Plan Review Details - Permit 15070853
Plan Review Stops For Permit 15070853
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2015-08-06 Cont ID  
Sent By jwitmer Date 2015-08-06 Time 07:30 Rev Time  
Received By jwitmer Date 2015-08-05 Time 07:45 Sent To  
Notes
2015-08-06 07:32:56BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15070853
 ADD: 8989 OKEECHOBEE BLVD. SUITE # 200
 CONT: PROJECTS R US INC.
 TEL: (954)224-6073
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION,
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: THURS. AUG. 06/2015
  
 ACTION: BUILDING PROVISO
 BUILDING APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE
 ADDITIONAL REVIEWS WITH ASSOCIATED FEES.
  
 1) SHEETS E1 & SF1.0 BOTH SHOW A EGRESS SIGN DIRECTING
 THE OCCUPANTS THROUGH THE STORAGE ROOM AS A SECOND
 MEANS OF EGRESS. THE OCCUPANT LOAD IS 37 OCCUPANTS/
 FULLY SPRINKLERED, COMMON PATH OF TRAVEL ALLOWABLE 100
 FT. TRAVEL DISTANCE LESS THAN 100 FT.
  
 A REVISION IS REQUIRED. EITHER REMOVE THIS DIRECTIONAL
 EXIT LIGHT OR SHOW COMPLIANCE WITH TRAVEL THROUGH THE
 STOCKROOM.
 2014 FBC-B 1014.2 EGRESS THROUGH INTERVENING ROOMS
 EXCEPTION # 2:
  
 2. MEANS OF EGRESS ARE NOT PROHIBITED THROUGH
 STOCKROOMS IN GROUP M OCCUPANCIES WHEN ALL OF THE
 FOLLOWING ARE MET:
  
 2.1. THE STOCK IS OF THE SAME HAZARD CLASSIFICATION AS
 THAT FOUND IN THE MAIN RETAIL AREA;
  
 2.2. NOT MORE THAN 50 PERCENT OF THE EXIT ACCESS IS
 THROUGH THE STOCKROOM;
  
 2.3. THE STOCKROOM IS NOT SUBJECT TO LOCKING FROM THE
 EGRESS SIDE; AND
  
 2.4. THERE IS A DEMARCATED, MINIMUM 44-INCH-WIDE (1118
 MM) AISLE DEFINED BY FULL- OR PARTIAL-HEIGHT FIXED
 WALLS OR SIMILAR CONSTRUCTION THAT WILL MAINTAIN THE
 REQUIRED WIDTH AND LEAD DIRECTLY FROM THE RETAIL AREA
 TO THE EXIT WITHOUT OBSTRUCTIONS.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2015-08-14 Cont ID  
Sent By skennedy Date 2015-08-14 Time 15:16 Rev Time 0.00
Received By skennedy Date 2015-08-14 Time 15:16 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2015-07-30 Cont ID  
Sent By scaldero Date 2015-07-30 Time 16:58 Rev Time 0.00
Received By scaldero Date 2015-07-30 Time 16:58 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-08-14 Cont ID  
Sent By skennedy Date 2015-08-14 Time 15:16 Rev Time 0.00
Received By skennedy Date 2015-07-21 Time 12:06 Sent To  
Notes
2015-07-23 12:06:35B06


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved