| Plan Review Stops For Permit 15070750 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2015-09-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-09-23 |
Time |
12:01 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-09-23 |
Time |
11:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-08-05 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-08-05 |
Time |
07:45 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-08-05 |
Time |
07:15 |
Sent To |
|
|
| Notes |
| 2015-08-05 07:48:22 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 15070750 | | | ADD: 905 N. DIXIE HWY. | | | CONT: FLORIDA VENT, INC. | | | TEL: (954)294-2793 | | | E-MAIL: | | | | | | 2014 FLORIDA BUILDING CODE W | | | * 2014 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: WED. AUG. 05/2015 | | | ACTION: DENIED | | | | | | 1) SHEET 1 OF 3 SHOWS THE INSTALATION OF ROOF TOP | | | INTAKE AND EXHAUST FANS. THE PLANS SHOW CURB DETAILS | | | BUT NO PRODUCT APPROVALS AND FASTENING FOR THE CURB TO | | | THE ROOF NOR FROM THE CURB TO FAN UNITS. 2014 FBC-B | | | 1609.6.4.4.1 COMPONENTS AND CLADDING. FLORIDA | | | DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 | | | (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS | | | THAT WILL REQUIRE PRODUCT APPROVALS: | | | (31) (D) ROOFING PRODUCTS AND ASSEMBLIES, CURBS ROOF | | | TOP INTAKE AND EXHAUST FANS | | | | | | | | | 2) 2014 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2015-10-09 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2015-10-09 |
Time |
08:02 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2015-10-09 |
Time |
07:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2015-09-24 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2015-09-24 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2015-09-24 |
Time |
11:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2015-07-23 |
|
|
Cont ID |
|
| Sent By |
Lindow |
Date |
2015-07-21 |
Time |
|
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2015-07-21 |
Time |
|
Sent To |
M |
|
| Notes |
| 2015-07-23 14:28:42 | HOOD SUPPRESSION PLANS NOT SUBMITTED. WILL NEED | | | SEPARATE PERMIT. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2015-11-05 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-11-05 |
Time |
16:07 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-10-28 |
Time |
09:38 |
Sent To |
|
|
| Notes |
| 2015-10-30 09:39:12 | RESUB ROUTED TO AAPONTE VIA SGRAHAM'S DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-10-09 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2015-10-09 |
Time |
08:02 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2015-08-28 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-08-05 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2015-08-05 |
Time |
|
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2015-07-20 |
Time |
13:24 |
Sent To |
|
|
| Notes |
| 2015-07-23 16:14:26 | B25 | | 2015-07-20 13:24:43 | FIRE BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2015-10-19 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-10-19 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-10-19 |
Time |
15:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2015-08-31 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-08-31 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-08-31 |
Time |
16:18 |
Sent To |
|
|
| Notes |
| 2015-08-31 16:46:28 | 2ND REVIEW: FBC 2014 MECHANICAL | | | PERMIT #15070750 | | | 8/31/15 | | | | | | 1) THE FLORIDA BUILDING CODE FIFTH EDITION (2014) | | | MECHANICAL WENT INTO EFFECT ON JUNE 30, 2015: PLEASE | | | UPDATE THE 2010 CODE REFERENCE ON SHEET 1, AND UPDATE | | | THE PLANS TO BE IN COMPLIANCE. | | | 2. THE COMBUSTION AIR CALCULATION SHOWN ON SHEET 1 IS | | | INCORRECT. PLEASE REVIEW SECTIONS 304.9 & 304.9.3 | | | FBC-14 FUEL GAS. | | | 304.9: MECHANICAL COMBUSTION AIR SUPPLY. WHERE ALL | | | COMBUSTION AIR IS PROVIDED BY A MECHANICAL AIR SUPPLY | | | SYSTEM, THE COMBUSTION AIR SHALL BE SUPPLIED FROM THE | | | OUTDOORS AT A RATE NOT LESS THAN 0.35 CUBIC FEET PER | | | MINUTE PER 1,000 BTU/H (0.034 M3/MIN PER KW) OF TOTAL | | | INPUT RATING OF ALL APPLIANCES LOCATED WITHIN THE | | | SPACE. | | | 304.9.3: COMBINED COMBUSTION AIR AND VENTILATION AIR | | | SYSTEM. WHERE COMBUSTION AIR IS PROVIDED BY THE | | | BUILDING'S MECHANICAL VENTILATION SYSTEM, THE SYSTEM | | | SHALL PROVIDE THE SPECIFIED COMBUSTION AIR RATE IN | | | ADDITION TO THE REQUIRED VENTILATION AIR. | | | PLEASE REVISE THE PLANS TO SHOW COMPLIANCE. | | | 3) REVIEW SECTION 508.11 FBC-14 MECHANICAL: MAKE AIR | | | TEMPERATURE. | | | THE TEMPERATURE DIFFERENTIAL BETWEEN MAKEUP AIR AND THE | | | AIR IN THE CONDITIONED SPACE SHALL NOT EXCEED 10 | | | DEGREES F (6 DEGREES C) EXCEPT WHERE THE ADDED HEATING | | | AND COOLING LOADS OF THE MAKEUP AIR DO NOT EXCEED THE | | | CAPACITY OF THE HVAC SYSTEM. | | | GIVEN THE FACT THAT THE DRYBULB TEMPERATURE FOR WEST | | | PALM BEACH IS 90 DEGREES, PLEASE INDICATE HOW WILL THE | | | SUPPLY AIR WILL BE COOLED TO MEET THIS CODE | | | REQUIREMENT. | | | 4) PLEASE PLACE A NOTE ON THE PLAN INDICATING THAT THE | | | GAS APPLIANCES AND GAS PIPING WILL BE DONE UNDER A | | | SEPARATE PERMIT. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2015-07-23 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2015-07-23 |
Time |
14:28 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-07-23 |
Time |
14:09 |
Sent To |
|
|
| Notes |
| 2015-07-23 14:16:37 | 1ST REVIEW: FBC 2014 MECHANICAL | | | | | | 1) THE CITY OF WEST PALM BEACH BUILDING DIVISION | | | REQUIRES FIRE SUPPRESSION PLANS TO BE SUBMITTED WITH | | | KITCHEN GREASE HOOD PLANS. PLEASE SUBMIT THE PLANS AND | | | SPECIFICATIONS, AND SUB-PERMIT APPLICATION. | | | 2) THE HOOD SECTION DRAWING ON SHEET 1 INDICATES GAS | | | APPLIANCES: PROVIDE A GAS PIPING PLAN, A GAS ISOMETRIC | | | DRAWING, AND SUBMIT MANUFACTURER'S SPECIFICATIONS FOR | | | THE GAS-FIRED APPLIANCES. | | | 3) INDICATE HOW COMBUSTION AIR IS BEING PROVIDED TO THE | | | GAS APPLIANCES- REFER TO SECTION 304 FBC-14 FUEL GAS. | | | PLEASE INCLUDE CALCULATIONS TO VERIFY COMPLIANCE WITH | | | WHICHEVER METHOD IS CHOSEN. | | | 4) PROVIDE A DIMENSIONED FRONT SECTION VIEW OF THE HOOD | | | INDICATING THE MINIMUM 6" HOOD OVERHANG OF THE | | | APPLIANCES ON ALL OPEN SIDES OF THE HOOD, AND THE | | | MAXIMUM 4' DISTANCE BETWEEN THE FRONT LOWER LIP OF THE | | | HOOD AND THE COOKING SURFACES OF THE APPLIANCES. | | | 5) THE PLAN INDICATES A 3" CLEARANCE BETWEEN THE BACK | | | OF THE HOOD AND THE EXISTING WALL- REFER TO SECTION | | | 507.9 (EXCEPTION) AND VERIFY THAT THE WALL IS OF | | | NON-COMBUSTIBLE CONSTRUCTION, AND THE STAINLESS STEEL | | | WALL PANELS ARE EXTENDING NOT LESS THAN 18" IN ALL | | | DIRECTIONS OF THE HOOD. | | | 6) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE THERMAL | | | CERAMICS GREASE DUCT WRAP. | | | 7) SHOW THE LOCATIONS OF REQUIRED CLEANOUTS ON THE TWO | | | GREASE DUCTS AND PROVIDE DETAILS FOR INSTALLATION- | | | REFER TO SECTION 506.3.8 ITEMS 1-8 FBC-14 MECHANICAL. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
N |
Date |
2015-11-05 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2015-11-05 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2015-11-05 |
Time |
16:05 |
Sent To |
|
|
| Notes |
| 2015-11-05 16:05:29 | PLEASE SUBMIT SEPARATE PERMIT FOR THE SCREENING OF THE | | | MECHANICAL EQUIPMENT. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2015-10-16 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2015-09-25 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2015-09-25 |
Time |
15:50 |
Sent To |
|
|
| Notes |
| 2015-09-25 15:53:45 | PROVISO: NEW MECHANICAL EQUIPMENT SHALL BE SCREENED | | | FROM VIEW BY A WALL OR LOUVER AS TALL AS THE PROPOSED | | | EQUIPEMENT. FINAL CO SHALL NOT BE ISSUED UNTIL | | | SCREENING IS INSTALLED. |
|
|