SIZE OF EXISTING | | | BEDROOM WINDOWS AND TYPE AND SIZE OF PROPOSED BEDROOM | | | WINDOWS TO VERIFY COMPLIANCE WITH THE EGRESS | | | REQUIREMENTS OF SEC. 701.2 OF FBC-EXISTING BUILDING, | | | 5TH EDITION (2014). | | | | | | RESPONSE: PLANS SUBMITTED DON'T IDENTIFY THE TYPE AND | | | SIZE OF EXISTING WINDOWS. AND NEED TO SPECIFY THE | | | ACTUAL SIZE OF PROPOSED SINGLE HUNG WINDOWS NOT THE | | | OPENING SIZE. UNABLE TO VERIFY EGRESS COMPLIANCE | | | WITHOUT THE ACTUAL SIZE OF THE BEDROOM WINDOWS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-09-21 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-09-21 |
Time |
18:47 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-09-21 |
Time |
18:47 |
Sent To |
E |
|
| Notes |
| 2015-09-21 18:52:21 | RESIDENTIAL (R3) ALTERATION, BUILDING REVIEW COMMENTS | | | (FRONT BUILDING). | | | CODE: FBC-5TH EDITION (2014). | | | | | | 1- THE CURRENT CODE IS THE FBC-RESIDENTIAL, 5TH EDITION | | | (2014) NOT THE 2010 FBC. ENGINEER TO REVISE ALL DESIGN | | | CRITERIA AS REQUIRED. | | | | | | 2- A) ENGINEER TO REVISE THE WINDOWS AND DOORS DESIGN | | | PRESSURES CALCULATIONS. ACCORDING TO SEC. R301.2.1.4.3 | | | OF FBC-RESIDENTIAL, 5TH EDITION (2014) THIS BUILDING IS | | | LOCATED IN EXPOSURE "C" NOT "B". | | | | | | B) ENGINEER TO PROVIDE THE ENGINEER SEAL ON THE WINDOWS | | | AND DOORS DESIGN PRESSURES CALCULATIONS AS REQUIRED BY | | | CHAPTER 471 F.S. | | | | | | C) WINDOWS AND DOORS NUMBERS GIVEN ON THE ENGINEER | | | DESIGN PRESSURES CALCULATIONS DON'T MATCH THE NUMBERS | | | SHOWN ON THE FLOOR PLAN. REVISE AS REQUIRED TO MATCH. | | | SEC. 107.2.1 CITY AMENDMENTS. ALSO, COORDINATE THE | | | PRODUCT APPROVAL NUMBERS WITH THE REVISED PRODUCT | | | APPROVALS. SEE COMMENT #4 BELOW. | | | | | | 3- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | FAC 61G20-3.002(33) FOR: | | | A) SINGLE HUNG WINDOWS. FLORIDA PRODUCT APPROVAL | | | FL14604-R3 SUBMITTED IS NOT APPROVED. THE APPLICATION | | | STATUS SAYS "RE-APPLY". ALSO, NEED TO PROVIDE PRODUCT | | | APPROVAL FOR THE CURRENT CODE VERSION OF 2014. | | | | | | B) EXTERIOR DOORS. FLORIDA PRODUCT APPROVAL FL15558 | | | SUBMITTED IS FOR 2010 CODE VERSION. NEED TO PROVIDE | | | PRODUCT APPROVAL FOR THE CURRENT CODE VERSION OF 2014. | | | | | | ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | | COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2016-01-21 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-01-21 |
Time |
18:20 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-01-21 |
Time |
18:20 |
Sent To |
|
|
| Notes |
| 2016-01-19 09:32:27 | NEW DRAWINGS SUBMITTED. JG. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2015-11-13 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
|
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2015-11-19 |
Time |
13:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2015-09-22 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-09-22 |
Time |
15:39 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-09-22 |
Time |
15:39 |
Sent To |
HIST |
|
| Notes |
| 2015-09-22 15:47:43 | 1ST REVIEW: FBC 2014 5TH ED. | | | | | | THERE ARE TWO APPLICATIONS ONE FOR A FRONT BUILDING AND | | | ONE FOR A REAR BUILDING, BUT THE PLAN IS ONLY FOR ONE | | | BUILDING. ACCORDINGLY, I CANNOT DETERMINE THE SCOPE OF | | | WORK. | | | | | | THE APPLICABLE ELECTRICAL CODE IN THE A FUNCTION OF THE | | | BASE CODE CITED ABOVE. PLEASE REVISE PLAN TO INDICATE | | | THE APPLIED CODE IN EFFECT. | | | | | | A LOAD CALCULATION IS PROVIDED BUT IT IS UNKNOW IF IT | | | APPLIES TO ONE OR BOTH BUILDINGS/ | | | | | | THE RANGE CUICUIT SHOWN IS 40AMP, PROVIDE APPLIANCE | | | INFORMATION TO DEMONSTRATE ADEQUACY OF THIS OCP. | | | E4101.4 OVERCURRENT PROTECTION. | | | EACH APPLIANCE SHALL BE PROTECTED AGAINST OVERCURRENT | | | IN ACCORDANCE WITH THE RATING OF THE APPLIANCE AND ITS | | | LISTING. | | | | | | INFORMATION PROVIDED IS NOT SUFFICIENT TO ALLOW FOR | | | FULL REVIEW. | | | | | | STEVEN KENNEDY, CBO | | | CHIEF PLANS EXAMINER | | | (561) 805-6710 | | | [email protected] | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2016-01-11 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2016-01-11 |
Time |
08:54 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2016-01-11 |
Time |
08:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
F |
Date |
2015-10-06 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2015-10-06 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2015-10-06 |
Time |
10:49 |
Sent To |
|
|
| Notes |
| 2015-10-06 10:50:46 | NEED CLARIFICATION OF WINDOWS, FRAME COLOR, GLAZING, | | | GRID COLOR.. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2015-12-15 |
Time |
10:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-11-19 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2015-11-19 |
Time |
13:32 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2015-10-08 |
Time |
08:42 |
Sent To |
|
|
| Notes |
| 2015-10-09 08:46:05 | SENT TO ZONING WITH 15070952 (TRAVELLING TOGETHER) |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-10-09 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2015-10-06 |
Time |
08:41 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2015-07-23 |
Time |
08:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2015-12-19 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-12-19 |
Time |
09:10 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-12-19 |
Time |
08:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2015-08-03 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-08-03 |
Time |
05:40 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-08-03 |
Time |
05:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2015-10-06 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2015-10-06 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2015-10-06 |
Time |
10:49 |
Sent To |
|
|
| Notes |
|
|