Plan Review Details - Permit 15070600
Plan Review Stops For Permit 15070600
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-08-18 Cont ID  
Sent By shill Date 2015-08-18 Time 12:06 Rev Time 0.00
Received By shill Date 2015-08-18 Time 12:06 Sent To FIRE
Notes
2015-08-18 12:06:35****PROVISO****
 ISSUED AT CONTRACTOR?S RISK
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 THE PRODUCT APPROVAL IS VALIDATED. A STATUS OF APPROVED
 IS REQUIRED.
  
 AN APPROVED PRODUCT APPROVAL IS REQUIRED PRIOR TO FINAL
 INSPECTION. IT IS THE CONTRACTOR?S RESPONSIBILITY TO
 ENSURE THAT AN APPROVED PRODUCT APPROVAL IS ON FILE.
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-08-07 Cont ID  
Sent By shill Date 2015-08-07 Time 12:13 Rev Time 0.00
Received By shill Date 2015-08-07 Time 12:13 Sent To FIRE
Notes
2015-08-07 12:55:14****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. EXPIRED PRODUCT APPROVALS WERE SUBMITTED. GOVERNING
 CODE CHANGED EFFECTIVE JUNE 31, 2015. PROVIDE CURRENT
 PRODUCT APPROVALS, FS553, FAC9N-3, FBC 1609 (FBC 2014
 RATHER THAN FBC 2010).
  
 2. AS STANDARD HARDWARE (RATHER THAN PANIC DEVICES /
 FIRE EXIT HARDWARE) IS PROPOSED, SEE FBC1008.1.10.
 PROVIDE INFORMATION REGARDING THE EXISTING SPACE;
 PROVIDE OCCUPANCY CLASSIFICATION AND OCCUPANT LOAD. IF
 YOU ARE UNABLE TO PROVIDE THAT INFORMATION, PROVIDE A
 BASIC FLOOR PLAN WHICH SHOWS THE DIMENSIONS OF THE
 INTERIOR SPACE AND LAYOUT (SHOW SEATING, CASH REGISTER
 AREA, SELF SERVICE AREA, REFRIGERATED CASES, WORK
 SPACE, ETC.) AND AN OCCUPANT LOAD WILL BE CALCULATED
 FOR YOU.
  
 3. SHOW DOOR SWING, FBC 1008.
  
 4. ON THE PRODUCT APPROVAL OR ON THE SHOP DRAWINGS,
 INDICATE THRESHOLD PROPOSED, FBC 5TH ED. ACCESSIBILITY
 404.2.5. IT APPEARS TO STATE "AHZ ONLY THRESHOLD." DOES
 THIS MEAN ADA? ACCESSIBLE ROUTE REQUIRED.
  
 5. PROVIDE BUILDING HEIGHT, FBC 1609. DESIGN PRESSURE
 REQUIREMENTS WILL BE DETERMINED FOR YOU BUT BUILDING
 HEIGHT IS REQUIRED. ALSO BUILDING HEIGHT (AND NUMBER OF
 STORIES) IS REQUIRED TO DETERMINE SCOPE.
  
 6. ON BOTH PRODUCT APPROVALS, INDICATE WHICH GLASS OR
 ANCHORING OPTION IS PROPOSED. FOR INSTANCE, SEE SHEET 4
 OF 15, TWO DIFFERENT OPTIONS FOR INSTALLATION.
  
 ENOUGH INFORMATION TO DETERMINE CODE COMPLIANCE IS
 REQUIRED. IT IS HELPFUL IF ALL DETAILS PERTINENT TO THE
 INSTALLATION ARE HIGHLIGHTED FOR THE INSPECTOR.
  
 7. PLEASE PROVIDE CLEAR, LEGIBLE PRODUCT APPROVALS,
 WWW.FLORIDABUILDING.ORG. THE PRODUCT APPROVALS NEED TO
 BE LEGIBLE FOR PLAN REVIEW, INSPECTIONS, AND RECORDS
 RETENTION.
  
 8. FBC 1008.1, DOORS IN EXCESS OF THE MINIMUM REQUIRED
 ARE TO MEET THE REQUIREMENTS OF EGRESS DOORS.
  
 MEANS OF EGRESS DOORS SHALL BE READILY DISTINGUISHABLE
 FROM THE ADJACENT CONSTRUCTION. BASED ON THE SHOP
 DRAWING, THE SIDELITE APPEARS THE SAME AS THE DOOR.
 PLEASE REVISE TO SHOW HOW THE DOOR IS READILY
 DISTINGUISHABLE FROM THE ADJACENT CONSTRUCTION. (NOTE
 8/11 - DOOR HARDWARE WILL DISTINGUISH THE DOOR FROM THE
 SIDELITES)
  
  
  
  
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2015-08-19 Cont ID  
Sent By pleduc Date 2015-08-19 Time   Rev Time 0.00
Received By pleduc Date 2015-08-19 Time 09:58 Sent To  
Notes
2015-08-19 10:07:04THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 1) LOCKING OF EXIT DOOR SHALL COMPLY WITH NFPA 101,
 CHAPTER 7.
  
 DOORS SHALL BE ARRANGED TO BE OPENED READILY FROM THE
 EGRESS SIDE WHENEVER THE BUILDING IS OCCUPIED. LOCKS,
 IF PROVIDED, SHALL NOT REQUIRE THE USE OF A KEY, TOOL,
 OR SPECIAL KNOWLEDGE OR EFFORT FOR OPERATION FROM THE
 EGRESS SIDE.
  
 PER SECTION 7.2.1.5.9, THE LOCK/LATCH RELEASING
 MECHANISM ON ALL DOORS SHALL OPEN THE DOOR WITH NOT
 MORE THAN ONE RELEASING OPERATION. THE RELEASING
 MECHANISM SHALL HAVE AN OBVIOUS METHOD OF OPERATION
 THAT IS READILY OPERATED UNDER ALL LIGHTING CONDITIONS.
 THE RELEASING DEVICE SHOULD BE CAPABLE OF BEING
 OPERATED WITH ONE HAND AND SHOULD NOT REQUIRE TIGHT
 GRASPING, TIGHT PINCHING OR TWISTING OF THE WRIST TO
 OPERATE.
  
 THUMB-TURN LOCK TO BE EQUIPPED WITH AN ?OPEN/LOCKED?
 INDICATOR WINDOW (SUCH AS ADAMS RITE 4089 OR SIMILAR).
  
 2) THE GLOW-IN-THE-DARK EXIT SIGN IS NOT APPROVED. THE
 EXIT SIGN SHALL BE HARDWAIRED WITH BATTERY BACK UP.
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-08-19 Cont ID  
Sent By pleduc Date 2015-08-19 Time   Rev Time 0.00
Received By pleduc Date 2015-08-12 Time 11:42 Sent To  
Notes
2015-08-18 12:11:068/18 TO FIRE BOX
  
2015-08-12 11:42:31SHILL DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-08-11 Cont ID  
Sent By shill Date 2015-08-11 Time 14:23 Rev Time 0.00
Received By shill Date 2015-08-07 Time 12:55 Sent To  
Notes
2015-08-07 12:55:408/7 TO FIRE
  
2015-08-06 17:00:49TO MISC 2
2015-07-23 18:45:57SEND TO AAPONTE
2015-07-15 11:34:52ROUTED TO MISC1

Review Stop Z ZONING
Rev No 1 Status P Date 2015-08-06 Cont ID  
Sent By aaponte Date 2015-08-06 Time 17:00 Rev Time 0.00
Received By aaponte Date 2015-08-06 Time 17:00 Sent To  
Notes
2015-08-06 17:00:35OK BY CHRIS ROOG REPRESENTING THE CITY.